Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 2/2016

01-02-2016 | Original Paper

Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera

Authors: Andrea De Lorenzo, Thais Peclat, Ana Carolina Amaral, Ronaldo S. L. Lima

Published in: The International Journal of Cardiovascular Imaging | Issue 2/2016

Login to get access

Abstract

The purpose of this study is to evaluate the prognostic value of myocardial perfusion SPECT obtained in CZT cameras (CZT–SPECT) with multipinhole collimation in obese patients. CZT–SPECT may be technically challenging in the obese, and its prognostic value remains largely unknown. Patients underwent single-day, rest/stress (supine and prone) imaging. Images were visually inspected and graded as poor, fair or good/excellent. Summed stress and difference scores (SSS and SDS, respectively) were converted into percentages of total perfusion defect and of ischemic defect by division by the maximum possible score. Obesity was defined as a body mass index (BMI) ≥ 30 kg/m2 and classified as class I (BMI 30–34.9 kg/m2), II (BMI 35–39.9 kg/m2), or III (BMI ≥ 40 kg/m2). Patients were followed-up by telephone interview for the occurrence of all-cause death, myocardial infarction or revascularization. A Cox proportional hazards analysis was used to assess the independent predictors of death. Among 1396 patients, 365 (26.1 %) were obese (mean BMI 33.9 ± 3.6; 17.5 % class I, 3.4 % class II, and 3.4 % class III). Image quality was good/excellent in 94.5 % of the obese patients. The annualized mortality rates were not significantly different among obese and non-obese patients, being <1 % with normal CZT–SPECT, and increased with the degree of scan abnormality in both obese and non-obese patients. Age, the use of pharmacologic stress and an abnormal CZT–SPECT, but not obesity, were independent predictors of death. In obese patients, single-day rest/stress CZT–SPECT with a multipinhole camera provides prognostic discrimination with high image quality.
Appendix
Available only for authorised users
Literature
2.
go back to reference Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, Friedman JD, Germano G, Van Train K, Diamond GA (1995) Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 26:639–647CrossRefPubMed Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, Friedman JD, Germano G, Van Train K, Diamond GA (1995) Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 26:639–647CrossRefPubMed
3.
go back to reference Botvinick EH, Taradash MR, Shames DM et al (1978) Thallium-201 myocardial perfusion scintigraphy for the clinical clarification of normal, abnormal and equivocal electrocardiographic stress tests. Am J Cardiol 41:43–51CrossRefPubMed Botvinick EH, Taradash MR, Shames DM et al (1978) Thallium-201 myocardial perfusion scintigraphy for the clinical clarification of normal, abnormal and equivocal electrocardiographic stress tests. Am J Cardiol 41:43–51CrossRefPubMed
4.
go back to reference Brown KA (1991) Prognostic value of thallium-201 myocardial perfusion imaging. A diagnostic tool comes of age. Circulation 83:363–381CrossRefPubMed Brown KA (1991) Prognostic value of thallium-201 myocardial perfusion imaging. A diagnostic tool comes of age. Circulation 83:363–381CrossRefPubMed
5.
go back to reference DePuey EG (1994) How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med 35:699–702PubMed DePuey EG (1994) How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med 35:699–702PubMed
6.
go back to reference Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Berman DS (2008) High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 1:156–163CrossRefPubMed Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Berman DS (2008) High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 1:156–163CrossRefPubMed
7.
go back to reference Buechel RR, Herzog BA, Husmann L et al (2010) Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging 37:773–778CrossRefPubMed Buechel RR, Herzog BA, Husmann L et al (2010) Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation. Eur J Nucl Med Mol Imaging 37:773–778CrossRefPubMed
8.
go back to reference Sharir T, Slomka PJ, Hayes SW et al (2010) Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol 55:1965–1974CrossRefPubMed Sharir T, Slomka PJ, Hayes SW et al (2010) Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol 55:1965–1974CrossRefPubMed
9.
go back to reference Herzog BA, Buechel RR, Katz R et al (2010) Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med 51:46–51CrossRefPubMed Herzog BA, Buechel RR, Katz R et al (2010) Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction. J Nucl Med 51:46–51CrossRefPubMed
10.
go back to reference Gimelli A, Bottai M, Giorgetti A, Genovesi D, Filidei E, Marzullo P (2012) Evaluation of ischaemia in obese patients: feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera. Eur J Nucl Med Mol Imaging 39:1254–1261CrossRefPubMed Gimelli A, Bottai M, Giorgetti A, Genovesi D, Filidei E, Marzullo P (2012) Evaluation of ischaemia in obese patients: feasibility and accuracy of a low-dose protocol with a cadmium-zinc telluride camera. Eur J Nucl Med Mol Imaging 39:1254–1261CrossRefPubMed
11.
go back to reference Fiechter M, Gebhard C, Fuchs TA et al (2012) Cadmium-zinc-telluride myocardial perfusion imaging in obese patients. J Nucl Med 53:1401–1406CrossRefPubMed Fiechter M, Gebhard C, Fuchs TA et al (2012) Cadmium-zinc-telluride myocardial perfusion imaging in obese patients. J Nucl Med 53:1401–1406CrossRefPubMed
12.
go back to reference Schwartz RG, Wexler O, Peterson B, Schwartz AM, Mis FJ, Mackin M (2013) Cadmium-zinc-telluride SPECT in very morbidly obese patients routinely provides high-diagnostic-quality myocardial perfusion imaging. J Nucl Med 54:661–662CrossRefPubMed Schwartz RG, Wexler O, Peterson B, Schwartz AM, Mis FJ, Mackin M (2013) Cadmium-zinc-telluride SPECT in very morbidly obese patients routinely provides high-diagnostic-quality myocardial perfusion imaging. J Nucl Med 54:661–662CrossRefPubMed
14.
go back to reference Henzlova MJ, Cerqueira MD, Hansen CL, Mahmarian JJ, Yao SS (2009) ASNC imaging guidelines for nuclear cardiology procedures: stress protocols and tracers. J Nucl Cardiol 16:331–361CrossRef Henzlova MJ, Cerqueira MD, Hansen CL, Mahmarian JJ, Yao SS (2009) ASNC imaging guidelines for nuclear cardiology procedures: stress protocols and tracers. J Nucl Cardiol 16:331–361CrossRef
15.
go back to reference Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, Friedman JD, Germano G, Van Train K, Diamond GA (1995) Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 26:639–647CrossRefPubMed Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico JA, Wang FP, Friedman JD, Germano G, Van Train K, Diamond GA (1995) Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon emission computed tomography. J Am Coll Cardiol 26:639–647CrossRefPubMed
16.
go back to reference Hachamovitch R, Rozanski A, Shaw L, Stone G, Thomson L, Friedman J et al (2011) Impact of ischaemia and scar on the therapeutic benefit derived from myocardial revascularization vs. medical therapy among patients undergoing stress-rest myocardial perfusion scintigraphy. Eur Heart J 32:1012–1024CrossRefPubMed Hachamovitch R, Rozanski A, Shaw L, Stone G, Thomson L, Friedman J et al (2011) Impact of ischaemia and scar on the therapeutic benefit derived from myocardial revascularization vs. medical therapy among patients undergoing stress-rest myocardial perfusion scintigraphy. Eur Heart J 32:1012–1024CrossRefPubMed
18.
go back to reference McGee DL, Diverse Populations Collaboration (2005) Body mass index and mortality: a meta-analysis based on person-level data from twenty-six observational studies. Ann Epidemiol 15:87–97CrossRefPubMed McGee DL, Diverse Populations Collaboration (2005) Body mass index and mortality: a meta-analysis based on person-level data from twenty-six observational studies. Ann Epidemiol 15:87–97CrossRefPubMed
19.
go back to reference Berrington de Gonzalez A, Hartge P, Cerhan JR et al (2010) Body-mass index and mortality among 1.46 million white adults. N Engl J Med 363:2211–2219CrossRefPubMed Berrington de Gonzalez A, Hartge P, Cerhan JR et al (2010) Body-mass index and mortality among 1.46 million white adults. N Engl J Med 363:2211–2219CrossRefPubMed
20.
go back to reference Ghanem MA, Kazim NA, Elgazzar AH (2011) Impact of obesity on nuclear medicine imaging. J Nucl Med Technol 39:40–50CrossRefPubMed Ghanem MA, Kazim NA, Elgazzar AH (2011) Impact of obesity on nuclear medicine imaging. J Nucl Med Technol 39:40–50CrossRefPubMed
21.
go back to reference Duvall WL, Croft LB, Corriel JS et al (2006) SPECT myocardial perfusion imaging in morbidly obese patients: image quality, hemodynamic response to pharmacologic stress, and diagnostic and prognostic value. J Nucl Cardiol 13:202–209CrossRefPubMed Duvall WL, Croft LB, Corriel JS et al (2006) SPECT myocardial perfusion imaging in morbidly obese patients: image quality, hemodynamic response to pharmacologic stress, and diagnostic and prognostic value. J Nucl Cardiol 13:202–209CrossRefPubMed
22.
23.
go back to reference Nakazato R, Slomka PJ, Fish M et al (2015) Quantitative high-efficiency cadmium-zinc telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study. J Nucl Cardiol 22:266–275CrossRefPubMed Nakazato R, Slomka PJ, Fish M et al (2015) Quantitative high-efficiency cadmium-zinc telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study. J Nucl Cardiol 22:266–275CrossRefPubMed
24.
go back to reference DeCicco AE, Sokil AB, Marhefka GD, Reist K, Hansen CL (2015) Feasibility of SPECT myocardial perfusion imaging in the super-obese using a multi-head semiconductor camera with attenuation correction. J Nucl Cardiol 22:344–350CrossRefPubMed DeCicco AE, Sokil AB, Marhefka GD, Reist K, Hansen CL (2015) Feasibility of SPECT myocardial perfusion imaging in the super-obese using a multi-head semiconductor camera with attenuation correction. J Nucl Cardiol 22:344–350CrossRefPubMed
25.
go back to reference Mokdad AH, Ford ES, Bowman BA, Dietz WD, Vinicor F, Bales VS, Marks JS (2003) Prevalence of obesity, diabetes, and obesity-related health risk factors, 2001. JAMA 289:76–79CrossRefPubMed Mokdad AH, Ford ES, Bowman BA, Dietz WD, Vinicor F, Bales VS, Marks JS (2003) Prevalence of obesity, diabetes, and obesity-related health risk factors, 2001. JAMA 289:76–79CrossRefPubMed
26.
go back to reference Hachamovitch R, Berman DS, Kiat H, Cohen I, Cabico A, Friedman JD, Diamond GA (1996) Exercise myocardial perfusion SPECT in patients with known or suspected coronary artery disease. Incremental prognostic value and use in risk stratification. Circulation 93:905–914CrossRefPubMed Hachamovitch R, Berman DS, Kiat H, Cohen I, Cabico A, Friedman JD, Diamond GA (1996) Exercise myocardial perfusion SPECT in patients with known or suspected coronary artery disease. Incremental prognostic value and use in risk stratification. Circulation 93:905–914CrossRefPubMed
27.
go back to reference Bourque JM, Beller GA (2011) Stress myocardial perfusion imaging for assessing prognosis: an update. JACC Cardiovasc Imaging 4:1305–1319CrossRefPubMed Bourque JM, Beller GA (2011) Stress myocardial perfusion imaging for assessing prognosis: an update. JACC Cardiovasc Imaging 4:1305–1319CrossRefPubMed
28.
go back to reference Romero-Corral A, Montori VM, Somers VK, Korinek J, Thomas RJ, Allison TG, Mookadam F, Lopez-Jimenez F (2006) Association of bodyweight with total mortality and with cardiovascular events in coronary artery disease: a systematic review of cohort studies. Lancet 368:666–678CrossRefPubMed Romero-Corral A, Montori VM, Somers VK, Korinek J, Thomas RJ, Allison TG, Mookadam F, Lopez-Jimenez F (2006) Association of bodyweight with total mortality and with cardiovascular events in coronary artery disease: a systematic review of cohort studies. Lancet 368:666–678CrossRefPubMed
Metadata
Title
Prognostic evaluation in obese patients using a dedicated multipinhole cadmium-zinc telluride SPECT camera
Authors
Andrea De Lorenzo
Thais Peclat
Ana Carolina Amaral
Ronaldo S. L. Lima
Publication date
01-02-2016
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 2/2016
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-015-0770-3

Other articles of this Issue 2/2016

The International Journal of Cardiovascular Imaging 2/2016 Go to the issue