Skip to main content
Top
Published in: Clinical Oral Investigations 5/2013

01-06-2013 | Original Article

Computer-aided evaluation of preparations for CAD/CAM-fabricated all-ceramic crowns

Authors: Jan-Frederik Güth, Jan Wallbach, Michael Stimmelmayr, Wolfgang Gernet, Florian Beuer, Daniel Edelhoff

Published in: Clinical Oral Investigations | Issue 5/2013

Login to get access

Abstract

Objective

The aim of this study was the evaluation of preparations from general dental practitioners for zirconia crowns and their correlation with clinical recommendations using a digital approach.

Material and method

Seventy-five datasets of left first upper molars (FDI 16) prepared for single zirconia crowns by general dental practitioners were analyzed using a computer-aided design software (LAVATM Design; 3M ESPE, Seefeld, Germany) and a 3D-inspection software (COMETinspect®plus version 4.5; Steinbichler Optotechnik, Neubeuern, Germany). Evaluated parameters were convergence angle, undercuts, interocclusal reduction, abutment height, and design of preparation margin.

Results

The mean convergence angle was determined to be 26.7°. The convergence angle in the mesiobuccal to distopalatal dimension was significantly the highest (31.7°), and the abutment height showed a mean value of 4.1 mm. Convergence angle and abutment height showed a negative correlation. Seventy-three percent of the evaluated locations revealed a margin design conforming to ceramic restorations. In over 30 % of the cases, the interocclusal reduction was insufficient. Generally, no preparation fulfilled all recommendations. Five (6.66 %) of the preparations fulfilled four criteria, 16 (21.33 %) preparations fulfilled three criteria, 31 (41.33 %) fulfilled two criteria, 17 (22.66 %) preparations fulfilled one criterion, and 6 (8 %) fulfilled no criterion.

Conclusions

Within the limitations of this study, most general dental practitioners seem to have difficulties fulfilling all clinical recommendations given for the preparation of zirconia crowns. The presented digital approach seems to be a useful method to evaluate the preparation geometry.

Clinical relevance

The correct preparation geometry represents an important prerequisite for the success of all-ceramic full crowns. As preparations clearly need to be improved, the approach presented could be the basis of a future tool to increase preparation quality in practice and education by direct objective feedback.
Literature
1.
go back to reference Edelhoff D, Sorensen JA (2002) Tooth structure removal associated with various preparation designs for anterior teeth. J Prosthet Dent 87:503–509PubMedCrossRef Edelhoff D, Sorensen JA (2002) Tooth structure removal associated with various preparation designs for anterior teeth. J Prosthet Dent 87:503–509PubMedCrossRef
2.
go back to reference Goodacre CJ, Campagni WV, Aquilion SA (2001) Tooth preparations for complete crowns: an art of form based on scientific principles. J Prosthet Dent 85:363–376PubMedCrossRef Goodacre CJ, Campagni WV, Aquilion SA (2001) Tooth preparations for complete crowns: an art of form based on scientific principles. J Prosthet Dent 85:363–376PubMedCrossRef
3.
go back to reference Annerstedt A, Engström U, Hansson A, Jansson T, Karlsson S, Liljhagen H, Lindquist E, Rydhammar E, Tyreman-Bandhede M, Svensson P, Wandel U (1996) Axial wall convergence of full veneer crown preparations. Documented for dental students and general practitioners. Acta Odontol Scand 54:109–112PubMedCrossRef Annerstedt A, Engström U, Hansson A, Jansson T, Karlsson S, Liljhagen H, Lindquist E, Rydhammar E, Tyreman-Bandhede M, Svensson P, Wandel U (1996) Axial wall convergence of full veneer crown preparations. Documented for dental students and general practitioners. Acta Odontol Scand 54:109–112PubMedCrossRef
4.
go back to reference Rosenstiel E (1975) The taper of inlay and crown preparations. A contribution to dental terminology. Br Dent J 139:436–438PubMedCrossRef Rosenstiel E (1975) The taper of inlay and crown preparations. A contribution to dental terminology. Br Dent J 139:436–438PubMedCrossRef
5.
go back to reference Beuer F, Aggstaller H, Richter J, Edelhoff D, Gernet W (2009) Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 40:243–250PubMed Beuer F, Aggstaller H, Richter J, Edelhoff D, Gernet W (2009) Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 40:243–250PubMed
6.
go back to reference Beuer F, Edelhoff D, Gernet W, Naumann M (2008) Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system. Dent Mater J 27:814–820PubMedCrossRef Beuer F, Edelhoff D, Gernet W, Naumann M (2008) Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system. Dent Mater J 27:814–820PubMedCrossRef
7.
go back to reference Wiskott HWA, Nicholls JI, Belser U (1996) The relationship between abutment taper and resistance of cemented crowns to dynamic loading. Int J Prosthodont 9:117–139PubMed Wiskott HWA, Nicholls JI, Belser U (1996) The relationship between abutment taper and resistance of cemented crowns to dynamic loading. Int J Prosthodont 9:117–139PubMed
8.
go back to reference Wilson AH Jr, Chan DC (1994) The relationship between preparation convergence and retention of extracoronal retainers. J Prosthodont 3:74–78PubMedCrossRef Wilson AH Jr, Chan DC (1994) The relationship between preparation convergence and retention of extracoronal retainers. J Prosthodont 3:74–78PubMedCrossRef
9.
go back to reference Giiboe DB, Teteruck WR (1974) Fundamentals of extracoronal tooth preparation. Part I, retention and resistance form. Prosthet Dent 32:651–656CrossRef Giiboe DB, Teteruck WR (1974) Fundamentals of extracoronal tooth preparation. Part I, retention and resistance form. Prosthet Dent 32:651–656CrossRef
10.
go back to reference Jorgensen KD (1955) The relationship between retention and convergence angle in cemented veneer crowns. Acta Odontol Scan 13:35–40CrossRef Jorgensen KD (1955) The relationship between retention and convergence angle in cemented veneer crowns. Acta Odontol Scan 13:35–40CrossRef
11.
go back to reference Kaufman EG, Coelho DH, Colin L (1961) Factors influencing the retention of cemented gold castings. J Prosth Dent 11:487–502CrossRef Kaufman EG, Coelho DH, Colin L (1961) Factors influencing the retention of cemented gold castings. J Prosth Dent 11:487–502CrossRef
12.
go back to reference Coelho PG, Silva NR, Thompson VP, Rekow D, Zhang G (2009) Effect of proximal wall height on all-ceramic crown core stress distribution: a finite element analysis study. Int J Prosthodont 22:78–86PubMed Coelho PG, Silva NR, Thompson VP, Rekow D, Zhang G (2009) Effect of proximal wall height on all-ceramic crown core stress distribution: a finite element analysis study. Int J Prosthodont 22:78–86PubMed
13.
go back to reference De Jager N, Pallev P, Feilzer AJ (2005) The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns. Dent Mater 21:242–251PubMedCrossRef De Jager N, Pallev P, Feilzer AJ (2005) The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns. Dent Mater 21:242–251PubMedCrossRef
14.
go back to reference Edelhoff D, Özcan M (2007) To what extent does the logevity of fixed dental prostheses depend on the function of the cement? Clin Oral Impl Res 18:193–204CrossRef Edelhoff D, Özcan M (2007) To what extent does the logevity of fixed dental prostheses depend on the function of the cement? Clin Oral Impl Res 18:193–204CrossRef
15.
go back to reference Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE (1997) Preparations for extensively damaged teeth. In: Fundamentals of fixed prosthodontics, 3rd edn. Quintessence Publishing Co. Inc., Chicago, pp 181–210 Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE (1997) Preparations for extensively damaged teeth. In: Fundamentals of fixed prosthodontics, 3rd edn. Quintessence Publishing Co. Inc., Chicago, pp 181–210
16.
go back to reference Cameron SM, Morris WJ, Keesee SM, Barsky TB, Parker MH (2006) The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading. J Prosth Dent 95:456–461CrossRef Cameron SM, Morris WJ, Keesee SM, Barsky TB, Parker MH (2006) The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading. J Prosth Dent 95:456–461CrossRef
17.
go back to reference Al-Omari WM, Al-Wahadni AM (2004) Convergence angle, occlusal reduction, and finish line depth of full-crown preparations made by dental students. Quintessence Int 35:287–292PubMed Al-Omari WM, Al-Wahadni AM (2004) Convergence angle, occlusal reduction, and finish line depth of full-crown preparations made by dental students. Quintessence Int 35:287–292PubMed
18.
go back to reference Rafeek RN, Smith WAJ, Seymour KG, Zou LF, Samarawickrama DYD (2010) Taper of full-veneer crown preparations by dental students at the University of the West Indies. J Prosthodont 19:580–585PubMedCrossRef Rafeek RN, Smith WAJ, Seymour KG, Zou LF, Samarawickrama DYD (2010) Taper of full-veneer crown preparations by dental students at the University of the West Indies. J Prosthodont 19:580–585PubMedCrossRef
19.
go back to reference NordlanderJ WD, Stoffer W et al (1988) The taper of clinical preparations for fixed prosthodontics. J Prosthet Dent 60:148–151CrossRef NordlanderJ WD, Stoffer W et al (1988) The taper of clinical preparations for fixed prosthodontics. J Prosthet Dent 60:148–151CrossRef
20.
go back to reference Stimmelmayr M, Erdelt K, Güth JF, Happe A, Beuer F (2012) Evaluation of impression accuracy for a four-implant mandibular model—a digital approach. Clin Oral Investig 16:1137–1142, PMID: 22009182PubMedCrossRef Stimmelmayr M, Erdelt K, Güth JF, Happe A, Beuer F (2012) Evaluation of impression accuracy for a four-implant mandibular model—a digital approach. Clin Oral Investig 16:1137–1142, PMID: 22009182PubMedCrossRef
21.
go back to reference Stimmelmayr M, Güth JF, Erdelt K, Edelhoff D, Beuer F (2012) Digital evaluation of the reproducibility of implant scanbody fit—an in vitro study. Clin Oral Investig 16(3):851–856PubMedCrossRef Stimmelmayr M, Güth JF, Erdelt K, Edelhoff D, Beuer F (2012) Digital evaluation of the reproducibility of implant scanbody fit—an in vitro study. Clin Oral Investig 16(3):851–856PubMedCrossRef
22.
go back to reference Gehrt M, Wolfart S, Rafai N, Reich S, Edelhoff D (2012) Clinical results of lithium-disilicate crowns after up to 9 years of service. Clin Oral Investig (In press) PMID: 2239163 Gehrt M, Wolfart S, Rafai N, Reich S, Edelhoff D (2012) Clinical results of lithium-disilicate crowns after up to 9 years of service. Clin Oral Investig (In press) PMID: 2239163
23.
go back to reference Wiskott HW, Nicholls JI, Belser UC (1997) The effect of tooth preparation height and diameter on the resistance of complete crowns to fatigue loading. Int J Prosthodont 10:207–215PubMed Wiskott HW, Nicholls JI, Belser UC (1997) The effect of tooth preparation height and diameter on the resistance of complete crowns to fatigue loading. Int J Prosthodont 10:207–215PubMed
24.
go back to reference Hegdahl T, Silness J (1977) Preparation areas resisting displacement of artificial crowns. J Oral Rehabil 4:201–207PubMedCrossRef Hegdahl T, Silness J (1977) Preparation areas resisting displacement of artificial crowns. J Oral Rehabil 4:201–207PubMedCrossRef
25.
go back to reference Sato T, Al Mutawa N, Okada D, Hasegawa S (1998) A clinical study on abutment taper and height of full cast crown preparations. J Med Dent Sci 45:205–210PubMed Sato T, Al Mutawa N, Okada D, Hasegawa S (1998) A clinical study on abutment taper and height of full cast crown preparations. J Med Dent Sci 45:205–210PubMed
26.
go back to reference El-Mowafy OM, Fenton AH, Forrester N, Milenkovic M (1996) Retention of metal ceramic crowns cemented with resin cements: effects of preparation taper and height. J Prosthet Dent 76:524–529PubMedCrossRef El-Mowafy OM, Fenton AH, Forrester N, Milenkovic M (1996) Retention of metal ceramic crowns cemented with resin cements: effects of preparation taper and height. J Prosthet Dent 76:524–529PubMedCrossRef
27.
go back to reference Zidan O, Ferguson GC (2003) The retention of complete crowns prepared with three different tapers and luted with four different cements. J Prosthet Dent 89:565–571PubMedCrossRef Zidan O, Ferguson GC (2003) The retention of complete crowns prepared with three different tapers and luted with four different cements. J Prosthet Dent 89:565–571PubMedCrossRef
28.
go back to reference Sarafianou A, Kafandaris NM (1997) Effect of convergence angle on retention of resin bonded retainers cemented with resinous cements. J Prosthet Dent 77:475–481PubMedCrossRef Sarafianou A, Kafandaris NM (1997) Effect of convergence angle on retention of resin bonded retainers cemented with resinous cements. J Prosthet Dent 77:475–481PubMedCrossRef
29.
go back to reference Baltzer A (2008) All-ceramic single-tooth restorations: choosing the material to match the preparation-preparing the tooth to match the material. Int J Comput Dent 11:241–256PubMed Baltzer A (2008) All-ceramic single-tooth restorations: choosing the material to match the preparation-preparing the tooth to match the material. Int J Comput Dent 11:241–256PubMed
30.
go back to reference Bindl A, Luthy H, Moermann WH (2006) Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns. Dent Mater 22:29–36PubMedCrossRef Bindl A, Luthy H, Moermann WH (2006) Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns. Dent Mater 22:29–36PubMedCrossRef
31.
go back to reference Moermann WH, Bindl A, Luthy H, Rathke A (1998) Effects of preparation and luting system on all-ceramic computer-generated crowns. Int J Prosthodont 11:333–339 Moermann WH, Bindl A, Luthy H, Rathke A (1998) Effects of preparation and luting system on all-ceramic computer-generated crowns. Int J Prosthodont 11:333–339
32.
go back to reference Ayad MF, Maghrabi AA, Rosenstiel SF (2005) Assessment of convergence angles of tooth preparations for complete crowns among dental students. J Dent 33:633–638PubMedCrossRef Ayad MF, Maghrabi AA, Rosenstiel SF (2005) Assessment of convergence angles of tooth preparations for complete crowns among dental students. J Dent 33:633–638PubMedCrossRef
33.
go back to reference Chan DC, Wilson AH Jr, Barbe P, Cronin RJ Jr et al (2005) Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns. J Oral Rehabil 32:58–64PubMedCrossRef Chan DC, Wilson AH Jr, Barbe P, Cronin RJ Jr et al (2005) Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns. J Oral Rehabil 32:58–64PubMedCrossRef
34.
go back to reference Iwai T, Komine F, Kobayashi K, Saito A et al (2008) Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings. Acta Odontol Scand 66:214–218PubMedCrossRef Iwai T, Komine F, Kobayashi K, Saito A et al (2008) Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings. Acta Odontol Scand 66:214–218PubMedCrossRef
35.
go back to reference Parker MH, Calvery MJ, Gardner FM, Gunderson RB (1993) New guidelines for preparation taper. J Prosthodont 2:61–66PubMedCrossRef Parker MH, Calvery MJ, Gardner FM, Gunderson RB (1993) New guidelines for preparation taper. J Prosthodont 2:61–66PubMedCrossRef
36.
go back to reference Parker MH, Gunderson RB, Gardner FM, Calverley MJ (1988) Quantitative determination of taper adequate to provide resistance form: concept of limiting taper. J Prosthet Dent 59:281–288PubMedCrossRef Parker MH, Gunderson RB, Gardner FM, Calverley MJ (1988) Quantitative determination of taper adequate to provide resistance form: concept of limiting taper. J Prosthet Dent 59:281–288PubMedCrossRef
37.
go back to reference Mack PJ (1980) A theoretical and clinical investigation into the taper achieved on crown and inlay preparations. J Oral Rehabil 7:255–265PubMedCrossRef Mack PJ (1980) A theoretical and clinical investigation into the taper achieved on crown and inlay preparations. J Oral Rehabil 7:255–265PubMedCrossRef
38.
go back to reference Ohm E, Silness J (1978) The convergence angle in teeth prepared for artificial crowns. J Oral Rehabil 5:371–375PubMedCrossRef Ohm E, Silness J (1978) The convergence angle in teeth prepared for artificial crowns. J Oral Rehabil 5:371–375PubMedCrossRef
39.
go back to reference Poon BK, Smales RJ (2001) Assessment of clinical preparations for single gold and ceramometal crowns. Quintessence Int 32:603–610PubMed Poon BK, Smales RJ (2001) Assessment of clinical preparations for single gold and ceramometal crowns. Quintessence Int 32:603–610PubMed
Metadata
Title
Computer-aided evaluation of preparations for CAD/CAM-fabricated all-ceramic crowns
Authors
Jan-Frederik Güth
Jan Wallbach
Michael Stimmelmayr
Wolfgang Gernet
Florian Beuer
Daniel Edelhoff
Publication date
01-06-2013
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 5/2013
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-012-0812-3

Other articles of this Issue 5/2013

Clinical Oral Investigations 5/2013 Go to the issue