Skip to main content
Top
Published in: Journal of Digital Imaging 5/2019

01-10-2019

Impact of Patient Photos on Detection Accuracy, Decision Confidence and Eye-Tracking Parameters in Chest and Abdomen Images with Tubes and Lines

Author: Elizabeth A. Krupinski

Published in: Journal of Imaging Informatics in Medicine | Issue 5/2019

Login to get access

Abstract

To minimize errors in imaging studies, a camera system was developed that acquires images of patients simultaneously with radiographic images. Thirty-seven chest/abdomen portable radiographs showing central lines, orogastric/nasogastric/endotracheal tubes with patient photographs were viewed by six radiologists while eye-position was recorded. They indicated whether each line/tube was present/absent and rated confidence. Images were shown in three conditions: radiograph only, small, or large photograph with radiograph. There was greater accuracy in detecting tubes with photographs present and decision confidence was generally higher with the photographs. For the eye-tracking parameters, total viewing time, number of fixations, and number of times observers transferred viewing from radiograph to photograph differed as function of whether a photograph was present or absent as well as photograph size. Adding patient photographs to radiographic interpretation of chest and abdomen films can aid in the detection of tubes/lines. If photograph size is large enough, it takes an average of only 3 extra seconds to view compared to the radiograph alone and adds significant confidence to decisions.
Literature
5.
go back to reference Sadigh G, Loehfelm T, Applegate KE, Tridandapani S: Evaluation of near-miss wrong-patient events in radiology reports. Am J Roentgen 205:337–343, 2015CrossRef Sadigh G, Loehfelm T, Applegate KE, Tridandapani S: Evaluation of near-miss wrong-patient events in radiology reports. Am J Roentgen 205:337–343, 2015CrossRef
6.
go back to reference Rubio EI, Hogan L: Time-out: it’s radiology’s turn – incidence of wrong-patient or wrong-study errors. Am J Roentgen 205:941–946, 2015CrossRef Rubio EI, Hogan L: Time-out: it’s radiology’s turn – incidence of wrong-patient or wrong-study errors. Am J Roentgen 205:941–946, 2015CrossRef
7.
go back to reference Ramamurthy S, Bhatti P, Arepalli CD, Salama M, Provenzale JM, Tridandapani T: Integrating patient digital photographs with medical imaging examinations. J Digit Imag 26:875–885, 2013CrossRef Ramamurthy S, Bhatti P, Arepalli CD, Salama M, Provenzale JM, Tridandapani T: Integrating patient digital photographs with medical imaging examinations. J Digit Imag 26:875–885, 2013CrossRef
8.
go back to reference Tridandapani S, Ramamurthy S, Galgano SJ, Provenzale JM: Increasing rate of detection of wrong-patient radiographs: use of photographs obtained at time of radiography. Am J Roentgen 200:W345–W352, 2013CrossRef Tridandapani S, Ramamurthy S, Galgano SJ, Provenzale JM: Increasing rate of detection of wrong-patient radiographs: use of photographs obtained at time of radiography. Am J Roentgen 200:W345–W352, 2013CrossRef
9.
go back to reference Tridandapani S, Ramamurthy S, Provenzale JM, Obuchowski NA, Evanoff MG, Bhatti P: A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors. Acad. Radiol 21:1038–1047, 2014CrossRefPubMedPubMedCentral Tridandapani S, Ramamurthy S, Provenzale JM, Obuchowski NA, Evanoff MG, Bhatti P: A multiobserver study of the effects of including point-of-care patient photographs with portable radiography: a means to detect wrong-patient errors. Acad. Radiol 21:1038–1047, 2014CrossRefPubMedPubMedCentral
10.
go back to reference Krupinski EA, Chung A, Applegate K, DeSimone AK, Tridandapani S: Impact of patient photographs on radiologists’ visual search of chest radiographs. Acad Radiol 23:953–960, 2016CrossRefPubMed Krupinski EA, Chung A, Applegate K, DeSimone AK, Tridandapani S: Impact of patient photographs on radiologists’ visual search of chest radiographs. Acad Radiol 23:953–960, 2016CrossRefPubMed
11.
go back to reference Sadigh G, Applegate KE, Ng TW, Hendrix KA, Tridandapani S: Stakeholders’ perceptions regarding the use of patient photographs integrated with medical imaging studies. J Digit Imag 29:341–346, 2016CrossRef Sadigh G, Applegate KE, Ng TW, Hendrix KA, Tridandapani S: Stakeholders’ perceptions regarding the use of patient photographs integrated with medical imaging studies. J Digit Imag 29:341–346, 2016CrossRef
12.
go back to reference Jensen L, Meyer C: Reducing errors in portable chest radiography. Applied Radiol 44:7–15, 2015 Jensen L, Meyer C: Reducing errors in portable chest radiography. Applied Radiol 44:7–15, 2015
13.
go back to reference Waite S, Scott J, Gale B, Fuchs T, Kolla S, Reede D: Interpretative error in radiology. Am J Roentgen 208:739–749, 2017CrossRef Waite S, Scott J, Gale B, Fuchs T, Kolla S, Reede D: Interpretative error in radiology. Am J Roentgen 208:739–749, 2017CrossRef
14.
go back to reference Fuentealba I, Taylor GA: Diagnostic error with inserted tubes, lines and catheters in children. Ped Radiol 42:1305–3115, 2012CrossRef Fuentealba I, Taylor GA: Diagnostic error with inserted tubes, lines and catheters in children. Ped Radiol 42:1305–3115, 2012CrossRef
15.
go back to reference Nodine CF, Liu H, Miller WT, Kundel HL: Observer performance in the localization of tubes and catheters on digital chest images: the role of expertise and image enhancement. Acad Radiol 3:834–841, 1996CrossRefPubMed Nodine CF, Liu H, Miller WT, Kundel HL: Observer performance in the localization of tubes and catheters on digital chest images: the role of expertise and image enhancement. Acad Radiol 3:834–841, 1996CrossRefPubMed
16.
go back to reference Nodine CF, Kundel HL, Toto LC, Krupinski EA: Recording and analyzing eye-position data using a microcomputer workstation. Behav Res Methods Instrum Comp 24:475–485, 1992CrossRef Nodine CF, Kundel HL, Toto LC, Krupinski EA: Recording and analyzing eye-position data using a microcomputer workstation. Behav Res Methods Instrum Comp 24:475–485, 1992CrossRef
Metadata
Title
Impact of Patient Photos on Detection Accuracy, Decision Confidence and Eye-Tracking Parameters in Chest and Abdomen Images with Tubes and Lines
Author
Elizabeth A. Krupinski
Publication date
01-10-2019
Publisher
Springer International Publishing
Published in
Journal of Imaging Informatics in Medicine / Issue 5/2019
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-019-00202-6

Other articles of this Issue 5/2019

Journal of Digital Imaging 5/2019 Go to the issue