Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 2/2012

01-02-2012 | Original Paper

Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage

Authors: G. J. Ughi, T. Adriaenssens, K. Onsea, P. Kayaert, C. Dubois, P. Sinnaeve, M. Coosemans, W. Desmet, J. D’hooge

Published in: The International Journal of Cardiovascular Imaging | Issue 2/2012

Login to get access

Abstract

The implantation of intracoronary stents is currently the standard approach for the treatment of coronary atherosclerotic disease. The widespread adoption of this technology has boosted an intensive research activity in this domain, with continuous improvements in the design of these devices, aiming at reducing problems of restenosis (re-narrowing of the stented segment) and thrombosis (sudden occlusion due to thrombus formation). Recently, a new, light-based intracoronary imaging modality, optical coherence tomography (OCT), was developed and introduced into clinical practice. Due to its very high axial resolution (10–15 μm), it allows for in vivo evaluation of both stent strut apposition and neointima coverage (a marker of healing of the treated segment). As such, it provides valuable information on proper stent deployment, on the behaviour of different stent types in-vivo and on the effect of new types of stents (e.g. drug-eluting stents) on vessel wall healing. However, the major drawback of the current OCT methodology is that analysis of these images requires a tremendous amount of—currently manual—post-processing. In this manuscript, an algorithm is presented that allows for fully automated analysis of stent strut apposition and coverage in coronary arteries. The vessel lumen and stent struts are automatically detected and segmented through analysis of the intensity profiles of the A-lines. From these data, apposition and coverage can then be measured automatically. The algorithm was validated using manual assessments by two experienced operators as a reference. High Pearson’s correlation coefficients were found (R = 0.96–0.97) between the automated and manual measurements while Bland–Altman analysis showed no significant bias with good limits of agreement. As such, it was shown that the presented algorithm provides a robust and fast tool to automatically estimate apposition and coverage of stent struts in in-vivo OCT pullbacks. This will be important for the integration of this technology in clinical routine and for the analysis of datasets of larger clinical trials.
Literature
1.
go back to reference Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon D (2009) Intracoronary optical coherence tomography: a comprehensive review. JACC Cardiovasc Interv 2:1035–1046 Bezerra HG, Costa MA, Guagliumi G, Rollins AM, Simon D (2009) Intracoronary optical coherence tomography: a comprehensive review. JACC Cardiovasc Interv 2:1035–1046
2.
go back to reference Prati F, Regard E, Mintz GS, Arbustini E, Di Mario C, Jang I, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW J (2009) Expert review document on methodology, terminology, and clinical application of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415PubMedCrossRef Prati F, Regard E, Mintz GS, Arbustini E, Di Mario C, Jang I, Akasaka T, Costa M, Guagliumi G, Grube E, Ozaki Y, Pinto F, Serruys PW J (2009) Expert review document on methodology, terminology, and clinical application of optical coherence tomography: physical principles, methodology of image acquisition, and clinical application for assessment of coronary arteries and atherosclerosis. Eur Heart J 31:401–415PubMedCrossRef
3.
go back to reference Terashima M, Rathore S, Suzuki Y, Nakayama Y, Kaneda H, Nasu H, Habara M, Katoh O, Suzuki T (2009) Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography. J Invasive Cardiol 21:602–605 Terashima M, Rathore S, Suzuki Y, Nakayama Y, Kaneda H, Nasu H, Habara M, Katoh O, Suzuki T (2009) Accuracy and reproducibility of stent-strut thickness determined by optical coherence tomography. J Invasive Cardiol 21:602–605
4.
go back to reference Tearney G J et al (2008) Three dimensional coronary artery microscopy by intra coronary optical coherence tomography. JACC Cardiovasc Imaging 1:752–761 Tearney G J et al (2008) Three dimensional coronary artery microscopy by intra coronary optical coherence tomography. JACC Cardiovasc Imaging 1:752–761
5.
go back to reference Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, Mintz G S, Nagata S (2006) Incomplete neointima coverage of Sirolimus-eluting stents angioscopic findings. JACC Cardiovasc Interv 47:2108–2111 Kotani J, Awata M, Nanto S, Uematsu M, Oshima F, Minamiguchi H, Mintz G S, Nagata S (2006) Incomplete neointima coverage of Sirolimus-eluting stents angioscopic findings. JACC Cardiovasc Interv 47:2108–2111
6.
go back to reference Hong M et al (2004) Incidence, mechanism, predictors and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 109:881–886PubMedCrossRef Hong M et al (2004) Incidence, mechanism, predictors and long-term prognosis of late stent malapposition after bare-metal stent implantation. Circulation 109:881–886PubMedCrossRef
7.
go back to reference Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Herman KG, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:435–441CrossRef Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Herman KG, Virmani R (2007) Pathological correlates of late drug-eluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:435–441CrossRef
8.
go back to reference G Guagliumi and V Sirbu (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247 G Guagliumi and V Sirbu (2008) Optical coherence tomography: high resolution intravascular imaging to evaluate vascular healing after coronary stenting. Catheter Cardiovasc Interv 72:237–247
9.
go back to reference Murata A et al (2010) Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging 3:76–84 Murata A et al (2010) Accuracy of optical coherence tomography in the evaluation of neointimal coverage after stent implantation. JACC Cardiovasc Imaging 3:76–84
10.
go back to reference Unal G, Gurmeric S and Carlier S G (2009) Stent implant follow-up in intravascular optical coherence tomography images. Int J Cardiovasc Imaging. 6:1569–1573 Unal G, Gurmeric S and Carlier S G (2009) Stent implant follow-up in intravascular optical coherence tomography images. Int J Cardiovasc Imaging. 6:1569–1573
11.
go back to reference Sawada T et al (2009) Factors that influence measurement and accurate evaluation of stent apposition by optical coherence tomography. Cardiovasc interv 73:1841–1847 Sawada T et al (2009) Factors that influence measurement and accurate evaluation of stent apposition by optical coherence tomography. Cardiovasc interv 73:1841–1847
12.
go back to reference Paul Dierckx (1993) Curve and surface fitting with splines, monograph on numerical analysis. Oxford Science Publication, Oxford, pp 75–118 Paul Dierckx (1993) Curve and surface fitting with splines, monograph on numerical analysis. Oxford Science Publication, Oxford, pp 75–118
13.
go back to reference WK Pratt (2001) Digital image processing: PIKS inside, 3rd edn. Wiley Inc, Hoboken, New Jersey, pp 393–398, 647–672 WK Pratt (2001) Digital image processing: PIKS inside, 3rd edn. Wiley Inc, Hoboken, New Jersey, pp 393–398, 647–672
Metadata
Title
Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage
Authors
G. J. Ughi
T. Adriaenssens
K. Onsea
P. Kayaert
C. Dubois
P. Sinnaeve
M. Coosemans
W. Desmet
J. D’hooge
Publication date
01-02-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 2/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-011-9824-3

Other articles of this Issue 2/2012

The International Journal of Cardiovascular Imaging 2/2012 Go to the issue