Skip to main content
Top
Published in: Clinical Oral Investigations 3/2005

01-09-2005 | Original Article

Quantification of oxidative metabolism in masseter muscle of denture wearers

Authors: A. Fujii, T. Shinogaya, S. Toda, I. Hayakawa

Published in: Clinical Oral Investigations | Issue 3/2005

Login to get access

Abstract

This study aimed to quantify oxidative metabolism in masseter muscle using near-infrared spectroscopy, in particular for denture wearers. Fourteen normal dentate subjects without malocclusion (ND group, 25–50 years) participated in the quantification of oxidative metabolism. Eleven partially edentulous patients without occlusal stops (PD group, 64–80 years) and ten edentulous patients (CD group, 57–84 years) also participated after prosthodontic treatment. Oxidative metabolism was recorded during gum chewing, maximum clenching and regulated clenching at 5 kgf. The oxygenated hemoglobin at 5 kgf clenching level was normalized to the oxygenated hemoglobin at the lowest blood flow and expressed as oxygen consumption rate (OCR). The relationship of the OCR to the maximum clenching force was analyzed using Pearson’s correlation coefficient, and differences between the PD and CD groups were tested by unpaired Student’s t-test. The OCR showed a significant negative correlation with maximum clenching force in the ND group. The OCR of the PD group was significantly greater than that of the CD group, although the difference in maximum clenching force was not significant between both groups. These results suggest that the aerobic ability of masseter muscle in complete denture wearers is relatively greater than in partial denture wearers with same age level.
Literature
1.
go back to reference Hamaoka T, McCully KK, Katsumura T, Shimomitsu T, Chance B (2000) Noninvasive measures of muscle metabolism. In: Chandan K, Lester P, Osmo OP (eds) Handbook of oxidants and antioxidants in exercise. Elsevier, Amsterdam, pp 485–509 Hamaoka T, McCully KK, Katsumura T, Shimomitsu T, Chance B (2000) Noninvasive measures of muscle metabolism. In: Chandan K, Lester P, Osmo OP (eds) Handbook of oxidants and antioxidants in exercise. Elsevier, Amsterdam, pp 485–509
2.
go back to reference Hamaoka T, Iwane H, Shimomitsu T, Katsumura T, Murase N, Nishio S, Osada T, Kurosawa Y, Chance B (1996) Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy. J Appl Physiol 81:1410–1417PubMed Hamaoka T, Iwane H, Shimomitsu T, Katsumura T, Murase N, Nishio S, Osada T, Kurosawa Y, Chance B (1996) Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy. J Appl Physiol 81:1410–1417PubMed
3.
go back to reference Chance B, Dait MT, Zhang C, Hamoka T, Hagerman F (1992) Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers. Am J Physiol 262(Cell Physiol 31):C766–C775PubMed Chance B, Dait MT, Zhang C, Hamoka T, Hagerman F (1992) Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers. Am J Physiol 262(Cell Physiol 31):C766–C775PubMed
4.
go back to reference Delcanho RE, Kim YJ, Clark GT (1996) Haemodynamic changes induced by submaximal isometric contraction in painful and non-painful human masseter using near-infra-red spectroscopy. Arch Oral Biol 41:585–596PubMed Delcanho RE, Kim YJ, Clark GT (1996) Haemodynamic changes induced by submaximal isometric contraction in painful and non-painful human masseter using near-infra-red spectroscopy. Arch Oral Biol 41:585–596PubMed
5.
go back to reference Fujinami Y, Hayakawa I, Hirano S, Watanabe I (2003) Changes in postural control of complete denture wearers after receiving new dentures. Prosthodont Res Prac 2:11–19 Fujinami Y, Hayakawa I, Hirano S, Watanabe I (2003) Changes in postural control of complete denture wearers after receiving new dentures. Prosthodont Res Prac 2:11–19
6.
go back to reference Tallgren A, Tryde G (1991) Chewing and swallowing activity of masticatory muscles in patients with a complete upper and a partial lower denture. J Oral Rehabil 18:285–299PubMed Tallgren A, Tryde G (1991) Chewing and swallowing activity of masticatory muscles in patients with a complete upper and a partial lower denture. J Oral Rehabil 18:285–299PubMed
7.
go back to reference Sasaki A (2001) Influence of mastication on the amount of hemoglobin in human brain tissue (in Japanese). J Stomatol Soc 68:72–81 Sasaki A (2001) Influence of mastication on the amount of hemoglobin in human brain tissue (in Japanese). J Stomatol Soc 68:72–81
8.
go back to reference Niwayama M, Lin L, Shao J, Kudo N, Yamamoto K (2000) Quantitative measurement of muscle hemoglobin oxygenation using near-infrared spectroscopy with correction for the influence of a subcutaneous fat layer. Rev Sci Instrum 71:4571–4575 Niwayama M, Lin L, Shao J, Kudo N, Yamamoto K (2000) Quantitative measurement of muscle hemoglobin oxygenation using near-infrared spectroscopy with correction for the influence of a subcutaneous fat layer. Rev Sci Instrum 71:4571–4575
9.
go back to reference Cui W, Kumar C, Chance B (1991) Experimental study of migration depth for the photons measured at sample surface. Proc Int Soc Opt Eng 1431:180–191 Cui W, Kumar C, Chance B (1991) Experimental study of migration depth for the photons measured at sample surface. Proc Int Soc Opt Eng 1431:180–191
10.
go back to reference Harris RC, Hultman E, Nordesjo LO (1974) Glycogen, glycolytic intermediates and high-energy phosphates determined in biopsy samples of musculus quadriceps femoris of manta rest. Methods and variance of values. Scand J Clin Lab Invest 33:109–120PubMed Harris RC, Hultman E, Nordesjo LO (1974) Glycogen, glycolytic intermediates and high-energy phosphates determined in biopsy samples of musculus quadriceps femoris of manta rest. Methods and variance of values. Scand J Clin Lab Invest 33:109–120PubMed
11.
go back to reference Forrester JS (1972) Thermodilution cardiac output determination with a single flow-directed catheter. Am Heart J 83:306PubMed Forrester JS (1972) Thermodilution cardiac output determination with a single flow-directed catheter. Am Heart J 83:306PubMed
12.
go back to reference Jöbsis FF (1977) Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 198:1264–1267PubMed Jöbsis FF (1977) Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 198:1264–1267PubMed
13.
go back to reference De Blasi RA, Cope M, Elwell C, Safoue F, Ferrari M (1993) Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy. Eur J Appl Physiol 67:20–25 De Blasi RA, Cope M, Elwell C, Safoue F, Ferrari M (1993) Noninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy. Eur J Appl Physiol 67:20–25
14.
go back to reference Ohkubo M, Shimomitsu T, Hamaoka T, Esaki K, Kime R, Fujimaru Y, Ohtsuki T, Sakamoto A, Katsumura T (2000) Measurement of blood volume in musculus trapezius by near infrared spectroscopy (in Japanese). Ther Res 21:1511–1515 Ohkubo M, Shimomitsu T, Hamaoka T, Esaki K, Kime R, Fujimaru Y, Ohtsuki T, Sakamoto A, Katsumura T (2000) Measurement of blood volume in musculus trapezius by near infrared spectroscopy (in Japanese). Ther Res 21:1511–1515
15.
go back to reference Humphreys PW, Lind AR (1963) The blood flow through active and inactive muscles of the forearm during sustained hand-grip contractions. J Physiol 166:120–135PubMed Humphreys PW, Lind AR (1963) The blood flow through active and inactive muscles of the forearm during sustained hand-grip contractions. J Physiol 166:120–135PubMed
16.
go back to reference Barcroft H, Millen JLE (1939) The blood flow through muscle during sustained contraction. J Physiol 97:17–31 Barcroft H, Millen JLE (1939) The blood flow through muscle during sustained contraction. J Physiol 97:17–31
17.
go back to reference Bonde-Peterson F, Mork AL, Nielsen E (1975) Local muscle blood flow and sustained contractions of human arm and back muscles. Eur J Appl Physiol 34:43–50 Bonde-Peterson F, Mork AL, Nielsen E (1975) Local muscle blood flow and sustained contractions of human arm and back muscles. Eur J Appl Physiol 34:43–50
18.
go back to reference Kimura N, Katsumura T, Hamaoka T, Shimomitsu T (1999) The estimation of oxygen availability in muscle during isometric exercise by near infrared spectroscopy (in Japanese). Nihon Undo Seirigaku Gakkai Zasshi 6:93–102 Kimura N, Katsumura T, Hamaoka T, Shimomitsu T (1999) The estimation of oxygen availability in muscle during isometric exercise by near infrared spectroscopy (in Japanese). Nihon Undo Seirigaku Gakkai Zasshi 6:93–102
19.
go back to reference Schantz P, Fox ER, Norgren P, Tyden A (1981) The relationship between the mean muscle fiber area and the muscle cross-section area of the thigh in subject with large differences in thigh girth. Acta Physiol Scand 133:537–539 Schantz P, Fox ER, Norgren P, Tyden A (1981) The relationship between the mean muscle fiber area and the muscle cross-section area of the thigh in subject with large differences in thigh girth. Acta Physiol Scand 133:537–539
20.
go back to reference Holloszy JO, Booth FW (1976) Biochemical adaptations to endurance exercise in muscle. Annu Rev Physiol 38:273–291PubMed Holloszy JO, Booth FW (1976) Biochemical adaptations to endurance exercise in muscle. Annu Rev Physiol 38:273–291PubMed
21.
go back to reference Yamashita S, Sakai S, Hatch JP, Rugh JD (2000) Relationship between oral function and occlusal support in denture wearers. J Oral Rehabil 27:881–886PubMed Yamashita S, Sakai S, Hatch JP, Rugh JD (2000) Relationship between oral function and occlusal support in denture wearers. J Oral Rehabil 27:881–886PubMed
22.
go back to reference Garrett NR, Perez P, Elbert C, Kapur KK (1996) Effects of improvements of poorly fitting dentures and new dentures on masseter activity during chewing. J Prosthet Dent 76:394–402PubMed Garrett NR, Perez P, Elbert C, Kapur KK (1996) Effects of improvements of poorly fitting dentures and new dentures on masseter activity during chewing. J Prosthet Dent 76:394–402PubMed
23.
go back to reference Garrett NR, Perez P, Elbert C, Kapur KK (1996) Effects of improvements of poorly fitting dentures on masticatory performance. J Prosthet Dent 75:269–275PubMed Garrett NR, Perez P, Elbert C, Kapur KK (1996) Effects of improvements of poorly fitting dentures on masticatory performance. J Prosthet Dent 75:269–275PubMed
24.
go back to reference Gunne HJ (1985) The effect of removable partial dentures on mastication and dietary intake. Acta Odontol Scand 43:269–278PubMed Gunne HJ (1985) The effect of removable partial dentures on mastication and dietary intake. Acta Odontol Scand 43:269–278PubMed
25.
go back to reference Gunne HJ, Wall AK (1985) The effect of new complete dentures on mastication and dietary intake. Acta Odontol Scand 43:257–268PubMed Gunne HJ, Wall AK (1985) The effect of new complete dentures on mastication and dietary intake. Acta Odontol Scand 43:257–268PubMed
Metadata
Title
Quantification of oxidative metabolism in masseter muscle of denture wearers
Authors
A. Fujii
T. Shinogaya
S. Toda
I. Hayakawa
Publication date
01-09-2005
Publisher
Springer-Verlag
Published in
Clinical Oral Investigations / Issue 3/2005
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-004-0300-5

Other articles of this Issue 3/2005

Clinical Oral Investigations 3/2005 Go to the issue

Calendar of Events

Calendar of Events