Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 4/2013

01-04-2013 | Original Paper

Application of a new three-dimensional method for the measurement of coronary stent angulation and comparison with conventional methods

Authors: Huaiyu Qiao, Luyue Gai, Minhan Wang, Bin He, Shuoyang Zhang, Xia Yang, Qinhua Jin, Zhiwei Guan

Published in: The International Journal of Cardiovascular Imaging | Issue 4/2013

Login to get access

Abstract

The precision of the measurement of the angulation of coronary stents or lesions using coronary angiography (CA) and computed tomographic angiography (CTA) has not been established, and obtaining a rotating artery tree to measure angulation based on CTA is time-consuming. The aim of this study was to evaluate the utility of a new three-dimensional centerline method that we have developed for the measurement of coronary stent angulation based on CTA and to compare it with other conventional methods. We used the centerline method compacted by means of our new software, the conventional artery rotation method based on CTA and the simple CA method to measure the angulations of phantoms in vitro and stents implanted in patients. The precision and repetition of this new method was compared with those of the other two methods. The angulation values obtained from both the centerline and artery rotation methods based on CTA had high correlation and agreement with the true angulation values measured using a phantom; the 95 % confidence intervals (CIs) for the differences were −0.67° to 0.91° and −0.59° to 2.93°, respectively, while the difference between the value determined using the CA method and the true angulation of the phantoms ranged from 3° to 21.8° (median 8.1°). In clinical coronary stent measurement, the difference between artery rotation and centerline measurement was small (95 % CI −9.0° to 7.6°), and both methods had good repeatability. The time required to complete the measurement was considerably shorter (p < 0.001) using the centerline method than artery rotation method (12.5 ± 1.86 vs. 71.8 ± 13.6 s), while the CA method had poor precision and repeatability in the measurement of clinical stent angulation relative to the methods based on CTA (95 % CI −14.7° to 21.7°). Our three-dimensional centerline method based on CTA for the measurement of angulation was reliable and easy to implement in both clinical and basic research image analysis, and the centerline and conventional artery rotation methods can be used interchangeably. In addition, the value obtained for the coronary stent angulation using the CA method had a large bias.
Literature
1.
go back to reference Colkesen AY, Baltali M, Acil T et al (2007) Coronary and systemic stent embolization during percutaneous coronary interventions: a single center experience. Int Heart J 48:129–136PubMedCrossRef Colkesen AY, Baltali M, Acil T et al (2007) Coronary and systemic stent embolization during percutaneous coronary interventions: a single center experience. Int Heart J 48:129–136PubMedCrossRef
2.
go back to reference Popma JJ, Tiroch K, Almonacid A et al (2009) Qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation. Am J Cardiol 103:923–929PubMedCrossRef Popma JJ, Tiroch K, Almonacid A et al (2009) Qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation. Am J Cardiol 103:923–929PubMedCrossRef
3.
go back to reference Shen ZJ, Brugaletta S, Garcia–Garcia HM et al (2012) Comparison of plaque prolapse in consecutive patients treated with Xience V and Taxus Liberte stents. Int J Cardiovasc Imag. 28:23–31CrossRef Shen ZJ, Brugaletta S, Garcia–Garcia HM et al (2012) Comparison of plaque prolapse in consecutive patients treated with Xience V and Taxus Liberte stents. Int J Cardiovasc Imag. 28:23–31CrossRef
4.
go back to reference Umeda H, Gochi T, Iwase M et al (2009) Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation. Int J Cardiol 133:321–326PubMedCrossRef Umeda H, Gochi T, Iwase M et al (2009) Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation. Int J Cardiol 133:321–326PubMedCrossRef
5.
go back to reference Davlouros PA, Chefneux C, Xanthopoulou I et al (2012) Flat panel digital detector cinefluoroscopy late following SES or BMS implantation for detection of coronary stent fracture in asymptomatic patients. Int J Cardiol 156:277–282PubMedCrossRef Davlouros PA, Chefneux C, Xanthopoulou I et al (2012) Flat panel digital detector cinefluoroscopy late following SES or BMS implantation for detection of coronary stent fracture in asymptomatic patients. Int J Cardiol 156:277–282PubMedCrossRef
6.
go back to reference Papathanasiou M, Zacharioglou E, Davlouros P et al (2010) Non-invasive assessment of stent fracture with the stent boost technique. J Am Coll Cardiol 55:10 Suppl 1 (A135.E1263) Papathanasiou M, Zacharioglou E, Davlouros P et al (2010) Non-invasive assessment of stent fracture with the stent boost technique. J Am Coll Cardiol 55:10 Suppl 1 (A135.E1263)
7.
go back to reference Ino Y, Toyoda Y, Tanaka A et al (2009) Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation. Circ J 73:2036–2041PubMedCrossRef Ino Y, Toyoda Y, Tanaka A et al (2009) Predictors and prognosis of stent fracture after sirolimus-eluting stent implantation. Circ J 73:2036–2041PubMedCrossRef
8.
go back to reference Wahle A, Lopez JJ, Olszewski ME et al (2006) Plaque development, vessel curvature, and wall shear stress in coronary arteries assessed by X-ray angiography and intravascular ultrasound. Med Image Anal 10:615–631PubMedCrossRef Wahle A, Lopez JJ, Olszewski ME et al (2006) Plaque development, vessel curvature, and wall shear stress in coronary arteries assessed by X-ray angiography and intravascular ultrasound. Med Image Anal 10:615–631PubMedCrossRef
9.
go back to reference Katritsis DG, Pantos I, Korovesis S et al (2009) Three-dimensional analysis of vulnerable segments in the left anterior descending artery. Coron Artery Dis 20:199–206PubMedCrossRef Katritsis DG, Pantos I, Korovesis S et al (2009) Three-dimensional analysis of vulnerable segments in the left anterior descending artery. Coron Artery Dis 20:199–206PubMedCrossRef
10.
go back to reference Christensen KN, Harris SR, Froemming AT et al (2010) Anatomic assessment of the bifurcation of the left main coronary artery using multidetector computed tomography. Surg Radiol Anat 32:903–909PubMedCrossRef Christensen KN, Harris SR, Froemming AT et al (2010) Anatomic assessment of the bifurcation of the left main coronary artery using multidetector computed tomography. Surg Radiol Anat 32:903–909PubMedCrossRef
11.
go back to reference Pflederer T, Ludwig J, Ropers D et al (2006) Measurement of coronary artery bifurcation angles by multidetector computed tomography. Investig Radiol 41:793–798CrossRef Pflederer T, Ludwig J, Ropers D et al (2006) Measurement of coronary artery bifurcation angles by multidetector computed tomography. Investig Radiol 41:793–798CrossRef
12.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMedCrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1(8476):307–310PubMedCrossRef
13.
go back to reference Bland JM, Altman DG (2003) Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol 22:85–93PubMedCrossRef Bland JM, Altman DG (2003) Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol 22:85–93PubMedCrossRef
14.
go back to reference Andriotis A, Zifan A, Gavaises M et al (2008) A new method of three-dimensional coronary artery reconstruction from X-ray angiography: validation against a virtual phantom and multislice computed tomography. Catheter Cardiovasc Interv 71:28–43PubMedCrossRef Andriotis A, Zifan A, Gavaises M et al (2008) A new method of three-dimensional coronary artery reconstruction from X-ray angiography: validation against a virtual phantom and multislice computed tomography. Catheter Cardiovasc Interv 71:28–43PubMedCrossRef
15.
go back to reference Gradaus R, Mathies K, Breithardt G et al (2006) Clinical assessment of a new real time 3D quantitative coronary angiography system: evaluation in stented vessel segments. Catheter Cardiovasc Interv 68:44–49PubMedCrossRef Gradaus R, Mathies K, Breithardt G et al (2006) Clinical assessment of a new real time 3D quantitative coronary angiography system: evaluation in stented vessel segments. Catheter Cardiovasc Interv 68:44–49PubMedCrossRef
Metadata
Title
Application of a new three-dimensional method for the measurement of coronary stent angulation and comparison with conventional methods
Authors
Huaiyu Qiao
Luyue Gai
Minhan Wang
Bin He
Shuoyang Zhang
Xia Yang
Qinhua Jin
Zhiwei Guan
Publication date
01-04-2013
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 4/2013
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0157-7

Other articles of this Issue 4/2013

The International Journal of Cardiovascular Imaging 4/2013 Go to the issue