Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 3/2014

01-03-2014 | Original paper

Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived reconstructions

Authors: Christos V. Bourantas, Michail I. Papafaklis, Lampros Lakkas, Antonis Sakellarios, Yoshinobu Onuma, Yao-Jun Zhang, Takashi Muramatsu, Roberto Diletti, Paschalis Bizopoulos, Fanis Kalatzis, Katerina K. Naka, Dimitrios I. Fotiadis, Jin Wang, Hector M. Garcia Garcia, Takeshi Kimura, Lampros K. Michalis, Patrick W. Serruys

Published in: The International Journal of Cardiovascular Imaging | Issue 3/2014

Login to get access

Abstract

Intravascular ultrasound (IVUS)-based reconstructions have been traditionally used to examine the effect of endothelial shear stress (ESS) on neointimal formation. The aim of this analysis is to compare the association between ESS and neointimal thickness (NT) in models obtained by the fusion of optical coherence tomography (OCT) and coronary angiography and in the reconstructions derived by the integration of IVUS and coronary angiography. We analyzed data from six patients implanted with an Absorb bioresorbable vascular scaffold that had biplane angiography, IVUS and OCT investigation at baseline and 6 or 12 months follow-up. The IVUS and OCT follow-up data were fused separately with the angiographic data to reconstruct the luminal morphology at baseline and follow-up. Blood flow simulation was performed on the baseline reconstructions and the ESS was related to NT. In the OCT-based reconstructions the ESS were lower compared to the IVUS-based models (1.29 ± 0.66 vs. 1.87 ± 0.66 Pa, P = 0.030). An inverse correlation was noted between the logarithmic transformed ESS and the measured NT in all the OCT-based models which was higher than the correlation reported in five of the six IVUS-derived models (−0.52 ± 0.19 Pa vs. −0.10 ± 0.04, P = 0.028). Fusion of OCT and coronary angiography appears superior to IVUS-based reconstructions; therefore it should be the method of choice for the study of the effect of the ESS on neointimal proliferation.
Literature
1.
go back to reference Gijsen FJ, Oortman RM, Wentzel JJ, Schuurbiers JC, Tanabe K, Degertekin M, Ligthart JM, Thury A, de Feyter PJ, Serruys PW, Slager CJ (2003) Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries. Am J Cardiol 92(11):1325–1328PubMedCrossRef Gijsen FJ, Oortman RM, Wentzel JJ, Schuurbiers JC, Tanabe K, Degertekin M, Ligthart JM, Thury A, de Feyter PJ, Serruys PW, Slager CJ (2003) Usefulness of shear stress pattern in predicting neointima distribution in sirolimus-eluting stents in coronary arteries. Am J Cardiol 92(11):1325–1328PubMedCrossRef
2.
go back to reference Papafaklis MI, Bourantas CV, Theodorakis PE, Katsouras CS, Naka KK, Fotiadis DI, Michalis LK (2010) The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans. JACC Cardiovasc Interv 3(11):1181–1189. doi:10.1016/j.jcin.2010.08.018 PubMedCrossRef Papafaklis MI, Bourantas CV, Theodorakis PE, Katsouras CS, Naka KK, Fotiadis DI, Michalis LK (2010) The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans. JACC Cardiovasc Interv 3(11):1181–1189. doi:10.​1016/​j.​jcin.​2010.​08.​018 PubMedCrossRef
3.
go back to reference Suzuki N, Nanda H, Angiolillo DJ, Bezerra H, Sabate M, Jimenez-Quevedo P, Alfonso F, Macaya C, Bass TA, Ilegbusi OJ, Costa MA (2008) Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus. Int J Cardiovasc Imaging 24(4):357–364. doi:10.1007/s10554-007-9274-0 PubMedCrossRef Suzuki N, Nanda H, Angiolillo DJ, Bezerra H, Sabate M, Jimenez-Quevedo P, Alfonso F, Macaya C, Bass TA, Ilegbusi OJ, Costa MA (2008) Assessment of potential relationship between wall shear stress and arterial wall response after bare metal stent and sirolimus-eluting stent implantation in patients with diabetes mellitus. Int J Cardiovasc Imaging 24(4):357–364. doi:10.​1007/​s10554-007-9274-0 PubMedCrossRef
4.
go back to reference Wentzel JJ, Krams R, Schuurbiers JC, Oomen JA, Kloet J, van Der Giessen WJ, Serruys PW, Slager CJ (2001) Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries. Circulation 103(13):1740–1745PubMedCrossRef Wentzel JJ, Krams R, Schuurbiers JC, Oomen JA, Kloet J, van Der Giessen WJ, Serruys PW, Slager CJ (2001) Relationship between neointimal thickness and shear stress after Wallstent implantation in human coronary arteries. Circulation 103(13):1740–1745PubMedCrossRef
5.
go back to reference Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72(2):237–247. doi:10.1002/ccd.21606 PubMedCrossRef Guagliumi G, Sirbu V (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72(2):237–247. doi:10.​1002/​ccd.​21606 PubMedCrossRef
6.
go back to reference Athanasiou LS, Bourantas CV, Siogkas PK, Sakellarios AI, Exarchos TP, Naka KK, Papafaklis MI, Michalis LK, Prati F, Fotiadis DI (2012) 3D reconstruction of coronary arteries using frequency domain optical coherence tomography images and biplane angiography. Conf Proc IEEE Eng Med Biol Soc 2012:2647–2650. doi:10.1109/EMBC.2012.6346508 PubMed Athanasiou LS, Bourantas CV, Siogkas PK, Sakellarios AI, Exarchos TP, Naka KK, Papafaklis MI, Michalis LK, Prati F, Fotiadis DI (2012) 3D reconstruction of coronary arteries using frequency domain optical coherence tomography images and biplane angiography. Conf Proc IEEE Eng Med Biol Soc 2012:2647–2650. doi:10.​1109/​EMBC.​2012.​6346508 PubMed
7.
go back to reference Papafaklis MI, Bourantas CV, Yonetsu T, Kato K, Kotsia A, Coskun AU, Jia H, Antoniadis AP, Vergallo R, Tsuda M, Fotiadis DI, Feldman CL, Stone PH, Jang IK, Michalis LK (2012) Geometrically accurate three-dimensional coronary artery reconstruction using frequency-domain optical coherence tomography and angiographic data: new opportunities for in vivo endothelial shear stress assessment. JACC Cardiovasc Interv 6:S36 Papafaklis MI, Bourantas CV, Yonetsu T, Kato K, Kotsia A, Coskun AU, Jia H, Antoniadis AP, Vergallo R, Tsuda M, Fotiadis DI, Feldman CL, Stone PH, Jang IK, Michalis LK (2012) Geometrically accurate three-dimensional coronary artery reconstruction using frequency-domain optical coherence tomography and angiographic data: new opportunities for in vivo endothelial shear stress assessment. JACC Cardiovasc Interv 6:S36
8.
go back to reference Serruys PW, Onuma Y, Ormiston JA, de Bruyne B, Regar E, Dudek D, Thuesen L, Smits PC, Chevalier B, McClean D, Koolen J, Windecker S, Whitbourn R, Meredith I, Dorange C, Veldhof S, Miquel-Hebert K, Rapoza R, Garcia-Garcia HM (2010) Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes. Circulation 122(22):2301–2312. doi:10.1161/CIRCULATIONAHA.110.970772 PubMedCrossRef Serruys PW, Onuma Y, Ormiston JA, de Bruyne B, Regar E, Dudek D, Thuesen L, Smits PC, Chevalier B, McClean D, Koolen J, Windecker S, Whitbourn R, Meredith I, Dorange C, Veldhof S, Miquel-Hebert K, Rapoza R, Garcia-Garcia HM (2010) Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes. Circulation 122(22):2301–2312. doi:10.​1161/​CIRCULATIONAHA.​110.​970772 PubMedCrossRef
9.
go back to reference Gomez-Lara J, Radu M, Brugaletta S, Farooq V, Diletti R, Onuma Y, Windecker S, Thuesen L, McClean D, Koolen J, Whitbourn R, Dudek D, Smits PC, Regar E, Veldhof S, Rapoza R, Ormiston JA, Garcia-Garcia HM, Serruys PW (2011) Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold with optical coherence tomography. JACC Cardiovasc Interv 4(9):992–1001. doi:10.1016/j.jcin.2011.03.020 PubMedCrossRef Gomez-Lara J, Radu M, Brugaletta S, Farooq V, Diletti R, Onuma Y, Windecker S, Thuesen L, McClean D, Koolen J, Whitbourn R, Dudek D, Smits PC, Regar E, Veldhof S, Rapoza R, Ormiston JA, Garcia-Garcia HM, Serruys PW (2011) Serial analysis of the malapposed and uncovered struts of the new generation of everolimus-eluting bioresorbable scaffold with optical coherence tomography. JACC Cardiovasc Interv 4(9):992–1001. doi:10.​1016/​j.​jcin.​2011.​03.​020 PubMedCrossRef
10.
go back to reference Bourantas CV, Papafaklis MI, Athanasiou L, Kalatzis FG, Naka KK, Siogkas PK, Takahashi S, Saito S, Fotiadis DI, Feldman CL, Stone PH, Michalis LK (2013) A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans. EuroIntervention 9(5):582–93. doi:10.4244/EIJV9I5A94 Bourantas CV, Papafaklis MI, Athanasiou L, Kalatzis FG, Naka KK, Siogkas PK, Takahashi S, Saito S, Fotiadis DI, Feldman CL, Stone PH, Michalis LK (2013) A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans. EuroIntervention 9(5):582–93. doi:10.​4244/​EIJV9I5A94
13.
go back to reference Stone PH, Saito S, Takahashi S, Makita Y, Nakamura S, Kawasaki T, Takahashi A, Katsuki T, Namiki A, Hirohata A, Matsumura T, Yamazaki S, Yokoi H, Tanaka S, Otsuji S, Yoshimachi F, Honye J, Harwood D, Reitman M, Coskun AU, Papafaklis MI, Feldman CL (2012) Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION Study. Circulation 126(2):172–181. doi:10.1161/CIRCULATIONAHA.112.096438 PubMedCrossRef Stone PH, Saito S, Takahashi S, Makita Y, Nakamura S, Kawasaki T, Takahashi A, Katsuki T, Namiki A, Hirohata A, Matsumura T, Yamazaki S, Yokoi H, Tanaka S, Otsuji S, Yoshimachi F, Honye J, Harwood D, Reitman M, Coskun AU, Papafaklis MI, Feldman CL (2012) Prediction of progression of coronary artery disease and clinical outcomes using vascular profiling of endothelial shear stress and arterial plaque characteristics: the PREDICTION Study. Circulation 126(2):172–181. doi:10.​1161/​CIRCULATIONAHA.​112.​096438 PubMedCrossRef
14.
go back to reference He Y, Duraiswamy N, Frank AO, Moore JE Jr (2005) Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng 127(4):637–647PubMedCrossRef He Y, Duraiswamy N, Frank AO, Moore JE Jr (2005) Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions. J Biomech Eng 127(4):637–647PubMedCrossRef
19.
go back to reference LaDisa JF Jr, Olson LE, Guler I, Hettrick DA, Kersten JR, Warltier DC, Pagel PS (2005) Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. J Appl Physiol 98(3):947–957. doi:10.1152/japplphysiol.0 0872.2004PubMedCrossRef LaDisa JF Jr, Olson LE, Guler I, Hettrick DA, Kersten JR, Warltier DC, Pagel PS (2005) Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models. J Appl Physiol 98(3):947–957. doi:10.​1152/​japplphysiol.​0 0872.2004PubMedCrossRef
20.
21.
go back to reference Serruys PW, Onuma Y, Dudek D, Smits PC, Koolen J, Chevalier B, de Bruyne B, Thuesen L, McClean D, van Geuns RJ, Windecker S, Whitbourn R, Meredith I, Dorange C, Veldhof S, Hebert KM, Sudhir K, Garcia-Garcia HM, Ormiston JA (2011) Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes. J Am Coll Cardiol 58(15):1578–1588. doi:10.1016/j.jacc.2011.05.050 PubMedCrossRef Serruys PW, Onuma Y, Dudek D, Smits PC, Koolen J, Chevalier B, de Bruyne B, Thuesen L, McClean D, van Geuns RJ, Windecker S, Whitbourn R, Meredith I, Dorange C, Veldhof S, Hebert KM, Sudhir K, Garcia-Garcia HM, Ormiston JA (2011) Evaluation of the second generation of a bioresorbable everolimus-eluting vascular scaffold for the treatment of de novo coronary artery stenosis: 12-month clinical and imaging outcomes. J Am Coll Cardiol 58(15):1578–1588. doi:10.​1016/​j.​jacc.​2011.​05.​050 PubMedCrossRef
22.
go back to reference Ormiston JA, Serruys PW, Onuma Y, van Geuns RJ, de Bruyne B, Dudek D, Thuesen L, Smits PC, Chevalier B, McClean D, Koolen J, Windecker S, Whitbourn R, Meredith I, Dorange C, Veldhof S, Hebert KM, Rapoza R, Garcia-Garcia HM (2012) First serial assessment at 6 months and 2 years of the second generation of absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study. Circ Cardiovasc Interv 5(5):620–632. doi:10.1161/CIRCINTERVENTIONS.112.971549 PubMedCrossRef Ormiston JA, Serruys PW, Onuma Y, van Geuns RJ, de Bruyne B, Dudek D, Thuesen L, Smits PC, Chevalier B, McClean D, Koolen J, Windecker S, Whitbourn R, Meredith I, Dorange C, Veldhof S, Hebert KM, Rapoza R, Garcia-Garcia HM (2012) First serial assessment at 6 months and 2 years of the second generation of absorb everolimus-eluting bioresorbable vascular scaffold: a multi-imaging modality study. Circ Cardiovasc Interv 5(5):620–632. doi:10.​1161/​CIRCINTERVENTION​S.​112.​971549 PubMedCrossRef
Metadata
Title
Fusion of optical coherence tomographic and angiographic data for more accurate evaluation of the endothelial shear stress patterns and neointimal distribution after bioresorbable scaffold implantation: comparison with intravascular ultrasound-derived reconstructions
Authors
Christos V. Bourantas
Michail I. Papafaklis
Lampros Lakkas
Antonis Sakellarios
Yoshinobu Onuma
Yao-Jun Zhang
Takashi Muramatsu
Roberto Diletti
Paschalis Bizopoulos
Fanis Kalatzis
Katerina K. Naka
Dimitrios I. Fotiadis
Jin Wang
Hector M. Garcia Garcia
Takeshi Kimura
Lampros K. Michalis
Patrick W. Serruys
Publication date
01-03-2014
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 3/2014
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-014-0374-3

Other articles of this Issue 3/2014

The International Journal of Cardiovascular Imaging 3/2014 Go to the issue