Skip to main content
Top
Published in: Journal of Digital Imaging 6/2009

Open Access 01-12-2009

Image Texture Characterization Using the Discrete Orthonormal S-Transform

Published in: Journal of Imaging Informatics in Medicine | Issue 6/2009

Login to get access

Abstract

We present a new efficient approach for characterizing image texture based on a recently published discrete, orthonormal space-frequency transform known as the DOST. We develop a frequency-domain implementation of the DOST in two dimensions for the case of dyadic frequency sampling. Then, we describe a rapid and efficient approach to obtain local spatial frequency information for an image and show that this information can be used to characterize the horizontal and vertical frequency patterns in synthetic images. Finally, we demonstrate that DOST components can be combined to obtain a rotationally invariant set of texture features that can accurately classify a series of texture patterns. The DOST provides the computational efficiency and multi-scale information of wavelet transforms, while providing texture features in terms of Fourier frequencies. It outperforms leading wavelet-based texture analysis methods.
Appendix
Available only for authorised users
Literature
1.
go back to reference Castleman KR: Digital Image Processing, Upper Saddle River, NJ, USA: Prentice Hall, 1996 Castleman KR: Digital Image Processing, Upper Saddle River, NJ, USA: Prentice Hall, 1996
2.
go back to reference Lerski RA, Straughan K, Schad LR, Boyce D, Bluml S, Zuna I: MR image texture analysis—an approach to tissue characterization. Magn Reson Imaging 11:873–887, 1993CrossRefPubMed Lerski RA, Straughan K, Schad LR, Boyce D, Bluml S, Zuna I: MR image texture analysis—an approach to tissue characterization. Magn Reson Imaging 11:873–887, 1993CrossRefPubMed
3.
go back to reference Castellano G, Bonilha L, Li LM, Cendes F: Texture analysis of medical images. Clin Radiol 59:1061–1069, 2004CrossRefPubMed Castellano G, Bonilha L, Li LM, Cendes F: Texture analysis of medical images. Clin Radiol 59:1061–1069, 2004CrossRefPubMed
4.
go back to reference Yu O, Mauss Y, Zollner G, Namer IJ, Chambron J: Distinct patterns of active and non-active plaques using texture analysis on brain NMR images in multiple sclerosis patients: preliminary results. Magn Reson Imaging 17:1261–1267, 1999CrossRefPubMed Yu O, Mauss Y, Zollner G, Namer IJ, Chambron J: Distinct patterns of active and non-active plaques using texture analysis on brain NMR images in multiple sclerosis patients: preliminary results. Magn Reson Imaging 17:1261–1267, 1999CrossRefPubMed
5.
go back to reference Mathias JM, Tofts PS, Losseff NA: Texture analysis of spinal cord pathology in multiple sclerosis. Magn Reson Med 42:929–935, 1999CrossRefPubMed Mathias JM, Tofts PS, Losseff NA: Texture analysis of spinal cord pathology in multiple sclerosis. Magn Reson Med 42:929–935, 1999CrossRefPubMed
6.
go back to reference Mahmoud-Ghoneim D, Toussaint G, Constans JM, de Certaines JD: Three dimensional texture analysis in MRI: a preliminary evaluation in gliomas. Magn Reson Imaging 21:983–987, 2003CrossRefPubMed Mahmoud-Ghoneim D, Toussaint G, Constans JM, de Certaines JD: Three dimensional texture analysis in MRI: a preliminary evaluation in gliomas. Magn Reson Imaging 21:983–987, 2003CrossRefPubMed
7.
go back to reference Jirak D, Dezortova M, Taimr P, Hajek M: Texture analysis of human liver. J Magn Reson Imaging 15:68–74, 2002CrossRefPubMed Jirak D, Dezortova M, Taimr P, Hajek M: Texture analysis of human liver. J Magn Reson Imaging 15:68–74, 2002CrossRefPubMed
8.
go back to reference Kerut EK, Given M, Giles TD: Review of methods for texture analysis of myocardium from echocardiographic images: a means of tissue characterization. Echocardiography 20:727–736, 2003CrossRefPubMed Kerut EK, Given M, Giles TD: Review of methods for texture analysis of myocardium from echocardiographic images: a means of tissue characterization. Echocardiography 20:727–736, 2003CrossRefPubMed
9.
go back to reference Mayerhoefer ME, Breitenseher MJ, Kramer J, Aigner N, Hofmann S, Materka A: Texture analysis for tissue discrimination on T1-weighted MR images of the knee joint in a multicenter study: Transferability of texture features and comparison of feature selection methods and classifiers. J Magn Reson Imaging 22:674–680, 2005CrossRefPubMed Mayerhoefer ME, Breitenseher MJ, Kramer J, Aigner N, Hofmann S, Materka A: Texture analysis for tissue discrimination on T1-weighted MR images of the knee joint in a multicenter study: Transferability of texture features and comparison of feature selection methods and classifiers. J Magn Reson Imaging 22:674–680, 2005CrossRefPubMed
10.
go back to reference Schilling T, Miroslaw L, Glab G, Smereka M: Towards rapid cervical cancer diagnosis: Automated detection and classification of pathologic cells in phase-contrast images. Int J Gynecol Cancer 17:118–126, 2007CrossRefPubMed Schilling T, Miroslaw L, Glab G, Smereka M: Towards rapid cervical cancer diagnosis: Automated detection and classification of pathologic cells in phase-contrast images. Int J Gynecol Cancer 17:118–126, 2007CrossRefPubMed
11.
go back to reference Haralick RM: Statistical and structural approaches to texture. Proc. IEEE 67:786–808, 1979CrossRef Haralick RM: Statistical and structural approaches to texture. Proc. IEEE 67:786–808, 1979CrossRef
12.
go back to reference McNitt-Gray MF, Wyckoff N, Sayre JW, Goldin JG, Aberle DR: The effects of co-occurrence matrix based texture parameters on the classification of solitary pulmonary nodules imaged on computed tomography. Comput Med Imaging Graph 23:339–348, 1999CrossRefPubMed McNitt-Gray MF, Wyckoff N, Sayre JW, Goldin JG, Aberle DR: The effects of co-occurrence matrix based texture parameters on the classification of solitary pulmonary nodules imaged on computed tomography. Comput Med Imaging Graph 23:339–348, 1999CrossRefPubMed
13.
go back to reference Zhang Y, Zhu H, Ferrari R, Wei X, Eliasziw M, Metz LM, Mitchell JR: Texture analysis of MR images of minocycline treated MS patients. Lect Notes Comp Sci 2878:786–793, 2003 Zhang Y, Zhu H, Ferrari R, Wei X, Eliasziw M, Metz LM, Mitchell JR: Texture analysis of MR images of minocycline treated MS patients. Lect Notes Comp Sci 2878:786–793, 2003
14.
go back to reference Daubechies I: Ten Lectures on Wavelets, Philadelphia, PA: Society for Industrial and Applied Mathematics (SIAM), 1992 Daubechies I: Ten Lectures on Wavelets, Philadelphia, PA: Society for Industrial and Applied Mathematics (SIAM), 1992
15.
go back to reference Weyn B, van de Wouwer G, van Daele A, Scheunders P, van Dyck D, van Marck E, Jacob W: Automated breast tumor diagnosis and grading based on wavelet chromatin texture description. Cytometry 33:32–40, 1998CrossRefPubMed Weyn B, van de Wouwer G, van Daele A, Scheunders P, van Dyck D, van Marck E, Jacob W: Automated breast tumor diagnosis and grading based on wavelet chromatin texture description. Cytometry 33:32–40, 1998CrossRefPubMed
16.
go back to reference Gibson PC, Lamoureux MP, Margrave GF: Stockwell and wavelet transforms. J Fourier Anal Appl 12:713–721, 2006CrossRef Gibson PC, Lamoureux MP, Margrave GF: Stockwell and wavelet transforms. J Fourier Anal Appl 12:713–721, 2006CrossRef
17.
go back to reference Stockwell RG, Mansinha L, Lowe RP: Localization of the complex spectrum: the S transform. IEEE Trans Signal Process 44:998–1001, 1996CrossRef Stockwell RG, Mansinha L, Lowe RP: Localization of the complex spectrum: the S transform. IEEE Trans Signal Process 44:998–1001, 1996CrossRef
18.
go back to reference Pinnegar CR, Eaton DW: Application of the S transform to prestack noise attenuation filtering. J Geophys Res 108:2422, 2003CrossRef Pinnegar CR, Eaton DW: Application of the S transform to prestack noise attenuation filtering. J Geophys Res 108:2422, 2003CrossRef
19.
go back to reference Aldas GU: Application of the Stockwell transform to blasting-induced ground vibration. Int J Surf Min Reclam Environ 19:100–107, 2005CrossRef Aldas GU: Application of the Stockwell transform to blasting-induced ground vibration. Int J Surf Min Reclam Environ 19:100–107, 2005CrossRef
20.
go back to reference Oldenborger GA, Schincariol RA, Mansinha L: Space-local spectral texture segmentation applied to characterizing the heterogeneity of hydraulic conductivity. Water Resour Res 38:1154, 2002CrossRef Oldenborger GA, Schincariol RA, Mansinha L: Space-local spectral texture segmentation applied to characterizing the heterogeneity of hydraulic conductivity. Water Resour Res 38:1154, 2002CrossRef
21.
go back to reference Clapson AC, Barsuglia M, Bizouard MA, Brisson V, Cavalier F, Davier M, Hello P, Kreckelberg S, Varvella M: A gravitational wave burst search method based on the S transform. Classical Quant Grav 22:S1381–S1390, 2005CrossRef Clapson AC, Barsuglia M, Bizouard MA, Brisson V, Cavalier F, Davier M, Hello P, Kreckelberg S, Varvella M: A gravitational wave burst search method based on the S transform. Classical Quant Grav 22:S1381–S1390, 2005CrossRef
22.
go back to reference Reddy JB, Mohanta DK, Karan BM: Power system disturbance recognition using wavelet and S-transform techniques. International Journal of Emerging Electric Power Systems 1:1007, 2004CrossRef Reddy JB, Mohanta DK, Karan BM: Power system disturbance recognition using wavelet and S-transform techniques. International Journal of Emerging Electric Power Systems 1:1007, 2004CrossRef
23.
go back to reference Khosravani H, Pinnegar CR, Mitchell JR, Bardakjian BL, Federico P, Carlen PL: Increased high-frequency oscillations precede in vitro low-Mg2+ seizures. Epilepsia 46:1188–1197, 2005CrossRefPubMed Khosravani H, Pinnegar CR, Mitchell JR, Bardakjian BL, Federico P, Carlen PL: Increased high-frequency oscillations precede in vitro low-Mg2+ seizures. Epilepsia 46:1188–1197, 2005CrossRefPubMed
24.
go back to reference Goodyear BG, Zhu H, Brown RA, Mitchell JR: Removal of phase artifacts from fMRI data using a Stockwell transform filter improves brain activity detection. Magn Reson Med 51:16–21, 2004CrossRefPubMed Goodyear BG, Zhu H, Brown RA, Mitchell JR: Removal of phase artifacts from fMRI data using a Stockwell transform filter improves brain activity detection. Magn Reson Med 51:16–21, 2004CrossRefPubMed
25.
go back to reference Assous S, Humeau A, Tartas M, Abraham P, L’Huillier JP: S-transform applied to laser Doppler flowmetry reactive hyperemia signals. IEEE Trans Biomed Eng 53:1032–1037, 2006CrossRefPubMed Assous S, Humeau A, Tartas M, Abraham P, L’Huillier JP: S-transform applied to laser Doppler flowmetry reactive hyperemia signals. IEEE Trans Biomed Eng 53:1032–1037, 2006CrossRefPubMed
26.
go back to reference Brown RA, Zhu H, Mitchell JR: Distributed vector processing of a new local multiscale Fourier transform for medical imaging applications. IEEE Trans Med Imaging 24:689–691, 2005CrossRefPubMed Brown RA, Zhu H, Mitchell JR: Distributed vector processing of a new local multiscale Fourier transform for medical imaging applications. IEEE Trans Med Imaging 24:689–691, 2005CrossRefPubMed
27.
go back to reference Mansinha L, Stockwell RG, Lowe RP: Pattern analysis with two-dimensional spectral localisation: Appliations of two-dimensional S transforms. Physica A 239:286–295, 1997CrossRef Mansinha L, Stockwell RG, Lowe RP: Pattern analysis with two-dimensional spectral localisation: Appliations of two-dimensional S transforms. Physica A 239:286–295, 1997CrossRef
28.
go back to reference Brown R, Zlatescu M, Sijben A, Roldan G, Easaw J, Forsyth P, Parney I, Sevick R, Yan E, Demetrick D, Schiff D, Cairncross G, Mitchell R: The use of magnetic resonance imaging to noninvasively detect genetic signatures in oligodendroglioma. Clin Cancer Res 14:2357–2362, 2008CrossRefPubMed Brown R, Zlatescu M, Sijben A, Roldan G, Easaw J, Forsyth P, Parney I, Sevick R, Yan E, Demetrick D, Schiff D, Cairncross G, Mitchell R: The use of magnetic resonance imaging to noninvasively detect genetic signatures in oligodendroglioma. Clin Cancer Res 14:2357–2362, 2008CrossRefPubMed
29.
go back to reference Zhang Y, Wells J, Buist R, Peeling J, Wee Yong V, Mitchell JR: A novel MRI texture analysis of demyelination and inflammation in relapsing-remitting experimental allergic encephalomyelitis. Lect Notes Comp Sci 4190:760–767, 2006CrossRef Zhang Y, Wells J, Buist R, Peeling J, Wee Yong V, Mitchell JR: A novel MRI texture analysis of demyelination and inflammation in relapsing-remitting experimental allergic encephalomyelitis. Lect Notes Comp Sci 4190:760–767, 2006CrossRef
30.
go back to reference Zhu, H, Wei X, Zhang Y, Mayer GS, Mitchell JR: Temporal texture analysis of normal appearing white matter in multiple sclerosis. Proc 11th Intl Soc Mag Reson Med 277, 2003 Zhu, H, Wei X, Zhang Y, Mayer GS, Mitchell JR: Temporal texture analysis of normal appearing white matter in multiple sclerosis. Proc 11th Intl Soc Mag Reson Med 277, 2003
31.
go back to reference Zhu H, Goodyear BG, Lauzon ML, Brown RA, Mayer GS, Law AG, Mansinha L, Mitchell JR: A new local multi-scale Fourier analysis for medical imaging. Med Phys 30:1134–1141, 2003CrossRefPubMed Zhu H, Goodyear BG, Lauzon ML, Brown RA, Mayer GS, Law AG, Mansinha L, Mitchell JR: A new local multi-scale Fourier analysis for medical imaging. Med Phys 30:1134–1141, 2003CrossRefPubMed
32.
go back to reference Stockwell RG: A basis for efficient representation of the S-transform. Digit Signal Process 17:371–393, 2007CrossRef Stockwell RG: A basis for efficient representation of the S-transform. Digit Signal Process 17:371–393, 2007CrossRef
34.
go back to reference Porter R, Canagarajah N: Robust rotation-invariant texture classification: wavelet, Gabor filter and GMRF based schemes. IEE Proc Vis Image Signal Process 144:180–188, 1997CrossRef Porter R, Canagarajah N: Robust rotation-invariant texture classification: wavelet, Gabor filter and GMRF based schemes. IEE Proc Vis Image Signal Process 144:180–188, 1997CrossRef
Metadata
Title
Image Texture Characterization Using the Discrete Orthonormal S-Transform
Publication date
01-12-2009
Published in
Journal of Imaging Informatics in Medicine / Issue 6/2009
Print ISSN: 2948-2925
Electronic ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-008-9138-8

Other articles of this Issue 6/2009

Journal of Digital Imaging 6/2009 Go to the issue