Skip to main content
Top
Published in: Acta Diabetologica 1/2018

Open Access 01-01-2018 | Original Article

Pancreatic imaging using an antibody fragment targeting the zinc transporter type 8: a direct comparison with radio-iodinated Exendin-4

Authors: Olof Eriksson, Olle Korsgren, Ram Kumar Selvaraju, Marjorie Mollaret, Yann de Boysson, Fabrice Chimienti, Mohamed Altai

Published in: Acta Diabetologica | Issue 1/2018

Login to get access

Abstract

Aim

The zinc transporter 8 (ZnT8) has been suggested as a suitable target for non-invasive visualization of the functional pancreatic beta cell mass, due to both its pancreatic beta cell restricted expression and tight involvement in insulin secretion.

Methods

In order to examine the potential of ZnT8 as a surrogate target for beta cell mass, we performed mRNA transcription analysis in pancreatic compartments. A novel ZnT8 targeting antibody fragment Ab31 was radiolabeled with iodine-125, and evaluated by in vitro autoradiography in insulinoma and pancreas as well as by in vivo biodistribution. The evaluation was performed in a direct comparison with radio-iodinated Exendin-4.

Results

Transcription of the ZnT8 mRNA was higher in islets of Langerhans compared to exocrine tissue. Ab31 targeted ZnT8 in the cytosol and on the plasma membrane with 108 nM affinity. Ab31 was successfully radiolabeled with iodine-125 with high yield and > 95% purity. [125I]Ab31 binding to insulinoma and pancreas was higher than for [125I]Exendin-4, but could only by partially competed away by 200 nM Ab31 in excess. The in vivo uptake of [125I]Ab31 was higher than [125I]Exendin-4 in most tissues, mainly due to slower clearance from blood.

Conclusions

We report a first-in-class ZnT8 imaging ligand for pancreatic imaging. Development with respect to ligand miniaturization and radionuclide selection is required for further progress. Transcription analysis indicates ZnT8 as a suitable target for visualization of the human endocrine pancreas.
Literature
2.
go back to reference Laurent D, Vinet L, Lamprianou S et al (2016) Pancreatic β-cell imaging in humans: fiction or option? Diabetes Obes Metab 18(1):6–15CrossRefPubMed Laurent D, Vinet L, Lamprianou S et al (2016) Pancreatic β-cell imaging in humans: fiction or option? Diabetes Obes Metab 18(1):6–15CrossRefPubMed
3.
go back to reference Nicolson TJ, Bellomo EA, Wijesekara N et al (2009) Insulin storage and glucose homeostasis in mice null for the granule zinc transporter ZnT8 and studies of the type 2 diabetes-associated variants. Diabetes 58(9):2070–2083CrossRefPubMedPubMedCentral Nicolson TJ, Bellomo EA, Wijesekara N et al (2009) Insulin storage and glucose homeostasis in mice null for the granule zinc transporter ZnT8 and studies of the type 2 diabetes-associated variants. Diabetes 58(9):2070–2083CrossRefPubMedPubMedCentral
4.
go back to reference Chimienti F, Favier A, Seve M (2005) ZnT-8, a pancreatic beta-cell-specific zinc transporter. Biometals 18(4):313–317CrossRefPubMed Chimienti F, Favier A, Seve M (2005) ZnT-8, a pancreatic beta-cell-specific zinc transporter. Biometals 18(4):313–317CrossRefPubMed
5.
go back to reference Chimienti F, Devergnas S, Pattou F et al (2006) In vivo expression and functional characterization of the zinc transporter ZnT8 in glucose-induced insulin secretion. J Cell Sci 119(Pt 20):4199–4206CrossRefPubMed Chimienti F, Devergnas S, Pattou F et al (2006) In vivo expression and functional characterization of the zinc transporter ZnT8 in glucose-induced insulin secretion. J Cell Sci 119(Pt 20):4199–4206CrossRefPubMed
7.
go back to reference Wenzlau JM, Juhl K, Yu L et al (2007) The cation efflux transporter ZnT8 (Slc30A8) is a major autoantigen in human type 1 diabetes. Proc Natl Acad Sci USA 104:17040–17045CrossRefPubMedPubMedCentral Wenzlau JM, Juhl K, Yu L et al (2007) The cation efflux transporter ZnT8 (Slc30A8) is a major autoantigen in human type 1 diabetes. Proc Natl Acad Sci USA 104:17040–17045CrossRefPubMedPubMedCentral
8.
go back to reference Sladek R, Rocheleau G, Rung J et al (2007) A genome-wide association study identifies novel risk loci for type 2 diabetes. Nature 445(7130):881–885CrossRefPubMed Sladek R, Rocheleau G, Rung J et al (2007) A genome-wide association study identifies novel risk loci for type 2 diabetes. Nature 445(7130):881–885CrossRefPubMed
9.
go back to reference Saxena R, Voight BF, Lyssenko V et al (2007) Genome-wide association analysis identifies loci for type 2 diabetes and triglyceride levels. Science 316(5829):1331–1336CrossRefPubMed Saxena R, Voight BF, Lyssenko V et al (2007) Genome-wide association analysis identifies loci for type 2 diabetes and triglyceride levels. Science 316(5829):1331–1336CrossRefPubMed
10.
go back to reference Murgia C, Devirgiliis C, Mancini E, Donadel G, Zalewski P, Perozzi G (2009) Diabetes-linked zinc transporter ZnT8 is a homodimeric protein expressed by distinct rodent endocrine cell types in the pancreas and other glands. Nutr Metab Cardiovasc Dis 19:431–439CrossRefPubMed Murgia C, Devirgiliis C, Mancini E, Donadel G, Zalewski P, Perozzi G (2009) Diabetes-linked zinc transporter ZnT8 is a homodimeric protein expressed by distinct rodent endocrine cell types in the pancreas and other glands. Nutr Metab Cardiovasc Dis 19:431–439CrossRefPubMed
14.
go back to reference Trapnell C, Williams BA, Pertea G et al (2010) Transcript assembly and quantification by RNA-Seq reveals unannotated transcripts and isoform switching during cell differentiation. Nat Biotechnol 28:511–515CrossRefPubMedPubMedCentral Trapnell C, Williams BA, Pertea G et al (2010) Transcript assembly and quantification by RNA-Seq reveals unannotated transcripts and isoform switching during cell differentiation. Nat Biotechnol 28:511–515CrossRefPubMedPubMedCentral
15.
19.
go back to reference Béhé M, Gotthardt M, Behr TM (2006) Radioiodination of proteins and peptides. In: Celis JE (ed) Cell biology: a laboratory handbook, vol 1, 3rd edn. Elsevier Academic Press, New York, pp 149–154CrossRef Béhé M, Gotthardt M, Behr TM (2006) Radioiodination of proteins and peptides. In: Celis JE (ed) Cell biology: a laboratory handbook, vol 1, 3rd edn. Elsevier Academic Press, New York, pp 149–154CrossRef
20.
go back to reference Selvaraju RK, Velikyan I, Asplund V et al (2014) Pre-clinical evaluation of [68 Ga]Ga-DO3A-VS-Cys40-Exendin-4 for imaging of insulinoma. Nucl Med Biol 41:471–476CrossRefPubMed Selvaraju RK, Velikyan I, Asplund V et al (2014) Pre-clinical evaluation of [68 Ga]Ga-DO3A-VS-Cys40-Exendin-4 for imaging of insulinoma. Nucl Med Biol 41:471–476CrossRefPubMed
21.
go back to reference Eriksson O, Laughlin M, Brom M et al (2016) In vivo imaging of beta cells with radiotracers: state of the art, prospects and recommendations for development and use. Review. Diabetologia 59:1340–1349CrossRefPubMed Eriksson O, Laughlin M, Brom M et al (2016) In vivo imaging of beta cells with radiotracers: state of the art, prospects and recommendations for development and use. Review. Diabetologia 59:1340–1349CrossRefPubMed
22.
go back to reference Merchant M, Ma X, Maun HR et al (2013) Monovalent antibody design and mechanism of action of onartuzumab, a MET antagonist with anti-tumor activity as a therapeutic agent. Proc Natl Acad Sci USA 110(32):E2987–E2996CrossRefPubMedPubMedCentral Merchant M, Ma X, Maun HR et al (2013) Monovalent antibody design and mechanism of action of onartuzumab, a MET antagonist with anti-tumor activity as a therapeutic agent. Proc Natl Acad Sci USA 110(32):E2987–E2996CrossRefPubMedPubMedCentral
23.
go back to reference Pietersz GA, Patrick MR, Chester KA (1998) Preclinical characterization and in vivo imaging studies of an engineered recombinant technetium-99 m-labeled metallothionein-containing anti-carcinoembryonic antigen single-chain antibody. J Nucl Med 39(1):47–56PubMed Pietersz GA, Patrick MR, Chester KA (1998) Preclinical characterization and in vivo imaging studies of an engineered recombinant technetium-99 m-labeled metallothionein-containing anti-carcinoembryonic antigen single-chain antibody. J Nucl Med 39(1):47–56PubMed
24.
go back to reference Hampe CS, Wallen AR, Schlosser M, Ziegler M, Sweet IR (2005) Quantitative evaluation of a monoclonal antibody and its fragment as potential markers for pancreatic beta cell mass. Exp Clin Endocrinol Diabetes 113(7):381–387CrossRefPubMed Hampe CS, Wallen AR, Schlosser M, Ziegler M, Sweet IR (2005) Quantitative evaluation of a monoclonal antibody and its fragment as potential markers for pancreatic beta cell mass. Exp Clin Endocrinol Diabetes 113(7):381–387CrossRefPubMed
25.
go back to reference Holst B, Egerod KL, Jin C et al (2009) G protein-coupled receptor 39 deficiency is associated with pancreatic islet dysfunction. Endocrinology 150(6):2577–2585CrossRefPubMedPubMedCentral Holst B, Egerod KL, Jin C et al (2009) G protein-coupled receptor 39 deficiency is associated with pancreatic islet dysfunction. Endocrinology 150(6):2577–2585CrossRefPubMedPubMedCentral
26.
go back to reference Al-Hasani K, Pfeifer A, Courtney M et al (2013) Adult duct-lining cells can reprogram into β-like cells able to counter repeated cycles of toxin-induced diabetes. Dev Cell 26(1):86–100CrossRefPubMed Al-Hasani K, Pfeifer A, Courtney M et al (2013) Adult duct-lining cells can reprogram into β-like cells able to counter repeated cycles of toxin-induced diabetes. Dev Cell 26(1):86–100CrossRefPubMed
28.
go back to reference Murgia C, Devirgiliis C, Mancini E, Donadel G, Zalewski P, Perozzi G (2009) Diabetes-linked zinc transporter ZnT8 is a homodimeric protein expressed by distinct rodent endocrine cell types in the pancreas and other glands. Nutr Metab Cardiovasc Dis 19(6):431–439CrossRefPubMed Murgia C, Devirgiliis C, Mancini E, Donadel G, Zalewski P, Perozzi G (2009) Diabetes-linked zinc transporter ZnT8 is a homodimeric protein expressed by distinct rodent endocrine cell types in the pancreas and other glands. Nutr Metab Cardiovasc Dis 19(6):431–439CrossRefPubMed
29.
go back to reference Pimm MV, Gribben SJ (1994) Prevention of renal tubule re-absorption of radiometal (indium-111) labelled Fab fragment of a monoclonal antibody in mice by systemic administration of lysine. Eur J Nucl Meal 21:663–665CrossRef Pimm MV, Gribben SJ (1994) Prevention of renal tubule re-absorption of radiometal (indium-111) labelled Fab fragment of a monoclonal antibody in mice by systemic administration of lysine. Eur J Nucl Meal 21:663–665CrossRef
30.
go back to reference Selvaraju RK, Bulenga TN, Espes D et al (2015) Dosimetry of [68Ga]Ga-DO3A-VS-Cys40-Exendin-4 in rodents, pigs, non-human primates and human—repeated scanning in human is possible. Am J Nucl Med Mol Imaging 5:259–269PubMedPubMedCentral Selvaraju RK, Bulenga TN, Espes D et al (2015) Dosimetry of [68Ga]Ga-DO3A-VS-Cys40-Exendin-4 in rodents, pigs, non-human primates and human—repeated scanning in human is possible. Am J Nucl Med Mol Imaging 5:259–269PubMedPubMedCentral
31.
go back to reference Mikkola K, Yim CB, Lehtiniemi P et al (2016) Low kidney uptake of GLP-1R-targeting, beta cell-specific PET tracer, 18F-labeled [Nle14, Lys40]exendin-4 analog, shows promise for clinical imaging. EJNMMI Res 6:91CrossRefPubMedPubMedCentral Mikkola K, Yim CB, Lehtiniemi P et al (2016) Low kidney uptake of GLP-1R-targeting, beta cell-specific PET tracer, 18F-labeled [Nle14, Lys40]exendin-4 analog, shows promise for clinical imaging. EJNMMI Res 6:91CrossRefPubMedPubMedCentral
32.
go back to reference Läppchen T, Tönnesmann R, Eersels J, Meyer PT, Maecke HR, Rylova SN (2017) Radioiodinated Exendin-4 is superior to the radiometal-labelled glucagon-like peptide-1 receptor probes overcoming their high kidney uptake. PLoS ONE 12(1):e0170435CrossRefPubMedPubMedCentral Läppchen T, Tönnesmann R, Eersels J, Meyer PT, Maecke HR, Rylova SN (2017) Radioiodinated Exendin-4 is superior to the radiometal-labelled glucagon-like peptide-1 receptor probes overcoming their high kidney uptake. PLoS ONE 12(1):e0170435CrossRefPubMedPubMedCentral
33.
go back to reference Jodal A, Lankat-Buttgereit B, Brom M, Schibli R, Béhé M (2014) A comparison of three (67/68)Ga-labelled Exendin-4 derivatives for β-cell imaging on the GLP-1 receptor: the influence of the conjugation site of NODAGA as chelator. EJNMMI Res 22(4):31CrossRef Jodal A, Lankat-Buttgereit B, Brom M, Schibli R, Béhé M (2014) A comparison of three (67/68)Ga-labelled Exendin-4 derivatives for β-cell imaging on the GLP-1 receptor: the influence of the conjugation site of NODAGA as chelator. EJNMMI Res 22(4):31CrossRef
34.
go back to reference Brom M, Joosten L, Oyen WJ, Gotthardt M, Boerman OC (2012) Radiolabelled GLP-1 analogues for in vivo targeting of insulinomas. Contrast Media Mol Imaging 7(2):160–166CrossRefPubMedPubMedCentral Brom M, Joosten L, Oyen WJ, Gotthardt M, Boerman OC (2012) Radiolabelled GLP-1 analogues for in vivo targeting of insulinomas. Contrast Media Mol Imaging 7(2):160–166CrossRefPubMedPubMedCentral
35.
go back to reference Huang Q, Merriman C, Zhang H, Fu D (2017) Coupling of insulin secretion and display of a Granule-resident Zinc Transporter ZnT8 on the surface of pancreatic beta cells. J Biol Chem 292(10):4034–4043CrossRefPubMed Huang Q, Merriman C, Zhang H, Fu D (2017) Coupling of insulin secretion and display of a Granule-resident Zinc Transporter ZnT8 on the surface of pancreatic beta cells. J Biol Chem 292(10):4034–4043CrossRefPubMed
Metadata
Title
Pancreatic imaging using an antibody fragment targeting the zinc transporter type 8: a direct comparison with radio-iodinated Exendin-4
Authors
Olof Eriksson
Olle Korsgren
Ram Kumar Selvaraju
Marjorie Mollaret
Yann de Boysson
Fabrice Chimienti
Mohamed Altai
Publication date
01-01-2018
Publisher
Springer Milan
Published in
Acta Diabetologica / Issue 1/2018
Print ISSN: 0940-5429
Electronic ISSN: 1432-5233
DOI
https://doi.org/10.1007/s00592-017-1059-x

Other articles of this Issue 1/2018

Acta Diabetologica 1/2018 Go to the issue