Skip to main content
Top
Published in: Journal of Digital Imaging 4/2011

01-08-2011

Early Experience Using an Online Reporting System for Interventional Radiology Procedure-Related Complications Integrated with a Digital Dictation System

Authors: Sanjay Gupta, Jay Patel, Kevin McEnery, Michael J. Wallace, Kamran Ahrar, Chuck Suitor, Marshall E. Hicks

Published in: Journal of Imaging Informatics in Medicine | Issue 4/2011

Login to get access

Abstract

The absence of user-friendly systems for reporting complications is a major barrier to improving quality assurance (QA) programs in interventional radiology (IR) services. We describe the implementation of a QA application that is completely integrated with the radiology dictation system. We implemented an IR QA process as a module within the electronic medical record and radiologist dictation system applications used at our institution. After a radiologist completes a dictation, he or she must select from a drop-down list of complications before proceeding to the next case. Delayed QA events can be entered using the same applications. All complication entries are sent to a database, which is queried to run reports. During the study period, all the 20,034 interventional procedures were entered in the QA database, 1,144 complications were reported, 110 (9.6%) of which were classified as major. Although majority of the complications (996) were entered at the time of dictation, 148 complications (12.9%) were entered afterwards. All major complications were referred to the IR peer review committee, and 30 of these were discussed in the morbidity and mortality meetings. We studied post-lung-biopsy pneumothorax and chest tube rates and initiated a quality improvement process based on the results.The integration of the IR QA reporting system into the workflow process and the mandatory requirements for completion has the potential to minimize the work effort required to enter complication data, and improve participation in the QA process.
Literature
1.
go back to reference Barraclough BH, Birch J: Health care safety and quality: where have we been and where are we going? Med J Aust 184:S48–50, 2006PubMed Barraclough BH, Birch J: Health care safety and quality: where have we been and where are we going? Med J Aust 184:S48–50, 2006PubMed
2.
go back to reference Becher EC, Chassin MR: Improving the quality of health care: who will lead? Health Aff (Millwood) 20:164–179, 2001CrossRef Becher EC, Chassin MR: Improving the quality of health care: who will lead? Health Aff (Millwood) 20:164–179, 2001CrossRef
3.
go back to reference Donnelly LF, Strife JL: Performance-based assessment of radiology faculty: a practical plan to promote improvement and meet JCAHO standards. AJR Am J Roentgenol 184:1398–1401, 2005PubMed Donnelly LF, Strife JL: Performance-based assessment of radiology faculty: a practical plan to promote improvement and meet JCAHO standards. AJR Am J Roentgenol 184:1398–1401, 2005PubMed
5.
go back to reference Walsh K, Antony J: Improving patient safety and quality: what are the challenges and gaps in introducing an integrated electronic adverse incident and recording system within health care industry? Int J Health Care Qual Assur 20:107–115, 2007PubMedCrossRef Walsh K, Antony J: Improving patient safety and quality: what are the challenges and gaps in introducing an integrated electronic adverse incident and recording system within health care industry? Int J Health Care Qual Assur 20:107–115, 2007PubMedCrossRef
6.
go back to reference Deitch CH, Chan WC, Sunshine JH, Zinninger MD, Cascade PN, Cochran ST: Quality assessment and improvement: what radiologists do and think. AJR Am J Roentgenol 163:1245–1254, 1994PubMed Deitch CH, Chan WC, Sunshine JH, Zinninger MD, Cascade PN, Cochran ST: Quality assessment and improvement: what radiologists do and think. AJR Am J Roentgenol 163:1245–1254, 1994PubMed
7.
go back to reference Frank MS, Mann FA, Gillespy T: Quality assurance: a system that integrates a digital dictation system with a computer data base. AJR Am J Roentgenol 161:1101–1103, 1993PubMed Frank MS, Mann FA, Gillespy T: Quality assurance: a system that integrates a digital dictation system with a computer data base. AJR Am J Roentgenol 161:1101–1103, 1993PubMed
8.
go back to reference Johnson CD, Krecke KN, Roberts RM, Denham C: Quality initiatives: developing a radiology quality and safety program: a primer. Radiographics 29:951–959, 2009PubMedCrossRef Johnson CD, Krecke KN, Roberts RM, Denham C: Quality initiatives: developing a radiology quality and safety program: a primer. Radiographics 29:951–959, 2009PubMedCrossRef
9.
go back to reference Kruskal JB, Yam CS, Sosna J, Hallett DT, Milliman YJ, Kressel HY: Implementation of online radiology quality assurance reporting system for performance improvement: initial evaluation. Radiology 241:518–527, 2006PubMedCrossRef Kruskal JB, Yam CS, Sosna J, Hallett DT, Milliman YJ, Kressel HY: Implementation of online radiology quality assurance reporting system for performance improvement: initial evaluation. Radiology 241:518–527, 2006PubMedCrossRef
10.
go back to reference Mahgerefteh S, Kruskal JB, Yam CS, Blachar A, Sosna J: Peer review in diagnostic radiology: current state and a vision for the future. Radiographics 29:1221–1231, 2009PubMedCrossRef Mahgerefteh S, Kruskal JB, Yam CS, Blachar A, Sosna J: Peer review in diagnostic radiology: current state and a vision for the future. Radiographics 29:1221–1231, 2009PubMedCrossRef
11.
go back to reference Kruskal JB, Anderson S, Yam CS, Sosna J: Strategies for establishing a comprehensive quality and performance improvement program in a radiology department. Radiographics 29:315–329, 2009PubMedCrossRef Kruskal JB, Anderson S, Yam CS, Sosna J: Strategies for establishing a comprehensive quality and performance improvement program in a radiology department. Radiographics 29:315–329, 2009PubMedCrossRef
12.
go back to reference Kruskal JB, Siewert B, Anderson SW, Eisenberg RL, Sosna J: Managing an acute adverse event in a radiology department. Radiographics 28:1237–1250, 2008PubMedCrossRef Kruskal JB, Siewert B, Anderson SW, Eisenberg RL, Sosna J: Managing an acute adverse event in a radiology department. Radiographics 28:1237–1250, 2008PubMedCrossRef
13.
go back to reference Guidelines for establishing a quality assurance program in vascular and interventional radiology. J Vasc Interv Radiol 14:S203-207, 2003 Guidelines for establishing a quality assurance program in vascular and interventional radiology. J Vasc Interv Radiol 14:S203-207, 2003
14.
go back to reference FitzGerald R: Radiological error: analysis, standard setting, targeted instruction and teamworking. Eur Radiol 15:1760–1767, 2005PubMedCrossRef FitzGerald R: Radiological error: analysis, standard setting, targeted instruction and teamworking. Eur Radiol 15:1760–1767, 2005PubMedCrossRef
15.
go back to reference Renfrew DL, Franken Jr, EA, Berbaum KS, Weigelt FH, Abu-Yousef MM: Error in radiology: classification and lessons in 182 cases presented at a problem case conference. Radiology 183:145–150, 1992PubMed Renfrew DL, Franken Jr, EA, Berbaum KS, Weigelt FH, Abu-Yousef MM: Error in radiology: classification and lessons in 182 cases presented at a problem case conference. Radiology 183:145–150, 1992PubMed
16.
go back to reference Soffa DJ, Lewis RS, Sunshine JH, Bhargavan M: Disagreement in interpretation: a method for the development of benchmarks for quality assurance in imaging. J Am Coll Radiol 1:212–217, 2004PubMedCrossRef Soffa DJ, Lewis RS, Sunshine JH, Bhargavan M: Disagreement in interpretation: a method for the development of benchmarks for quality assurance in imaging. J Am Coll Radiol 1:212–217, 2004PubMedCrossRef
17.
go back to reference Hahn PF, Lee MJ, Gazelle GS, Forman BH, Mueller PR: A simplified HyperCard data base for patient management in an interventional practice: experience with more than 4000 cases. AJR Am J Roentgenol 162:1443–1446, 1994PubMed Hahn PF, Lee MJ, Gazelle GS, Forman BH, Mueller PR: A simplified HyperCard data base for patient management in an interventional practice: experience with more than 4000 cases. AJR Am J Roentgenol 162:1443–1446, 1994PubMed
18.
go back to reference Mayo-Smith WW, Jayaraman MV, Han RS, Dupuy DE, Movson JS: Multiinstitutional computer database for recording nonvascular imaging-guided interventions. AJR Am J Roentgenol 181:1491–1493, 2003PubMed Mayo-Smith WW, Jayaraman MV, Han RS, Dupuy DE, Movson JS: Multiinstitutional computer database for recording nonvascular imaging-guided interventions. AJR Am J Roentgenol 181:1491–1493, 2003PubMed
19.
go back to reference McEnery KW, Suitor CT, Hildebrand S, Downs R. RadStation: client-based digital dictation system and integrated clinical information display with an embedded Web-browser. Proc AMIA Symp :561-564, 2000 McEnery KW, Suitor CT, Hildebrand S, Downs R. RadStation: client-based digital dictation system and integrated clinical information display with an embedded Web-browser. Proc AMIA Symp :561-564, 2000
20.
go back to reference McEnery KW, Suitor CT, Hildebrand S, Downs RL: Integration of radiologist peer review into clinical review workstation. J Digit Imaging 13:101–104, 2000PubMedCrossRef McEnery KW, Suitor CT, Hildebrand S, Downs RL: Integration of radiologist peer review into clinical review workstation. J Digit Imaging 13:101–104, 2000PubMedCrossRef
21.
go back to reference McEnery KW, Suitor CT, Hildebrand S, Downs RL: Radiologist's clinical information review workstation interfaced with digital dictation system. J Digit Imaging 13:45–48, 2000PubMedCrossRef McEnery KW, Suitor CT, Hildebrand S, Downs RL: Radiologist's clinical information review workstation interfaced with digital dictation system. J Digit Imaging 13:45–48, 2000PubMedCrossRef
Metadata
Title
Early Experience Using an Online Reporting System for Interventional Radiology Procedure-Related Complications Integrated with a Digital Dictation System
Authors
Sanjay Gupta
Jay Patel
Kevin McEnery
Michael J. Wallace
Kamran Ahrar
Chuck Suitor
Marshall E. Hicks
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 4/2011
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-010-9319-0

Other articles of this Issue 4/2011

Journal of Digital Imaging 4/2011 Go to the issue