Skip to main content
Top
Published in: European Journal of Clinical Microbiology & Infectious Diseases 4/2017

01-04-2017 | Original Article

Reduced length of hospital stay through a point of care placed automated blood culture instrument

Authors: M. J. Bruins, M. J. Egbers, T. M. Israel, S. H. A. Diepeveen, M. J. H. M. Wolfhagen

Published in: European Journal of Clinical Microbiology & Infectious Diseases | Issue 4/2017

Login to get access

Abstract

Early appropriate antimicrobial treatment of patients with sepsis has a large impact on clinical outcome. To enable prompt and efficient processing of blood cultures, the inoculated vials should be placed into an automated continuously monitoring blood culture system immediately after sampling. We placed an extra BACTEC FX instrument at the emergency department of our hospital and validated the twice-daily re-entering of ongoing vials from this instrument into the BACTEC FX at the laboratory. We subsequently assessed the benefits of shortening the transport time between sampling and monitored incubation of blood culture vials by comparing the turnaround times of positive blood cultures from emergency department patients with a historical control group. Re-entering ongoing vials within 2 h raised no technical problems with the BACTEC FX and did not increase the risk of false-negative culture results. The decreased transport time resulted in significantly earlier available Gram stain results for a large proportion of patients in the intervention group and a significant shortening of the median total turnaround time to less than 48 h. The median length of hospital stay shortened by 1 day. Immediate entering of blood culture vials into a point of care placed BACTEC FX instrument and subsequent efficient processing enables earlier decision-making regarding antimicrobial treatment, preventing the development of antimicrobial resistance and reducing healthcare costs.
Literature
1.
go back to reference Fitzpatrick F, Turley M, Humphreys H, Smyth E (2004) An after-hours clinical liaison blood culture service—is it worth it? Clin Microbiol Infect 10:917–921CrossRefPubMed Fitzpatrick F, Turley M, Humphreys H, Smyth E (2004) An after-hours clinical liaison blood culture service—is it worth it? Clin Microbiol Infect 10:917–921CrossRefPubMed
2.
go back to reference Lee CC, Lee NY, Chen PL, Hong MY, Chan TY, Chi CH, Ko WC (2015) Impact of antimicrobial strategies on clinical outcomes of adults with septic shock and community-onset Enterobacteriaceae bacteremia: de-escalation is beneficial. Diagn Microbiol Infect Dis 82:158–164CrossRefPubMed Lee CC, Lee NY, Chen PL, Hong MY, Chan TY, Chi CH, Ko WC (2015) Impact of antimicrobial strategies on clinical outcomes of adults with septic shock and community-onset Enterobacteriaceae bacteremia: de-escalation is beneficial. Diagn Microbiol Infect Dis 82:158–164CrossRefPubMed
3.
go back to reference Nicolau DP (2011) Current challenges in the management of the infected patient. Curr Opin Infect Dis 24(Suppl 1):S1–S10CrossRefPubMed Nicolau DP (2011) Current challenges in the management of the infected patient. Curr Opin Infect Dis 24(Suppl 1):S1–S10CrossRefPubMed
4.
go back to reference Goff DA, File TM Jr (2016) The evolving role of antimicrobial stewardship in management of multidrug resistant infections. Infect Dis Clin North Am 30:539–551CrossRefPubMed Goff DA, File TM Jr (2016) The evolving role of antimicrobial stewardship in management of multidrug resistant infections. Infect Dis Clin North Am 30:539–551CrossRefPubMed
5.
go back to reference Saito T, Iinuma Y, Takakura S, Nagao M, Matsushima A, Shirano M, Ichiyama S (2009) Delayed insertion of blood culture bottles into automated continuously monitoring blood culture systems increases the time from blood sample collection to the detection of microorganisms in bacteremic patients. J Infect Chemother 15:49–53CrossRefPubMed Saito T, Iinuma Y, Takakura S, Nagao M, Matsushima A, Shirano M, Ichiyama S (2009) Delayed insertion of blood culture bottles into automated continuously monitoring blood culture systems increases the time from blood sample collection to the detection of microorganisms in bacteremic patients. J Infect Chemother 15:49–53CrossRefPubMed
6.
go back to reference van der Velden LB, Vos FJ, Mouton JW, Sturm PD (2011) Clinical impact of preincubation of blood cultures at 37°C. J Clin Microbiol 49:275–280CrossRefPubMed van der Velden LB, Vos FJ, Mouton JW, Sturm PD (2011) Clinical impact of preincubation of blood cultures at 37°C. J Clin Microbiol 49:275–280CrossRefPubMed
7.
go back to reference BD (2011) BD Bactec™ FX Instrument User’s Manual. Becton, Dickinson and Company BD (2011) BD Bactec™ FX Instrument User’s Manual. Becton, Dickinson and Company
9.
go back to reference Pouw ME, Peelen LM, Moons KGM, Kalkman CJ, Lingsma HF (2013) Including post-discharge mortality in calculation of hospital standardised mortality ratios: retrospective analysis of hospital episode statistics. BMJ 347:f5913CrossRefPubMedPubMedCentral Pouw ME, Peelen LM, Moons KGM, Kalkman CJ, Lingsma HF (2013) Including post-discharge mortality in calculation of hospital standardised mortality ratios: retrospective analysis of hospital episode statistics. BMJ 347:f5913CrossRefPubMedPubMedCentral
10.
go back to reference Salazar E, Divatia M, Cernoch PL, Olsen RJ, Long SW, Land GA, Davis JR, Musser JM (2015) Improving positive blood culture removal time significantly decreases total processing time. Arch Pathol Lab Med 139:199–203CrossRefPubMed Salazar E, Divatia M, Cernoch PL, Olsen RJ, Long SW, Land GA, Davis JR, Musser JM (2015) Improving positive blood culture removal time significantly decreases total processing time. Arch Pathol Lab Med 139:199–203CrossRefPubMed
11.
go back to reference BD (2015) BD BACTEC™ 9240/9120 System User’s Manual. Becton, Dickinson and Company BD (2015) BD BACTEC™ 9240/9120 System User’s Manual. Becton, Dickinson and Company
12.
go back to reference Koh EH, Lee DH, Kim S (2014) Effects of preincubating blood culture bottles at 37degrees C during the night shift and of collected blood volume on time to detection and days to final report. Ann Clin Microbiol 17:14–19 Koh EH, Lee DH, Kim S (2014) Effects of preincubating blood culture bottles at 37degrees C during the night shift and of collected blood volume on time to detection and days to final report. Ann Clin Microbiol 17:14–19
13.
go back to reference Lemming L, Holt HM, Petersen IS, Østergaard C, Bruun B (2004) Bactec 9240 blood culture system: to preincubate at 35 degrees C or not? Clin Microbiol Infect 10:1089–1091CrossRefPubMed Lemming L, Holt HM, Petersen IS, Østergaard C, Bruun B (2004) Bactec 9240 blood culture system: to preincubate at 35 degrees C or not? Clin Microbiol Infect 10:1089–1091CrossRefPubMed
Metadata
Title
Reduced length of hospital stay through a point of care placed automated blood culture instrument
Authors
M. J. Bruins
M. J. Egbers
T. M. Israel
S. H. A. Diepeveen
M. J. H. M. Wolfhagen
Publication date
01-04-2017
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Clinical Microbiology & Infectious Diseases / Issue 4/2017
Print ISSN: 0934-9723
Electronic ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-016-2837-z

Other articles of this Issue 4/2017

European Journal of Clinical Microbiology & Infectious Diseases 4/2017 Go to the issue