Abstract

Magnetic resonance imaging (MRI) is the examination method of choice for the diagnosis of a variety of diseases. MRI allows us to obtain not only anatomical information but also identification of physiological and functional parameters such as networks in the brain and tumor cellularity, which plays an increasing role in oncologic imaging, as well as blood flow and tissue perfusion. However, in many cases such as in epilepsy, degenerative neurological diseases and oncological processes, additional metabolic and molecular information obtained by PET can provide essential complementary information for better diagnosis. The combined information obtained from MRI and PET acquired in a single imaging session allows a more accurate localization of pathological findings and better assessment of the underlying physiopathology, thus providing a more powerful diagnostic tool. Two hundred and twenty-one patients were scanned from April 2011 to January 2012 on a Philips Ingenuity TF PET/MRI system. The purpose of this review article is to provide an overview of the techniques used for the optimization of different protocols performed in our hospital by specialists in the following fields: neuroradiology, head and neck, breast, and prostate imaging. This paper also discusses the different problems encountered, such as the length of studies, motion artifacts, and accuracy of image fusion including physical and technical aspects, and the proposed solutions.
Literature
1.
go back to reference Shao Y, Cherry SR, Farahani K, Meadors K, Siegel S, Silverman RW, Marsden PK (1997) Simultaneous PET and MR imaging. Phys Med Biol 42(10):1965–1970PubMedCrossRef Shao Y, Cherry SR, Farahani K, Meadors K, Siegel S, Silverman RW, Marsden PK (1997) Simultaneous PET and MR imaging. Phys Med Biol 42(10):1965–1970PubMedCrossRef
2.
go back to reference Woods RP, Mazziotta JC, Cherry SR (1993) MRI-PET registration with automated algorithm. J Comput Assist Tomogr 17(4):536–546PubMedCrossRef Woods RP, Mazziotta JC, Cherry SR (1993) MRI-PET registration with automated algorithm. J Comput Assist Tomogr 17(4):536–546PubMedCrossRef
3.
go back to reference Ratib O, Beyer T (2011) Whole-body hybrid PET/MRI: ready for clinical use? Eur J Nucl Med Mol Imaging 38(6):992–995PubMedCrossRef Ratib O, Beyer T (2011) Whole-body hybrid PET/MRI: ready for clinical use? Eur J Nucl Med Mol Imaging 38(6):992–995PubMedCrossRef
4.
go back to reference Schlemmer HP, Pichler BJ, Schmand M, Burbar Z, Michel C, Ladebeck R, Jattke K, Townsend D, Nahmias C, Jacob PK, Heiss WD, Claussen CD (2008) Simultaneous MR/PET imaging of the human brain: feasibility study. Radiology 248(3):1028–1035PubMedCrossRef Schlemmer HP, Pichler BJ, Schmand M, Burbar Z, Michel C, Ladebeck R, Jattke K, Townsend D, Nahmias C, Jacob PK, Heiss WD, Claussen CD (2008) Simultaneous MR/PET imaging of the human brain: feasibility study. Radiology 248(3):1028–1035PubMedCrossRef
5.
go back to reference Catana C, Wu Y, Judenhofer MS, Qi J, Pichler BJ, Cherry SR (2006) Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med 47(12):1968–1976PubMed Catana C, Wu Y, Judenhofer MS, Qi J, Pichler BJ, Cherry SR (2006) Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner. J Nucl Med 47(12):1968–1976PubMed
6.
go back to reference Zaidi H, Ojha N, Morich M, Griesmer J, Hu Z, Maniawski P, Ratib O, Izquierdo-Garcia D, Fayad ZA, Shao L (2011) Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol 56(10):3091–3106PubMedCrossRef Zaidi H, Ojha N, Morich M, Griesmer J, Hu Z, Maniawski P, Ratib O, Izquierdo-Garcia D, Fayad ZA, Shao L (2011) Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system. Phys Med Biol 56(10):3091–3106PubMedCrossRef
7.
go back to reference Pendse N, Wissmeyer M, Altrichter S, Vargas M, Delavelle J, Viallon M, Federspiel A, Seeck M, Schaller K, Lövblad KO (2010) Interictal arterial spin-labeling MRI perfusion in intractable epilepsy. J Neuroradiol 37(1):60–63PubMedCrossRef Pendse N, Wissmeyer M, Altrichter S, Vargas M, Delavelle J, Viallon M, Federspiel A, Seeck M, Schaller K, Lövblad KO (2010) Interictal arterial spin-labeling MRI perfusion in intractable epilepsy. J Neuroradiol 37(1):60–63PubMedCrossRef
8.
go back to reference Boss A, Stegger L, Bisdas S, Kolb A, Schwenzer N, Pfister M, Claussen CD, Pichler BJ, Pfannenberg C (2011) Feasibility of simultaneous PET/MR imaging in the head and upper neck area. Eur Radiol 21(7):1439–1446PubMedCrossRef Boss A, Stegger L, Bisdas S, Kolb A, Schwenzer N, Pfister M, Claussen CD, Pichler BJ, Pfannenberg C (2011) Feasibility of simultaneous PET/MR imaging in the head and upper neck area. Eur Radiol 21(7):1439–1446PubMedCrossRef
9.
go back to reference Garibotto V, Vargas MI, Lovblad KO, Ratib O (2011) A PET-MRI case of corticocerebellar diaschisis after stroke. Clin Nucl Med 36(9):821–825PubMedCrossRef Garibotto V, Vargas MI, Lovblad KO, Ratib O (2011) A PET-MRI case of corticocerebellar diaschisis after stroke. Clin Nucl Med 36(9):821–825PubMedCrossRef
10.
go back to reference Garibotto V, Heinzer S, Vulliemoz S, Guignard R, Wissmeyer M, Seeck M, Lovblad KO, Zaidi H, Ratib O, Vargas MI (2012) Clinical applications of hybrid PET/MRI in neuroimaging. Clin Nucl Med. doi:10.1097/RLU.0b013e3182638ea6 Garibotto V, Heinzer S, Vulliemoz S, Guignard R, Wissmeyer M, Seeck M, Lovblad KO, Zaidi H, Ratib O, Vargas MI (2012) Clinical applications of hybrid PET/MRI in neuroimaging. Clin Nucl Med. doi:10.​1097/​RLU.​0b013e3182638ea6​
11.
go back to reference Vander Borght T, Asenbaum S, Bartenstein P, Halldin C, Kapucu O, Van Laere K, Varrone A, Tatsch K (2006) EANM procedure guidelines for brain tumour imaging using labelled amino acid analogues. Eur J Nucl Med Mol Imaging 33(11):1374–1380PubMedCrossRef Vander Borght T, Asenbaum S, Bartenstein P, Halldin C, Kapucu O, Van Laere K, Varrone A, Tatsch K (2006) EANM procedure guidelines for brain tumour imaging using labelled amino acid analogues. Eur J Nucl Med Mol Imaging 33(11):1374–1380PubMedCrossRef
12.
go back to reference Varrone A, Asenbaum S, Vander Borght T, Booij J, Nobili F, Nagren K, Darcourt J, Kapucu OL, Tatsch K, Bartenstein P, Van Laere K (2009) EANM procedure guidelines for PET brain imaging using [18F] FDG, version 2. Eur J Nucl Med Mol Imaging 36(12):2103–2110PubMedCrossRef Varrone A, Asenbaum S, Vander Borght T, Booij J, Nobili F, Nagren K, Darcourt J, Kapucu OL, Tatsch K, Bartenstein P, Van Laere K (2009) EANM procedure guidelines for PET brain imaging using [18F] FDG, version 2. Eur J Nucl Med Mol Imaging 36(12):2103–2110PubMedCrossRef
13.
go back to reference Steiner C, Vees H, Zaidi H, Wissmeyer M, Berrebi O, Kossovsky MP, Khan HG, Miralbell R, Ratib O, Buchegger F (2009) Three-phase 18F-fluorocholine PET/CT in the evaluation of prostate cancer recurrence. Nuklearmedizin 48(1):1–9PubMed Steiner C, Vees H, Zaidi H, Wissmeyer M, Berrebi O, Kossovsky MP, Khan HG, Miralbell R, Ratib O, Buchegger F (2009) Three-phase 18F-fluorocholine PET/CT in the evaluation of prostate cancer recurrence. Nuklearmedizin 48(1):1–9PubMed
14.
go back to reference Boellaard R, O’Doherty MJ, Weber WA, Mottaghy FM, Lonsdale MN, Stroobants SG, Oyen WJ, Kotzerke J, Hoekstra OS, Pruim J, Marsden PK, Tatsch K, Hoekstra CJ, Visser EP, Arends B, Verzijlbergen FJ, Zijlstra JM, Comans EF, Lammertsma AA, Paans AM, Willemsen AT, Beyer T, Bockisch A, Schaefer-Prokop C, Delbeke D, Baum RP, Chiti A, Krause BJ (2010) FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37(1):181–200PubMedCrossRef Boellaard R, O’Doherty MJ, Weber WA, Mottaghy FM, Lonsdale MN, Stroobants SG, Oyen WJ, Kotzerke J, Hoekstra OS, Pruim J, Marsden PK, Tatsch K, Hoekstra CJ, Visser EP, Arends B, Verzijlbergen FJ, Zijlstra JM, Comans EF, Lammertsma AA, Paans AM, Willemsen AT, Beyer T, Bockisch A, Schaefer-Prokop C, Delbeke D, Baum RP, Chiti A, Krause BJ (2010) FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0. Eur J Nucl Med Mol Imaging 37(1):181–200PubMedCrossRef
15.
go back to reference Browne JA, De Pierro AR (1996) A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography. IEEE Trans Med Imaging 15(5):687–699PubMedCrossRef Browne JA, De Pierro AR (1996) A row-action alternative to the EM algorithm for maximizing likelihoods in emission tomography. IEEE Trans Med Imaging 15(5):687–699PubMedCrossRef
16.
go back to reference Hudson M, Larkin RS (1994) Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 13:601–609PubMedCrossRef Hudson M, Larkin RS (1994) Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imaging 13:601–609PubMedCrossRef
17.
go back to reference Catana C, van der Kouwe A, Benner T, Michel CJ, Hamm M, Fenchel M, Fischl B, Rosen B, Schmand M, Sorensen AG (2010) Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med 51(9):1431–1438PubMedCrossRef Catana C, van der Kouwe A, Benner T, Michel CJ, Hamm M, Fenchel M, Fischl B, Rosen B, Schmand M, Sorensen AG (2010) Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype. J Nucl Med 51(9):1431–1438PubMedCrossRef
18.
go back to reference Catana C, Benner T, van der Kouwe A, Byars L, Hamm M, Chonde DB, Michel CJ, El Fakhri G, Schmand M, Sorensen AG (2011) MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner. J Nucl Med 52(1):154–161PubMedCrossRef Catana C, Benner T, van der Kouwe A, Byars L, Hamm M, Chonde DB, Michel CJ, El Fakhri G, Schmand M, Sorensen AG (2011) MRI-assisted PET motion correction for neurologic studies in an integrated MR-PET scanner. J Nucl Med 52(1):154–161PubMedCrossRef
19.
go back to reference Hoffman EJ, Guerrero TM, Germano G, Digby WM, Dahlbom M (1989) PET system calibrations and corrections for quantitative and spatially accurate images. IEEE Trans Nucl Sci 36(1):1108–1112CrossRef Hoffman EJ, Guerrero TM, Germano G, Digby WM, Dahlbom M (1989) PET system calibrations and corrections for quantitative and spatially accurate images. IEEE Trans Nucl Sci 36(1):1108–1112CrossRef
20.
go back to reference Ng TS, Procissi D, Wu Y, Jacobs RE (2010) A robust coregistration method for in vivo studies using a first generation simultaneous PET/MR scanner. Med Phys 37(5):1995–2003PubMedCrossRef Ng TS, Procissi D, Wu Y, Jacobs RE (2010) A robust coregistration method for in vivo studies using a first generation simultaneous PET/MR scanner. Med Phys 37(5):1995–2003PubMedCrossRef
21.
go back to reference Langlois S, Desvignes M, Constans JM, Revenu M (1999) MRI geometric distortion: a simple approach to correcting the effects of non-linear gradient fields. J Magn Reson Imaging 9(6):821–831PubMedCrossRef Langlois S, Desvignes M, Constans JM, Revenu M (1999) MRI geometric distortion: a simple approach to correcting the effects of non-linear gradient fields. J Magn Reson Imaging 9(6):821–831PubMedCrossRef
22.
go back to reference Eggers H, Brendel B, Duijndam A, Herigault G (2001) Dual-echo Dixon imaging with flexible choice of echo times. Magn Reson Med 65(1):96–107CrossRef Eggers H, Brendel B, Duijndam A, Herigault G (2001) Dual-echo Dixon imaging with flexible choice of echo times. Magn Reson Med 65(1):96–107CrossRef
23.
go back to reference Vargas MI, Delavelle J, Kohler R, Becker CD, Lovblad K (2009) Brain and spine MRI artifacts at 3Tesla. J Neuroradiol 36(2):74–81PubMedCrossRef Vargas MI, Delavelle J, Kohler R, Becker CD, Lovblad K (2009) Brain and spine MRI artifacts at 3Tesla. J Neuroradiol 36(2):74–81PubMedCrossRef
24.
go back to reference Delso G, Fürst S, Jakoby B, Ladebeck R, Ganter C, Nekolla SG, Schwaiger M, Ziegler SI (2001) Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med 52(12):1914–1922CrossRef Delso G, Fürst S, Jakoby B, Ladebeck R, Ganter C, Nekolla SG, Schwaiger M, Ziegler SI (2001) Performance measurements of the Siemens mMR integrated whole-body PET/MR scanner. J Nucl Med 52(12):1914–1922CrossRef
25.
go back to reference Becker M, Zbaren P, Casselman JW, Kohler R, Dulguerov P, Becker CD (2008) Neoplastic invasion of laryngeal cartilage: reassessment of criteria for diagnosis at MR imaging. Radiology 249(2):551–559PubMedCrossRef Becker M, Zbaren P, Casselman JW, Kohler R, Dulguerov P, Becker CD (2008) Neoplastic invasion of laryngeal cartilage: reassessment of criteria for diagnosis at MR imaging. Radiology 249(2):551–559PubMedCrossRef
Metadata
Title
Approaches for the optimization of MR protocols in clinical hybrid PET/MRI studies
Authors
Maria-Isabel Vargas
Minerva Becker
Valentina Garibotto
Susanne Heinzer
Pierre Loubeyre
Joanna Gariani
Karl Lovblad
Jean-Paul Vallée
Osman Ratib
Publication date
01-02-2013
Publisher
Springer-Verlag
Published in
Magnetic Resonance Materials in Physics, Biology and Medicine / Issue 1/2013
Print ISSN: 0968-5243
Electronic ISSN: 1352-8661
DOI
https://doi.org/10.1007/s10334-012-0340-9

Other articles of this Issue 1/2013

Magnetic Resonance Materials in Physics, Biology and Medicine 1/2013 Go to the issue