Skip to main content
Top
Published in: Breast Cancer Research and Treatment 2/2013

01-01-2013 | Epidemiology

One-day core needle biopsy in a breast clinic: 4 years experience

Authors: Joris P. Bulte, Lenny Polman, Margrethe Schlooz-Vries, Annelies Werner, Renate Besselink, Kelly Sessink, Roel Mus, Susanne Lardenoije, Mechli Imhof-Tas, Johan Bulten, Adriana C. H. van Engen-van Grunsven, Ewout Schaafsma, Luc J. A. Strobbe, Peter Bult, Johannes H. W. De Wilt

Published in: Breast Cancer Research and Treatment | Issue 2/2013

Login to get access

Abstract

Many attempts have been made to combine the high diagnostic accuracy and conclusive rate of core needle biopsy (CNB) with the speed of fine needle aspiration cytology in evaluation of solid breast lesions. Multiple hybrid techniques have been developed to achieve this. We describe a cohort of patients for whom we used a relatively new, accelerated method of CNB processing, allowing for a definitive diagnosis the same day. All patients visiting the Radboud University Nijmegen Medical Centre breast clinic during a 4-year period were reviewed to identify all CNBs in this period performed in a same-day diagnosis track. CNB result was compared to post-operative pathology reports when available, and to follow-up when patients were not surgically treated. 1,060 patients underwent CNB of 1,383 lesions, 898 of which in a same-day diagnosis track with a sensitivity of 96.9 % and a specificity of 99.4 %. The inconclusive rate was 9.2 %. For a same-day diagnosis for solid breast lesions, we could give a conclusive diagnosis with accelerated CNB processing in 65 % of our patients requiring CNB. This technique can be used reliably in a same-day diagnosis breast clinic with a very high sensitivity, specificity, and conclusive rate.
Literature
1.
go back to reference Parker SH, Jobe WE, Dennis MA, Stavros AT, Johnson KK, Yakes WF, Truell JE, Price JG, Kortz AB, Clark DG (1993) US-guided automated large-core breast biopsy. Radiology 187(2):507–511PubMed Parker SH, Jobe WE, Dennis MA, Stavros AT, Johnson KK, Yakes WF, Truell JE, Price JG, Kortz AB, Clark DG (1993) US-guided automated large-core breast biopsy. Radiology 187(2):507–511PubMed
2.
go back to reference Westenend PJ, Sever AR, Beekman-De Volder HJ, Liem SJ (2001) A comparison of aspiration cytology and core needle biopsy in the evaluation of breast lesions. Cancer 93(2):146–150PubMedCrossRef Westenend PJ, Sever AR, Beekman-De Volder HJ, Liem SJ (2001) A comparison of aspiration cytology and core needle biopsy in the evaluation of breast lesions. Cancer 93(2):146–150PubMedCrossRef
3.
go back to reference Brancato B, Crocetti E, Bianchi S, Catarzi S, Risso GG, Bulgaresi P, Piscioli F, Scialpi M, Ciatto S, Houssami N (2012) Accuracy of needle biopsy of breast lesions visible on ultrasound: audit of fine needle versus core needle biopsy in 3233 consecutive samplings with ascertained outcomes. Breast (Edinburgh, Scotland) 21(4):449–454. doi:10.1016/j.breast.2011.10.008 CrossRef Brancato B, Crocetti E, Bianchi S, Catarzi S, Risso GG, Bulgaresi P, Piscioli F, Scialpi M, Ciatto S, Houssami N (2012) Accuracy of needle biopsy of breast lesions visible on ultrasound: audit of fine needle versus core needle biopsy in 3233 consecutive samplings with ascertained outcomes. Breast (Edinburgh, Scotland) 21(4):449–454. doi:10.​1016/​j.​breast.​2011.​10.​008 CrossRef
4.
go back to reference Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S (2005) Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound 33(2):47–52. doi:10.1002/jcu.20089 PubMedCrossRef Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S (2005) Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound 33(2):47–52. doi:10.​1002/​jcu.​20089 PubMedCrossRef
7.
go back to reference Barra Ade A, Gobbi H, de L Rezende CA, Gouvea AP, de Lucena CE, Gouvea AP, Reis JH, Costa e Silva SZ (2008) A comparison of aspiration cytology and core needle biopsy according to tumor size of suspicious breast lesions. Diagn Cytopathol 36(1):26–31. doi:10.1002/dc.20748 PubMedCrossRef Barra Ade A, Gobbi H, de L Rezende CA, Gouvea AP, de Lucena CE, Gouvea AP, Reis JH, Costa e Silva SZ (2008) A comparison of aspiration cytology and core needle biopsy according to tumor size of suspicious breast lesions. Diagn Cytopathol 36(1):26–31. doi:10.​1002/​dc.​20748 PubMedCrossRef
9.
go back to reference Dey P, Bundred N, Gibbs A, Hopwood P, Baildam A, Boggis C, James M, Knox F, Leidecker V, Woodman C (2002) Costs and benefits of a one stop clinic compared with a dedicated breast clinic: randomised controlled trial. BMJ 324(7336):507PubMedCrossRef Dey P, Bundred N, Gibbs A, Hopwood P, Baildam A, Boggis C, James M, Knox F, Leidecker V, Woodman C (2002) Costs and benefits of a one stop clinic compared with a dedicated breast clinic: randomised controlled trial. BMJ 324(7336):507PubMedCrossRef
10.
go back to reference Dixon JM, Lamb J, Stones G, Rahman A, Mitchell D (1998) Satisfaction with nurse specialists in breast care clinics. Nurse led clinics may actually cost more. BMJ 317(7168):1316 author reply 1316–1317PubMedCrossRef Dixon JM, Lamb J, Stones G, Rahman A, Mitchell D (1998) Satisfaction with nurse specialists in breast care clinics. Nurse led clinics may actually cost more. BMJ 317(7168):1316 author reply 1316–1317PubMedCrossRef
11.
go back to reference Henselmans I, Sanderman R, Smink A, Ranchor AV, de Vries J (2010) Waiting times in breast disease clinics and psychological well-being: speedy care is better care. Ned Tijdschr Geneeskd 154:B491PubMed Henselmans I, Sanderman R, Smink A, Ranchor AV, de Vries J (2010) Waiting times in breast disease clinics and psychological well-being: speedy care is better care. Ned Tijdschr Geneeskd 154:B491PubMed
13.
go back to reference Green RS, Mathew S (2001) The contribution of cytologic imprints of stereotactically guided core needle biopsies of the breast in the management of patients with mammographic abnormalities. Breast J 7(4):214–218. doi:99070 PubMedCrossRef Green RS, Mathew S (2001) The contribution of cytologic imprints of stereotactically guided core needle biopsies of the breast in the management of patients with mammographic abnormalities. Breast J 7(4):214–218. doi:99070 PubMedCrossRef
14.
go back to reference Bauermeister DE (1980) The role and limitations of frozen section and needle aspiration biopsy in breast cancer diagnosis. Cancer 46(4 Suppl):947–949PubMedCrossRef Bauermeister DE (1980) The role and limitations of frozen section and needle aspiration biopsy in breast cancer diagnosis. Cancer 46(4 Suppl):947–949PubMedCrossRef
17.
19.
go back to reference Kass R, Henry-Tillman RS, Nurko J, Korourian S, Mancino AT, Colvert M, Johnson A, Lane S, Layeeque R, Brown H, Fincher R, De Las Casas L, Waldron J, Klimberg VS (2003) Touch preparation of breast core needle specimens is a new method for same-day diagnosis. Am J Surg 186(6):737–741 discussion 742PubMedCrossRef Kass R, Henry-Tillman RS, Nurko J, Korourian S, Mancino AT, Colvert M, Johnson A, Lane S, Layeeque R, Brown H, Fincher R, De Las Casas L, Waldron J, Klimberg VS (2003) Touch preparation of breast core needle specimens is a new method for same-day diagnosis. Am J Surg 186(6):737–741 discussion 742PubMedCrossRef
21.
go back to reference Wauters CA, Sanders-Eras MC, de Kievit-van der Heijden IM, Wesseling P, Venderink DJ, van Dijk Azn R, van den Wildenberg F, Kooistra BW, Strobbe LJ (2010) Modified core wash cytology (CWC), an asset in the diagnostic work-up of breast lesions. Eur J Surg Oncol 36 (10):957–962. doi:10.1016/j.ejso.2010.07.006 Wauters CA, Sanders-Eras MC, de Kievit-van der Heijden IM, Wesseling P, Venderink DJ, van Dijk Azn R, van den Wildenberg F, Kooistra BW, Strobbe LJ (2010) Modified core wash cytology (CWC), an asset in the diagnostic work-up of breast lesions. Eur J Surg Oncol 36 (10):957–962. doi:10.​1016/​j.​ejso.​2010.​07.​006
22.
go back to reference Mueller-Holzner E, Frede T, Daniaux M, Ban M, Taucher S, Schneitter A, Zeimet AG, Marth C (2007) Ultrasound-guided core needle biopsy of the breast: does frozen section give an accurate diagnosis? Breast Cancer Res Treat 106(3):399–406. doi:10.1007/s10549-007-9508-9 PubMedCrossRef Mueller-Holzner E, Frede T, Daniaux M, Ban M, Taucher S, Schneitter A, Zeimet AG, Marth C (2007) Ultrasound-guided core needle biopsy of the breast: does frozen section give an accurate diagnosis? Breast Cancer Res Treat 106(3):399–406. doi:10.​1007/​s10549-007-9508-9 PubMedCrossRef
25.
go back to reference Casparie M, Tiebosch AT, Burger G, Blauwgeers H, van de Pol A, van Krieken JH, Meijer GA (2007) Pathology databanking and biobanking in The Netherlands, a central role for PALGA, the nationwide histopathology and cytopathology data network and archive. Cell oncol 29(1):19–24PubMed Casparie M, Tiebosch AT, Burger G, Blauwgeers H, van de Pol A, van Krieken JH, Meijer GA (2007) Pathology databanking and biobanking in The Netherlands, a central role for PALGA, the nationwide histopathology and cytopathology data network and archive. Cell oncol 29(1):19–24PubMed
26.
go back to reference Rakha EA, El-Sayed ME, Reed J, Lee AH, Evans AJ, Ellis IO (2009) Screen-detected breast lesions with malignant needle core biopsy diagnoses and no malignancy identified in subsequent surgical excision specimens (potential false-positive diagnosis). Eur J Cancer 45(7):1162–1167. doi:10.1016/j.ejca.2008.12.002 PubMedCrossRef Rakha EA, El-Sayed ME, Reed J, Lee AH, Evans AJ, Ellis IO (2009) Screen-detected breast lesions with malignant needle core biopsy diagnoses and no malignancy identified in subsequent surgical excision specimens (potential false-positive diagnosis). Eur J Cancer 45(7):1162–1167. doi:10.​1016/​j.​ejca.​2008.​12.​002 PubMedCrossRef
27.
go back to reference Fahrbach K, Sledge I, Cella C, Linz H, Ross SD (2006) A comparison of the accuracy of two minimally invasive breast biopsy methods: a systematic literature review and meta-analysis. Arch Gynecol Obstet 274(2):63–73. doi:10.1007/s00404-005-0106-y PubMedCrossRef Fahrbach K, Sledge I, Cella C, Linz H, Ross SD (2006) A comparison of the accuracy of two minimally invasive breast biopsy methods: a systematic literature review and meta-analysis. Arch Gynecol Obstet 274(2):63–73. doi:10.​1007/​s00404-005-0106-y PubMedCrossRef
28.
go back to reference Meijnen P, Oldenburg HS, Loo CE, Nieweg OE, Peterse JL, Rutgers EJ (2007) Risk of invasion and axillary lymph node metastasis in ductal carcinoma in situ diagnosed by core-needle biopsy. Br J Surg 94(8):952–956. doi:10.1002/bjs.5735 PubMedCrossRef Meijnen P, Oldenburg HS, Loo CE, Nieweg OE, Peterse JL, Rutgers EJ (2007) Risk of invasion and axillary lymph node metastasis in ductal carcinoma in situ diagnosed by core-needle biopsy. Br J Surg 94(8):952–956. doi:10.​1002/​bjs.​5735 PubMedCrossRef
29.
go back to reference Fajardo LL, Pisano ED, Caudry DJ, Gatsonis CA, Berg WA, Connolly J, Schnitt S, Page DL, McNeil BJ (2004) Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study. Acad Radiol 11(3):293–308PubMedCrossRef Fajardo LL, Pisano ED, Caudry DJ, Gatsonis CA, Berg WA, Connolly J, Schnitt S, Page DL, McNeil BJ (2004) Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study. Acad Radiol 11(3):293–308PubMedCrossRef
30.
31.
go back to reference Kline TS, Joshi LP, Neal HS (1979) Fine-needle aspiration of the breast: diagnoses and pitfalls. A review of 3545 cases. Cancer 44(4):1458–1464PubMedCrossRef Kline TS, Joshi LP, Neal HS (1979) Fine-needle aspiration of the breast: diagnoses and pitfalls. A review of 3545 cases. Cancer 44(4):1458–1464PubMedCrossRef
32.
go back to reference Cohen MB, Rodgers RP, Hales MS, Gonzales JM, Ljung BM, Beckstead JH, Bottles K, Miller TR (1987) Influence of training and experience in fine-needle aspiration biopsy of breast. Receiver operating characteristics curve analysis. Arch Pathol Lab Med 111(6):518–520PubMed Cohen MB, Rodgers RP, Hales MS, Gonzales JM, Ljung BM, Beckstead JH, Bottles K, Miller TR (1987) Influence of training and experience in fine-needle aspiration biopsy of breast. Receiver operating characteristics curve analysis. Arch Pathol Lab Med 111(6):518–520PubMed
33.
go back to reference Collins LC, Connolly JL, Page DL, Goulart RA, Pisano ED, Fajardo LL, Berg WA, Caudry DJ, McNeil BJ, Schnitt SJ (2004) Diagnostic agreement in the evaluation of image-guided breast core needle biopsies: results from a randomized clinical trial. Am J Surg Pathol 28(1):126–131PubMedCrossRef Collins LC, Connolly JL, Page DL, Goulart RA, Pisano ED, Fajardo LL, Berg WA, Caudry DJ, McNeil BJ, Schnitt SJ (2004) Diagnostic agreement in the evaluation of image-guided breast core needle biopsies: results from a randomized clinical trial. Am J Surg Pathol 28(1):126–131PubMedCrossRef
34.
go back to reference Verkooijen HM, Peterse JL, Schipper ME, Buskens E, Hendriks JH, Pijnappel RM, Peeters PH, Borel Rinkes IH, Mali WP, Holland R (2003) Interobserver variability between general and expert pathologists during the histopathological assessment of large-core needle and open biopsies of non-palpable breast lesions. Eur J Cancer 39(15):2187–2191PubMedCrossRef Verkooijen HM, Peterse JL, Schipper ME, Buskens E, Hendriks JH, Pijnappel RM, Peeters PH, Borel Rinkes IH, Mali WP, Holland R (2003) Interobserver variability between general and expert pathologists during the histopathological assessment of large-core needle and open biopsies of non-palpable breast lesions. Eur J Cancer 39(15):2187–2191PubMedCrossRef
35.
go back to reference Hukkinen K, Kivisaari L, Heikkila PS, Von Smitten K, Leidenius M (2008) Unsuccessful preoperative biopsies, fine needle aspiration cytology or core needle biopsy, lead to increased costs in the diagnostic workup in breast cancer. Acta Oncol 47(6):1037–1045. doi:10.1080/02841860802001442 PubMedCrossRef Hukkinen K, Kivisaari L, Heikkila PS, Von Smitten K, Leidenius M (2008) Unsuccessful preoperative biopsies, fine needle aspiration cytology or core needle biopsy, lead to increased costs in the diagnostic workup in breast cancer. Acta Oncol 47(6):1037–1045. doi:10.​1080/​0284186080200144​2 PubMedCrossRef
Metadata
Title
One-day core needle biopsy in a breast clinic: 4 years experience
Authors
Joris P. Bulte
Lenny Polman
Margrethe Schlooz-Vries
Annelies Werner
Renate Besselink
Kelly Sessink
Roel Mus
Susanne Lardenoije
Mechli Imhof-Tas
Johan Bulten
Adriana C. H. van Engen-van Grunsven
Ewout Schaafsma
Luc J. A. Strobbe
Peter Bult
Johannes H. W. De Wilt
Publication date
01-01-2013
Publisher
Springer US
Published in
Breast Cancer Research and Treatment / Issue 2/2013
Print ISSN: 0167-6806
Electronic ISSN: 1573-7217
DOI
https://doi.org/10.1007/s10549-012-2372-2

Other articles of this Issue 2/2013

Breast Cancer Research and Treatment 2/2013 Go to the issue
Webinar | 19-02-2024 | 17:30 (CET)

Keynote webinar | Spotlight on antibody–drug conjugates in cancer

Antibody–drug conjugates (ADCs) are novel agents that have shown promise across multiple tumor types. Explore the current landscape of ADCs in breast and lung cancer with our experts, and gain insights into the mechanism of action, key clinical trials data, existing challenges, and future directions.

Dr. Véronique Diéras
Prof. Fabrice Barlesi
Developed by: Springer Medicine