Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 8/2014

01-12-2014 | Original Paper

Accelerated analysis of three-dimensional blood flow of the thoracic aorta in stroke patients

Authors: Thomas Wehrum, Miriam Kams, Laure Schroeder, Johann Drexl, Anja Hennemuth, Andreas Harloff

Published in: The International Journal of Cardiovascular Imaging | Issue 8/2014

Login to get access

Abstract

To test if new software accelerates analysis of in vivo acquired 4D flow MRI data. Respiration-gated and ECG-synchronized 4D flow MRI of the aorta was performed in 20 stroke patients using a routine 3-Tesla MRI system (TIMTRIO, Siemens, Germany). 3D blood flow data was processed by one experienced observer using new (A = MEVISFlow) and widely-used software (B = EnSight + Velomap-/FlowTool). Evaluation included: inter-/intra-observer variability of software A and inter-software comparison regarding (1) blood flow quantification (total-/peak flow) and (2) flow visualisation, plus (3) measurement of the time required for visualization and quantification of data (software A&B). (1) Inter-/intra-observer agreement of software A (mean difference ≤5.2 and ≤0.9 %, respectively) and inter-software agreement (mean difference ≤ 2.2 %) was high with high correlation of peak and total blood flow (r ≥ 0.74; p < 0.001 and r ≥ 0.91; p < 0.001). (2) Comparison of blood flow visualization showed substantial agreement (κ ≥ 0.68). (3) Data-analysis was three times faster when using software A [18:10 (±1:29) vs. 58:30 (±5:28) min; p < 0.0001]. Acceleration of blood flow quantification and visualisation using new software strongly facilitates future applications of 4D flow MRI and thus enables its usage in larger patient cohorts in clinical research and routine.
Literature
1.
go back to reference Markl M, Wu C, Hurley MC et al (2013) Cerebral arteriovenous malformation: complex 3D hemodynamics and 3D blood flow alterations during staged embolization. J Magn Reson Imaging 38(4):946–950PubMedCrossRef Markl M, Wu C, Hurley MC et al (2013) Cerebral arteriovenous malformation: complex 3D hemodynamics and 3D blood flow alterations during staged embolization. J Magn Reson Imaging 38(4):946–950PubMedCrossRef
2.
go back to reference Schnell S, Ansari SA, Vakil P et al (2014) Three-dimensional hemodynamics in intracranial aneurysms: influence of size and morphology. J Magn Reson Imaging 39(1):120–131PubMedCrossRef Schnell S, Ansari SA, Vakil P et al (2014) Three-dimensional hemodynamics in intracranial aneurysms: influence of size and morphology. J Magn Reson Imaging 39(1):120–131PubMedCrossRef
3.
go back to reference Hope MD, Purcell DD, Hope TA et al (2009) Complete intracranial arterial and venous blood flow evaluation with 4D flow MR imaging. AJNR Am J Neuroradiol 30(2):362–366PubMedCrossRef Hope MD, Purcell DD, Hope TA et al (2009) Complete intracranial arterial and venous blood flow evaluation with 4D flow MR imaging. AJNR Am J Neuroradiol 30(2):362–366PubMedCrossRef
4.
go back to reference Clough RE, Waltham M, Giese D, Taylor PR, Schaeffter T (2012) A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging. J Vasc Surg 4:914–923CrossRef Clough RE, Waltham M, Giese D, Taylor PR, Schaeffter T (2012) A new imaging method for assessment of aortic dissection using four-dimensional phase contrast magnetic resonance imaging. J Vasc Surg 4:914–923CrossRef
5.
go back to reference Hope T, Markl M, Wigstrom L et al (2007) Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging 26(6):1471–1479PubMedCrossRef Hope T, Markl M, Wigstrom L et al (2007) Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping. J Magn Reson Imaging 26(6):1471–1479PubMedCrossRef
6.
go back to reference Geiger J, Hirtler D, Bürk J et al (2014) Postoperative pulmonary and aortic 3D haemodynamics in patients after repair of transposition of the great arteries. Eur Radiol 24(1):200–208PubMedCrossRef Geiger J, Hirtler D, Bürk J et al (2014) Postoperative pulmonary and aortic 3D haemodynamics in patients after repair of transposition of the great arteries. Eur Radiol 24(1):200–208PubMedCrossRef
7.
go back to reference Von Knobelsdorff-Brenkenhoff F, Trauzeddel RF, Barker AJ et al (2013) Blood flow characteristics in the ascending aorta after aortic valve replacement-a pilot study using 4D-flow MRI. Int J Cardiol 170(3):426–433CrossRef Von Knobelsdorff-Brenkenhoff F, Trauzeddel RF, Barker AJ et al (2013) Blood flow characteristics in the ascending aorta after aortic valve replacement-a pilot study using 4D-flow MRI. Int J Cardiol 170(3):426–433CrossRef
8.
go back to reference Markl M, Arnold R, Hirtler D et al (2009) Three-dimensional flow characteristics in aortic coarctation and poststenotic dilatation. J Comput Assist Tomogr 33(5):776–778PubMedCrossRef Markl M, Arnold R, Hirtler D et al (2009) Three-dimensional flow characteristics in aortic coarctation and poststenotic dilatation. J Comput Assist Tomogr 33(5):776–778PubMedCrossRef
9.
go back to reference Goubergrits L, Mevert R, Yevtushenko P et al (2013) The impact of MRI-based inflow for the hemodynamic evaluation of aortic coarctation. Ann Biomed Eng 41(12):2575–2587PubMedCrossRef Goubergrits L, Mevert R, Yevtushenko P et al (2013) The impact of MRI-based inflow for the hemodynamic evaluation of aortic coarctation. Ann Biomed Eng 41(12):2575–2587PubMedCrossRef
10.
go back to reference Frydrychowicz A, Bley TA, Dittrich S et al (2007) Visualization of vascular hemodynamics in a case of a large patent ductus arteriosus using flow sensitive 3D CMR at 3T. J Cardiovasc Magn Reson 9(3):585–587PubMedCrossRef Frydrychowicz A, Bley TA, Dittrich S et al (2007) Visualization of vascular hemodynamics in a case of a large patent ductus arteriosus using flow sensitive 3D CMR at 3T. J Cardiovasc Magn Reson 9(3):585–587PubMedCrossRef
11.
go back to reference Fredriksson A, Zajac J, Eriksson J et al (2011) 4-D blood flow in the human right ventricle. Am J Physiol 301(6):H2344–H2350 Fredriksson A, Zajac J, Eriksson J et al (2011) 4-D blood flow in the human right ventricle. Am J Physiol 301(6):H2344–H2350
12.
go back to reference Stankovic Z, Csatari Z, Deibert P et al (2012) Normal and altered three-dimensional portal venous hemodynamics in patients with liver cirrhosis. Radiology 262(3):862–873PubMedCrossRef Stankovic Z, Csatari Z, Deibert P et al (2012) Normal and altered three-dimensional portal venous hemodynamics in patients with liver cirrhosis. Radiology 262(3):862–873PubMedCrossRef
13.
go back to reference Roldán-Alzate A, Frydrychowicz A, Niespodzany E et al (2013) In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension. J Magn Reson Imaging 37(5):1100–1108PubMedCentralPubMedCrossRef Roldán-Alzate A, Frydrychowicz A, Niespodzany E et al (2013) In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension. J Magn Reson Imaging 37(5):1100–1108PubMedCentralPubMedCrossRef
14.
go back to reference Bächler P, Valverde I, Pinochet N et al (2013) Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging. Radiology 267(1):67–75PubMedCrossRef Bächler P, Valverde I, Pinochet N et al (2013) Caval blood flow distribution in patients with Fontan circulation: quantification by using particle traces from 4D flow MR imaging. Radiology 267(1):67–75PubMedCrossRef
15.
go back to reference Frydrychowicz A, Berger A, Munoz D et al (2011) Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla. Eur Radiol 22(5):1122–1130PubMedCrossRef Frydrychowicz A, Berger A, Munoz D et al (2011) Interdependencies of aortic arch secondary flow patterns, geometry, and age analysed by 4-dimensional phase contrast magnetic resonance imaging at 3 Tesla. Eur Radiol 22(5):1122–1130PubMedCrossRef
16.
go back to reference Bogren HG, Buonocore MH, Valente RJ (2004) Four-dimensional magnetic resonance velocity mapping of blood flow patterns in the aorta in patients with atherosclerotic coronary artery disease compared to age-matched normal subjects. J Magn Reson Imaging 19(4):417–427PubMedCrossRef Bogren HG, Buonocore MH, Valente RJ (2004) Four-dimensional magnetic resonance velocity mapping of blood flow patterns in the aorta in patients with atherosclerotic coronary artery disease compared to age-matched normal subjects. J Magn Reson Imaging 19(4):417–427PubMedCrossRef
17.
go back to reference Harloff A, Simon J, Brendecke S et al (2010) Complex plaques in the proximal descending aorta: an underestimated embolic source of stroke. Stroke 41(6):1145–1150PubMedCrossRef Harloff A, Simon J, Brendecke S et al (2010) Complex plaques in the proximal descending aorta: an underestimated embolic source of stroke. Stroke 41(6):1145–1150PubMedCrossRef
18.
go back to reference Mahadevia R, Barker AJ, Schnell S et al (2014) Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy. Circulation 129(6):673–682PubMedCrossRef Mahadevia R, Barker AJ, Schnell S et al (2014) Bicuspid aortic cusp fusion morphology alters aortic three-dimensional outflow patterns, wall shear stress, and expression of aortopathy. Circulation 129(6):673–682PubMedCrossRef
19.
go back to reference Frydrychowicz A, François CJ, Turski PA (2011) Four-dimensional phase contrast magnetic resonance angiography: potential clinical applications. Eur J Radiol 80(1):24–35PubMedCentralPubMedCrossRef Frydrychowicz A, François CJ, Turski PA (2011) Four-dimensional phase contrast magnetic resonance angiography: potential clinical applications. Eur J Radiol 80(1):24–35PubMedCentralPubMedCrossRef
20.
go back to reference Markl M, Wegent F, Zech T et al (2010) In vivo wall shear stress distribution in the carotid artery: effect of bifurcation geometry, internal carotid artery stenosis, and recanalization therapy. Circ Cardiovasc Imaging 3(6):647–655PubMedCrossRef Markl M, Wegent F, Zech T et al (2010) In vivo wall shear stress distribution in the carotid artery: effect of bifurcation geometry, internal carotid artery stenosis, and recanalization therapy. Circ Cardiovasc Imaging 3(6):647–655PubMedCrossRef
21.
go back to reference Bieging ET, Frydrychowicz A, Wentland A et al (2011) In vivo three-dimensional MR wall shear stress estimation in ascending aortic dilatation. J Magn Reson Imaging 33(3):589–597PubMedCrossRef Bieging ET, Frydrychowicz A, Wentland A et al (2011) In vivo three-dimensional MR wall shear stress estimation in ascending aortic dilatation. J Magn Reson Imaging 33(3):589–597PubMedCrossRef
22.
go back to reference Markl M, Wallis W, Harloff A (2011) Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI. J Magn Reson Imaging 33(4):988–994PubMedCrossRef Markl M, Wallis W, Harloff A (2011) Reproducibility of flow and wall shear stress analysis using flow-sensitive four-dimensional MRI. J Magn Reson Imaging 33(4):988–994PubMedCrossRef
23.
go back to reference Drexl JB, Hennemuth A, Meier S et al (2012) A tool for the interactive analysis and exploration of in vivo haemodynamics from 4D PC MRI. J Cardiovasc Magn Reson 14(Suppl 1):W70PubMedCentralCrossRef Drexl JB, Hennemuth A, Meier S et al (2012) A tool for the interactive analysis and exploration of in vivo haemodynamics from 4D PC MRI. J Cardiovasc Magn Reson 14(Suppl 1):W70PubMedCentralCrossRef
25.
go back to reference Markl M, Harloff A, Bley TA et al (2007) Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging 25(4):824–831PubMedCrossRef Markl M, Harloff A, Bley TA et al (2007) Time-resolved 3D MR velocity mapping at 3T: improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging 25(4):824–831PubMedCrossRef
26.
go back to reference Hennemuth A, Friman O, Schumann C et al (2011) Fast interactive exploration of 4D MRI flow data. In: Proceedings of medical imaging, SPIE 7964, Lake Buena Vista Hennemuth A, Friman O, Schumann C et al (2011) Fast interactive exploration of 4D MRI flow data. In: Proceedings of medical imaging, SPIE 7964, Lake Buena Vista
27.
go back to reference Bernstein MA, Zhou XJ, Polzin JA et al (1998) Concomitant gradient terms in phase contrast MR: analysis and correction. Magn Reson Med 39(2):300–308PubMedCrossRef Bernstein MA, Zhou XJ, Polzin JA et al (1998) Concomitant gradient terms in phase contrast MR: analysis and correction. Magn Reson Med 39(2):300–308PubMedCrossRef
28.
go back to reference Walker PG, Cranney GB, Scheidegger MB et al (1993) Semiautomated method for noise reduction and background phase error correction in MR phase velocity data. J Magn Reson Imaging 3(3):521–530PubMedCrossRef Walker PG, Cranney GB, Scheidegger MB et al (1993) Semiautomated method for noise reduction and background phase error correction in MR phase velocity data. J Magn Reson Imaging 3(3):521–530PubMedCrossRef
29.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMedCrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMedCrossRef
30.
go back to reference Katsanos H, Giannopoulos S, Kosmidou M et al (2014) Complex atheromatous plaques in the descending aorta and the risk of stroke: a systematic review and meta-analysis. Stroke 45(6):1764–1770PubMedCrossRef Katsanos H, Giannopoulos S, Kosmidou M et al (2014) Complex atheromatous plaques in the descending aorta and the risk of stroke: a systematic review and meta-analysis. Stroke 45(6):1764–1770PubMedCrossRef
Metadata
Title
Accelerated analysis of three-dimensional blood flow of the thoracic aorta in stroke patients
Authors
Thomas Wehrum
Miriam Kams
Laure Schroeder
Johann Drexl
Anja Hennemuth
Andreas Harloff
Publication date
01-12-2014
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 8/2014
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-014-0511-z

Other articles of this Issue 8/2014

The International Journal of Cardiovascular Imaging 8/2014 Go to the issue