Skip to main content
Top
Published in: Clinical Oral Investigations 8/2016

01-11-2016 | Original Article

Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis

Authors: Frank Engelhardt, Sebastian Hahnel, Verena Preis, Martin Rosentritt

Published in: Clinical Oral Investigations | Issue 8/2016

Login to get access

Abstract

Objectives

Flowable bulk-fill resin bonded composites (RBCs) are supposed to show improved abrasion resistance and fracture toughness in comparison to flowable conventional RBCs.

Materials and methods

Specimens of eight flowable RBCs (5× flowable conventional, 3× flowable bulk-fill) were fabricated for testing relative fracture toughness (SENB), relative three-body wear, the Vickers hardness, glass transition Tg (differential scanning calorimetry; DSC) and filler mass fraction (thermal gravimetric analysis; TGA). A laboratory veneering composite was used as a reference. Fracture toughness and wear values were related to this reference. Scanning electron microscope images were evaluated for fraktographical and microstructural investigations. Statistical analyses were performed using one-way Anova, the Bonferroni post hoc test and the Pearson correlation test (α =0.05).

Results

Relative fracture toughness varied between 0.64 and 1.34 (1.00 = 1.69 MPam½) and relative wear rates between 1.24 and 0.55 (1.00 = 134 μm). The Vickers hardness ranged between 14.4 and 57.2 HV. TGA showed filler fractions between 55 and 77 wt.%. Tg values varied between −67.8 and −40.9 °C. None of the tests identified clear differences between flowable bulk-fills or conventional flowable RBCs. The Pearson correlation coefficient (cc) showed significant correlations (cc > 0.583; p < 0.001) between relative fracture toughness and hardness or filler content. There was a significant correlation (cc = 0.757; p = 0.005) between relative wear and glass transition temperature or between filler fraction and the Vickers hardness (cc > 0.702; p < 0.001). For all filler sizes breakdown was found, where clusters and pre-polymerized particles were partly disintegrated.

Conclusions

Flowable bulk-fill RBCs showed no improved abrasion resistance and fracture toughness in comparison to flowable conventional RBCs.

Clinical relevance

Differences in the properties were higher between the individual materials than between the material groups. Therefore the appropriate material selection may be essential for a clinical success.
Literature
1.
go back to reference Sunnegårdh-Grönberg K, van Dijken JWV, Funegårdh U, Lindberg A, Nilsson M (2009) Selection of dental materials and longevity of replaced restorations in public dental health clinics in northern Sweden. J Dent 37:673–678CrossRefPubMed Sunnegårdh-Grönberg K, van Dijken JWV, Funegårdh U, Lindberg A, Nilsson M (2009) Selection of dental materials and longevity of replaced restorations in public dental health clinics in northern Sweden. J Dent 37:673–678CrossRefPubMed
2.
go back to reference Ilie N, Stark K (2014) Curing behaviour of high-viscosity bulk-fill composites. J Dent 42:977–985CrossRefPubMed Ilie N, Stark K (2014) Curing behaviour of high-viscosity bulk-fill composites. J Dent 42:977–985CrossRefPubMed
3.
go back to reference Bucuta S, Ilie N (2014) Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Invest 18:1991–2000CrossRef Bucuta S, Ilie N (2014) Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clin Oral Invest 18:1991–2000CrossRef
4.
go back to reference Price RB, Dérand T, Sedarous M, Andreou P, Loney RW (2000) Effect of distance on the power density from two light guides. J Esthet Dent 12:320–327CrossRefPubMed Price RB, Dérand T, Sedarous M, Andreou P, Loney RW (2000) Effect of distance on the power density from two light guides. J Esthet Dent 12:320–327CrossRefPubMed
5.
go back to reference Lohbauer U, Rahiotis C, Krämer N, Petschelt A, Eliades G (2005) The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite. Dent Mater 21:608–615CrossRefPubMed Lohbauer U, Rahiotis C, Krämer N, Petschelt A, Eliades G (2005) The effect of different light-curing units on fatigue behavior and degree of conversion of a resin composite. Dent Mater 21:608–615CrossRefPubMed
6.
go back to reference Lohbauer U, Belli R, Ferracane JL (2013) Factors involved in mechanical fatigue degradation of dental resin composites. J Dent Res 92:584–591CrossRefPubMed Lohbauer U, Belli R, Ferracane JL (2013) Factors involved in mechanical fatigue degradation of dental resin composites. J Dent Res 92:584–591CrossRefPubMed
7.
go back to reference Rencz A, Hickel R (2012) Curing efficiency of modern LED units. Clin Oral Invest 16:173–179CrossRef Rencz A, Hickel R (2012) Curing efficiency of modern LED units. Clin Oral Invest 16:173–179CrossRef
8.
go back to reference Van Dijken J, Pallesen U (2014) A randomized controlled three year evaluation of “bulk-filled” posterior resin restorations based on stress decreasing resin technology. Dent Mater 30:245–251CrossRef Van Dijken J, Pallesen U (2014) A randomized controlled three year evaluation of “bulk-filled” posterior resin restorations based on stress decreasing resin technology. Dent Mater 30:245–251CrossRef
9.
go back to reference Da Rosa R, Cenci MS, Donassollo TA, Lognerico AD, Demarco FF (2006) A clinical evaluation of posterior restorations: 17 year findings. J Dent 34:427–435CrossRef Da Rosa R, Cenci MS, Donassollo TA, Lognerico AD, Demarco FF (2006) A clinical evaluation of posterior restorations: 17 year findings. J Dent 34:427–435CrossRef
10.
go back to reference Ferracane JL (2013) Resin-based composite performance: are there some things we can’t predict? Dent Mater 29:51–58CrossRefPubMed Ferracane JL (2013) Resin-based composite performance: are there some things we can’t predict? Dent Mater 29:51–58CrossRefPubMed
11.
go back to reference Bayne SC (2012) Review: correlation of clinical performance with ‘in vitro tests’ of restorative dental materials that use polymer-based matrices. Dent Mater 28:52–71CrossRefPubMed Bayne SC (2012) Review: correlation of clinical performance with ‘in vitro tests’ of restorative dental materials that use polymer-based matrices. Dent Mater 28:52–71CrossRefPubMed
12.
go back to reference Ferracane JL (2006) Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater 22:211–222CrossRefPubMed Ferracane JL (2006) Hygroscopic and hydrolytic effects in dental polymer networks. Dent Mater 22:211–222CrossRefPubMed
13.
go back to reference Czasch P, Ilie N (2013) In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Invest 17:227–235CrossRef Czasch P, Ilie N (2013) In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clin Oral Invest 17:227–235CrossRef
14.
go back to reference Ilie N, Bucuta S, Draenert M (2013) Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 38:618–625CrossRefPubMed Ilie N, Bucuta S, Draenert M (2013) Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Oper Dent 38:618–625CrossRefPubMed
15.
go back to reference Ilie N, Rencz A, Hickel R (2013) Investigations towards nano-hybrid resin-based composites. Clin Oral Invest 17:185–193CrossRef Ilie N, Rencz A, Hickel R (2013) Investigations towards nano-hybrid resin-based composites. Clin Oral Invest 17:185–193CrossRef
16.
go back to reference Roulet JF, Price R (2014) Light curing—guidelines for practitioners—a consensus statement from the 2014 symposium on light curing in dentistry. Held at Dalhousie University, Halifax, Canada. J Adhes Dent 16:303–304PubMed Roulet JF, Price R (2014) Light curing—guidelines for practitioners—a consensus statement from the 2014 symposium on light curing in dentistry. Held at Dalhousie University, Halifax, Canada. J Adhes Dent 16:303–304PubMed
17.
go back to reference De Gee A, Pallav P, Davidson C (1986) Effect of abrasion medium on wear of stress-bearing composites and amalgam in vitro. J Dent Res 65:654–658CrossRefPubMed De Gee A, Pallav P, Davidson C (1986) Effect of abrasion medium on wear of stress-bearing composites and amalgam in vitro. J Dent Res 65:654–658CrossRefPubMed
18.
go back to reference De Gee A, Pallav P (1994) Occlusal wear simulation with the ACTA wear machine. J Dent 22:21–27CrossRef De Gee A, Pallav P (1994) Occlusal wear simulation with the ACTA wear machine. J Dent 22:21–27CrossRef
19.
go back to reference ISO 6507: 2005–12 Metallic materials—Vickers hardness test. Beuth Verlag. Berlin 2005 ISO 6507: 2005–12 Metallic materials—Vickers hardness test. Beuth Verlag. Berlin 2005
20.
go back to reference Manhart J, Kunzelmann K, Chen H, Hickel R (2000) Mechanical properties and wear behavior of light-cured packable composite resins. Dent Mater 16:33–40CrossRefPubMed Manhart J, Kunzelmann K, Chen H, Hickel R (2000) Mechanical properties and wear behavior of light-cured packable composite resins. Dent Mater 16:33–40CrossRefPubMed
21.
go back to reference Mesquita RV, Axmann D, Geis-Gerstorfer J (2006) Dynamic visco-elastic properties of dental composite resins. Dent Mater 22:258–267CrossRefPubMed Mesquita RV, Axmann D, Geis-Gerstorfer J (2006) Dynamic visco-elastic properties of dental composite resins. Dent Mater 22:258–267CrossRefPubMed
22.
go back to reference Belli R, Petschelt A, Lohbauer U (2014) Are linear elastic material properties relevant predictors of the cyclic fatigue resistance of dental resin composites? Dent Mater 30:381–391CrossRefPubMed Belli R, Petschelt A, Lohbauer U (2014) Are linear elastic material properties relevant predictors of the cyclic fatigue resistance of dental resin composites? Dent Mater 30:381–391CrossRefPubMed
23.
go back to reference Cock DJ, Watts DC (1985) Time-dependent deformation of composite restorative materials in compression. J Dent Res 64:147–150CrossRefPubMed Cock DJ, Watts DC (1985) Time-dependent deformation of composite restorative materials in compression. J Dent Res 64:147–150CrossRefPubMed
24.
go back to reference Sabbagh J, Vreven J, Leloup G (2002) Dynamic and static moduli of elasticity of resin-based materials. Dent Mater 18:64–71CrossRefPubMed Sabbagh J, Vreven J, Leloup G (2002) Dynamic and static moduli of elasticity of resin-based materials. Dent Mater 18:64–71CrossRefPubMed
25.
go back to reference Alshali RZ, Silikas N, Satterthwaite JD (2013) Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater 29:e213–e217CrossRefPubMed Alshali RZ, Silikas N, Satterthwaite JD (2013) Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals. Dent Mater 29:e213–e217CrossRefPubMed
26.
go back to reference El-Damanhoury H, Platt J (2014) Polymerization shrinkage stress kinetics and related properties of bulk-fill resin composites. Oper Dent 39:374–382CrossRefPubMed El-Damanhoury H, Platt J (2014) Polymerization shrinkage stress kinetics and related properties of bulk-fill resin composites. Oper Dent 39:374–382CrossRefPubMed
27.
go back to reference Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A (2012) Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials? Dent Mater 28:521–528CrossRefPubMed Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A (2012) Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials? Dent Mater 28:521–528CrossRefPubMed
28.
go back to reference Flury S, Peutzfeldt A, Lussi A (2014) Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites. Dent Mater 30:1104–1112CrossRefPubMed Flury S, Peutzfeldt A, Lussi A (2014) Influence of increment thickness on microhardness and dentin bond strength of bulk fill resin composites. Dent Mater 30:1104–1112CrossRefPubMed
29.
go back to reference Leprince J, Palin WM, Vanacker J, Sabbagh J, Devaux J, Leloup G (2014) Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent 42:993–1000CrossRefPubMed Leprince J, Palin WM, Vanacker J, Sabbagh J, Devaux J, Leloup G (2014) Physico-mechanical characteristics of commercially available bulk-fill composites. J Dent 42:993–1000CrossRefPubMed
30.
go back to reference Dickens S, Stansbury J, Choi K, Floyd C (2003) Photopolymerization kinetics of methacrylate dental resins. Macromolecules 36:6043–6053CrossRef Dickens S, Stansbury J, Choi K, Floyd C (2003) Photopolymerization kinetics of methacrylate dental resins. Macromolecules 36:6043–6053CrossRef
31.
go back to reference Sideridou I, Tserki V, Papanastasiou G (2002) Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 23:1819–1829CrossRefPubMed Sideridou I, Tserki V, Papanastasiou G (2002) Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 23:1819–1829CrossRefPubMed
32.
go back to reference Morgan DS, Kalachandra Shobha H, Gunduz N, Stejskal E (2000) Analysis of a dimethacrylate copolymer (Bis-GMA and TEGDMA) network by DSC and C solution and solid-state NMR spectroscopy. Biomaterials 21:1897–1903CrossRefPubMed Morgan DS, Kalachandra Shobha H, Gunduz N, Stejskal E (2000) Analysis of a dimethacrylate copolymer (Bis-GMA and TEGDMA) network by DSC and C solution and solid-state NMR spectroscopy. Biomaterials 21:1897–1903CrossRefPubMed
33.
go back to reference Barkmeier W, Takamizawa T, Erickson R, Tsujimoto A, Latta M, Miyazaki M (2015) Localized and generalized simulated wear of resin composites. Oper Dent 40–3:322–335CrossRef Barkmeier W, Takamizawa T, Erickson R, Tsujimoto A, Latta M, Miyazaki M (2015) Localized and generalized simulated wear of resin composites. Oper Dent 40–3:322–335CrossRef
34.
go back to reference Zorzin J, Maier E, Harre S, Fey T, Belli R, Lohbauer U, Petschelt A, Taschner M (2015) Bulk-fill resin composites: polymerization properties and extended light curing. Dent Mater 31:293–301CrossRefPubMed Zorzin J, Maier E, Harre S, Fey T, Belli R, Lohbauer U, Petschelt A, Taschner M (2015) Bulk-fill resin composites: polymerization properties and extended light curing. Dent Mater 31:293–301CrossRefPubMed
35.
go back to reference Bayne SC, Taylor D, Heymann H (1992) Protection hypothesis for composite wear. Dent Mater 8:305–309CrossRefPubMed Bayne SC, Taylor D, Heymann H (1992) Protection hypothesis for composite wear. Dent Mater 8:305–309CrossRefPubMed
36.
go back to reference Finlay N, Hahnel S, Dowling AH, Fleming G (2013) The in vitro wear behavior of experimental resin-based composites derived from a commercial formulation. Dent Mater 29:365–374CrossRefPubMed Finlay N, Hahnel S, Dowling AH, Fleming G (2013) The in vitro wear behavior of experimental resin-based composites derived from a commercial formulation. Dent Mater 29:365–374CrossRefPubMed
37.
go back to reference Beun S, Glorieux T, Devaux J, Vreven J, Leloup G (2007) Characterization of nanofilled compared to universal and microfilled composites. Dent Mater 23:51–59CrossRefPubMed Beun S, Glorieux T, Devaux J, Vreven J, Leloup G (2007) Characterization of nanofilled compared to universal and microfilled composites. Dent Mater 23:51–59CrossRefPubMed
38.
go back to reference Beun S, Bailly C, Devaux J, Leloup G (2012) Physical, mechanical and rheological characterization of resin-based pit and fissure sealants compared to flowable resin composites. Dent Mater 28:349–359CrossRefPubMed Beun S, Bailly C, Devaux J, Leloup G (2012) Physical, mechanical and rheological characterization of resin-based pit and fissure sealants compared to flowable resin composites. Dent Mater 28:349–359CrossRefPubMed
39.
go back to reference Leprince J, Palin WM, Mullier T, Devaux J, Vreven J, Leloup G (2010) Investigating filler morphology and mechanical properties of new low-shrinkage resin composite types. J Oral Rehabil 37:364–376CrossRefPubMed Leprince J, Palin WM, Mullier T, Devaux J, Vreven J, Leloup G (2010) Investigating filler morphology and mechanical properties of new low-shrinkage resin composite types. J Oral Rehabil 37:364–376CrossRefPubMed
40.
go back to reference Rastelli AN, Jacomassi DP, Faloni AP, Queiroz TP, Rojas SS, Bernardi MI, Bagnato VS, Hernandes AC (2012) The filler content of the dental composite resins and their influence on different properties. Microsc Res Tech 75:758–765CrossRefPubMed Rastelli AN, Jacomassi DP, Faloni AP, Queiroz TP, Rojas SS, Bernardi MI, Bagnato VS, Hernandes AC (2012) The filler content of the dental composite resins and their influence on different properties. Microsc Res Tech 75:758–765CrossRefPubMed
41.
go back to reference Bayne SC, Heymann HO, Swift EJ (1994) Update on dental composite restorations. J Am Dent Assoc 125:687–701CrossRefPubMed Bayne SC, Heymann HO, Swift EJ (1994) Update on dental composite restorations. J Am Dent Assoc 125:687–701CrossRefPubMed
42.
go back to reference Hosseinalipour M, Javadpour J, Rezaie H, Dadras T, Hayati AN (2010) Investigation of mechanical properties of experimental Bis-GMA/TEGDMA dental composite resins containing various mass fractions of silica nanoparticles. J Prosthodont 19:112–117CrossRefPubMed Hosseinalipour M, Javadpour J, Rezaie H, Dadras T, Hayati AN (2010) Investigation of mechanical properties of experimental Bis-GMA/TEGDMA dental composite resins containing various mass fractions of silica nanoparticles. J Prosthodont 19:112–117CrossRefPubMed
43.
go back to reference Kyo-Han K, Joo LO, Osamu O (2002) The effect of filler loading and morphology on the mechanical properties of contemporary composites. J Prosthet Dent 87:642–648CrossRef Kyo-Han K, Joo LO, Osamu O (2002) The effect of filler loading and morphology on the mechanical properties of contemporary composites. J Prosthet Dent 87:642–648CrossRef
44.
go back to reference Ikejima I, Nomoto R, McCabe J (2003) Shear punch strength and flexural strength of model composites with varying filler volume fraction. Particle size and silanation. Dent Mater 19:206–211CrossRefPubMed Ikejima I, Nomoto R, McCabe J (2003) Shear punch strength and flexural strength of model composites with varying filler volume fraction. Particle size and silanation. Dent Mater 19:206–211CrossRefPubMed
45.
go back to reference Suzuki S, Leinfelder KF, Kawai K, Tsuchitani Y (1995) Effect of particle variation on wear rates of posterior composites. Am J Dent 8:173–178PubMed Suzuki S, Leinfelder KF, Kawai K, Tsuchitani Y (1995) Effect of particle variation on wear rates of posterior composites. Am J Dent 8:173–178PubMed
46.
go back to reference Topcu FT, Erdemir U, Sahinkesen G, Yildiz E, Uslan I, Acikel C (2010) Evaluation of microhardness, surface roughness, and wear behavior of different types of resin composites polymerized with two different light sources. J Biomed Mater Res 92:470–480 Topcu FT, Erdemir U, Sahinkesen G, Yildiz E, Uslan I, Acikel C (2010) Evaluation of microhardness, surface roughness, and wear behavior of different types of resin composites polymerized with two different light sources. J Biomed Mater Res 92:470–480
47.
go back to reference Tomaszewska IM, Kearns JO, Ilie N, Fleming G (2015) Bulk fill restoratives: to cap or not to cap—that is the question? J Dent 43:309–316CrossRefPubMed Tomaszewska IM, Kearns JO, Ilie N, Fleming G (2015) Bulk fill restoratives: to cap or not to cap—that is the question? J Dent 43:309–316CrossRefPubMed
Metadata
Title
Comparison of flowable bulk-fill and flowable resin-based composites: an in vitro analysis
Authors
Frank Engelhardt
Sebastian Hahnel
Verena Preis
Martin Rosentritt
Publication date
01-11-2016
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 8/2016
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-015-1700-4

Other articles of this Issue 8/2016

Clinical Oral Investigations 8/2016 Go to the issue