Skip to main content
Top
Published in: Hernia 6/2008

01-12-2008 | Original Article

Influence of mesh materials on the integrity of the vas deferens following Lichtenstein hernioplasty: an experimental model

Authors: K. Junge, M. Binnebösel, R. Rosch, A. Öttinger, M. Stumpf, G. Mühlenbruch, V. Schumpelick, U. Klinge

Published in: Hernia | Issue 6/2008

Login to get access

Abstract

Background

The utilization of mesh reinforcement of the inguinal area with polypropylene mesh has increased drastically over the last decade. Infertility due to obstructive azoospermia is a rare but serious complication following inguinal hernia repair, especially in young patients. The aim of this study was to evaluate the effect of different mesh structures on integrity of the vas deferens.

Materials and methods

Twenty male Chinchilla rabbits were used. The spermatic cord was dissected free and a Lichtenstein repair was performed with a low-weight polypropylene mesh (UltraPro®) and a heavy-weight polypropylene mesh (Prolene®) on the contralateral side. A vasography was performed after six months in order to investigate obstructions of the vas deferens. Light microscopy of the mesh host tissue interface was also performed and the foreign body reaction analyzed. Spermatogenesis was evaluated using the Johnsen score.

Results

Vasography revealed relevant obstructions (>75% of lumen diameter) located at the mesh margins (50% of Prolene® and 22.2% of UltraPro® mesh samples). Microscopic investigation of the mesh–host tissue interface showed typical formation of foreign body granulomas. The diameters of the foreign body granulomas were significantly reduced in the UltraPro® mesh group (41.7 ± 5.5 μm) compared to the Prolene® mesh group (48.7 ± 7.7 μm). Upon investigating the percentages of apoptotic (TUNEL) and proliferating (Ki67) cells, no significant differences were found. Following Prolene® mesh implantation, a mean Johnsen score of 9.1 ± 1.2 was estimated, which was not significantly different from the UltraPro® mesh samples (8.9 ± 1.4, P > 0.05).

Conclusions

If a mesh material is needed for inguinal hernia repair in young patients, the use of modern low-weight large porous and elastic samples appears to have a beneficial effect on integrity of the vas deferens.
Literature
1.
go back to reference Rutkow IM, Robbins AW (1993) Demographic, classificatory, and socioeconomic aspects of hernia repair in the United States. Surg Clin North Am 73:413–426PubMed Rutkow IM, Robbins AW (1993) Demographic, classificatory, and socioeconomic aspects of hernia repair in the United States. Surg Clin North Am 73:413–426PubMed
2.
go back to reference Peiper C, Klinge U, Junge K, Schumpelick V (2002) Meshes in inguinal hernia repair. Zentralbl Chir 127:573–577PubMedCrossRef Peiper C, Klinge U, Junge K, Schumpelick V (2002) Meshes in inguinal hernia repair. Zentralbl Chir 127:573–577PubMedCrossRef
3.
go back to reference Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246PubMedCrossRef Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair. Biomaterials 19:2235–2246PubMedCrossRef
4.
go back to reference Junge K, Klinge U, Rosch R, Klosterhalfen B, Schumpelick V (2002) Functional and morphologic properties of a modified mesh for inguinal hernia repair. World J Surg 26:1472–1480PubMedCrossRef Junge K, Klinge U, Rosch R, Klosterhalfen B, Schumpelick V (2002) Functional and morphologic properties of a modified mesh for inguinal hernia repair. World J Surg 26:1472–1480PubMedCrossRef
5.
go back to reference Junge K, Klinge U, Prescher A, Giboni P, Niewiera M, Schumpelick V (2001) Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 5:113–118PubMedCrossRef Junge K, Klinge U, Prescher A, Giboni P, Niewiera M, Schumpelick V (2001) Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 5:113–118PubMedCrossRef
6.
go back to reference Klinge U, Klosterhalfen B, Conze J, Limberg W, Obolenski B, Ottinger AP et al (1998) Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall. Eur J Surg 164:951–960PubMedCrossRef Klinge U, Klosterhalfen B, Conze J, Limberg W, Obolenski B, Ottinger AP et al (1998) Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall. Eur J Surg 164:951–960PubMedCrossRef
7.
go back to reference Bringman S, Wollert S, Osterberg J, Smedberg S, Granlund H, Heikkinen TJ (2006) Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia. Br J Surg 93:1056–1059PubMedCrossRef Bringman S, Wollert S, Osterberg J, Smedberg S, Granlund H, Heikkinen TJ (2006) Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia. Br J Surg 93:1056–1059PubMedCrossRef
8.
go back to reference O’dwyer PJ, Kingsnorth AN, Molloy RG, Small PK, Lammers B, Horeyseck G (2005) Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92:166–170PubMedCrossRef O’dwyer PJ, Kingsnorth AN, Molloy RG, Small PK, Lammers B, Horeyseck G (2005) Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92:166–170PubMedCrossRef
9.
go back to reference Horstmann R, Hellwig M, Classen C, Rottgermann S, Palmes D (2006) Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes. World J Surg 30:1742–1749PubMedCrossRef Horstmann R, Hellwig M, Classen C, Rottgermann S, Palmes D (2006) Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes. World J Surg 30:1742–1749PubMedCrossRef
10.
go back to reference Nienhuijs S, Staal E, Strobbe L, Rosman C, Groenewoud H, Bleichrodt R (2007) Chronic pain after mesh repair of inguinal hernia: a systematic review. Am J Surg 194:394–400PubMedCrossRef Nienhuijs S, Staal E, Strobbe L, Rosman C, Groenewoud H, Bleichrodt R (2007) Chronic pain after mesh repair of inguinal hernia: a systematic review. Am J Surg 194:394–400PubMedCrossRef
11.
go back to reference Johnson SG (1970) Testicular biopsy score count—a method for registration of spermatogenesis in human testes: normal values and results in 335 hypogonadal males. Hormones 1:2–25CrossRef Johnson SG (1970) Testicular biopsy score count—a method for registration of spermatogenesis in human testes: normal values and results in 335 hypogonadal males. Hormones 1:2–25CrossRef
12.
go back to reference Pollak R, Nyhus LM (1983) Complications of groin hernia repair. Surg Clin North Am 63:1363–1371PubMed Pollak R, Nyhus LM (1983) Complications of groin hernia repair. Surg Clin North Am 63:1363–1371PubMed
13.
go back to reference Shin D, Lipshultz LI, Goldstein M, Barme GA, Fuchs EF, Nagler HM, McCallum S, Niederberger C, Schoor R, Brugh V, Honig S (2005) Herniorrhaphy with polypropylene mesh causing inguinal vasal obstruction: a preventable cause of obstructive azoospermia. Ann Surg 241:553–558PubMedCrossRef Shin D, Lipshultz LI, Goldstein M, Barme GA, Fuchs EF, Nagler HM, McCallum S, Niederberger C, Schoor R, Brugh V, Honig S (2005) Herniorrhaphy with polypropylene mesh causing inguinal vasal obstruction: a preventable cause of obstructive azoospermia. Ann Surg 241:553–558PubMedCrossRef
14.
go back to reference Uzzo RG, Lemack GE, Morrissey KP, Goldstein M (1999) The effects of mesh bioprosthesis on the spermatic cord structures: a preliminary report in a canine model. J Urol 161:1344–1349PubMedCrossRef Uzzo RG, Lemack GE, Morrissey KP, Goldstein M (1999) The effects of mesh bioprosthesis on the spermatic cord structures: a preliminary report in a canine model. J Urol 161:1344–1349PubMedCrossRef
15.
go back to reference Goldenberg A, Matone J, Marcondes W, Herbella FA, Farah JF (2005) Comparative study of inflammatory response and adhesions formation after fixation of different meshes for inguinal hernia repair in rabbits. Acta Cir Bras 20:347–352PubMed Goldenberg A, Matone J, Marcondes W, Herbella FA, Farah JF (2005) Comparative study of inflammatory response and adhesions formation after fixation of different meshes for inguinal hernia repair in rabbits. Acta Cir Bras 20:347–352PubMed
16.
go back to reference Peiper C, Junge K, Klinge U, Strehlau E, Krones C, Ottinger A et al. (2005) The influence of inguinal mesh repair on the spermatic cord: a pilot study in the rabbit. J Invest Surg 18:273–278 Peiper C, Junge K, Klinge U, Strehlau E, Krones C, Ottinger A et al. (2005) The influence of inguinal mesh repair on the spermatic cord: a pilot study in the rabbit. J Invest Surg 18:273–278
17.
go back to reference Berndsen FH, Bjursten LM, Simanaitis M, Montgomery A (2004) Does mesh implantation affect the spermatic cord structures after inguinal hernia surgery? An experimental study in rats. Eur Surg Res 36:318–322PubMedCrossRef Berndsen FH, Bjursten LM, Simanaitis M, Montgomery A (2004) Does mesh implantation affect the spermatic cord structures after inguinal hernia surgery? An experimental study in rats. Eur Surg Res 36:318–322PubMedCrossRef
Metadata
Title
Influence of mesh materials on the integrity of the vas deferens following Lichtenstein hernioplasty: an experimental model
Authors
K. Junge
M. Binnebösel
R. Rosch
A. Öttinger
M. Stumpf
G. Mühlenbruch
V. Schumpelick
U. Klinge
Publication date
01-12-2008
Publisher
Springer-Verlag
Published in
Hernia / Issue 6/2008
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-008-0400-2

Other articles of this Issue 6/2008

Hernia 6/2008 Go to the issue