Skip to main content
Top
Published in: Journal of Artificial Organs 1/2013

01-03-2013 | Case Report

Jarvik 2000 biventricular assist device conversion from old pin-shaped bearing pumps to new conical bearing pumps

Authors: Shunsuke Saito, Taichi Sakaguchi, Sigeru Miyagawa, Hiroyuki Nishi, Yasushi Yoshikawa, Satsuki Fukushima, Daisuke Yoshioka, Takayoshi Ueno, Toru Kuratani, Yoshiki Sawa

Published in: Journal of Artificial Organs | Issue 1/2013

Login to get access

Abstract

A patient with a Jarvik 2000 (Jarvik Heart, Inc., New York, NY) biventricular assist device had massive hemolysis and device insufficiency of the right ventricular assist device (RVAD) after the anticoagulation was temporarily reversed due to cerebral hemorrhage. After the patient’s condition was stabilized by bridge use of CentriMag (Levitronix LLC, Waltham, MA) for right ventricle support, the Jarvik 2000 pumps with pin-shaped bearings were exchanged with new conical bearing pumps. Examination of the removed pumps revealed tight thrombus formation around the pin-shaped bearings.
Literature
1.
go back to reference Frazier OH, Myers TJ, Gregoric ID, Khan T, Delgado R, Croitoru M, Miller K, Jarvik R, Westaby S. Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system. Circulation. 2002;105:2855–60.PubMedCrossRef Frazier OH, Myers TJ, Gregoric ID, Khan T, Delgado R, Croitoru M, Miller K, Jarvik R, Westaby S. Initial clinical experience with the Jarvik 2000 implantable axial-flow left ventricular assist system. Circulation. 2002;105:2855–60.PubMedCrossRef
2.
go back to reference Kilic A, Nolan T, Li T, Yankey GK, Prastein DJ, Cheng G, Jarvik R, Wu ZJ, Griffith BP. Early in vivo experience with the pediatric Jarvik 2000 heart. ASAIO J. 2007;53:374–8.PubMedCrossRef Kilic A, Nolan T, Li T, Yankey GK, Prastein DJ, Cheng G, Jarvik R, Wu ZJ, Griffith BP. Early in vivo experience with the pediatric Jarvik 2000 heart. ASAIO J. 2007;53:374–8.PubMedCrossRef
3.
go back to reference Gibber M, Wu ZJ, Chang W, Bianchi G, Hu J, Garcia J, Jarvik R, Griffith BP. In vivo experience of the child-size pediatric Jarvik 2000 heart: update. ASAIO J. 2010;56:369–76.PubMed Gibber M, Wu ZJ, Chang W, Bianchi G, Hu J, Garcia J, Jarvik R, Griffith BP. In vivo experience of the child-size pediatric Jarvik 2000 heart: update. ASAIO J. 2010;56:369–76.PubMed
4.
go back to reference Saito S, Sakaguchi T, Sawa Y. Clinical report of long-term support with dual Jarvik 2000 biventricular assist device. J Heart Lung Transplant. 2011;30:845–7.PubMedCrossRef Saito S, Sakaguchi T, Sawa Y. Clinical report of long-term support with dual Jarvik 2000 biventricular assist device. J Heart Lung Transplant. 2011;30:845–7.PubMedCrossRef
Metadata
Title
Jarvik 2000 biventricular assist device conversion from old pin-shaped bearing pumps to new conical bearing pumps
Authors
Shunsuke Saito
Taichi Sakaguchi
Sigeru Miyagawa
Hiroyuki Nishi
Yasushi Yoshikawa
Satsuki Fukushima
Daisuke Yoshioka
Takayoshi Ueno
Toru Kuratani
Yoshiki Sawa
Publication date
01-03-2013
Publisher
Springer Japan
Published in
Journal of Artificial Organs / Issue 1/2013
Print ISSN: 1434-7229
Electronic ISSN: 1619-0904
DOI
https://doi.org/10.1007/s10047-012-0669-x

Other articles of this Issue 1/2013

Journal of Artificial Organs 1/2013 Go to the issue