Skip to main content
Top
Published in: Journal of Orthopaedics and Traumatology 4/2014

Open Access 01-12-2014 | Original Article

Variable-angle locking plate with or without double-tiered subchondral support procedure in the treatment of intra-articular distal radius fracture

Authors: Keikichi Kawasaki, Tetsuya Nemoto, Katsunori Inagaki, Kazunari Tomita, Yukio Ueno

Published in: Journal of Orthopaedics and Traumatology | Issue 4/2014

Login to get access

Abstract

Background

Double-tiered subchondral support (DSS) procedure is two-row fixation in which proximal screws support the dorsal subchondral bone, whereas distal screws support the volar central subchondral bone, using the volar variable-angle locking plate to achieve better anatomical reduction. We examined whether DSS improves clinical outcome, complication rate, and loss of correction for dorsally displaced Arbeitsgemeinschaft für Osteosynthesefragen (AO) type C3 distal radius fractures.

Materials and methods

We reviewed dorsally displaced intra-articular AO C3-type distal radius fractures treated at our institutions with a variable-angle volar locking plate. We assessed 49 patients (27 DSS; 22 non-DSS) treated with volar locking plates, with a mean age of 59.9 years and average follow-up of 20.2 months (range 12–56 months). We evaluated differences in functional outcome, complication rates, and loss of correction between groups using radiographic parameters.

Result

There were no differences in clinical outcome and complications. Final volar tilt and ulnar variance were better maintained in the DSS group (P = 0.01 and 0.03). Change in volar tilt of the non-DSS group was more than that of the DSS group (P = 0.00).

Conclusion

Though there were no significant differences in clinical outcomes, we identified a significant reduction in final volar tilt, ulnar variance, and change in volar tilt. DSS procedure is useful to avoid correction loss when treating unstable C3 distal radius fractures and thus would reduce posttraumatic arthrosis.

Level of evidence

Level IV.
Literature
1.
go back to reference McQueen M, Caspers J (1988) Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Br 70(4):649–651PubMed McQueen M, Caspers J (1988) Colles fracture: does the anatomical result affect the final function? J Bone Joint Surg Br 70(4):649–651PubMed
2.
go back to reference Trumble TE, Schmitt SR, Vedder NB (1994) Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg Am 19(2):325–340PubMedCrossRef Trumble TE, Schmitt SR, Vedder NB (1994) Factors affecting functional outcome of displaced intra-articular distal radius fractures. J Hand Surg Am 19(2):325–340PubMedCrossRef
3.
go back to reference Kamei S, Osada D, Tamai K, Kato N, Takai M, Kameda M, Nohara Y (2010) Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model. J Orthop Sci 15(3):357–364PubMedCrossRef Kamei S, Osada D, Tamai K, Kato N, Takai M, Kameda M, Nohara Y (2010) Stability of volar locking plate systems for AO type C3 fractures of the distal radius: biomechanical study in a cadaveric model. J Orthop Sci 15(3):357–364PubMedCrossRef
4.
go back to reference Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 29(1):96–102PubMedCrossRef Orbay JL, Fernandez DL (2004) Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg Am 29(1):96–102PubMedCrossRef
5.
go back to reference Amadio PC, Berquist TH, Smith DK, Ilstrup DM, Cooney WP 3rd, Linscheid RL (1989) Scaphoid malunion. J Hand Surg Am 14(4):679–687PubMedCrossRef Amadio PC, Berquist TH, Smith DK, Ilstrup DM, Cooney WP 3rd, Linscheid RL (1989) Scaphoid malunion. J Hand Surg Am 14(4):679–687PubMedCrossRef
6.
go back to reference Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322PubMedCrossRef Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316–322PubMedCrossRef
7.
go back to reference Osada D, Kamei S, Takai M, Tomizawa K, Tamai K (2007) Malunited fractures of the distal radius treated with corrective osteotomy using volar locking plate and a corticocancellous bone graft following immediate mobilisation. Hand Surg 12(3):183–190PubMedCrossRef Osada D, Kamei S, Takai M, Tomizawa K, Tamai K (2007) Malunited fractures of the distal radius treated with corrective osteotomy using volar locking plate and a corticocancellous bone graft following immediate mobilisation. Hand Surg 12(3):183–190PubMedCrossRef
8.
go back to reference Benson LS, Minihane KP, Stern LD, Eller E, Seshadri R (2006) The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. J Hand Surg Am 31(8):1333–1339PubMedCrossRef Benson LS, Minihane KP, Stern LD, Eller E, Seshadri R (2006) The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. J Hand Surg Am 31(8):1333–1339PubMedCrossRef
9.
go back to reference Rikli DA, Regazzoni P (1996) Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 78(4):588–592PubMed Rikli DA, Regazzoni P (1996) Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br 78(4):588–592PubMed
10.
go back to reference Schneeberger AG, Ip WY, Poon TL, Chow SP (2001) Open reduction and plate fixation of displaced AO type C3 fractures of the distal radius: restoration of articular congruity in eighteen cases. J Orthop Trauma 15(5):350–357PubMedCrossRef Schneeberger AG, Ip WY, Poon TL, Chow SP (2001) Open reduction and plate fixation of displaced AO type C3 fractures of the distal radius: restoration of articular congruity in eighteen cases. J Orthop Trauma 15(5):350–357PubMedCrossRef
11.
go back to reference Figl M, Weninger P, Jurkowitsch J, Hofbauer M, Schauer J, Leixnering M (2010) Unstable distal radius fractures in the elderly patient–volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma 68(4):992–998PubMed Figl M, Weninger P, Jurkowitsch J, Hofbauer M, Schauer J, Leixnering M (2010) Unstable distal radius fractures in the elderly patient–volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma 68(4):992–998PubMed
12.
go back to reference Stanbury SJ, Salo A, Elfar JC (2012) Biomechanical analysis of a volar variable-angle locking plate: the effect of capturing a distal radial styloid fragment. J Hand Surg Am 37(12):2488–2494PubMedCrossRef Stanbury SJ, Salo A, Elfar JC (2012) Biomechanical analysis of a volar variable-angle locking plate: the effect of capturing a distal radial styloid fragment. J Hand Surg Am 37(12):2488–2494PubMedCrossRef
13.
go back to reference Kamano M, Koshimune M, Toyama M, Kazuki K (2005) Palmar plating system for Colles’ fractures—a preliminary report. J Hand Surg Am 30(4):750–755PubMedCrossRef Kamano M, Koshimune M, Toyama M, Kazuki K (2005) Palmar plating system for Colles’ fractures—a preliminary report. J Hand Surg Am 30(4):750–755PubMedCrossRef
14.
go back to reference Valbuena SE, Cogswell LK, Baraziol R, Valenti P (2010) Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases. Chir Main 29(2):109–113PubMedCrossRef Valbuena SE, Cogswell LK, Baraziol R, Valenti P (2010) Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases. Chir Main 29(2):109–113PubMedCrossRef
15.
go back to reference Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27(1):1–6PubMedCentralPubMed Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27(1):1–6PubMedCentralPubMed
16.
17.
go back to reference Mehling I, Muller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM (2010) Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg Am 35(6):885–891PubMedCrossRef Mehling I, Muller LP, Delinsky K, Mehler D, Burkhart KJ, Rommens PM (2010) Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study. J Hand Surg Am 35(6):885–891PubMedCrossRef
Metadata
Title
Variable-angle locking plate with or without double-tiered subchondral support procedure in the treatment of intra-articular distal radius fracture
Authors
Keikichi Kawasaki
Tetsuya Nemoto
Katsunori Inagaki
Kazunari Tomita
Yukio Ueno
Publication date
01-12-2014
Publisher
Springer International Publishing
Published in
Journal of Orthopaedics and Traumatology / Issue 4/2014
Print ISSN: 1590-9921
Electronic ISSN: 1590-9999
DOI
https://doi.org/10.1007/s10195-014-0292-0

Other articles of this Issue 4/2014

Journal of Orthopaedics and Traumatology 4/2014 Go to the issue