Skip to main content
Top
Published in: Odontology 3/2016

01-09-2016 | Original Article

Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites

Authors: Sufyan Garoushi, Pekka Vallittu, Akikazu Shinya, Lippo Lassila

Published in: Odontology | Issue 3/2016

Login to get access

Abstract

This study evaluated characteristics of light transmission, degree of monomer conversion and surface microhardness of bulk fill, conventional and fiber-reinforced resin based composites (RBCs) through different incremental thicknesses of resin composite. Working hypotheses was that there are differences in transmission of blue light through RBCs of different kinds and that the thickness of the increments influence the degree of monomer conversion of RBCs. Six bulk fill, three conventional nanohybrid, one short fiber reinforced and one flowable RBCs were evaluated. For each material, four different incremental thicknesses (1, 2, 3 and 4 mm) were considered (n = 5). The specimens were prepared in cylindrical Teflon molds that are open at the top and the bottom sides and cured for 40 s by applying the curing unit. After curing process, the specimens were ground with a silicon carbide paper with a grit size of 1200 and 4000, and then stored dry at 37 °C for 24 h. Light transmission, degree of monomer conversion, surface microhardness were measured and data were analyzed using ANOVA (p = 0.05). There were differences in light transmission of resin composites of various types and brands. Low-viscous bulk fill and short fiber-reinforced RBCs presented higher light transmission compared to resin composites of higher viscosity. Reduced light transmission and lower surface microhardness and DC % at bottom side of the specimen suggests that more attention needs to be paid to ensure proper curing of the resin composite in deep cavities.
Literature
1.
go back to reference Sakaguchi RL, Douglas WH, Peters MC. Curing light performance and polymerization of composite restorative materials. J Dent. 1992;20:183–8.CrossRefPubMed Sakaguchi RL, Douglas WH, Peters MC. Curing light performance and polymerization of composite restorative materials. J Dent. 1992;20:183–8.CrossRefPubMed
2.
go back to reference Goracci C, Cadenaro M, Fontanive L, Giangrosso G, Juloski J, Vichi A, Ferrari M. Polymerizationefficiency and flexural strength of low-stress restorative composites. Dent Mater. 2014;30:688–94.CrossRefPubMed Goracci C, Cadenaro M, Fontanive L, Giangrosso G, Juloski J, Vichi A, Ferrari M. Polymerizationefficiency and flexural strength of low-stress restorative composites. Dent Mater. 2014;30:688–94.CrossRefPubMed
3.
go back to reference SDR. Instructions for use. Milford: Dentsply Caulk; 2012. SDR. Instructions for use. Milford: Dentsply Caulk; 2012.
4.
go back to reference GC everX Posterior. everX Posterior technical manual. GC everX Posterior; 2013. GC everX Posterior. everX Posterior technical manual. GC everX Posterior; 2013.
5.
go back to reference Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Invest. 2014;18:1999–2000.CrossRef Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Invest. 2014;18:1999–2000.CrossRef
6.
go back to reference Garoushi S, Vallittu PK, Lassila LVJ. Short glass fiber reinforced restorative composite resin with semi-inter penetrating polymer network matrix. Dent Mater. 2007;23:1356–62.CrossRefPubMed Garoushi S, Vallittu PK, Lassila LVJ. Short glass fiber reinforced restorative composite resin with semi-inter penetrating polymer network matrix. Dent Mater. 2007;23:1356–62.CrossRefPubMed
7.
go back to reference Garoushi S, Säilynoja E, Vallittu PK, Lassila L. Physical properties and depth of cure of a new short fiber reinforced composite. Dent Mater. 2013;29:835–41.CrossRefPubMed Garoushi S, Säilynoja E, Vallittu PK, Lassila L. Physical properties and depth of cure of a new short fiber reinforced composite. Dent Mater. 2013;29:835–41.CrossRefPubMed
8.
go back to reference Tauböck TT, Tarle Z, Marovic D, Attin T. Pre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion. J Dent. 2015;43:1358–64.CrossRefPubMed Tauböck TT, Tarle Z, Marovic D, Attin T. Pre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion. J Dent. 2015;43:1358–64.CrossRefPubMed
9.
go back to reference Lehtinen J, Laurila T, Lassila LVJ, Tuusa S, Kienanen P, Vallittu PK, Hernberg R. Optical characterization of bisphenol-A-glycidyldimethacrylate-triethyleneglycoldimethacryalate monomers and copolymers. Dent Mater. 2008;24:1324–8.CrossRefPubMed Lehtinen J, Laurila T, Lassila LVJ, Tuusa S, Kienanen P, Vallittu PK, Hernberg R. Optical characterization of bisphenol-A-glycidyldimethacrylate-triethyleneglycoldimethacryalate monomers and copolymers. Dent Mater. 2008;24:1324–8.CrossRefPubMed
10.
go back to reference Pianelli C, Devaux J, Bebelman S, Leloup G. The micro-Raman spectroscopy, a useful tool to determine the degree of conversion of light-activated composite resins. J Biomed Mater Res. 1999;48:675–81.CrossRefPubMed Pianelli C, Devaux J, Bebelman S, Leloup G. The micro-Raman spectroscopy, a useful tool to determine the degree of conversion of light-activated composite resins. J Biomed Mater Res. 1999;48:675–81.CrossRefPubMed
11.
go back to reference Watts DC, Amer O, Combe EC. Characteristics of visible-light-activated composite systems. Br Dent J. 1984;156:209–15.CrossRefPubMed Watts DC, Amer O, Combe EC. Characteristics of visible-light-activated composite systems. Br Dent J. 1984;156:209–15.CrossRefPubMed
12.
go back to reference dos Santos GB, Alto RV, Filho HR, da Silva EM, Fellows CE. Light transmission on dental resin composites. Dent Mater. 2008;24:571–6.CrossRefPubMed dos Santos GB, Alto RV, Filho HR, da Silva EM, Fellows CE. Light transmission on dental resin composites. Dent Mater. 2008;24:571–6.CrossRefPubMed
13.
go back to reference Ilie N, Bucuta S, Dreaenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent. 2013;38:618–25.CrossRefPubMed Ilie N, Bucuta S, Dreaenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent. 2013;38:618–25.CrossRefPubMed
14.
go back to reference Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A. Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials. Dent Mater. 2012;28:521–8.CrossRefPubMed Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A. Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials. Dent Mater. 2012;28:521–8.CrossRefPubMed
15.
go back to reference Flury S, Peutzfeldt A, Lussi A. Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites. Dent Mater. 2014;30:1104–12.CrossRefPubMed Flury S, Peutzfeldt A, Lussi A. Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites. Dent Mater. 2014;30:1104–12.CrossRefPubMed
16.
go back to reference Garoushi S, Vallittu P, Lassila L. Depth of cure and surface microhardness of experimental short fiber-reinforced composite. Acta Odontol Scand. 2008;66:38–42.CrossRefPubMed Garoushi S, Vallittu P, Lassila L. Depth of cure and surface microhardness of experimental short fiber-reinforced composite. Acta Odontol Scand. 2008;66:38–42.CrossRefPubMed
17.
go back to reference Leprince JG, Palin WM, Vanacker J, Sabbagh J, Devaux J, Leloup G. Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent. 2014;42:993–1000.CrossRefPubMed Leprince JG, Palin WM, Vanacker J, Sabbagh J, Devaux J, Leloup G. Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent. 2014;42:993–1000.CrossRefPubMed
18.
go back to reference Musanje L, Darvell BW. Curing-light attenuation in filler-resin restorative materials. Dent Mater. 2006;22:804–17.CrossRefPubMed Musanje L, Darvell BW. Curing-light attenuation in filler-resin restorative materials. Dent Mater. 2006;22:804–17.CrossRefPubMed
19.
go back to reference Masotti AS, Onofrio AB, Conceicao EN, Spohr AM. UV–Vis spectrophotometric direct transmittance analysis of composite resins. Dent Mater. 2007;23:724–30.CrossRefPubMed Masotti AS, Onofrio AB, Conceicao EN, Spohr AM. UV–Vis spectrophotometric direct transmittance analysis of composite resins. Dent Mater. 2007;23:724–30.CrossRefPubMed
20.
go back to reference Emami N, Sjödahl M, Soderhölm K-JM. How filler properties, filler fraction, sample thickness and light source affect light attenuation in particulate filled resin composites. Dent Mater. 2005;21:721–30.CrossRefPubMed Emami N, Sjödahl M, Soderhölm K-JM. How filler properties, filler fraction, sample thickness and light source affect light attenuation in particulate filled resin composites. Dent Mater. 2005;21:721–30.CrossRefPubMed
21.
go back to reference Le Bell AM, Tanner J, Lassila LV, Kangsniemi I, Vallittu PK. Depth of light-initiated polymerization of glass fiber-reinforced composite in a simulated root canal. Int J Prosthodont. 2003;4:403–8. Le Bell AM, Tanner J, Lassila LV, Kangsniemi I, Vallittu PK. Depth of light-initiated polymerization of glass fiber-reinforced composite in a simulated root canal. Int J Prosthodont. 2003;4:403–8.
22.
go back to reference Alshali RZ, Silikas N, Satterthwaite JD. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater. 2013;29:213–7.CrossRef Alshali RZ, Silikas N, Satterthwaite JD. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater. 2013;29:213–7.CrossRef
23.
go back to reference Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig. 2013;17:227–35.CrossRefPubMed Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Investig. 2013;17:227–35.CrossRefPubMed
24.
go back to reference Ilie N, Hickel R. Investigations on a methacrylate-based flowable composite based on the SDR technology. Dent Mater. 2011;27:348–55.CrossRefPubMed Ilie N, Hickel R. Investigations on a methacrylate-based flowable composite based on the SDR technology. Dent Mater. 2011;27:348–55.CrossRefPubMed
25.
go back to reference Leprince J, Palin WM, Mullier T, Devaux J, Leloup G. Investigating filler morphology and mechanical properties of new-shrinkage resin composite types. J Oral Rehabil. 2010;37:364–76.CrossRefPubMed Leprince J, Palin WM, Mullier T, Devaux J, Leloup G. Investigating filler morphology and mechanical properties of new-shrinkage resin composite types. J Oral Rehabil. 2010;37:364–76.CrossRefPubMed
26.
go back to reference Chung KH, Greener EH. Correlation between degree of conversion, filler concentration and mechanical properties of posterior composite resins. J Oral Rehabil. 1990;17:487–94.CrossRefPubMed Chung KH, Greener EH. Correlation between degree of conversion, filler concentration and mechanical properties of posterior composite resins. J Oral Rehabil. 1990;17:487–94.CrossRefPubMed
27.
go back to reference Bouschlicher MR, Rueggeberg FA, Wilson BM. Correlation of bottom-to-top surface microhardness and conversion ratios for a variety of resin composite composition. Oper Dent. 2004;29:698–704.PubMed Bouschlicher MR, Rueggeberg FA, Wilson BM. Correlation of bottom-to-top surface microhardness and conversion ratios for a variety of resin composite composition. Oper Dent. 2004;29:698–704.PubMed
28.
go back to reference Kim EH, Jung KH, Son SA, Hur B, Kwon YH, Park JK. Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites. Restor Dent Endod. 2015;40:128–35.CrossRefPubMedPubMedCentral Kim EH, Jung KH, Son SA, Hur B, Kwon YH, Park JK. Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites. Restor Dent Endod. 2015;40:128–35.CrossRefPubMedPubMedCentral
29.
go back to reference Alrahlah A, Silikas N, Watts DC. Post-cure depth of cure of bulk fill dental resin-composites. Dent Mater. 2014;30:149–54.CrossRefPubMed Alrahlah A, Silikas N, Watts DC. Post-cure depth of cure of bulk fill dental resin-composites. Dent Mater. 2014;30:149–54.CrossRefPubMed
30.
go back to reference Fleming GJ, Awan M, Cooper PR, Sloan AJ. The potential of a resin-composite to be cured to a 4 mm depth. Dent Mater. 2008;24:522–9.CrossRefPubMed Fleming GJ, Awan M, Cooper PR, Sloan AJ. The potential of a resin-composite to be cured to a 4 mm depth. Dent Mater. 2008;24:522–9.CrossRefPubMed
31.
go back to reference Garcia D, Yaman P, Dennison J, Neiva G. Polymerization shrinkage and depth of cure of bulk fill flowable composite resins. Oper Dent. 2013;39:441–8.CrossRefPubMed Garcia D, Yaman P, Dennison J, Neiva G. Polymerization shrinkage and depth of cure of bulk fill flowable composite resins. Oper Dent. 2013;39:441–8.CrossRefPubMed
Metadata
Title
Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites
Authors
Sufyan Garoushi
Pekka Vallittu
Akikazu Shinya
Lippo Lassila
Publication date
01-09-2016
Publisher
Springer Japan
Published in
Odontology / Issue 3/2016
Print ISSN: 1618-1247
Electronic ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-015-0227-0

Other articles of this Issue 3/2016

Odontology 3/2016 Go to the issue