Skip to main content
Top
Published in: Hernia 1/2019

01-02-2019 | Original Article

Efficacy of robotic versus open transversus abdominis release in a porcine model

Authors: W. H. Tan, J. M. McAllister, J. A. Blatnik

Published in: Hernia | Issue 1/2019

Login to get access

Abstract

Purpose

Transversus abdominis muscle release (TAR) combines retromuscular mesh placement with posterior component separation and muscle release. TAR is usually an open technique for abdominal wall reconstruction; however, several centers have performed this operation robotically and claim better clinical outcomes when compared to open surgery. We sought to compare robotic versus open TAR utilizing a porcine model.

Methods

Animals were randomized to open versus robotic TAR with mesh placement, survived for 4 weeks, then underwent diagnostic laparoscopy to assess adhesive burden and adhesion tenacity. T-peel testing was utilized to assess mesh ingrowth. The primary outcome was adhesive burden; secondary outcomes included mesh incorporation, contraction, and operative time.

Results

Nine robotic and eight open TARs were performed. Mean operative time was significantly shorter for the open cases compared to robotic cases (88.6 ± 12.9 min versus 228.3 ± 46.2, p < 0.01). Operative time in the robotic arm of the study decreased over time, from 300 to 165 min. No difference was seen in the mean adhesion area between the two groups. Adhesion tenacity and mesh flatness were similar. The work required to peel the mesh off surrounding tissue was significantly higher in the open TAR than in the robotic TAR group: 52.6 ± 15.5 and 32.9 ± 10.6 mJ/cm2, respectively (p < 0.01).

Conclusions

There were no differences in adhesions between the robotic and open approaches, but greater mesh contraction and ingrowth was observed in the open TAR group. Though operative time was longer in the robotic group, time dropped by about 40% from the first case to the last.
Literature
1.
go back to reference Novitsky YW, Elliott HL, Orenstein SB, Rosen MJ (2012) Transversus abdominis muscle release: a novel approach to posterior component separation during complex abdominal wall reconstruction. Am J Surg 204:709–716CrossRefPubMed Novitsky YW, Elliott HL, Orenstein SB, Rosen MJ (2012) Transversus abdominis muscle release: a novel approach to posterior component separation during complex abdominal wall reconstruction. Am J Surg 204:709–716CrossRefPubMed
2.
go back to reference Novitsky YW, Fayezizadeh M, Majumder A, Neupane R, Elliott HL, Orenstein SB (2016) Outcomes of posterior component separation with transversus abdominis muscle release and synthetic mesh sublay reinforcement. Ann Surg 264:226–232CrossRefPubMed Novitsky YW, Fayezizadeh M, Majumder A, Neupane R, Elliott HL, Orenstein SB (2016) Outcomes of posterior component separation with transversus abdominis muscle release and synthetic mesh sublay reinforcement. Ann Surg 264:226–232CrossRefPubMed
3.
go back to reference Deeken CR, Matthews BD (2012) Comparison of contracture, adhesion, tissue ingrowth, and histologic response characteristics of permanent and absorbable barrier meshes in a porcine model of laparoscopic ventral hernia repair. Hernia J Hernias Abdom Wall Surg 16:69–76CrossRef Deeken CR, Matthews BD (2012) Comparison of contracture, adhesion, tissue ingrowth, and histologic response characteristics of permanent and absorbable barrier meshes in a porcine model of laparoscopic ventral hernia repair. Hernia J Hernias Abdom Wall Surg 16:69–76CrossRef
4.
go back to reference Lake SP, Ray S, Zihni AM, Thompson DM Jr, Gluckstein J, Deeken CR (2015) Pore size and pore shape—but not mesh density—alter the mechanical strength of tissue ingrowth and host tissue response to synthetic mesh materials in a porcine model of ventral hernia repair. J Mech Behav Biomed Mater 42:186–197CrossRefPubMed Lake SP, Ray S, Zihni AM, Thompson DM Jr, Gluckstein J, Deeken CR (2015) Pore size and pore shape—but not mesh density—alter the mechanical strength of tissue ingrowth and host tissue response to synthetic mesh materials in a porcine model of ventral hernia repair. J Mech Behav Biomed Mater 42:186–197CrossRefPubMed
5.
go back to reference Einarsson JI, Grazul-Bilska AT, Vonnahme KA (2011) Barbed vs standard suture: randomized single-blinded comparison of adhesion formation and ease of use in an animal model. J Minim Invasive Gynecol 18:716–719CrossRefPubMed Einarsson JI, Grazul-Bilska AT, Vonnahme KA (2011) Barbed vs standard suture: randomized single-blinded comparison of adhesion formation and ease of use in an animal model. J Minim Invasive Gynecol 18:716–719CrossRefPubMed
6.
go back to reference Api M, Cikman MS, Boza A, Rabus MB, Onenerk M, Aker FV (2015) Peritoneal closure over barbed suture to prevent adhesions: a randomized controlled trial in an animal model. J Minim Invasive Gynecol 22:619–625CrossRefPubMed Api M, Cikman MS, Boza A, Rabus MB, Onenerk M, Aker FV (2015) Peritoneal closure over barbed suture to prevent adhesions: a randomized controlled trial in an animal model. J Minim Invasive Gynecol 22:619–625CrossRefPubMed
7.
go back to reference Silvestre AC, de Mathia GB, Fagundes DJ, Medeiros LR, Rosa MI (2011) Shrinkage evaluation of heavyweight and lightweight polypropylene meshes in inguinal hernia repair: a randomized controlled trial. Hernia J Hernias Abdom Wall Surg 15:629–634CrossRef Silvestre AC, de Mathia GB, Fagundes DJ, Medeiros LR, Rosa MI (2011) Shrinkage evaluation of heavyweight and lightweight polypropylene meshes in inguinal hernia repair: a randomized controlled trial. Hernia J Hernias Abdom Wall Surg 15:629–634CrossRef
8.
go back to reference Rogmark P, Ekberg O, Montgomery A (2017) Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature. Hernia J Hernias Abdom Wall Surg 21:687–696CrossRef Rogmark P, Ekberg O, Montgomery A (2017) Long-term retromuscular and intraperitoneal mesh size changes within a randomized controlled trial on incisional hernia repair, including a review of the literature. Hernia J Hernias Abdom Wall Surg 21:687–696CrossRef
9.
go back to reference Beldi G, Wagner M, Bruegger LE, Kurmann A, Candinas D (2011) Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation. Surg Endosc 25:749–755CrossRefPubMed Beldi G, Wagner M, Bruegger LE, Kurmann A, Candinas D (2011) Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation. Surg Endosc 25:749–755CrossRefPubMed
10.
go back to reference Amid PK (1997) Classification of biomaterials and their related complications in abdominal wall hernia surgery. Hernia J Hernias Abdom Wall Surg 1:15–21CrossRef Amid PK (1997) Classification of biomaterials and their related complications in abdominal wall hernia surgery. Hernia J Hernias Abdom Wall Surg 1:15–21CrossRef
11.
go back to reference Pierce RA, Perrone JM, Nimeri A, Sexton JA, Walcutt J, Frisella MM, Matthews BD (2009) 120-day comparative analysis of adhesion grade and quantity, mesh contraction, and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Innov 16:46–54CrossRefPubMed Pierce RA, Perrone JM, Nimeri A, Sexton JA, Walcutt J, Frisella MM, Matthews BD (2009) 120-day comparative analysis of adhesion grade and quantity, mesh contraction, and tissue response to a novel omega-3 fatty acid bioabsorbable barrier macroporous mesh after intraperitoneal placement. Surg Innov 16:46–54CrossRefPubMed
12.
go back to reference Klinge U, Klosterhalfen B, Muller M, Ottinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969CrossRefPubMed Klinge U, Klosterhalfen B, Muller M, Ottinger AP, Schumpelick V (1998) Shrinking of polypropylene mesh in vivo: an experimental study in dogs. Eur J Surg 164:965–969CrossRefPubMed
13.
go back to reference Gonzalez R, Fugate K, McClusky D 3rd, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043CrossRefPubMed Gonzalez R, Fugate K, McClusky D 3rd, Ritter EM, Lederman A, Dillehay D, Smith CD, Ramshaw BJ (2005) Relationship between tissue ingrowth and mesh contraction. World J Surg 29:1038–1043CrossRefPubMed
14.
go back to reference Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11CrossRefPubMed Novitsky YW, Harrell AG, Cristiano JA, Paton BL, Norton HJ, Peindl RD, Kercher KW, Heniford BT (2007) Comparative evaluation of adhesion formation, strength of ingrowth, and textile properties of prosthetic meshes after long-term intra-abdominal implantation in a rabbit. J Surg Res 140:6–11CrossRefPubMed
15.
go back to reference Weyhe D, Cobb W, Lecuivre J, Alves A, Ladet S, Lomanto D, Bayon Y (2015) Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage—systematic analysis of key parameters of meshes in a novel minipig hernia model. Int J Surg (Lond Engl) 22:46–53CrossRef Weyhe D, Cobb W, Lecuivre J, Alves A, Ladet S, Lomanto D, Bayon Y (2015) Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage—systematic analysis of key parameters of meshes in a novel minipig hernia model. Int J Surg (Lond Engl) 22:46–53CrossRef
16.
go back to reference Mantoo S, Rigaud J, Naulet S, Lehur PA, Meurette G (2014) Standardized surgical technique and dedicated operating room environment can reduce the operative time during robotic-assisted surgery for pelvic floor disorders. J Robot Surg 8:7–12CrossRefPubMed Mantoo S, Rigaud J, Naulet S, Lehur PA, Meurette G (2014) Standardized surgical technique and dedicated operating room environment can reduce the operative time during robotic-assisted surgery for pelvic floor disorders. J Robot Surg 8:7–12CrossRefPubMed
18.
go back to reference Bittner JG, Alrefai S, Vy M, Mabe M, Del Prado PAR, Clingempeel NL (2018) Comparative analysis of open and robotic transversus abdominis release for ventral hernia repair. Surg Endosc 32:727–734CrossRefPubMed Bittner JG, Alrefai S, Vy M, Mabe M, Del Prado PAR, Clingempeel NL (2018) Comparative analysis of open and robotic transversus abdominis release for ventral hernia repair. Surg Endosc 32:727–734CrossRefPubMed
19.
go back to reference Martin-Del-Campo LA, Weltz AS, Belyansky I, Novitsky YW (2018) Comparative analysis of perioperative outcomes of robotic versus open transversus abdominis release. Surg Endosc 32:840–845CrossRefPubMed Martin-Del-Campo LA, Weltz AS, Belyansky I, Novitsky YW (2018) Comparative analysis of perioperative outcomes of robotic versus open transversus abdominis release. Surg Endosc 32:840–845CrossRefPubMed
Metadata
Title
Efficacy of robotic versus open transversus abdominis release in a porcine model
Authors
W. H. Tan
J. M. McAllister
J. A. Blatnik
Publication date
01-02-2019
Publisher
Springer Paris
Published in
Hernia / Issue 1/2019
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-018-1836-7

Other articles of this Issue 1/2019

Hernia 1/2019 Go to the issue