Abstract

Speckle tracking echocardiography is an emerging technique, which is currently being included in clinical guidelines. We sought to investigate the impact of transducer frequency settings on speckle tracking derived measures. The study comprised of 22 subjects prospectively enrolled for a randomized controlled trial (LOOP-study, Clinicaltrials.gov:NCT02036450). Patients were above 70 years of age with increased risk of stroke, and had an echocardiogram performed, which included focused images of the left ventricle. Focused images were obtained with the transducer frequency set at both 1.7/3.3 and 1.5/3.0 MHz. The images were obtained immediately after each other at the exact same position for the two settings. Speckle tracking was performed in three apical projections, allowing for acquisition of layered global longitudinal strain (GLS) and strain rate measures. Concordance between the frequency settings was tested for endo-, mid-, and epicardial GLS and strain rates by coefficients of variation, bias coefficients and visually displayed by Bland–Altman plots. Bland–Altman plots did not reveal any significant over- or underestimation of any speckle tracking measure. Bias coefficients showed that none of the measurements differed significantly between the two settings (bias for GLSendo = − 0.07 ± 2.94, p = 0.91; GLSmid = 0.02 ± 2.70, p = 0.98, GLSepi = 0.07 ± 2.53, p = 0.90). Coefficients of variation were as follows: GLSendo = 15.11%, GLSmid = 15.28%, GLSepi = 17.26%, systolic strain rate = 15.66%, early diastolic strain rate = 38.46%, late diastolic strain rate = 11%. Changing between transducer frequency settings does not systematically derange speckle tracking measures. One can safely reduce the transducer frequency without compromising the validity of speckle tracking derived measures.
Literature
1.
go back to reference Biering-Sørensen T, Biering-Sørensen SR, Olsen FJ et al (2017) Global longitudinal strain by echocardiography predicts long-term risk of cardiovascular Morbidity and mortality in a low-risk general population: the Copenhagen city heart study. Circ Cardiovasc Imaging. doi:10.1161/CIRCIMAGING.116.005521 Biering-Sørensen T, Biering-Sørensen SR, Olsen FJ et al (2017) Global longitudinal strain by echocardiography predicts long-term risk of cardiovascular Morbidity and mortality in a low-risk general population: the Copenhagen city heart study. Circ Cardiovasc Imaging. doi:10.​1161/​CIRCIMAGING.​116.​005521
2.
go back to reference Bax JJ, Delgado V, Sogaard P et al (2017) Prognostic implications of left ventricular global longitudinal strain in heart failure patients with narrow QRS complex treated with cardiac resynchronization therapy: a subanalysis of the randomized EchoCRT trial. Eur Heart J 38:720–726. doi:10.1093/eurheartj/ehw506 CrossRefPubMed Bax JJ, Delgado V, Sogaard P et al (2017) Prognostic implications of left ventricular global longitudinal strain in heart failure patients with narrow QRS complex treated with cardiac resynchronization therapy: a subanalysis of the randomized EchoCRT trial. Eur Heart J 38:720–726. doi:10.​1093/​eurheartj/​ehw506 CrossRefPubMed
4.
go back to reference Plana JC, Galderisi M, Barac A et al (2014) Expert consensus for multimodality imaging evaluation of adult patients during and after cancer therapy: a report from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging 15:1063–1093. doi:10.1093/ehjci/jeu192 CrossRefPubMedPubMedCentral Plana JC, Galderisi M, Barac A et al (2014) Expert consensus for multimodality imaging evaluation of adult patients during and after cancer therapy: a report from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. Eur Heart J Cardiovasc Imaging 15:1063–1093. doi:10.​1093/​ehjci/​jeu192 CrossRefPubMedPubMedCentral
5.
go back to reference Voigt J-U, Pedrizzetti G, Lysyansky P et al (2015) Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging 16:1–11. doi:10.1093/ehjci/jeu184 CrossRefPubMed Voigt J-U, Pedrizzetti G, Lysyansky P et al (2015) Definitions for a common standard for 2D speckle tracking echocardiography: consensus document of the EACVI/ASE/Industry Task Force to standardize deformation imaging. Eur Heart J Cardiovasc Imaging 16:1–11. doi:10.​1093/​ehjci/​jeu184 CrossRefPubMed
7.
go back to reference Armstrong WF, Ryan T (2009) Feigenbaum’s echocardiography, 7th edn. Lippincott Williams & Wilkins, Philadelphia Armstrong WF, Ryan T (2009) Feigenbaum’s echocardiography, 7th edn. Lippincott Williams & Wilkins, Philadelphia
8.
go back to reference Diederichsen SZ, Haugan KJ, Køber L et al (2017) Atrial fibrillation detected by continuous electrocardiographic monitoring using implantable loop recorder to prevent stroke in individuals at risk (the LOOP study): rationale and design of a large randomized controlled trial. Am Heart J 187:122–132. doi:10.1016/j.ahj.2017.02.017 CrossRefPubMed Diederichsen SZ, Haugan KJ, Køber L et al (2017) Atrial fibrillation detected by continuous electrocardiographic monitoring using implantable loop recorder to prevent stroke in individuals at risk (the LOOP study): rationale and design of a large randomized controlled trial. Am Heart J 187:122–132. doi:10.​1016/​j.​ahj.​2017.​02.​017 CrossRefPubMed
10.
go back to reference Sarvari SI, Haugaa KH, Zahid W et al (2013) Layer-specific quantification of myocardial deformation by strain echocardiography may reveal significant CAD in patients with non-ST-segment elevation acute coronary syndrome. JACC Cardiovasc Imaging 6:535–544. doi:10.1016/j.jcmg.2013.01.009 CrossRefPubMed Sarvari SI, Haugaa KH, Zahid W et al (2013) Layer-specific quantification of myocardial deformation by strain echocardiography may reveal significant CAD in patients with non-ST-segment elevation acute coronary syndrome. JACC Cardiovasc Imaging 6:535–544. doi:10.​1016/​j.​jcmg.​2013.​01.​009 CrossRefPubMed
12.
13.
Metadata
Title
Impact of transducer frequency setting on speckle tracking measures
Authors
Flemming Javier Olsen
Jesper Hastrup Svendsen
Lars Køber
Søren Højberg
Ketil Haugan
Jan Skov Jensen
Tor Biering-Sørensen
Publication date
01-03-2018
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 3/2018
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-017-1254-4

Other articles of this Issue 3/2018

The International Journal of Cardiovascular Imaging 3/2018 Go to the issue