Quantitative assessment of glucose metabolism in the vessel wall of abdominal aortic aneurysms: correlation with histology and role of partial volume correction

Authors: Christian Reeps, Ralph A. Bundschuh, Jaroslav Pellisek, Michael Herz, Sandra van Marwick, Markus Schwaiger, Hans-Henning Eckstein, Stephan G. Nekolla, Markus Essler

Published in: The International Journal of Cardiovascular Imaging | Issue 2/2013

Login to get access

Abstract

Inflammatory-proteolytic processes in the vessel wall are essential in the pathophysiology of abdominal aortic aneurysm (AAA). It has been demonstrated that, 18F-FDG-PET/CT may be useful for detection of pathological wall metabolism and therefore risk stratification. Quantification of the FDG-uptake in AAA wall is hampered by partial-volume (PV)-effects. For correction and accurate quantitative 18F-FDG-uptake analysis we designed and validated a novel IDL-based software in correlation to phantom studies, histopathology and clinical presentation of AAA patients. For in vivo studies 23 patients with symptomatic and asymptomatic AAA underwent 18F-FDG-PET/CT before surgery. In areas with 18F-FDG-uptake the maximum and mean standardized uptake values in the vessel wall with (PVC-SUVmax, PVC-SUVmean) and without (SUVmax, SUVmean) PV-correction were determined. Results were correlated with clinical presentation, corresponding macrophage-infiltration and MMP-2- and -9-expression in surgical specimens. In patients, SUVmax, SUVmean as well as PVC-SUVmax or PVC-SUVmean enabled a highly significant (p < 0.005) discrimination of symptomatic and asymptomatic AAA. Uncorrected and corrected SUVs showed comparable correlations with macrophage-infiltration and MMP-9 expression. No correlation of 18F-FDG-uptake and MMP-2 was found. In vivo correlations of detected FDG-uptake with clinical and histological results showed comparable results for corrected and uncorrected SUVs. PV-correction is not mandatory for qualitative clinical assessment of glucose metabolism in the vessel wall of AAA-patients but may be necessary to establish quantitative cut off values to stratify patients for aneurysm repair.
Literature
1.
go back to reference Bengtson H, Sonesson B, Bergquist D (1996) Incidence and prevalence of abdominal aortic aneurysms estimated by necropsy studies and population screening by ultrasound. Ann N Y Acad Sci 800:1–24CrossRef Bengtson H, Sonesson B, Bergquist D (1996) Incidence and prevalence of abdominal aortic aneurysms estimated by necropsy studies and population screening by ultrasound. Ann N Y Acad Sci 800:1–24CrossRef
2.
go back to reference Patel MI, Hardmann DT, Fisher CM et al (1995) Current views on the pathogenesis of abdominal aortic aneurysms. J Am Coll Surg 181:371–382PubMed Patel MI, Hardmann DT, Fisher CM et al (1995) Current views on the pathogenesis of abdominal aortic aneurysms. J Am Coll Surg 181:371–382PubMed
3.
go back to reference Vorp DA, Vande Geest JP (2005) Biomechanical determinants of abdominal aortic aneurysm rupture. Arterioscler Thromb Vasc Biol 2:1558–1566 Vorp DA, Vande Geest JP (2005) Biomechanical determinants of abdominal aortic aneurysm rupture. Arterioscler Thromb Vasc Biol 2:1558–1566
4.
5.
go back to reference Chaikof EL, Brewster DC, Dalman RL et al (2009) The care of patients with an abdominal aortic aneurysm: the Society for Vascular Surgery practice guidelines. J Vasc Surg 50(4 Suppl):S2–S49PubMedCrossRef Chaikof EL, Brewster DC, Dalman RL et al (2009) The care of patients with an abdominal aortic aneurysm: the Society for Vascular Surgery practice guidelines. J Vasc Surg 50(4 Suppl):S2–S49PubMedCrossRef
6.
go back to reference Brewster DC (2001) Presidential address: what would you do if it were your father? Reflections on endovascular abdominal aortic aneurysm repair. J Vasc Surg 33:1139–1147PubMed Brewster DC (2001) Presidential address: what would you do if it were your father? Reflections on endovascular abdominal aortic aneurysm repair. J Vasc Surg 33:1139–1147PubMed
7.
go back to reference Conrad MF, Crawford RS, Pedraza JD et al (2007) Long-term durability of open abdominal aortic aneurysm repair. J Vasc Surg 46:669–675PubMedCrossRef Conrad MF, Crawford RS, Pedraza JD et al (2007) Long-term durability of open abdominal aortic aneurysm repair. J Vasc Surg 46:669–675PubMedCrossRef
8.
go back to reference Reeps C, Essler M, Pelisek J et al (2008) Increased [18F]fluorodeoxyglucose uptake in abdominal aortic aneurysms in positron emission/computed tomography is associated with inflammation, aortic wall instability, and acute symptoms. J Vasc Surg 48:417–423PubMedCrossRef Reeps C, Essler M, Pelisek J et al (2008) Increased [18F]fluorodeoxyglucose uptake in abdominal aortic aneurysms in positron emission/computed tomography is associated with inflammation, aortic wall instability, and acute symptoms. J Vasc Surg 48:417–423PubMedCrossRef
9.
go back to reference Reeps C, Gee MW, Maier A et al (2009) Glucose metabolism in the vessel wall correlates with mechanical instability and inflammatory changes in a patient with a growing aneurysm of the abdominal aorta. Circ Cardiovasc Imaging 2:507–509PubMedCrossRef Reeps C, Gee MW, Maier A et al (2009) Glucose metabolism in the vessel wall correlates with mechanical instability and inflammatory changes in a patient with a growing aneurysm of the abdominal aorta. Circ Cardiovasc Imaging 2:507–509PubMedCrossRef
10.
go back to reference Defawe OD, Hustinx R, Defraigne JO et al (2005) Distribution of F-18 fluorodeoxyglucose (F-18 FDG) in abdominal aortic aneurysm: high accumulation in macrophages seen on PET imaging and immunohistology. Clin Nucl Med 30:340–341PubMedCrossRef Defawe OD, Hustinx R, Defraigne JO et al (2005) Distribution of F-18 fluorodeoxyglucose (F-18 FDG) in abdominal aortic aneurysm: high accumulation in macrophages seen on PET imaging and immunohistology. Clin Nucl Med 30:340–341PubMedCrossRef
11.
go back to reference Bazañez-Borgert M, Bundschuh RA, Herz M et al (2008) Radioactive spheres without inactive wall for lesion simulation in PET. Z Med Phys 18:37–42PubMedCrossRef Bazañez-Borgert M, Bundschuh RA, Herz M et al (2008) Radioactive spheres without inactive wall for lesion simulation in PET. Z Med Phys 18:37–42PubMedCrossRef
12.
go back to reference Choke E, Cockerill G, Wilson WR et al (2005) A review of biological factors implicated in abdominal aortic aneurysm rupture. Eur J Vasc Endovasc Surg 30:227–244PubMedCrossRef Choke E, Cockerill G, Wilson WR et al (2005) A review of biological factors implicated in abdominal aortic aneurysm rupture. Eur J Vasc Endovasc Surg 30:227–244PubMedCrossRef
13.
go back to reference Turner GH, Olzinski AR, Bernard RE et al. (2009) Assessment of macrophage infiltration in a murine model of abdominal aortic aneurysm. J Magn Reson Imaging 30:455–460 Turner GH, Olzinski AR, Bernard RE et al. (2009) Assessment of macrophage infiltration in a murine model of abdominal aortic aneurysm. J Magn Reson Imaging 30:455–460
14.
go back to reference Rudd JH, Warburton EA, Fryer TD et al (2002) Imaging atherosclerotic plaque inflammation with [18F]-fluorodeoxyglucose positron emission tomography. Circulation 105:2708–2711PubMedCrossRef Rudd JH, Warburton EA, Fryer TD et al (2002) Imaging atherosclerotic plaque inflammation with [18F]-fluorodeoxyglucose positron emission tomography. Circulation 105:2708–2711PubMedCrossRef
Metadata
Title
Quantitative assessment of glucose metabolism in the vessel wall of abdominal aortic aneurysms: correlation with histology and role of partial volume correction
Authors
Christian Reeps
Ralph A. Bundschuh
Jaroslav Pellisek
Michael Herz
Sandra van Marwick
Markus Schwaiger
Hans-Henning Eckstein
Stephan G. Nekolla
Markus Essler
Publication date
01-02-2013
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 2/2013
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0090-9

Other articles of this Issue 2/2013

The International Journal of Cardiovascular Imaging 2/2013 Go to the issue