Skip to main content
Top
Published in: Gynecological Surgery 1/2007

01-03-2007 | Review Article

Use of the BiClamp (a bipolar coagulation forceps) in gynecological surgery

Authors: W. Zubke, B. Krämer, R. Hornung, D. Wallwiener

Published in: Gynecological Surgery | Issue 1/2007

Login to get access

Abstract

The integration of new technical possibilities into the overall concept is the determining factor in progress in surgery. The availability of the BiClamp and its specially designed electrical concept mean that we now have a new bipolar coagulation forceps at our disposal. Based on the principles of electrosurgery, we developed a new current modulation that has improved hemostatic properties. The new current modulation can be used for bipolar laparoscopic coagulation forceps, and also for new types of forceps for open surgery. The main area of use in open surgery is vaginal hysterectomy. Initial retrospective studies all showed that the newly designed forceps are a successful surgical instrument. The use of the BiClamp for vaginal hysterectomy leads to less blood loss and less postoperative pain, with similar results in these respects to laparoscopic surgery. In some studies, the duration of surgery was shorter than with conventional vaginal hysterectomy, and in others of similar length. Prospective, randomized controlled studies have, however, yet to be performed. We are of the opinion that confirmation of the results achieved so far will increase the spectrum of indications for this bipolar coagulation forceps, leading to greater patient benefit.
Literature
1.
go back to reference Reich H, De Caprio J, McGlynn F (1989) Laparoscopic hysterectomy. J Gynecol Surg 5:213–216CrossRef Reich H, De Caprio J, McGlynn F (1989) Laparoscopic hysterectomy. J Gynecol Surg 5:213–216CrossRef
2.
go back to reference Mayer A (1950) 50 Jahre selbst erlebte Gynäkologie (50 years’ experience of gynecology: a personal account). J.F. Lehmann Verlag, Munich Mayer A (1950) 50 Jahre selbst erlebte Gynäkologie (50 years’ experience of gynecology: a personal account). J.F. Lehmann Verlag, Munich
3.
go back to reference Wallwiener C, Wallwiener M, Neuenhoeffer E, Menger M, Isaacson K, Zubke W (2007) Intelligent, impedance-regulated, pulsed coagulation in a porcine renal artery model. Fertil Steril (in press) Wallwiener C, Wallwiener M, Neuenhoeffer E, Menger M, Isaacson K, Zubke W (2007) Intelligent, impedance-regulated, pulsed coagulation in a porcine renal artery model. Fertil Steril (in press)
4.
go back to reference Clavé H, Niccolai P (2003) Hysterectomie sans douleurs: une technique innovante (Painless hysterectomy: an innovative technique). J Gyneco Obstet Biol Reprod 32:375–380 Clavé H, Niccolai P (2003) Hysterectomie sans douleurs: une technique innovante (Painless hysterectomy: an innovative technique). J Gyneco Obstet Biol Reprod 32:375–380
5.
go back to reference Clavé H, Baar H, Niccolai P (2005) Painless vaginal hysterectomy with thermal hemostasis (result of a series of 152 cases). J Gynecol Surg 2:101–105CrossRef Clavé H, Baar H, Niccolai P (2005) Painless vaginal hysterectomy with thermal hemostasis (result of a series of 152 cases). J Gynecol Surg 2:101–105CrossRef
6.
go back to reference Zubke W, Becker S, Krämer B, Wallwiener D (2004) Vaginal hysterectomy: a new approach using bicoagulation forceps. J Gynecol Surg 1:179–182 Zubke W, Becker S, Krämer B, Wallwiener D (2004) Vaginal hysterectomy: a new approach using bicoagulation forceps. J Gynecol Surg 1:179–182
7.
go back to reference Zubke W, Fehm T, Wallwiener D (2005) BiClamp for vaginal and laparoscopic hysterectomies. In: Malinowskiego A (ed) Zaawansowane techniki laparoskopowe w ginekologii. Drukarina LCL, Lodz: pp 27–36 Zubke W, Fehm T, Wallwiener D (2005) BiClamp for vaginal and laparoscopic hysterectomies. In: Malinowskiego A (ed) Zaawansowane techniki laparoskopowe w ginekologii. Drukarina LCL, Lodz: pp 27–36
8.
go back to reference Lobodasch K, Zubke W (2005) Vaginale Hysterektomien mit Hilfe der Biclamp. Gerburtsh Frauenheilk 65:1191–1193CrossRef Lobodasch K, Zubke W (2005) Vaginale Hysterektomien mit Hilfe der Biclamp. Gerburtsh Frauenheilk 65:1191–1193CrossRef
9.
go back to reference Wojdat R, Volz J (2004) Vaginale Hysterektomie mit Hilfe der BiClamp®-ein Erfahrungsbericht (Practical experience with the BiClamp® in vaginal hysterectomy. 55th Kongress Dt. Ges. Geb. Gyn. Hamburg Wojdat R, Volz J (2004) Vaginale Hysterektomie mit Hilfe der BiClamp®-ein Erfahrungsbericht (Practical experience with the BiClamp® in vaginal hysterectomy. 55th Kongress Dt. Ges. Geb. Gyn. Hamburg
10.
go back to reference Sagae S (2006) Vaginal hysterectomies with the BiClamp. New Techniques in Vaginal Hysterectomy Congress. Tokyo Sagae S (2006) Vaginal hysterectomies with the BiClamp. New Techniques in Vaginal Hysterectomy Congress. Tokyo
Metadata
Title
Use of the BiClamp (a bipolar coagulation forceps) in gynecological surgery
Authors
W. Zubke
B. Krämer
R. Hornung
D. Wallwiener
Publication date
01-03-2007
Publisher
Springer-Verlag
Published in
Gynecological Surgery / Issue 1/2007
Print ISSN: 1613-2076
Electronic ISSN: 1613-2084
DOI
https://doi.org/10.1007/s10397-006-0262-5

Other articles of this Issue 1/2007

Gynecological Surgery 1/2007 Go to the issue

Acknowledgement to reviewers

Acknowledgement to reviewers