Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel®) vs. titanium tacks: a randomised controlled experimental study in pigs

Authors: J. R. Eriksen, J. I. Bech, D. Linnemann, J. Rosenberg

Published in: Hernia | Issue 5/2008

Login to get access

Abstract

Background

The main reason for hospital stay after laparoscopic ventral hernia repair (LVHR) is probably pain, which also causes a lengthening of the patient’s time to assume normal daily activities and work. It is likely that titanium tacks may be the main contributing factor to early (and maybe chronic) pain after LVHR. Therefore, non-invasive and patient-friendly mesh fixation methods must be considered. The present study was designed to investigate the technical applicability, safety and effect of Tisseel® for intraperitoneal mesh fixation.

Methods

Nine 40-kg Danish Landrace female pigs had two pieces of MotifMESH® and two pieces of Proceed® mesh fixed in the intraperitoneal position by a laparoscopic technique. The two pieces of the same mesh were fixed with fibrin glue (Tisseel) and titanium tacks, respectively. All pigs were euthanised on the 30th postoperative day and the mesh–tissue samples were tested for strength of ingrowth (peel test), adhesion formation, mesh shrinkage and examined for histological alterations.

Results

No meshes were displaced from their initial position at autopsy, but we observed two cases of mesh folding that could have resulted in hernia recurrence in real patients. There were no significant differences in the strength of ingrowth between different mesh types or fixation methods, measured as peel work per area of mesh (J/m2) and peak force per width of mesh (Nmax/cm). The Proceed mesh shrank by 11% compared to 4% for the MotifMESH mesh (p =  0.002). There was no difference in the grade of adhesions (%) between fixation methods (p = 0.794) or different mesh types (p = 0.296). In the same fashion, there was no difference in the strength of adhesions (grades 0–4) between the two fixation methods or different mesh types (p>0.5, χ2 test). There was no significant difference in the formation of fibrosis or inflammation between the different meshes or fixation methods. All samples showed significant foreign-body reaction with giant cells.

Conclusion

Our results suggest that the laparoscopic fixation of an intraperitoneal mesh with Tisseel is safe and technically feasible in a pig model. There is still no evidence that fibrin-sealing alone is appropriate for intraperitoneal mesh fixation in hernia repair, but the technique might become an alternative or supplement to mechanical mesh fixation. Until then, further experimental research in animal hernia models with larger meshes is needed, especially with a focus on mesh folding and displacement.
Literature
1.
go back to reference Canonico S, Santoriello A, Campitiello F, Fattopace A, Corte AD, Sordelli I, Benevento R (2005) Mesh fixation with human fibrin glue (Tissucol) in open tension-free inguinal hernia repair: a preliminary report. Hernia 9:330–333PubMedCrossRef Canonico S, Santoriello A, Campitiello F, Fattopace A, Corte AD, Sordelli I, Benevento R (2005) Mesh fixation with human fibrin glue (Tissucol) in open tension-free inguinal hernia repair: a preliminary report. Hernia 9:330–333PubMedCrossRef
2.
go back to reference Lovisetto F, Zonta S, Rota E, Mazzilli M, Bardone M, Bottero L, Faillace G, Longoni M (2007) Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty: a prospective, randomized study. Ann Surg 245:222–231PubMedCrossRef Lovisetto F, Zonta S, Rota E, Mazzilli M, Bardone M, Bottero L, Faillace G, Longoni M (2007) Use of human fibrin glue (Tissucol) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty: a prospective, randomized study. Ann Surg 245:222–231PubMedCrossRef
3.
go back to reference Lau H (2005) Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial. Ann Surg 242:670–675PubMedCrossRef Lau H (2005) Fibrin sealant versus mechanical stapling for mesh fixation during endoscopic extraperitoneal inguinal hernioplasty: a randomized prospective trial. Ann Surg 242:670–675PubMedCrossRef
4.
go back to reference Olmi S, Erba L, Bertolini A, Scaini A, Croce E (2006) Fibrin glue for mesh fixation in laparoscopic transabdominal preperitoneal (TAPP) hernia repair: indications, technique, and outcomes. Surg Endosc 20:1846–1850PubMedCrossRef Olmi S, Erba L, Bertolini A, Scaini A, Croce E (2006) Fibrin glue for mesh fixation in laparoscopic transabdominal preperitoneal (TAPP) hernia repair: indications, technique, and outcomes. Surg Endosc 20:1846–1850PubMedCrossRef
5.
go back to reference Olmi S, Scaini A, Erba L, Bertolini A, Croce E (2007) Laparoscopic repair of inguinal hernias using an intraperitoneal onlay mesh technique and a Parietex composite mesh fixed with fibrin glue (Tissucol). Personal technique and preliminary results. Surg Endosc 21:1961–1964PubMedCrossRef Olmi S, Scaini A, Erba L, Bertolini A, Croce E (2007) Laparoscopic repair of inguinal hernias using an intraperitoneal onlay mesh technique and a Parietex composite mesh fixed with fibrin glue (Tissucol). Personal technique and preliminary results. Surg Endosc 21:1961–1964PubMedCrossRef
6.
go back to reference Olmi S, Scaini A, Erba L, Croce E (2007) Use of fibrin glue (Tissucol) in laparoscopic repair of abdominal wall defects: preliminary experience. Surg Endosc 21:409–413PubMedCrossRef Olmi S, Scaini A, Erba L, Croce E (2007) Use of fibrin glue (Tissucol) in laparoscopic repair of abdominal wall defects: preliminary experience. Surg Endosc 21:409–413PubMedCrossRef
7.
go back to reference Carbajo MA, Martín del Olmo JC, Blanco JI, de la Cuesta C, Toledano M, Martin F, Vaguero C, Inglada L (1999) Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh. Surg Endosc 13:250–252PubMedCrossRef Carbajo MA, Martín del Olmo JC, Blanco JI, de la Cuesta C, Toledano M, Martin F, Vaguero C, Inglada L (1999) Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh. Surg Endosc 13:250–252PubMedCrossRef
8.
go back to reference Misra MC, Bansal VK, Kulkarni MP, Pawar DK (2006) Comparison of laparoscopic and open repair of incisional and primary ventral hernia: results of a prospective randomized study. Surg Endosc 20:1839–1845PubMedCrossRef Misra MC, Bansal VK, Kulkarni MP, Pawar DK (2006) Comparison of laparoscopic and open repair of incisional and primary ventral hernia: results of a prospective randomized study. Surg Endosc 20:1839–1845PubMedCrossRef
9.
go back to reference Barbaros U, Asoglu O, Seven R, Erbil Y, Dinccag A, Deveci U, Ozarmagan S, Mercan S (2007) The comparison of laparoscopic and open ventral hernia repairs: a prospective randomized study. Hernia 11:51–56PubMedCrossRef Barbaros U, Asoglu O, Seven R, Erbil Y, Dinccag A, Deveci U, Ozarmagan S, Mercan S (2007) The comparison of laparoscopic and open ventral hernia repairs: a prospective randomized study. Hernia 11:51–56PubMedCrossRef
10.
go back to reference Olmi S, Scaini A, Cesana GC, Erba L, Croce E (2007) Laparoscopic versus open incisional hernia repair: an open randomized controlled study. Surg Endosc 21:555–559PubMedCrossRef Olmi S, Scaini A, Cesana GC, Erba L, Croce E (2007) Laparoscopic versus open incisional hernia repair: an open randomized controlled study. Surg Endosc 21:555–559PubMedCrossRef
11.
go back to reference Voskerician G, Gingras PH, Anderson JM (2006) Macroporous condensed poly(tetrafluoroethylene). I. In vivo inflammatory response and healing characteristics. J Biomed Mater Res A 76:234–242PubMed Voskerician G, Gingras PH, Anderson JM (2006) Macroporous condensed poly(tetrafluoroethylene). I. In vivo inflammatory response and healing characteristics. J Biomed Mater Res A 76:234–242PubMed
12.
go back to reference Voskerician G, Rodriguez A, Gingras PH (2007) Macroporous condensed poly(tetra fluoro-ethylene). II. In vivo effect on adhesion formation and tissue integration. J Biomed Mater Res A 82:426–435PubMed Voskerician G, Rodriguez A, Gingras PH (2007) Macroporous condensed poly(tetra fluoro-ethylene). II. In vivo effect on adhesion formation and tissue integration. J Biomed Mater Res A 82:426–435PubMed
13.
go back to reference Lanzafame RJ, Stadler I, Brondon P, Soltz BA, Devore DP (2005) Preliminary assessment of postoperative adhesion formation after laser-assisted mesh fixation to the peritoneal surface. J Laparosc Adv Surg Tech A 15:105–111CrossRef Lanzafame RJ, Stadler I, Brondon P, Soltz BA, Devore DP (2005) Preliminary assessment of postoperative adhesion formation after laser-assisted mesh fixation to the peritoneal surface. J Laparosc Adv Surg Tech A 15:105–111CrossRef
14.
go back to reference Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef Katkhouda N, Mavor E, Friedlander MH, Mason RJ, Kiyabu M, Grant SW, Achanta K, Kirkman EL, Narayanan K, Essani R (2001) Use of fibrin sealant for prosthetic mesh fixation in laparoscopic extraperitoneal inguinal hernia repair. Ann Surg 233:18–25PubMedCrossRef
15.
go back to reference Schulze S, Kristiansen VB, Hansen BF, Rosenberg J (2005) Biological tissue adhesive for mesh-application in pigs: an experimental study. Surg Endosc 19:342–344PubMedCrossRef Schulze S, Kristiansen VB, Hansen BF, Rosenberg J (2005) Biological tissue adhesive for mesh-application in pigs: an experimental study. Surg Endosc 19:342–344PubMedCrossRef
16.
go back to reference Fortelny RH, Petter-Puchner AH, Walder N, Mittermayr R, Ohlinger W, Heinze A, Redl H (2007) Cyanoacrylate tissue sealant impairs tissue integration of macroporous mesh in experimental hernia repair. Surg Endosc 21:1781–1785PubMedCrossRef Fortelny RH, Petter-Puchner AH, Walder N, Mittermayr R, Ohlinger W, Heinze A, Redl H (2007) Cyanoacrylate tissue sealant impairs tissue integration of macroporous mesh in experimental hernia repair. Surg Endosc 21:1781–1785PubMedCrossRef
17.
go back to reference Petter-Puchner AH, Fortelny R, Mittermayr R, Ohlinger W, Redl H (2005) Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat. Hernia 9:322–329PubMedCrossRef Petter-Puchner AH, Fortelny R, Mittermayr R, Ohlinger W, Redl H (2005) Fibrin sealing versus stapling of hernia meshes in an onlay model in the rat. Hernia 9:322–329PubMedCrossRef
18.
go back to reference McGinty JJ, Hogle NJ, McCarthy H, Fowler DL (2005) A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh. Surg Endosc 19:786–790PubMedCrossRef McGinty JJ, Hogle NJ, McCarthy H, Fowler DL (2005) A comparative study of adhesion formation and abdominal wall ingrowth after laparoscopic ventral hernia repair in a porcine model using multiple types of mesh. Surg Endosc 19:786–790PubMedCrossRef
19.
go back to reference Majercik S, Tsikitis V, Iannitti DA (2006) Strength of tissue attachment to mesh after ventral hernia repair with synthetic composite mesh in a porcine model. Surg Endosc 20:1671–1674PubMedCrossRef Majercik S, Tsikitis V, Iannitti DA (2006) Strength of tissue attachment to mesh after ventral hernia repair with synthetic composite mesh in a porcine model. Surg Endosc 20:1671–1674PubMedCrossRef
20.
go back to reference Eriksen JR, Gögenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11:481–492PubMedCrossRef Eriksen JR, Gögenur I, Rosenberg J (2007) Choice of mesh for laparoscopic ventral hernia repair. Hernia 11:481–492PubMedCrossRef
21.
go back to reference Toosie K, Gallego K, Stabile BE, Schaber B, French S, de Virgilio C (2000) Fibrin glue reduces intra-abdominal adhesions to synthetic mesh in a rat ventral hernia model. Am Surg 66:41–45PubMed Toosie K, Gallego K, Stabile BE, Schaber B, French S, de Virgilio C (2000) Fibrin glue reduces intra-abdominal adhesions to synthetic mesh in a rat ventral hernia model. Am Surg 66:41–45PubMed
22.
go back to reference de Virgilio C, Elbassir M, Hidalgo A, Schaber B, French S, Amin S, Stabile BE (1999) Fibrin glue reduces the severity of intra-abdominal adhesions in a rat model. Am J Surg 178:577–580PubMedCrossRef de Virgilio C, Elbassir M, Hidalgo A, Schaber B, French S, Amin S, Stabile BE (1999) Fibrin glue reduces the severity of intra-abdominal adhesions in a rat model. Am J Surg 178:577–580PubMedCrossRef
Metadata
Title
Laparoscopic intraperitoneal mesh fixation with fibrin sealant (Tisseel®) vs. titanium tacks: a randomised controlled experimental study in pigs
Authors
J. R. Eriksen
J. I. Bech
D. Linnemann
J. Rosenberg
Publication date
01-10-2008
Publisher
Springer-Verlag
Published in
Hernia / Issue 5/2008
Print ISSN: 1265-4906
Electronic ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-008-0375-z

Other articles of this Issue 5/2008

Hernia 5/2008 Go to the issue