Published in: Clinical Oral Investigations 3/2012

01-06-2012 | Original Article

Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses

Authors: Roberto Sorrentino, Giorgio De Simone, Stefano Tetè, Simona Russo, Fernando Zarone

Published in: Clinical Oral Investigations | Issue 3/2012

Login to get access

Abstract

This prospective clinical trial aimed at evaluating the clinical performance of three-unit posterior zirconia fixed dental prostheses (FDPs) after 5 years of clinical function. Thirty-seven patients received 48 three-unit zirconia-based FDPs. The restorations replaced either a premolar or a molar. Specific inclusion criteria were needed. Tooth preparation was standardized. Computer-aided design/computer-assisted manufacturing frameworks with a 9-mm2 cross section of the connector and a 0.6-mm minimum thickness of the retainer were made. The restorations were luted with resin cement. The patients were recalled after 1, 6, 12, 24, 36, 48, and 60 months. The survival and success of the ceramics and zirconia were evaluated. The technical and aesthetic outcomes were examined using the United States Public Health Service criteria. The biologic outcomes were analyzed at abutment and contralateral teeth. Descriptive statistics were performed. All FDPs completed the study, resulting in 100% cumulative survival rate and 91.9% and 95.4% cumulative success rates for patients wearing one and two FDPs, respectively. No losses of retention were recorded. Forty-two restorations were rated alpha in all measured parameters. A minor chipping of the ceramics was detected in three restorations. No significant differences between the periodontal parameters of the test and control teeth were observed. Five-year clinical results proved that three-unit posterior zirconia-based FDPs were successful in the medium term for both function and aesthetic. Zirconia can be considered a promising substitute of metal frameworks for the fabrication of short-span posterior prostheses.
Literature
1.
2.
go back to reference Tsumita M, Kokubo Y, Ohkubo C, Sakurai S, Fukushima S (2010) Clinical evaluation of posterior all-ceramic FPDs (Cercon): a prospective clinical pilot study. J Prosthodont Res 54:102–105PubMedCrossRef Tsumita M, Kokubo Y, Ohkubo C, Sakurai S, Fukushima S (2010) Clinical evaluation of posterior all-ceramic FPDs (Cercon): a prospective clinical pilot study. J Prosthodont Res 54:102–105PubMedCrossRef
3.
go back to reference Vult von Steyern P, Carlson P, Nilner K (2005) All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 32:180–187PubMedCrossRef Vult von Steyern P, Carlson P, Nilner K (2005) All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil 32:180–187PubMedCrossRef
4.
go back to reference Sailer I, Gottnerb J, Kanelb S, Hammerle CH (2009) Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. Int J Prosthodont 22:553–560PubMed Sailer I, Gottnerb J, Kanelb S, Hammerle CH (2009) Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up. Int J Prosthodont 22:553–560PubMed
5.
go back to reference Sadan A, Blatz MB, Lang B (2005) Clinical considerations for densely sintered alumina and zirconia restorations: part 1. Int J Periodontics Restorative Dent 25:213–219PubMed Sadan A, Blatz MB, Lang B (2005) Clinical considerations for densely sintered alumina and zirconia restorations: part 1. Int J Periodontics Restorative Dent 25:213–219PubMed
6.
go back to reference Sadan A, Blatz MB, Lang B (2005) Clinical considerations for densely sintered alumina and zirconia restorations: part 2. Int J Periodontics Restorative Dent 25:343–349PubMed Sadan A, Blatz MB, Lang B (2005) Clinical considerations for densely sintered alumina and zirconia restorations: part 2. Int J Periodontics Restorative Dent 25:343–349PubMed
7.
go back to reference Eschbach S, Wolfart S, Bohlsen F, Kern M (2009) Clinical evaluation of all-ceramic posterior three-unit FDPs made of In-Ceram Zirconia. Int J Prosthodont 22:490–492PubMed Eschbach S, Wolfart S, Bohlsen F, Kern M (2009) Clinical evaluation of all-ceramic posterior three-unit FDPs made of In-Ceram Zirconia. Int J Prosthodont 22:490–492PubMed
8.
go back to reference Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, Mercante DE (2006) The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 96:237–244PubMedCrossRef Raigrodski AJ, Chiche GJ, Potiket N, Hochstedler JL, Mohamed SE, Billiot S, Mercante DE (2006) The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study. J Prosthet Dent 96:237–244PubMedCrossRef
9.
go back to reference Christel P, Meunier A, Heller M, Torre JP, Peille CN (1989) Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. J Biomed Mater Res 23:45–61PubMedCrossRef Christel P, Meunier A, Heller M, Torre JP, Peille CN (1989) Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia. J Biomed Mater Res 23:45–61PubMedCrossRef
10.
go back to reference Rimondini L, Cerroni L, Carrassi A, Torricelli P (2002) Bacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study. Int J Oral Maxillofac Implants 17:793–798PubMed Rimondini L, Cerroni L, Carrassi A, Torricelli P (2002) Bacterial colonization of zirconia ceramic surfaces: an in vitro and in vivo study. Int J Oral Maxillofac Implants 17:793–798PubMed
11.
go back to reference Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A (2004) Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol 75:292–296PubMedCrossRef Scarano A, Piattelli M, Caputi S, Favero GA, Piattelli A (2004) Bacterial adhesion on commercially pure titanium and zirconium oxide disks: an in vivo human study. J Periodontol 75:292–296PubMedCrossRef
12.
go back to reference Ernst CP, Cohnen U, Stender E, Willershausen B (2005) In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents. J Prosthet Dent 93:551–558PubMedCrossRef Ernst CP, Cohnen U, Stender E, Willershausen B (2005) In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents. J Prosthet Dent 93:551–558PubMedCrossRef
13.
go back to reference Chai J, Chu FC, Chow TW, Liang BM (2007) Chemical solubility and flexural strength of zirconia-based ceramics. Int J Prosthodont 20:587–595PubMed Chai J, Chu FC, Chow TW, Liang BM (2007) Chemical solubility and flexural strength of zirconia-based ceramics. Int J Prosthodont 20:587–595PubMed
14.
go back to reference Beuer F, Edelhoff D, Gernet W, Sorensen JA (2009) Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs). Clin Oral Investig 13:445–451PubMedCrossRef Beuer F, Edelhoff D, Gernet W, Sorensen JA (2009) Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs). Clin Oral Investig 13:445–451PubMedCrossRef
15.
go back to reference Odman P, Andersson B (2001) Procera AllCeram crowns followed for 5 to 10.5 years: a prospective clinical study. Int J Prosthodont 14:504–509PubMed Odman P, Andersson B (2001) Procera AllCeram crowns followed for 5 to 10.5 years: a prospective clinical study. Int J Prosthodont 14:504–509PubMed
16.
go back to reference Fradeani M, D'Amelio M, Redemagni M, Corrado M (2005) Five-year follow-up with Procera all-ceramic crowns. Quintessence Int 36:105–113PubMed Fradeani M, D'Amelio M, Redemagni M, Corrado M (2005) Five-year follow-up with Procera all-ceramic crowns. Quintessence Int 36:105–113PubMed
17.
go back to reference Vult von Steyern P (2005) All-ceramic fixed partial dentures. Studies on aluminium oxide- and zirconium dioxide-based ceramic systems. Swed Dent J Suppl 173:1–69PubMed Vult von Steyern P (2005) All-ceramic fixed partial dentures. Studies on aluminium oxide- and zirconium dioxide-based ceramic systems. Swed Dent J Suppl 173:1–69PubMed
18.
go back to reference Zarone F, Sorrentino R, Vaccaro F, Russo S, De Simone G (2005) Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments. Clin Implant Dent Relat Res 7(Suppl 1):S95–S103PubMedCrossRef Zarone F, Sorrentino R, Vaccaro F, Russo S, De Simone G (2005) Retrospective clinical evaluation of 86 Procera AllCeram anterior single crowns on natural and implant-supported abutments. Clin Implant Dent Relat Res 7(Suppl 1):S95–S103PubMedCrossRef
19.
go back to reference Pjetursson BE, Sailer I, Zwahlen M, Hämmerle CH (2007) A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns. Clin Oral Implants Res 18(Suppl 3):73–85PubMedCrossRef Pjetursson BE, Sailer I, Zwahlen M, Hämmerle CH (2007) A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns. Clin Oral Implants Res 18(Suppl 3):73–85PubMedCrossRef
20.
go back to reference Sorrentino R, Galasso L, Tetè S, De Simone G, Zarone F (2009) Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: a 6-year retrospective study. Clin Implant Dent Relat Res. doi:10.1111/j.1708-8208.2009.00251.x Sorrentino R, Galasso L, Tetè S, De Simone G, Zarone F (2009) Clinical evaluation of 209 all-ceramic single crowns cemented on natural and implant-supported abutments with different luting agents: a 6-year retrospective study. Clin Implant Dent Relat Res. doi:10.​1111/​j.​1708-8208.​2009.​00251.​x
21.
go back to reference Creugers NH, Käyser AF, van 't Hof MA (1994) A meta-analysis of durability data on conventional fixed bridges. Community Dent Oral Epidemiol 22:448–452PubMedCrossRef Creugers NH, Käyser AF, van 't Hof MA (1994) A meta-analysis of durability data on conventional fixed bridges. Community Dent Oral Epidemiol 22:448–452PubMedCrossRef
22.
go back to reference Scurria MS, Bader JD, Shugars DA (1998) Meta-analysis of fixed partial denture survival: prostheses and abutments. J Prosthet Dent 79:459–464PubMedCrossRef Scurria MS, Bader JD, Shugars DA (1998) Meta-analysis of fixed partial denture survival: prostheses and abutments. J Prosthet Dent 79:459–464PubMedCrossRef
23.
go back to reference Marquardt P, Strub JR (2006) Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study. Quintessence Int 37:253–259PubMed Marquardt P, Strub JR (2006) Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study. Quintessence Int 37:253–259PubMed
24.
go back to reference Esquivel-Upshaw JF, Young H, Jones J, Yang M, Anusavice KJ (2008) Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures. Int J Prosthodont 21:155–160PubMed Esquivel-Upshaw JF, Young H, Jones J, Yang M, Anusavice KJ (2008) Four-year clinical performance of a lithia disilicate-based core ceramic for posterior fixed partial dentures. Int J Prosthodont 21:155–160PubMed
25.
go back to reference Vult von Steyern P, Jönsson O, Nilner K (2001) Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont 14:379–384PubMed Vult von Steyern P, Jönsson O, Nilner K (2001) Five-year evaluation of posterior all-ceramic three-unit (In-Ceram) FPDs. Int J Prosthodont 14:379–384PubMed
26.
go back to reference Suárez MJ, Lozano JF, Paz Salido M, Martínez F (2004) Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs. Int J Prosthodont 17:35–38PubMed Suárez MJ, Lozano JF, Paz Salido M, Martínez F (2004) Three-year clinical evaluation of In-Ceram Zirconia posterior FPDs. Int J Prosthodont 17:35–38PubMed
27.
go back to reference Esquivel-Upshaw JF, Anusavice KJ, Young H, Jones J, Gibbs C (2004) Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs. Int J Prosthodont 17:469–475PubMed Esquivel-Upshaw JF, Anusavice KJ, Young H, Jones J, Gibbs C (2004) Clinical performance of a lithia disilicate-based core ceramic for three-unit posterior FPDs. Int J Prosthodont 17:469–475PubMed
28.
go back to reference Sailer I, Fehér A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed Sailer I, Fehér A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388PubMed
29.
go back to reference Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227PubMed Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227PubMed
30.
go back to reference Wolfart S, Harder S, Eschbach S, Lehmann F, Kern M (2009) Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design. Eur J Oral Sci 117:741–749PubMedCrossRef Wolfart S, Harder S, Eschbach S, Lehmann F, Kern M (2009) Four-year clinical results of fixed dental prostheses with zirconia substructures (Cercon): end abutments vs. cantilever design. Eur J Oral Sci 117:741–749PubMedCrossRef
31.
go back to reference Roediger M, Gersdorff N, Huels A, Rinke S (2010) Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results. Int J Prosthodont 23:141–148PubMed Roediger M, Gersdorff N, Huels A, Rinke S (2010) Prospective evaluation of zirconia posterior fixed partial dentures: four-year clinical results. Int J Prosthodont 23:141–148PubMed
32.
go back to reference Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O (2009) Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. J Oral Rehabil 36:610–615PubMedCrossRef Schmitter M, Mussotter K, Rammelsberg P, Stober T, Ohlmann B, Gabbert O (2009) Clinical performance of extended zirconia frameworks for fixed dental prostheses: two-year results. J Oral Rehabil 36:610–615PubMedCrossRef
33.
go back to reference Tan K, Pjetursson BE, Lang NP, Chan ES (2004) A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res 15:654–666PubMedCrossRef Tan K, Pjetursson BE, Lang NP, Chan ES (2004) A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. Clin Oral Implants Res 15:654–666PubMedCrossRef
34.
go back to reference Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21:217–222PubMed Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H (2008) Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 21:217–222PubMed
35.
go back to reference Fischer J, Stawarczyk B, Hammerle CH (2008) Flexural strength of veneering ceramics for zirconia. J Dent 36:316–321PubMedCrossRef Fischer J, Stawarczyk B, Hammerle CH (2008) Flexural strength of veneering ceramics for zirconia. J Dent 36:316–321PubMedCrossRef
36.
go back to reference Aboushelib MN, Kleverlaan CJ, Feilzer AJ (2008) Effect of zirconia type on its bond strength with different veneer ceramics. J Prosthodont 17:401–408PubMedCrossRef Aboushelib MN, Kleverlaan CJ, Feilzer AJ (2008) Effect of zirconia type on its bond strength with different veneer ceramics. J Prosthodont 17:401–408PubMedCrossRef
37.
go back to reference Zarone F, Sorrentino R, Traini T, Di lorio D, Caputi S (2007) Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis. Dent Mater 23:296–301PubMedCrossRef Zarone F, Sorrentino R, Traini T, Di lorio D, Caputi S (2007) Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis. Dent Mater 23:296–301PubMedCrossRef
38.
go back to reference Larsson C, Holm L, Lövgren N, Kokubo Y, Vult von Steyern P (2007) Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study. J Oral Rehabil 34:702–709PubMedCrossRef Larsson C, Holm L, Lövgren N, Kokubo Y, Vult von Steyern P (2007) Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study. J Oral Rehabil 34:702–709PubMedCrossRef
39.
go back to reference Bahat Z, Mahmood DJ, Vult von Steyern P (2009) Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design. Swed Dent J 33:149–159PubMed Bahat Z, Mahmood DJ, Vult von Steyern P (2009) Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design. Swed Dent J 33:149–159PubMed
40.
go back to reference Oh WS, Anusavice KJ (2002) Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. J Prosthet Dent 87:536–542PubMedCrossRef Oh WS, Anusavice KJ (2002) Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures. J Prosthet Dent 87:536–542PubMedCrossRef
Metadata
Title
Five-year prospective clinical study of posterior three-unit zirconia-based fixed dental prostheses
Authors
Roberto Sorrentino
Giorgio De Simone
Stefano Tetè
Simona Russo
Fernando Zarone
Publication date
01-06-2012
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 3/2012
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-011-0575-2

Other articles of this Issue 3/2012

Clinical Oral Investigations 3/2012 Go to the issue