Skip to main content
Top
Published in: Clinical and Experimental Nephrology 5/2016

01-10-2016 | Original Article

Prediction of urine volume soon after birth using serum cystatin C

Authors: Atsushi Kasamatsu, Atsushi Ohashi, Shoji Tsuji, Hidetaka Okada, Hideharu Kanzaki, Kazunari Kaneko

Published in: Clinical and Experimental Nephrology | Issue 5/2016

Login to get access

Abstract

Background

Urine volume is an important clinical finding particularly during the early neonatal period. Oliguria is not a sign of impaired renal function but also a predictive factor for various complications and prognoses. It has been postulated that serum cystatin C (S-CysC) is a more sensitive biomarker for renal function than serum creatinine (S-Cr) in both adults and children. The objective of the current study was to investigate whether urine volume during 24 h after birth can be predicted using S-CysC.

Methods

The subjects were 87 infants. The average gestational age was 34.7 ± 2.9 weeks and the average birth weight was 2135 ± 614 g. Blood samples were obtained from either the umbilical cord or the peripheral veins or artery of the newborn at birth. Data regarding the amount of urine volume and fluid intake during the first 24 h of life, maternal S-Cr and S-CysC levels within 48 h before delivery, and neonatal S-Cr and S-CysC levels at birth were collected from the medical records.

Results

A significantly positive correlation was observed between maternal and neonatal S-Cr levels (r = 0.84, p < 0.0001) but not between maternal S-Cr levels and neonatal S-CysC levels (r = −0.069, p = 0.52). A significant negative correlation was seen between neonatal S-CysC levels and urine volume (r = −0.47, p < 0.0001).

Conclusion

The present study findings indicate that it may be possible to use S-CysC levels at birth to predict urine volume during the first 24 h of life.
Literature
1.
go back to reference Otukesh HHR, Rahimzadeh N, Hoseini S. Glomerular function in neonates. Iran J Kidney Dis. 2012;6:166–72.PubMed Otukesh HHR, Rahimzadeh N, Hoseini S. Glomerular function in neonates. Iran J Kidney Dis. 2012;6:166–72.PubMed
2.
go back to reference LE Lao TT, Chin RK, Lam YM. Renal function in the newborn. Newborn creatinine related to birth weight, maturity and maternal creatinine. Gynecol Obstet Invest. 1989;28:70–2.CrossRefPubMed LE Lao TT, Chin RK, Lam YM. Renal function in the newborn. Newborn creatinine related to birth weight, maturity and maternal creatinine. Gynecol Obstet Invest. 1989;28:70–2.CrossRefPubMed
3.
go back to reference Bariciak E, Yasin A, Harrold J, Walker M, Lepage N, Filler G. Preliminary reference intervals for cystatin C and beta-trace protein in preterm and term neonates. Clin Biochem. 2011;44:1156–9.CrossRefPubMed Bariciak E, Yasin A, Harrold J, Walker M, Lepage N, Filler G. Preliminary reference intervals for cystatin C and beta-trace protein in preterm and term neonates. Clin Biochem. 2011;44:1156–9.CrossRefPubMed
4.
go back to reference EL Knight VJ, Spiegelman D, Hillege HL, de Zeeuw D, Curhan GC, de Jong PE. Factors influencing serum cystatin C levels other than renal function and the impact on renal function measurement. Kidney Int. 2004;65:1416–21.CrossRefPubMed EL Knight VJ, Spiegelman D, Hillege HL, de Zeeuw D, Curhan GC, de Jong PE. Factors influencing serum cystatin C levels other than renal function and the impact on renal function measurement. Kidney Int. 2004;65:1416–21.CrossRefPubMed
6.
go back to reference Treiber M, Gorenjak M, Pecovnik Balon B. Serum cystatin-C as a marker of acute kidney injury in the newborn after perinatal hypoxia/asphyxia. Ther Apher Dial. 2014;18:57–67.CrossRefPubMed Treiber M, Gorenjak M, Pecovnik Balon B. Serum cystatin-C as a marker of acute kidney injury in the newborn after perinatal hypoxia/asphyxia. Ther Apher Dial. 2014;18:57–67.CrossRefPubMed
7.
go back to reference Allegaert KMD, van den Anker J. Cystatin C in newborns: a promising renal biomarker in search for standardization and validation. J Matern Fetal Neonatal Med. 2015;28:1833–8.CrossRefPubMed Allegaert KMD, van den Anker J. Cystatin C in newborns: a promising renal biomarker in search for standardization and validation. J Matern Fetal Neonatal Med. 2015;28:1833–8.CrossRefPubMed
8.
go back to reference Prowle JR, Liu YL, Licari E, Bagshaw SM, Egi M, Haase M, et al. Oliguria as predictive biomarker of acute kidney injury in critically ill patients. Crit Care. 2011;15:R172.CrossRefPubMedPubMedCentral Prowle JR, Liu YL, Licari E, Bagshaw SM, Egi M, Haase M, et al. Oliguria as predictive biomarker of acute kidney injury in critically ill patients. Crit Care. 2011;15:R172.CrossRefPubMedPubMedCentral
9.
go back to reference Macedo E, Malhotra R, Bouchard J, Wynn SK, Mehta RL. Oliguria is an early predictor of higher mortality in critically ill patients. Kidney Int. 2011;80:760–7.CrossRefPubMed Macedo E, Malhotra R, Bouchard J, Wynn SK, Mehta RL. Oliguria is an early predictor of higher mortality in critically ill patients. Kidney Int. 2011;80:760–7.CrossRefPubMed
10.
go back to reference Guignard JPTA, Da Cunha O, Gautier E. Glomerular filtration rate in the first three weeks of life. J Pediatr. 1975;87:268–72.CrossRefPubMed Guignard JPTA, Da Cunha O, Gautier E. Glomerular filtration rate in the first three weeks of life. J Pediatr. 1975;87:268–72.CrossRefPubMed
11.
go back to reference Bezerra CT. Vaz Cunha LC, Liborio AB. Defining reduced urine output in neonatal ICU: importance for mortality and acute kidney injury classification. Nephrol Dial Transplant. 2013;28:901–9.CrossRefPubMed Bezerra CT. Vaz Cunha LC, Liborio AB. Defining reduced urine output in neonatal ICU: importance for mortality and acute kidney injury classification. Nephrol Dial Transplant. 2013;28:901–9.CrossRefPubMed
12.
go back to reference Chevalier RL, Campbell F, Brenbridge AN. Prognostic factors in neonatal acute renal failure. Pediatrics. 1984;74:265–72.PubMed Chevalier RL, Campbell F, Brenbridge AN. Prognostic factors in neonatal acute renal failure. Pediatrics. 1984;74:265–72.PubMed
13.
go back to reference Olavarria F, Krause S, Barranco L, Herrmann F, Paez V, Mezzano S, et al. Renal function in full-term newborns following neonatal asphyxia. A prospective study. Clin Pediatr. 1987;26:334–8.CrossRef Olavarria F, Krause S, Barranco L, Herrmann F, Paez V, Mezzano S, et al. Renal function in full-term newborns following neonatal asphyxia. A prospective study. Clin Pediatr. 1987;26:334–8.CrossRef
14.
go back to reference Perlman JM, Tack ED. Renal injury in the asphyxiated newborn infant: relationship to neurologic outcome. J Pediatr. 1988;113:875–9.CrossRefPubMed Perlman JM, Tack ED. Renal injury in the asphyxiated newborn infant: relationship to neurologic outcome. J Pediatr. 1988;113:875–9.CrossRefPubMed
15.
go back to reference Gupta BD, Sharma P, Bagla J, Parakh M, Soni JP. Renal failure in asphyxiated neonates. Indian Pediatr. 2005;42:928–34.PubMed Gupta BD, Sharma P, Bagla J, Parakh M, Soni JP. Renal failure in asphyxiated neonates. Indian Pediatr. 2005;42:928–34.PubMed
16.
go back to reference Yalaz M, Levent E, Olukman M, Calkavur S, Akisu M, Kultursay N. Role of digoxin-like immunoreactive substance in the pathogenesis of transient tachypnea of newborn. Biomed Res Int. 2013;. doi:10.1155/2013/704763. Yalaz M, Levent E, Olukman M, Calkavur S, Akisu M, Kultursay N. Role of digoxin-like immunoreactive substance in the pathogenesis of transient tachypnea of newborn. Biomed Res Int. 2013;. doi:10.​1155/​2013/​704763.
17.
18.
go back to reference Villa P, Jimenez M, Soriano MC, Manzanares J, Casasnovas P. Serum cystatin C concentration as a marker of acute renal dysfunction in critically ill patients. Crit Care. 2005;9:R139–43.CrossRefPubMedPubMedCentral Villa P, Jimenez M, Soriano MC, Manzanares J, Casasnovas P. Serum cystatin C concentration as a marker of acute renal dysfunction in critically ill patients. Crit Care. 2005;9:R139–43.CrossRefPubMedPubMedCentral
19.
go back to reference Laterza OFPC, Scott MG. Cystatin C—an improved estimator of glomerular filtration rate. Clin Chem. 2002;48:699–707.PubMed Laterza OFPC, Scott MG. Cystatin C—an improved estimator of glomerular filtration rate. Clin Chem. 2002;48:699–707.PubMed
20.
go back to reference Zhang Z, Lu B, Sheng X, Jin N. Cystatin C in prediction of acute kidney injury: a systemic review and meta-analysis. Am J Kidney Dis. 2011;58:356–65.CrossRefPubMed Zhang Z, Lu B, Sheng X, Jin N. Cystatin C in prediction of acute kidney injury: a systemic review and meta-analysis. Am J Kidney Dis. 2011;58:356–65.CrossRefPubMed
21.
go back to reference Armangil D, Yurdakok M, Canpolat FE, Korkmaz A, Yigit S, Tekinalp G. Determination of reference values for plasma cystatin C and comparison with creatinine in premature infants. Pediatr Nephrol. 2008;23:2081–3.CrossRefPubMed Armangil D, Yurdakok M, Canpolat FE, Korkmaz A, Yigit S, Tekinalp G. Determination of reference values for plasma cystatin C and comparison with creatinine in premature infants. Pediatr Nephrol. 2008;23:2081–3.CrossRefPubMed
22.
go back to reference Treiber M, Pecovnik-Balon B, Gorenjak M. Cystatin C versus creatinine as a marker of glomerular filtration rate in the newborn. Wien Klin Wochenschr. 2006;118(Suppl 2):66–70.CrossRefPubMed Treiber M, Pecovnik-Balon B, Gorenjak M. Cystatin C versus creatinine as a marker of glomerular filtration rate in the newborn. Wien Klin Wochenschr. 2006;118(Suppl 2):66–70.CrossRefPubMed
23.
go back to reference Ataei N, Bazargani B, Ameli S, Madani A, Javadilarijani F, Moghtaderi M, et al. Early detection of acute kidney injury by serum cystatin C in critically ill children. Pediatr Nephrol. 2014;29:133–8.CrossRefPubMed Ataei N, Bazargani B, Ameli S, Madani A, Javadilarijani F, Moghtaderi M, et al. Early detection of acute kidney injury by serum cystatin C in critically ill children. Pediatr Nephrol. 2014;29:133–8.CrossRefPubMed
24.
go back to reference Narvaez-Sanchez R, Gonzalez L, Salamanca A, Silva M, Rios D, Arevalo S, et al. Cystatin C could be a replacement to serum creatinine for diagnosing and monitoring kidney function in children. Clin Biochem. 2008;41:498–503.CrossRefPubMed Narvaez-Sanchez R, Gonzalez L, Salamanca A, Silva M, Rios D, Arevalo S, et al. Cystatin C could be a replacement to serum creatinine for diagnosing and monitoring kidney function in children. Clin Biochem. 2008;41:498–503.CrossRefPubMed
25.
go back to reference Cho SY, Hahn WH, Lee HJ, Suh JT, Lee A, Cho BS, et al. The clinical significance of serum cystatin C in critically ill newborns with normal serum creatinine. J Clin Lab Anal. 2012;26:267–71.CrossRefPubMed Cho SY, Hahn WH, Lee HJ, Suh JT, Lee A, Cho BS, et al. The clinical significance of serum cystatin C in critically ill newborns with normal serum creatinine. J Clin Lab Anal. 2012;26:267–71.CrossRefPubMed
26.
go back to reference Cataldi L, Mussap M, Bertelli L, Ruzzante N, Fanos V, Plebani M. Cystatin C in healthy women at term pregnancy and in their infant newborns: relationship between maternal and neonatal serum levels and reference values. Am J Perinatol. 1999;16:287–95.CrossRefPubMed Cataldi L, Mussap M, Bertelli L, Ruzzante N, Fanos V, Plebani M. Cystatin C in healthy women at term pregnancy and in their infant newborns: relationship between maternal and neonatal serum levels and reference values. Am J Perinatol. 1999;16:287–95.CrossRefPubMed
27.
go back to reference Bokenkamp A, Dieterich C, Dressler F, Muhlhaus K, Gembruch U, Bald R, et al. Fetal serum concentrations of cystatin C and beta2-microglobulin as predictors of postnatal kidney function. Am J Obstet Gynecol. 2001;185:468–75.CrossRefPubMed Bokenkamp A, Dieterich C, Dressler F, Muhlhaus K, Gembruch U, Bald R, et al. Fetal serum concentrations of cystatin C and beta2-microglobulin as predictors of postnatal kidney function. Am J Obstet Gynecol. 2001;185:468–75.CrossRefPubMed
28.
go back to reference Finney HND, Thakkar H, Fell JM, Price CP. Reference ranges for plasma cystatin C and creatinine measurements in premature infants, neonates, and older children. Arch Dis Child. 2000;82:71–5.CrossRefPubMedPubMedCentral Finney HND, Thakkar H, Fell JM, Price CP. Reference ranges for plasma cystatin C and creatinine measurements in premature infants, neonates, and older children. Arch Dis Child. 2000;82:71–5.CrossRefPubMedPubMedCentral
29.
go back to reference Harmoinen AYE, Ala-Houhala M, Janas M, Kaila M, Kouri T. Reference intervals for cystatin C in pre- and full-term infants and children. Pediatr Nephrol. 2000;15:105–8.CrossRefPubMed Harmoinen AYE, Ala-Houhala M, Janas M, Kaila M, Kouri T. Reference intervals for cystatin C in pre- and full-term infants and children. Pediatr Nephrol. 2000;15:105–8.CrossRefPubMed
30.
go back to reference Abitbol CL, Seeherunvong W, Galarza MG, Katsoufis C, Francoeur D, Defreitas M, et al. Neonatal kidney size and function in preterm infants: what is a true estimate of glomerular filtration rate? J Pediatr. 2014;164:1026–31.CrossRefPubMed Abitbol CL, Seeherunvong W, Galarza MG, Katsoufis C, Francoeur D, Defreitas M, et al. Neonatal kidney size and function in preterm infants: what is a true estimate of glomerular filtration rate? J Pediatr. 2014;164:1026–31.CrossRefPubMed
Metadata
Title
Prediction of urine volume soon after birth using serum cystatin C
Authors
Atsushi Kasamatsu
Atsushi Ohashi
Shoji Tsuji
Hidetaka Okada
Hideharu Kanzaki
Kazunari Kaneko
Publication date
01-10-2016
Publisher
Springer Japan
Published in
Clinical and Experimental Nephrology / Issue 5/2016
Print ISSN: 1342-1751
Electronic ISSN: 1437-7799
DOI
https://doi.org/10.1007/s10157-015-1215-y

Other articles of this Issue 5/2016

Clinical and Experimental Nephrology 5/2016 Go to the issue