Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 7/2008

01-10-2008 | Original Paper

Intra- and interobserver variability in detection and assessment of calcified and noncalcified coronary artery plaques using 64-slice computed tomography

Variability in coronary plaque measurement using MSCT

Authors: Hans Hoffmann, Katja Frieler, Bernd Hamm, Marc Dewey

Published in: The International Journal of Cardiovascular Imaging | Issue 7/2008

Login to get access

Abstract

Objective Multislice computed tomography (MSCT) is an emerging noninvasive technique for detecting coronary plaques. The present study investigated agreement in the detection and characterization of coronary plaques and reproducibility of volumetric analysis. Methods A total of 20 patients underwent MSCT coronary angiography using 64 * 0.5 mm detector collimation. Two readers independently visually evaluated all MSCT datasets for the presence of coronary plaques (n = 82 in 262 coronary segments) and then classified them as calcified, mixed and noncalcified. In addition, one of the readers also manually determined total volumes as well as calcified and noncalcified volumes of each plaque. After a period of at least 4 weeks the complete volumetric analysis was repeated. Results Interobserver agreement was good for detection of coronary plaques on the segment level (weighted κ = 0.88, 95% CI [0.76, 0.95]). However, there was only moderate interobserver agreement for plaques classification (unweighted κ = 0.45, 95% CI [0.35, 0.61]). Intraobserver agreement was good for plaque detection on segment level (weighted κ = 0.90, 95% CI [0.77, 0.96]), while it was moderate with respect to their characterization (unweighted κ = 0.65, 95% CI [0.55, 0.80]). There was moderate reproducibility for total plaque volume (limits of agreement = ±6 mm3 at a mean measured volume of 10 mm3 and = ±28 mm3 at a mean measured volume of 100 mm3). Variation of relative differences significantly decreased for total volume and noncalcified volume with increasing mean volume. Conclusions Detection and volumetry of plaques by means of MSCT shows good to moderate reproducibility. Agreement of volume measurements depends on plaque size. Variation of relative differences decrease with increasing mean plaque volume.
Literature
1.
go back to reference Tunstall-Pedoe H, Kuulasmaa K, Mahonen M et al (1999) Contribution of trends in survival and coronary-event rates to changes in coronary heart disease mortality: 10-year results from 37 WHO MONICA project populations. Monitoring trends and determinants in cardiovascular disease. Lancet 353:1547–1557PubMedCrossRef Tunstall-Pedoe H, Kuulasmaa K, Mahonen M et al (1999) Contribution of trends in survival and coronary-event rates to changes in coronary heart disease mortality: 10-year results from 37 WHO MONICA project populations. Monitoring trends and determinants in cardiovascular disease. Lancet 353:1547–1557PubMedCrossRef
2.
go back to reference Smith SC Jr, Feldman TE, Hirshfeld JW Jr et al (2006) ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to update 2001 guidelines for percutaneous coronary intervention). Circulation 113:e166–e286PubMedCrossRef Smith SC Jr, Feldman TE, Hirshfeld JW Jr et al (2006) ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to update 2001 guidelines for percutaneous coronary intervention). Circulation 113:e166–e286PubMedCrossRef
3.
4.
go back to reference Leber AW, Knez A, Becker A et al (2005) Visualising noncalcified coronary plaques by CT. Int J Cardiovasc Imaging 21:55–61PubMedCrossRef Leber AW, Knez A, Becker A et al (2005) Visualising noncalcified coronary plaques by CT. Int J Cardiovasc Imaging 21:55–61PubMedCrossRef
5.
go back to reference Kopp AF, Schroeder S, Baumbach A et al (2001) Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 11:1607–1611PubMedCrossRef Kopp AF, Schroeder S, Baumbach A et al (2001) Non-invasive characterisation of coronary lesion morphology and composition by multislice CT: first results in comparison with intracoronary ultrasound. Eur Radiol 11:1607–1611PubMedCrossRef
6.
go back to reference Stary HC, Chandler AB, Dinsmore RE et al (1995) A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Arterioscler Thromb Vasc Biol 15:1512–1531PubMed Stary HC, Chandler AB, Dinsmore RE et al (1995) A definition of advanced types of atherosclerotic lesions and a histological classification of atherosclerosis. A report from the Committee on Vascular Lesions of the Council on Arteriosclerosis, American Heart Association. Arterioscler Thromb Vasc Biol 15:1512–1531PubMed
7.
go back to reference Stary HC (2000) Natural history and histological classification of atherosclerotic lesions: an update. Arterioscler Thromb Vasc Biol 20:1177–1178PubMed Stary HC (2000) Natural history and histological classification of atherosclerotic lesions: an update. Arterioscler Thromb Vasc Biol 20:1177–1178PubMed
8.
go back to reference Schroeder S, Kopp AF, Baumbach A et al (2001) Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol 37:1430–1435PubMedCrossRef Schroeder S, Kopp AF, Baumbach A et al (2001) Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomography. J Am Coll Cardiol 37:1430–1435PubMedCrossRef
9.
go back to reference Rodriguez-Granillo GA, Agostoni P, Garcia-Garcia HM et al (2007) Meta-analysis of the studies assessing temporal changes in coronary plaque volume using intravascular ultrasound. Am J Cardiol 99:5–10PubMedCrossRef Rodriguez-Granillo GA, Agostoni P, Garcia-Garcia HM et al (2007) Meta-analysis of the studies assessing temporal changes in coronary plaque volume using intravascular ultrasound. Am J Cardiol 99:5–10PubMedCrossRef
10.
go back to reference Rodriguez-Granillo GA, Vaina S, Garcia-Garcia HM et al (2006) Reproducibility of intravascular ultrasound radiofrequency data analysis: implications for the design of longitudinal studies. Int J Cardiovasc Imaging 22:621–631PubMedCrossRef Rodriguez-Granillo GA, Vaina S, Garcia-Garcia HM et al (2006) Reproducibility of intravascular ultrasound radiofrequency data analysis: implications for the design of longitudinal studies. Int J Cardiovasc Imaging 22:621–631PubMedCrossRef
11.
go back to reference Leber AW, Knez A, White CW et al (2003) Composition of coronary atherosclerotic plaques in patients with acute myocardial infarction and stable angina pectoris determined by contrast-enhanced multislice computed tomography. Am J Cardiol 91:714–718PubMedCrossRef Leber AW, Knez A, White CW et al (2003) Composition of coronary atherosclerotic plaques in patients with acute myocardial infarction and stable angina pectoris determined by contrast-enhanced multislice computed tomography. Am J Cardiol 91:714–718PubMedCrossRef
12.
go back to reference Hoffmann U, Moselewski F, Nieman K et al (2006) Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol 47:1655–1662PubMedCrossRef Hoffmann U, Moselewski F, Nieman K et al (2006) Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography. J Am Coll Cardiol 47:1655–1662PubMedCrossRef
13.
go back to reference Burgstahler C, Reimann A, Beck T et al (2007) Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography: results of the New Age II Pilot Study. Invest Radiol 42:189–195PubMedCrossRef Burgstahler C, Reimann A, Beck T et al (2007) Influence of a lipid-lowering therapy on calcified and noncalcified coronary plaques monitored by multislice detector computed tomography: results of the New Age II Pilot Study. Invest Radiol 42:189–195PubMedCrossRef
14.
go back to reference Dewey M, Laule M, Krug L et al (2004) Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol 39:223–229PubMedCrossRef Dewey M, Laule M, Krug L et al (2004) Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses. Invest Radiol 39:223–229PubMedCrossRef
15.
go back to reference Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Rofo 178:600–604PubMed Dewey M, Hoffmann H, Hamm B (2006) Multislice CT coronary angiography: effect of sublingual nitroglycerine on the diameter of coronary arteries. Rofo 178:600–604PubMed
16.
go back to reference Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed Austen WG, Edwards JE, Frye RL et al (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51:5–40PubMed
17.
go back to reference Leber AW, Becker A, Knez A et al (2006) Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47:672–677PubMedCrossRef Leber AW, Becker A, Knez A et al (2006) Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system: a comparative study using intravascular ultrasound. J Am Coll Cardiol 47:672–677PubMedCrossRef
18.
go back to reference Efron B, Tibshirani R (1993) An introduction to the bootstrap. Monographs on statistics and applied probability. Chapman & Hall, New York Efron B, Tibshirani R (1993) An introduction to the bootstrap. Monographs on statistics and applied probability. Chapman & Hall, New York
19.
go back to reference Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160PubMedCrossRef Bland JM, Altman DG (1999) Measuring agreement in method comparison studies. Stat Methods Med Res 8:135–160PubMedCrossRef
20.
go back to reference Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571–582PubMedCrossRef Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571–582PubMedCrossRef
21.
go back to reference Pinheiro J, Bates D (2000) Mixed-effects models in S and S-PLUS. Statistics and computing. Springer, New York Pinheiro J, Bates D (2000) Mixed-effects models in S and S-PLUS. Statistics and computing. Springer, New York
22.
go back to reference Burgstahler C, Reimann A, Beck T et al (2006) Imaging of a regressive coronary soft plaque under lipid lowering therapy by multi-slice computed tomography. Int J Cardiovasc Imaging 22:119–121PubMedCrossRef Burgstahler C, Reimann A, Beck T et al (2006) Imaging of a regressive coronary soft plaque under lipid lowering therapy by multi-slice computed tomography. Int J Cardiovasc Imaging 22:119–121PubMedCrossRef
23.
go back to reference Dewey M, Hoffmann H, Hamm B (2007) CT coronary angiography using 16 and 64 simultaneous detector rows: intraindividual comparison. Rofo 179:581–586PubMed Dewey M, Hoffmann H, Hamm B (2007) CT coronary angiography using 16 and 64 simultaneous detector rows: intraindividual comparison. Rofo 179:581–586PubMed
24.
go back to reference Virmani R, Kolodgie FD, Burke AP et al (2000) Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol 20:1262–1275PubMed Virmani R, Kolodgie FD, Burke AP et al (2000) Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol 20:1262–1275PubMed
25.
go back to reference Agatston AS, Janowitz WR, Hildner FJ et al (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832PubMedCrossRef Agatston AS, Janowitz WR, Hildner FJ et al (1990) Quantification of coronary artery calcium using ultrafast computed tomography. J Am Coll Cardiol 15:827–832PubMedCrossRef
26.
go back to reference Thomas CK, Muhlenbruch G, Wildberger JE et al (2006) Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol. Invest Radiol 41:668–673PubMedCrossRef Thomas CK, Muhlenbruch G, Wildberger JE et al (2006) Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol. Invest Radiol 41:668–673PubMedCrossRef
27.
go back to reference Pflederer T, Schmid M, Ropers D et al (2007) Interobserver variability of 64-slice computed tomography for the quantification of non-calcified coronary atherosclerotic plaque. Rofo Pflederer T, Schmid M, Ropers D et al (2007) Interobserver variability of 64-slice computed tomography for the quantification of non-calcified coronary atherosclerotic plaque. Rofo
28.
go back to reference Bruining N, Roelandt JR, Palumbo A et al (2007) Reproducible coronary plaque quantification by multislice computed tomography. Catheter Cardiovasc Interv 69:857–865PubMedCrossRef Bruining N, Roelandt JR, Palumbo A et al (2007) Reproducible coronary plaque quantification by multislice computed tomography. Catheter Cardiovasc Interv 69:857–865PubMedCrossRef
29.
go back to reference Schuurbiers JC, von Birgelen C, Wentzel JJ et al (2000) On the IVUS plaque volume error in coronary arteries when neglecting curvature. Ultrasound Med Biol 26:1403–1411PubMedCrossRef Schuurbiers JC, von Birgelen C, Wentzel JJ et al (2000) On the IVUS plaque volume error in coronary arteries when neglecting curvature. Ultrasound Med Biol 26:1403–1411PubMedCrossRef
30.
go back to reference Ferencik M, Nieman K, Achenbach S (2006) Noncalcified and calcified coronary plaque detection by contrast-enhanced multi-detector computed tomography: a study of interobserver agreement. J Am Coll Cardiol 47:207–209PubMedCrossRef Ferencik M, Nieman K, Achenbach S (2006) Noncalcified and calcified coronary plaque detection by contrast-enhanced multi-detector computed tomography: a study of interobserver agreement. J Am Coll Cardiol 47:207–209PubMedCrossRef
Metadata
Title
Intra- and interobserver variability in detection and assessment of calcified and noncalcified coronary artery plaques using 64-slice computed tomography
Variability in coronary plaque measurement using MSCT
Authors
Hans Hoffmann
Katja Frieler
Bernd Hamm
Marc Dewey
Publication date
01-10-2008
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 7/2008
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-008-9299-z

Other articles of this Issue 7/2008

The International Journal of Cardiovascular Imaging 7/2008 Go to the issue