Published in: The International Journal of Cardiovascular Imaging 1/2012

01-01-2012 | Original Paper

Computed tomography angiography in children with cardiovascular disease: low dose techniques and image quality

Authors: S. Bruce Greenberg, Sadaf Bhutta, Leah Braswell, Frandics Chan

Published in: The International Journal of Cardiovascular Imaging | Issue 1/2012

Login to get access

Abstract

Dose reduction techniques for computed tomography angiography (CTA) in children with cardiovascular diseases have the potential of reducing risks of radiation-induced cancer. To evaluate effectiveness of these techniques, both radiation dose and image quality must be compared. While clinically practical methods of estimating effective dose are available, there are no generally accepted metrics for the assessment of image quality in CTA. We introduce a measurable and reproducible image quality index, CTA QI. Using this index, along with calculated effective dose, we test the hypothesis that volume scan CTA delivers comparable image quality at substantially reduced radiation dose when compared to helical CTA. CTA QI is a measure of intraluminal contrast variation in three-dimensions, and it is calculated from standardized measurements of means and standard deviations of Hounsfield units in the thoracic descending aorta. From institutional database, 83 studies of CTA for thoracic cardiovascular diseases were retrospectively identified. CTA QI values were independently measured by two radiologists and compared using correlation. CTA QI and DLP-derived effective dose were compared for the following groups: non-cardiac gated wide-detector and helical CTA, ECG-synchronized retrospective wide-detector and helical CTA, ECG-synchronized wide detector retrospective and target technique CTA. Statistical significance was evaluated with the Student—t test. The correlations of CTA QI values between the radiologists were 0.83 and 0.92 for non-gated studies and ECG-synchronized studies respectively. Comparing non-gated volume scan CTA to helical CTA, there was a radiation dose reduction of 69% (P < 0.0001) without a significant change in CTA QI (1.4 ± 1.0 vs. 1.9 ± 1.4, P = 0.13). Comparing retrospective ECG-synchronized wide-detector CTA to helical CTA, there was a radiation dose reduction of 46% (P < 0.0001) with and improvement in CTA QI (1.0 ± 0.8 vs. 3.7 ± 3.4, P < 0.01). Comparing ECG-synchronized wide-detector target CTA to retrospective CTA, there was a radiation dose reduction of 68% (P < 0.0001, but at the cost of a significant reduction in CTA QI (2.0 ± 1.0 vs. 0.8 ± 0.4, P < 0.0044). CTA QI is a simple, reproducible metric of image quality suited for comparing CTA studies. Using this quality index, we establish that CTA performed with wide-detector scan techniques can yield substantially lower radiation dose without compromising diagnostic imaging quality. A wide-detector target technique can further reduce effective dose compared to wide-detector retrospective ECG-synchronization, but with a reduction in image quality.
Literature
1.
go back to reference Kim J, Newman B (2010) Evaluation of a radiation dose reduction strategy for pediatric chest CT. AJR 194:1188–1193PubMedCrossRef Kim J, Newman B (2010) Evaluation of a radiation dose reduction strategy for pediatric chest CT. AJR 194:1188–1193PubMedCrossRef
2.
go back to reference Henzler T, Hanley M, Arnoldi E et al (2010) Practical strategies for low radiation dose cardiac computed tomography. J Thorac Imaging 25:213–220PubMedCrossRef Henzler T, Hanley M, Arnoldi E et al (2010) Practical strategies for low radiation dose cardiac computed tomography. J Thorac Imaging 25:213–220PubMedCrossRef
3.
go back to reference Hellinger JC, Pena A, Poon M et al (2010) Pediatric computed tomographic angiography: imaging the cardiovascular system gently. Radiol Clin North Am 48:439–467PubMedCrossRef Hellinger JC, Pena A, Poon M et al (2010) Pediatric computed tomographic angiography: imaging the cardiovascular system gently. Radiol Clin North Am 48:439–467PubMedCrossRef
4.
go back to reference Kubo T, Lin PP, Stiller W et al (2008) Radiation dose reduction in chest CT: a review. AJR 190:335–343PubMedCrossRef Kubo T, Lin PP, Stiller W et al (2008) Radiation dose reduction in chest CT: a review. AJR 190:335–343PubMedCrossRef
6.
go back to reference Sun Z, Ng C (2010) Dual-source CT angiography in aortic stent grafting: an in vitro aorta phantom study of image noise and radiation dose. Acad Radiol 17:884–893PubMedCrossRef Sun Z, Ng C (2010) Dual-source CT angiography in aortic stent grafting: an in vitro aorta phantom study of image noise and radiation dose. Acad Radiol 17:884–893PubMedCrossRef
7.
go back to reference Heyer CM, Mohr PS, Lemburg SP et al (2007) Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology 245:577–582PubMedCrossRef Heyer CM, Mohr PS, Lemburg SP et al (2007) Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: prospective randomized study. Radiology 245:577–582PubMedCrossRef
8.
go back to reference Coursey C, Frush DP, Yoshizumi T et al (2008) Pediatric chest MDCT using tube current modulation: effect of radiation dose with breast shielding. AJR 190:W54–W61PubMedCrossRef Coursey C, Frush DP, Yoshizumi T et al (2008) Pediatric chest MDCT using tube current modulation: effect of radiation dose with breast shielding. AJR 190:W54–W61PubMedCrossRef
9.
go back to reference Thomas KE, Wang B (2008) Age-specific effective doses for pediatric MSCT examinations at a large children’s hospital using DLP conversion coefficients: a simple estimation method. Pedatr Radiol 38:645–656CrossRef Thomas KE, Wang B (2008) Age-specific effective doses for pediatric MSCT examinations at a large children’s hospital using DLP conversion coefficients: a simple estimation method. Pedatr Radiol 38:645–656CrossRef
10.
go back to reference Berrington de Gonzalez A, Mahesh M, Kim K et al (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169:2071–2077PubMedCrossRef Berrington de Gonzalez A, Mahesh M, Kim K et al (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169:2071–2077PubMedCrossRef
11.
go back to reference Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357:2277–2284PubMedCrossRef
12.
go back to reference Arch ME, Frush DP (2008) Pediatric body MDCT: a 5-year follow-up survey of scanning parameters used by pediatric radiologists. AJR Am J Roentgenol 191:611–617PubMedCrossRef Arch ME, Frush DP (2008) Pediatric body MDCT: a 5-year follow-up survey of scanning parameters used by pediatric radiologists. AJR Am J Roentgenol 191:611–617PubMedCrossRef
13.
go back to reference Preston DL, Pierce DA, Shimizu Y et al (2004) Effect of recent changes in atomic bomb survivor dosimetry on cancer mortality risk estimates. Radiat Res 162:377–389PubMedCrossRef Preston DL, Pierce DA, Shimizu Y et al (2004) Effect of recent changes in atomic bomb survivor dosimetry on cancer mortality risk estimates. Radiat Res 162:377–389PubMedCrossRef
Metadata
Title
Computed tomography angiography in children with cardiovascular disease: low dose techniques and image quality
Authors
S. Bruce Greenberg
Sadaf Bhutta
Leah Braswell
Frandics Chan
Publication date
01-01-2012
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 1/2012
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-010-9782-1

Other articles of this Issue 1/2012

The International Journal of Cardiovascular Imaging 1/2012 Go to the issue