Skip to main content
Top
Published in: Neuroradiology 6/2003

01-06-2003 | Interventional Neuroradiology

CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study

Authors: M. Piotin, P. Gailloud, L. Bidaut, S. Mandai, M. Muster, J. Moret, D. A. Rüfenacht

Published in: Neuroradiology | Issue 6/2003

Login to get access

Abstract

The purpose of our experimental study was to assess the accuracy and precision of CT angiography (CTA), MR angiography (MRA) and rotational digital subtraction angiography (DSA) for measuring the volume of an in vitro aneurysm model. A rigid model of the anterior cerebral circulation harbouring an anterior communicating aneurysm was connected to a pulsatile circuit. It was studied using unenhanced 3D time-of-flight MRA, contrast-enhanced CTA and rotational DSA angiography. The source images were then postprocessed on dedicated workstations to calculate the volume of the aneurysm. CTA was more accurate than MRA (P=0.0019). Rotational DSA was more accurate than CTA, although the difference did not reach statistical significance (P=0.1605), and significantly more accurate than MRA (P<0.00001). CTA was more precise than MRA (P=0.12), although this did not reach statistical significance. Rotational DSA can be part of the diagnosis, treatment planning and support endovascular treatment of intracranial aneurysms. The emerging endovascular treatment techniques which consist of using liquid polymers as implants to exclude aneurysms from arterial circulation would certainly benefit from this precise measurement of the volume of aneurysms.
Literature
1.
go back to reference Sugiu K, Kinugasa K, Mandai S, Tokunaga K, Ohmoto T (1995) Direct thrombosis of experimental aneurysms with cellulose acetate polymer (CAP): technical aspects, angiographic follow up, and histological study. J Neurosurg 83: 531–538PubMed Sugiu K, Kinugasa K, Mandai S, Tokunaga K, Ohmoto T (1995) Direct thrombosis of experimental aneurysms with cellulose acetate polymer (CAP): technical aspects, angiographic follow up, and histological study. J Neurosurg 83: 531–538PubMed
2.
go back to reference Piotin M, Mandai S, Sugiu K, Gailloud P, Rüfenacht DA (2001) Endovascular treatment of cerebral aneurysms: an in vitro study with detachable platinum coils and tricellulose acetate polymer. Am J Roentgenol 176: 235–239 Piotin M, Mandai S, Sugiu K, Gailloud P, Rüfenacht DA (2001) Endovascular treatment of cerebral aneurysms: an in vitro study with detachable platinum coils and tricellulose acetate polymer. Am J Roentgenol 176: 235–239
3.
go back to reference Nishi S, Taki W, Nakahara I, et al (1996) Embolization of cerebral aneurysms with a liquid embolus, EVAL mixture: report of three cases. Acta Neurochir (Wien) 138: 294–300 Nishi S, Taki W, Nakahara I, et al (1996) Embolization of cerebral aneurysms with a liquid embolus, EVAL mixture: report of three cases. Acta Neurochir (Wien) 138: 294–300
4.
go back to reference Murayama Y, Vinuela F, Tateshima S, Vinuela F Jr, Akiba Y (2000) Endovascular treatment of experimental aneurysms by use of a combination of liquid embolic agents and protective devices. AJNR 21: 1726–1735PubMed Murayama Y, Vinuela F, Tateshima S, Vinuela F Jr, Akiba Y (2000) Endovascular treatment of experimental aneurysms by use of a combination of liquid embolic agents and protective devices. AJNR 21: 1726–1735PubMed
5.
go back to reference Kinugasa K, Mandai S, Tsuchida S, et al (1994) Cellulose acetate polymer thrombosis for the emergency treatment of aneurysms: angiographic findings, clinical experience, and histopathological study. Neurosurgery 34: 694–701PubMed Kinugasa K, Mandai S, Tsuchida S, et al (1994) Cellulose acetate polymer thrombosis for the emergency treatment of aneurysms: angiographic findings, clinical experience, and histopathological study. Neurosurgery 34: 694–701PubMed
6.
go back to reference Kinugasa K, Mandai S, Terai Y, Kamata I, et al (1992) Direct thrombosis of aneurysms with cellulose acetate polymer. Part II: Preliminary clinical experience. J Neurosurg 77: 501–507PubMed Kinugasa K, Mandai S, Terai Y, Kamata I, et al (1992) Direct thrombosis of aneurysms with cellulose acetate polymer. Part II: Preliminary clinical experience. J Neurosurg 77: 501–507PubMed
7.
go back to reference Schwartz RB, Tice HM, Hooten SM, Hsu L, Stieg PE (1994) Evaluation of cerebral aneurysms with helical CT: correlation with conventional angiography and MR angiography. Radiology 192: 717–722PubMed Schwartz RB, Tice HM, Hooten SM, Hsu L, Stieg PE (1994) Evaluation of cerebral aneurysms with helical CT: correlation with conventional angiography and MR angiography. Radiology 192: 717–722PubMed
8.
go back to reference Vieco PT, Shuman WP, Alsofrom GF, Gross CE (1995) Detection of circle of Willis aneurysms in patients with acute subarachnoid hemorrhage: a comparison of CT angiography and digital subtraction angiography. Am J Roentgenol 165: 425–430 Vieco PT, Shuman WP, Alsofrom GF, Gross CE (1995) Detection of circle of Willis aneurysms in patients with acute subarachnoid hemorrhage: a comparison of CT angiography and digital subtraction angiography. Am J Roentgenol 165: 425–430
9.
go back to reference Villablanca JP, Martin N, Jahan R, et al (2000) Volume-rendered helical computerized tomography angiography in the detection and characterization of intracranial aneurysms. J Neurosurg 93: 254–264PubMed Villablanca JP, Martin N, Jahan R, et al (2000) Volume-rendered helical computerized tomography angiography in the detection and characterization of intracranial aneurysms. J Neurosurg 93: 254–264PubMed
10.
go back to reference Atlas SW, Sheppard L, Goldberg HI, Hurst RW, Listerud J, Flamm E (1997) Intracranial aneurysms: detection and characterization with MR angiography with use of an advanced postprocessing technique in a blinded-reader study. Radiology 203: 807–814PubMed Atlas SW, Sheppard L, Goldberg HI, Hurst RW, Listerud J, Flamm E (1997) Intracranial aneurysms: detection and characterization with MR angiography with use of an advanced postprocessing technique in a blinded-reader study. Radiology 203: 807–814PubMed
11.
go back to reference Tanoue S, Kiyosue H, Kenai H, Nakamura T, Yamashita M, Mori H (2000) Three-dimensional reconstructed images after rotational angiography in the evaluation of intracranial aneurysms: surgical correlation. Neurosurgery 47: 866–871PubMed Tanoue S, Kiyosue H, Kenai H, Nakamura T, Yamashita M, Mori H (2000) Three-dimensional reconstructed images after rotational angiography in the evaluation of intracranial aneurysms: surgical correlation. Neurosurgery 47: 866–871PubMed
12.
go back to reference Anxionnat R, Bracard S, Ducrocq X,et al (2001) Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment. Radiology 218: 799–808PubMed Anxionnat R, Bracard S, Ducrocq X,et al (2001) Intracranial aneurysms: clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment. Radiology 218: 799–808PubMed
13.
go back to reference Bidaut LM, Laurent C, Piotin M, et al (1998) Second-generation three-dimensional reconstruction for rotational three-dimensional angiography. Acad Radiol 5: 836–849PubMed Bidaut LM, Laurent C, Piotin M, et al (1998) Second-generation three-dimensional reconstruction for rotational three-dimensional angiography. Acad Radiol 5: 836–849PubMed
14.
go back to reference Missler U, Hundt C, Wiesmann M, Mayer T, Bruckmann H (2000) Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms. Eur Radiol 10: 564–568CrossRefPubMed Missler U, Hundt C, Wiesmann M, Mayer T, Bruckmann H (2000) Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms. Eur Radiol 10: 564–568CrossRefPubMed
15.
go back to reference Gailloud P, Pray JR, Muster M, Piotin M, Fasel JH, Rüfenacht DA (1997) An in vitro anatomic model of the human cerebral arteries with saccular arterial aneurysms. Surg Radiol Anat 19: 119–121PubMed Gailloud P, Pray JR, Muster M, Piotin M, Fasel JH, Rüfenacht DA (1997) An in vitro anatomic model of the human cerebral arteries with saccular arterial aneurysms. Surg Radiol Anat 19: 119–121PubMed
16.
go back to reference Bidaut LM, Pascual-Marqui R, Delavelle J, et al (1996) Three-to-five-dimensional multisensor imaging for the assessment of neurological (dys)function. J Digit Imaging 9: 185–198PubMed Bidaut LM, Pascual-Marqui R, Delavelle J, et al (1996) Three-to-five-dimensional multisensor imaging for the assessment of neurological (dys)function. J Digit Imaging 9: 185–198PubMed
17.
go back to reference Byrne JV, Sohn MJ, Molyneux AJ, Chir B (1999) Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90: 656–663PubMed Byrne JV, Sohn MJ, Molyneux AJ, Chir B (1999) Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding. J Neurosurg 90: 656–663PubMed
18.
go back to reference Cognard C, Weill A, Spelle L, et al (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212: 348–356PubMed Cognard C, Weill A, Spelle L, et al (1999) Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils. Radiology 212: 348–356PubMed
19.
go back to reference Kerber CW, Heilman CB, Zanetti PH (1989) Transparent elastic arterial models. I: A brief technical note. Biorheology 26: 1041–1049PubMed Kerber CW, Heilman CB, Zanetti PH (1989) Transparent elastic arterial models. I: A brief technical note. Biorheology 26: 1041–1049PubMed
20.
go back to reference Kerber CW, Imbesi SG, Knox K (1999) Flow dynamics in a lethal anterior communicating artery aneurysm. AJNR 20: 2000–2003PubMed Kerber CW, Imbesi SG, Knox K (1999) Flow dynamics in a lethal anterior communicating artery aneurysm. AJNR 20: 2000–2003PubMed
21.
go back to reference Steiger HJ, Liepsch DW, Poll A, Reulen HJ (1988) Hemodynamic stress in terminal saccular aneurysms: a laser-Doppler study. Heart Vessels 4: 162–169PubMed Steiger HJ, Liepsch DW, Poll A, Reulen HJ (1988) Hemodynamic stress in terminal saccular aneurysms: a laser-Doppler study. Heart Vessels 4: 162–169PubMed
22.
go back to reference Kallmes DF, Evans AJ, Woodcock RJ, et al (1996) Optimization of parameters for the detection of cerebral aneurysms: CT angiography of a model. Radiology 200: 403–405PubMed Kallmes DF, Evans AJ, Woodcock RJ, et al (1996) Optimization of parameters for the detection of cerebral aneurysms: CT angiography of a model. Radiology 200: 403–405PubMed
23.
go back to reference Dix JE, Evans AJ, Kallmes DF, Sobel AH, Phillips CD (1997) Accuracy and precision of CT angiography in a model of carotid artery bifurcation stenosis. AJNR 18: 409–415 Dix JE, Evans AJ, Kallmes DF, Sobel AH, Phillips CD (1997) Accuracy and precision of CT angiography in a model of carotid artery bifurcation stenosis. AJNR 18: 409–415
24.
go back to reference Wilcock DJ, Jaspan T, Worthington BS (1995) Problems and pitfalls of 3-D TOF magnetic resonance angiography of the intracranial circulation. Clin Radiol 50: 526–532PubMed Wilcock DJ, Jaspan T, Worthington BS (1995) Problems and pitfalls of 3-D TOF magnetic resonance angiography of the intracranial circulation. Clin Radiol 50: 526–532PubMed
25.
go back to reference Pernicone JR, Siebert JE, Potchen EJ, Pera A, Dumoulin CL, Souza SP (1990) Three-dimensional phase-contrast MR angiography in the head and neck: preliminary report. AJNR 11: 457–466 Pernicone JR, Siebert JE, Potchen EJ, Pera A, Dumoulin CL, Souza SP (1990) Three-dimensional phase-contrast MR angiography in the head and neck: preliminary report. AJNR 11: 457–466
26.
go back to reference Huston J 3rd, Rüfenacht DA, Ehman RL, Wiebers DO (1991) Intracranial aneurysms and vascular malformations: comparison of time-of-flight and phase-contrast MR angiography. Radiology 181: 721–730PubMed Huston J 3rd, Rüfenacht DA, Ehman RL, Wiebers DO (1991) Intracranial aneurysms and vascular malformations: comparison of time-of-flight and phase-contrast MR angiography. Radiology 181: 721–730PubMed
27.
go back to reference Liu K, Rutt BK (1998) Sliding interleaved kY (SLINKY) acquisition: a novel 3D MRA technique with suppressed slab boundary artifact. J Magn Reson Imaging 8: 903–911PubMed Liu K, Rutt BK (1998) Sliding interleaved kY (SLINKY) acquisition: a novel 3D MRA technique with suppressed slab boundary artifact. J Magn Reson Imaging 8: 903–911PubMed
Metadata
Title
CT angiography, MR angiography and rotational digital subtraction angiography for volumetric assessment of intracranial aneurysms. An experimental study
Authors
M. Piotin
P. Gailloud
L. Bidaut
S. Mandai
M. Muster
J. Moret
D. A. Rüfenacht
Publication date
01-06-2003
Publisher
Springer-Verlag
Published in
Neuroradiology / Issue 6/2003
Print ISSN: 0028-3940
Electronic ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-002-0922-8

Other articles of this Issue 6/2003

Neuroradiology 6/2003 Go to the issue