Abstract

The purpose of this study was to evaluate the temperature rise during polymerization of three different provisional materials by direct method on two different dentin disc thicknesses. Two autopolymerizing; bis-acrylic composite (Fill-in; Kerr), polymethyl methacrylate (Temdent; Weil Dental), and one light polymerizing composite (Revotek LC; GC) provisional restoration materials were used in this study. Sixty dentin discs were prepared from extracted molars (diameter, 5 mm; height, 1 or 2 mm). These dentin discs (1 or 2 mm) were placed on apparatus developed to measure temperature rise. The temperature rise during polymerization was measured under the dentin disc with a J-type thermocouple wire that was connected to a data logger. Statistical analysis was performed with two-way analysis of variance followed by Tukey HSD test (α = 0.05). Temperature rise values statistically varied according to the provisional restoration material used (light polymerized, auto polymerized; P< 0.001) and the dentin thickness (1 and 2 mm; P <0.001). The polymethyl methacrylate based provisional material induced significantly higher temperature rise than other provisional restoration materials at 2-mm dentin thickness (P < 0.01). At 1-mm dentin thickness, polymethyl methacrylate and composite induced significantly higher temperature increase than bis-acrylic composite provisional material (P < 0.05). The risk for heat-induced pulpal damage should be taken into consideration during polymerization of provisional materials in deep cavities in which dentin thickness is less than 1 mm.
Literature
1.
go back to reference Driscoll CF, Woolsey G, Ferguson WM (1991) Comparison of exothermic release during polymerization of four materials used to fabricate interim restorations. J Prosthet Dent 65:504–506PubMedCrossRef Driscoll CF, Woolsey G, Ferguson WM (1991) Comparison of exothermic release during polymerization of four materials used to fabricate interim restorations. J Prosthet Dent 65:504–506PubMedCrossRef
2.
go back to reference Hensen EK, Asmussen E (1993) Correlation between dept of cure and temperature rise of a light-activated resin. Scand J Dent Res 101:176–179 Hensen EK, Asmussen E (1993) Correlation between dept of cure and temperature rise of a light-activated resin. Scand J Dent Res 101:176–179
3.
go back to reference Hussey D, Biagioni P, Lamey P (1995) Thermographic measurement of temperature change during resin polymerization in vivo. J Dent 23:267–271PubMedCrossRef Hussey D, Biagioni P, Lamey P (1995) Thermographic measurement of temperature change during resin polymerization in vivo. J Dent 23:267–271PubMedCrossRef
4.
go back to reference Kim S-H, Watts DC (2004) Exothermic behavior of the polymer-based provisional crown and fixed partial denture materials. Dent Mater 20:383–387PubMedCrossRef Kim S-H, Watts DC (2004) Exothermic behavior of the polymer-based provisional crown and fixed partial denture materials. Dent Mater 20:383–387PubMedCrossRef
5.
go back to reference Moulding MB, Loney RW (1991) The effect of cooling techniques on intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 4:332–336PubMed Moulding MB, Loney RW (1991) The effect of cooling techniques on intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 4:332–336PubMed
6.
go back to reference Moulding MB, Teplisky PE (1990) Intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 3:299–304PubMed Moulding MB, Teplisky PE (1990) Intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 3:299–304PubMed
7.
go back to reference Raab WHM (1992) Temperature changes in pulpal microcirculation. Proc Fin Dent Soc 88:469–479 Raab WHM (1992) Temperature changes in pulpal microcirculation. Proc Fin Dent Soc 88:469–479
8.
go back to reference Young HM, Smith CT, Morton D (2001) Comparative in vitro evaluation of two provisional restorative materials. J Prosthet Dent 85:129–132PubMedCrossRef Young HM, Smith CT, Morton D (2001) Comparative in vitro evaluation of two provisional restorative materials. J Prosthet Dent 85:129–132PubMedCrossRef
9.
go back to reference Zach L, Cohen C (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Path 19:515–530PubMedCrossRef Zach L, Cohen C (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Path 19:515–530PubMedCrossRef
Metadata
Title
Temperature rise during polymerization of three different provisional materials
Authors
Subutay Han Altintas
Isa Yondem
Onjen Tak
Aslihan Usumez
Publication date
01-09-2008
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 3/2008
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-007-0163-7

Other articles of this Issue 3/2008

Clinical Oral Investigations 3/2008 Go to the issue