Abstract

Endovascular treatment and prognosis of intracranial aneurysms are based on size and volume, which demand more accurate neuroimaging techniques. Aneurysm volume calculation is important to choose endovascular treatment modalities and packing density calculation. Of all these methods, it remains unknown which one is the most accurate to calculate aneurysm volume. The objective of this study is to compare the accuracy of three angiography-based versus three tomographic-based methods which calculate aneurysm volume. A retrospective study which included patients with ruptured and unruptured cerebral aneurysms diagnosed by angiogram and computed tomography angiography (CTA) was done. The accuracy of each method was assessed with an ellipsoid glass model of known volume, which helped us to adjust variation in volumetric measurements done with AngioSuite© and AngioCalc© softwares (based on angiographic and tomographic images), 3D–rotational angiography and 3D–CTA (tridimensional computed tomography angiography), based on measurements of diameters such as maximal width and maximal height. Descriptive statistics, ANOVA for repetitive samples and t test were used. We included 89 patients (126 saccular intracraneal aneurysms). AngioSuite© software (angiography-based) showed more accuracy compared to other methods in our control model. The geometric system (AngioCalc) based on CTA images was statistically different from all other methods studied. AngioCalc (CTA-based) demonstrated a significant difference compared with other methods hence, it may overestimate volume measurements. AngioSuite© software measurements (angiography-based) may be the most accurate method to calculate aneurysm volume.
Literature
4.
go back to reference Tamatani S, Ito Y, Abe H, Koike T, Takeuchi S, Tanaka R (2002) Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms. AJNR Am J Neuroradiol 23(5):762–767PubMed Tamatani S, Ito Y, Abe H, Koike T, Takeuchi S, Tanaka R (2002) Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms. AJNR Am J Neuroradiol 23(5):762–767PubMed
5.
go back to reference Slob MJ, van Rooij WJ, Sluzewski M (2005) Coil thickness and packing of cerebral aneurysms: a comparative study of two types of coils. AJNR Am J Neuroradiol 26(4):901–903PubMed Slob MJ, van Rooij WJ, Sluzewski M (2005) Coil thickness and packing of cerebral aneurysms: a comparative study of two types of coils. AJNR Am J Neuroradiol 26(4):901–903PubMed
8.
go back to reference Woodward K, Forsberg DA (2013) AngioSuite: an accurate method to calculate aneurysm volumes and packing densities. Journal of neurointerventional surgery 5(Suppl 3):iii28–iii32CrossRefPubMed Woodward K, Forsberg DA (2013) AngioSuite: an accurate method to calculate aneurysm volumes and packing densities. Journal of neurointerventional surgery 5(Suppl 3):iii28–iii32CrossRefPubMed
10.
go back to reference Piotin M, Daghman B, Mounayer C, Spelle L, Moret J (2006) Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms. AJNR Am J Neuroradiol 27(4):839–842PubMed Piotin M, Daghman B, Mounayer C, Spelle L, Moret J (2006) Ellipsoid approximation versus 3D rotational angiography in the volumetric assessment of intracranial aneurysms. AJNR Am J Neuroradiol 27(4):839–842PubMed
13.
go back to reference Hanley M, Zenzen WJ, Brown MD, Gaughen JR, Evans AJ (2008) Comparing the accuracy of digital subtraction angiography, CT angiography and MR angiography at estimating the volume of cerebral aneurysms. Interv Neuroradiol: J Peritherapeutic Neuroradiol, Surg Proced Relat Neurosci 14(2):173–177. https://doi.org/10.1177/159101990801400208 CrossRef Hanley M, Zenzen WJ, Brown MD, Gaughen JR, Evans AJ (2008) Comparing the accuracy of digital subtraction angiography, CT angiography and MR angiography at estimating the volume of cerebral aneurysms. Interv Neuroradiol: J Peritherapeutic Neuroradiol, Surg Proced Relat Neurosci 14(2):173–177. https://​doi.​org/​10.​1177/​1591019908014002​08 CrossRef
Metadata
Title
Comparative analysis of aneurysm volume by different methods based on angiography and computed tomography angiography
Authors
Víctor Hugo Escobar-de la Garma, MD
Marco Zenteno
Felipe Padilla-Vázquez
Daniel San-Juan
Aurelio Cerón-Morales
Publication date
01-10-2018
Publisher
Springer Berlin Heidelberg
Published in
Neurosurgical Review / Issue 4/2018
Print ISSN: 0344-5607
Electronic ISSN: 1437-2320
DOI
https://doi.org/10.1007/s10143-018-0943-3

Other articles of this Issue 4/2018

Neurosurgical Review 4/2018 Go to the issue