Abstract

The yield of blood cultures is proportional to the volume of blood cultured. We evaluated an automatic blood volume monitoring system, recently developed by Becton Dickinson within its BACTEC EpiCenter module, that calculates mean volumes of negative aerobic bottles and generates boxplots and histograms. First, we evaluated the filling degree of 339 aerobic glass blood cultures by calculating the weight-based volume for each bottle. A substantial amount of the bottles (48.3 %) were inadequately filled. Evaluation of the accuracy of the monitoring system showed a mean bias of −1.4 mL (−15.4 %). Additional evaluation, using the amended software on 287 aerobic blood culture bottles, resulted in an acceptable mean deviation of −0.3 mL (−3.3 %). The new software version was also tested on 200 of the recently introduced plastic bottles, which will replace the glass bottles in the near future, showing a mean deviation of +2.8 mL (+26.7 %). In conclusion, the mean calculated volumes can be used for the training of a single phlebotomist. However, filling problems appear to be masked when using them for phlebotomist groups or on wards. Here, visual interpretation of boxplots and histograms can serve as a useful tool to observe the spread of the filling degrees and to develop a continuous improvement program. Re-adjustment of the software has proven to be necessary for use with plastic bottles. Due to our findings, BD has developed further adjustments to the software for validated use with plastic bottles, which will be released soon.
Literature
1.
go back to reference Rodríguez-Créixems M, Alcalá L, Muñoz P, Cercenado E, Vicente T, Bouza E (2008) Bloodstream infections: evolution and trends in the microbiology workload, incidence, and etiology, 1985–2006. Medicine (Baltimore) 87:234–249CrossRef Rodríguez-Créixems M, Alcalá L, Muñoz P, Cercenado E, Vicente T, Bouza E (2008) Bloodstream infections: evolution and trends in the microbiology workload, incidence, and etiology, 1985–2006. Medicine (Baltimore) 87:234–249CrossRef
2.
go back to reference Engel C, Brunkhorst FM, Bone HG, Brunkhorst R, Gerlach H, Grond S, Gruendling M, Huhle G, Jaschinski U, John S, Mayer K, Oppert M, Olthoff D, Quintel M, Ragaller M, Rossaint R, Stuber F, Weiler N, Welte T, Bogatsch H, Hartog C, Loeffler M, Reinhart K (2007) Epidemiology of sepsis in Germany: results from a national prospective multicenter study. Intensive Care Med 33:606–618 Engel C, Brunkhorst FM, Bone HG, Brunkhorst R, Gerlach H, Grond S, Gruendling M, Huhle G, Jaschinski U, John S, Mayer K, Oppert M, Olthoff D, Quintel M, Ragaller M, Rossaint R, Stuber F, Weiler N, Welte T, Bogatsch H, Hartog C, Loeffler M, Reinhart K (2007) Epidemiology of sepsis in Germany: results from a national prospective multicenter study. Intensive Care Med 33:606–618
3.
go back to reference Suetens C (2008) Surveillance of nosocomial bloodstream infections in Belgian hospitals: results from the national surveillance network, 1992–2004 and 2007 (preliminary). Scientific Institute of Public Health, Brussels Suetens C (2008) Surveillance of nosocomial bloodstream infections in Belgian hospitals: results from the national surveillance network, 1992–2004 and 2007 (preliminary). Scientific Institute of Public Health, Brussels
4.
go back to reference York MK, Henry M, Gilligan P (2010) Section 3.4.1. Aerobic bacteriology, blood cultures, general detection and interpretation. In: Isenberg HD (ed) Clinical microbiology procedures handbook. American Society of Microbiology (ASM) Press, Washington, DC York MK, Henry M, Gilligan P (2010) Section 3.4.1. Aerobic bacteriology, blood cultures, general detection and interpretation. In: Isenberg HD (ed) Clinical microbiology procedures handbook. American Society of Microbiology (ASM) Press, Washington, DC
5.
go back to reference Riedel S, Carroll KC (2010) Blood cultures: key elements for best practices and future directions. J Infect Chemother 16:301–316PubMedCrossRef Riedel S, Carroll KC (2010) Blood cultures: key elements for best practices and future directions. J Infect Chemother 16:301–316PubMedCrossRef
6.
go back to reference Willems E, Smismans A, Cartuyvels R, Coppens G, Van Vaerenbergh K, Van den Abeele AM, Frans J; Bilulu Study Group (2012) The preanalytical optimization of blood cultures: a review and the clinical importance of benchmarking in 5 Belgian hospitals. Diagn Microbiol Infect Dis 73:1–8PubMedCrossRef Willems E, Smismans A, Cartuyvels R, Coppens G, Van Vaerenbergh K, Van den Abeele AM, Frans J; Bilulu Study Group (2012) The preanalytical optimization of blood cultures: a review and the clinical importance of benchmarking in 5 Belgian hospitals. Diagn Microbiol Infect Dis 73:1–8PubMedCrossRef
7.
go back to reference Bouza E, Sousa D, Rodríguez-Créixems M, Lechuz JG, Muñoz P (2007) Is the volume of blood cultured still a significant factor in the diagnosis of bloodstream infections? J Clin Microbiol 45:2765–2769 Bouza E, Sousa D, Rodríguez-Créixems M, Lechuz JG, Muñoz P (2007) Is the volume of blood cultured still a significant factor in the diagnosis of bloodstream infections? J Clin Microbiol 45:2765–2769
8.
go back to reference Cockerill FR 3rd, Wilson JW, Vetter EA, Goodman KM, Torgerson CA, Harmsen WS, Schleck CD, Ilstrup DM, Washington JA 2nd, Wilson WR (2004) Optimal testing parameters for blood cultures. Clin Infect Dis 38:1724–1730PubMedCrossRef Cockerill FR 3rd, Wilson JW, Vetter EA, Goodman KM, Torgerson CA, Harmsen WS, Schleck CD, Ilstrup DM, Washington JA 2nd, Wilson WR (2004) Optimal testing parameters for blood cultures. Clin Infect Dis 38:1724–1730PubMedCrossRef
9.
go back to reference Clinical and Laboratory Standards Institute (CLSI) (2007) Principles and procedures for blood cultures; Approved guideline. CLSI document M47-A. CLSI, Wayne, PA, pp 1–53 Clinical and Laboratory Standards Institute (CLSI) (2007) Principles and procedures for blood cultures; Approved guideline. CLSI document M47-A. CLSI, Wayne, PA, pp 1–53
10.
go back to reference Cohen J, Brun-Buisson C, Torres A, Jorgensen J (2004) Diagnosis of infection in sepsis: an evidence-based review. Crit Care Med 32:S466–S494PubMedCrossRef Cohen J, Brun-Buisson C, Torres A, Jorgensen J (2004) Diagnosis of infection in sepsis: an evidence-based review. Crit Care Med 32:S466–S494PubMedCrossRef
11.
go back to reference Lassmann B, Gustafson DR, Wood CM, Rosenblatt JE (2007) Reemergence of anaerobic bacteremia. Clin Infect Dis 44:895–900PubMedCrossRef Lassmann B, Gustafson DR, Wood CM, Rosenblatt JE (2007) Reemergence of anaerobic bacteremia. Clin Infect Dis 44:895–900PubMedCrossRef
12.
go back to reference Hecht DW (2006) Anaerobes: antibiotic resistance, clinical significance, and the role of susceptibility testing. Anaerobe 12:115–121PubMedCrossRef Hecht DW (2006) Anaerobes: antibiotic resistance, clinical significance, and the role of susceptibility testing. Anaerobe 12:115–121PubMedCrossRef
13.
go back to reference Bannister ER, Woods GL (1995) Evaluation of routine anaerobic blood cultures in the BacT/Alert blood culture system. Am J Clin Pathol 104:279–282PubMed Bannister ER, Woods GL (1995) Evaluation of routine anaerobic blood cultures in the BacT/Alert blood culture system. Am J Clin Pathol 104:279–282PubMed
14.
go back to reference Horvath LL, George BJ, Hospenthal DR (2007) Detection of fifteen species of Candida in an automated blood culture system. J Clin Microbiol 45:3062–3064PubMedCentralPubMedCrossRef Horvath LL, George BJ, Hospenthal DR (2007) Detection of fifteen species of Candida in an automated blood culture system. J Clin Microbiol 45:3062–3064PubMedCentralPubMedCrossRef
15.
go back to reference Morris AJ, Wilson ML, Mirrett S, Reller LB (1993) Rationale for selective use of anaerobic blood cultures. J Clin Microbiol 31:2110–2113PubMedCentralPubMed Morris AJ, Wilson ML, Mirrett S, Reller LB (1993) Rationale for selective use of anaerobic blood cultures. J Clin Microbiol 31:2110–2113PubMedCentralPubMed
16.
go back to reference Miller JM (1998) A guide to specimen management in clinical microbiology, 2nd edn. American Society of Microbiology (ASM) Press, Washington, DC Miller JM (1998) A guide to specimen management in clinical microbiology, 2nd edn. American Society of Microbiology (ASM) Press, Washington, DC
17.
go back to reference Thompson RB Jr, Miller JM (2007) Specimen collection, transport and processing: bacteriology. In: Murray PR, Baron EJ (eds) Manual of clinical microbiology, 9th edn. American Society of Microbiology (ASM) Press, Washington, DC, pp 291–310 Thompson RB Jr, Miller JM (2007) Specimen collection, transport and processing: bacteriology. In: Murray PR, Baron EJ (eds) Manual of clinical microbiology, 9th edn. American Society of Microbiology (ASM) Press, Washington, DC, pp 291–310
18.
go back to reference James PA, Al-Shafi KM (2000) Clinical value of anaerobic blood culture: a retrospective analysis of positive patient episodes. J Clin Pathol 53:231–233PubMedCentralPubMedCrossRef James PA, Al-Shafi KM (2000) Clinical value of anaerobic blood culture: a retrospective analysis of positive patient episodes. J Clin Pathol 53:231–233PubMedCentralPubMedCrossRef
19.
20.
go back to reference Wilson ML, Harrell LJ, Mirrett S, Weinstein MP, Stratton CW, Reller LB (1992) Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles. J Clin Microbiol 30:63–66PubMedCentralPubMed Wilson ML, Harrell LJ, Mirrett S, Weinstein MP, Stratton CW, Reller LB (1992) Controlled evaluation of BACTEC PLUS 27 and Roche Septi-Chek anaerobic blood culture bottles. J Clin Microbiol 30:63–66PubMedCentralPubMed
21.
go back to reference Weinstein MP, Mirrett S, Wilson ML, Reimer LG, Reller LB (1994) Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles. J Clin Microbiol 32:2103–2106PubMedCentralPubMed Weinstein MP, Mirrett S, Wilson ML, Reimer LG, Reller LB (1994) Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles. J Clin Microbiol 32:2103–2106PubMedCentralPubMed
22.
go back to reference Koontz FP, Flint KK, Reynolds JK, Allen SD (1991) Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system. Diagn Microbiol Infect Dis 14:111–118PubMedCrossRef Koontz FP, Flint KK, Reynolds JK, Allen SD (1991) Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system. Diagn Microbiol Infect Dis 14:111–118PubMedCrossRef
23.
go back to reference Weinstein MP, Mirrett S, Reimer LG, Wilson ML, Smith-Elekes S, Chuard CR, Joho KL, Reller LB (1995) Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol 33:978–981PubMedCentralPubMed Weinstein MP, Mirrett S, Reimer LG, Wilson ML, Smith-Elekes S, Chuard CR, Joho KL, Reller LB (1995) Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. J Clin Microbiol 33:978–981PubMedCentralPubMed
24.
25.
go back to reference Reimer LG, Wilson ML, Weinstein MP (1997) Update on detection of bacteremia and fungemia. Clin Microbiol Rev 10:444–465PubMedCentralPubMed Reimer LG, Wilson ML, Weinstein MP (1997) Update on detection of bacteremia and fungemia. Clin Microbiol Rev 10:444–465PubMedCentralPubMed
26.
go back to reference Jungkind DL, Thakur M, Dyke J (1989) Evidence for a second mechanism of action of resin in BACTEC NR 16A aerobic blood culture medium, abstr. C-225, p 430. In: Abstracts of the 89th Annual Meeting of the American Society for Microbiology 1989. American Society for Microbiology (ASM), Washington, DC Jungkind DL, Thakur M, Dyke J (1989) Evidence for a second mechanism of action of resin in BACTEC NR 16A aerobic blood culture medium, abstr. C-225, p 430. In: Abstracts of the 89th Annual Meeting of the American Society for Microbiology 1989. American Society for Microbiology (ASM), Washington, DC
Metadata
Title
Evaluation of the BD BACTEC FX blood volume monitoring system as a continuous quality improvement measure
Authors
L. Coorevits
A.-M. Van den Abeele
Publication date
01-07-2015
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Clinical Microbiology & Infectious Diseases / Issue 7/2015
Print ISSN: 0934-9723
Electronic ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-015-2373-2

Other articles of this Issue 7/2015

European Journal of Clinical Microbiology & Infectious Diseases 7/2015 Go to the issue
Live Webinar | 27-06-2024 | 18:00 (CEST)

Keynote webinar | Spotlight on medication adherence

Live: Thursday 27th June 2024, 18:00-19:30 (CEST)

WHO estimates that half of all patients worldwide are non-adherent to their prescribed medication. The consequences of poor adherence can be catastrophic, on both the individual and population level.

Join our expert panel to discover why you need to understand the drivers of non-adherence in your patients, and how you can optimize medication adherence in your clinics to drastically improve patient outcomes.

Prof. Kevin Dolgin
Prof. Florian Limbourg
Prof. Anoop Chauhan
Developed by: Springer Medicine
Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discusses last year's major advances in heart failure and cardiomyopathies.