Evaluation of Stylus for Radiographic Image Annotation

Authors: Gautam S. Muralidhar, Gary J. Whitman, Tamara Miner Haygood, Tanya W. Stephens, Alan C. Bovik, Mia K. Markey

Published in: Journal of Imaging Informatics in Medicine | Issue 6/2010

Login to get access

Abstract

We evaluated the use of a stylus as a computer interface for radiographic image annotation. Our case study concerned the annotation of spiculated lesions on mammograms. Three experienced radiologists annotated 20 mammograms depicting spiculated lesions. We evaluated the interobserver agreement in annotations marked with a stylus versus those marked with a mouse using the intraclass correlation coefficient. Better agreement in annotating spicule width was observed with the stylus, suggesting that it is easier to accurately annotate subtle regions on an image using a stylus.
Literature
1.
go back to reference Reiner B, Siegel E: Radiology reporting: returning to our image-centric roots. AJR Am J Roentgenol 187:1151–1155, 2006CrossRefPubMed Reiner B, Siegel E: Radiology reporting: returning to our image-centric roots. AJR Am J Roentgenol 187:1151–1155, 2006CrossRefPubMed
2.
go back to reference Zheng Y, Wu M, Cole E, Pisano ED: Online annotation tool for digital mammography. Acad Radiol 11:566–572, 2004CrossRefPubMed Zheng Y, Wu M, Cole E, Pisano ED: Online annotation tool for digital mammography. Acad Radiol 11:566–572, 2004CrossRefPubMed
3.
go back to reference Sampat MP, Bovik AC, Whitman GJ, Markey MK: A model-based framework for the detection of spiculated masses on mammography. Med Phys 35:2110–2123, 2008CrossRefPubMed Sampat MP, Bovik AC, Whitman GJ, Markey MK: A model-based framework for the detection of spiculated masses on mammography. Med Phys 35:2110–2123, 2008CrossRefPubMed
4.
go back to reference Sampat MP, et al: The reliability of measuring physical characteristics of spiculated masses on mammography. Br J Radiol 79:S134–S140, 2006CrossRefPubMed Sampat MP, et al: The reliability of measuring physical characteristics of spiculated masses on mammography. Br J Radiol 79:S134–S140, 2006CrossRefPubMed
5.
go back to reference Heath M, Bowyer KW, Kopans D, Moore R, Kegelmeyer P, Jr.: The digital database for screening mammography. Proceedings of the 5th International Workshop on Digital Mammography Heath M, Bowyer KW, Kopans D, Moore R, Kegelmeyer P, Jr.: The digital database for screening mammography. Proceedings of the 5th International Workshop on Digital Mammography
7.
go back to reference Abramoff MD, Magelhaes PJ, Ram SJ: Image processing with ImageJ. Biophoton Int 11:36–42, 2004 Abramoff MD, Magelhaes PJ, Ram SJ: Image processing with ImageJ. Biophoton Int 11:36–42, 2004
8.
go back to reference McGraw KO, Wong SP: Forming inferences about some intraclass correlation coefficients. Psychol Methods 1:30–46, 1996CrossRef McGraw KO, Wong SP: Forming inferences about some intraclass correlation coefficients. Psychol Methods 1:30–46, 1996CrossRef
9.
go back to reference Rosner B: Fundamentals of Biostatistics, Belmont: Duxbury, 2005 Rosner B: Fundamentals of Biostatistics, Belmont: Duxbury, 2005
10.
go back to reference Krupinski EA, Kallergi M: Choosing a radiology workstation: technical and clinical considerations. Radiology 242:671–682, 2007CrossRefPubMed Krupinski EA, Kallergi M: Choosing a radiology workstation: technical and clinical considerations. Radiology 242:671–682, 2007CrossRefPubMed
Metadata
Title
Evaluation of Stylus for Radiographic Image Annotation
Authors
Gautam S. Muralidhar
Gary J. Whitman
Tamara Miner Haygood
Tanya W. Stephens
Alan C. Bovik
Mia K. Markey
Publication date
01-12-2010
Publisher
Springer-Verlag
Published in
Journal of Imaging Informatics in Medicine / Issue 6/2010
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9232-6

Other articles of this Issue 6/2010

Journal of Digital Imaging 6/2010 Go to the issue