Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 1/2012

01-01-2012 | General Review

The case for the metal-backed glenoid design in total anatomical shoulder arthroplasty

Authors: Denis C. Katz, P. Sauzières, P. Valenti, J. Kany

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 1/2012

Login to get access

Abstract

After 38 years of unchallenged reign of cemented full polyethylene glenoid implants, the main problem of anatomical shoulder arthroplasty is still glenoid loosening, also the main cause of failure. A certain concern regarding uncemented metal back components in total anatomical shoulder arthroplasty has developed, due to problems evoked in the literature. This work is a comprehensive bibliographical review of the different clinical and biomechanical studies of noncemented glenoid implants. Those publications often showed a high rate of failure of uncemented glenoid implants, but their arguments appeared often theoretical or based on old and/or nonadapted devices. In conclusion, the authors emphasise that research on new designs of metal back components needs to go on.
Literature
1.
go back to reference Bohsali KJ, Wirth MA, Rockwood CA (2006) Complications of total shoulder arthroplasty. J Bone Joint Surg 88:2279–2292PubMedCrossRef Bohsali KJ, Wirth MA, Rockwood CA (2006) Complications of total shoulder arthroplasty. J Bone Joint Surg 88:2279–2292PubMedCrossRef
2.
go back to reference Brems J (1993) The glenoid component in total shoulder arthroplasty. J Should Elbow Surg 2:47–54CrossRef Brems J (1993) The glenoid component in total shoulder arthroplasty. J Should Elbow Surg 2:47–54CrossRef
3.
go back to reference Neer CS (1974) Replacement arthroplasty for glenohumeral osteoarthritis. J Bone Joint Surg 56A:1–13 Neer CS (1974) Replacement arthroplasty for glenohumeral osteoarthritis. J Bone Joint Surg 56A:1–13
4.
go back to reference Cheung EV, Sperling JW, Cofield RH (2008) Revision shoulder arthroplasty for glenoid component loosening. J Shoulder Elbow Surg 17:371–375PubMedCrossRef Cheung EV, Sperling JW, Cofield RH (2008) Revision shoulder arthroplasty for glenoid component loosening. J Shoulder Elbow Surg 17:371–375PubMedCrossRef
5.
go back to reference Sperling JW, Rowland CM (1998) Neer hemiarthroplasty and Neer total shoulder arthroplasty in patients 50 years old or less. Long-term results. J Bone Joint Surg Am 80:464–473PubMed Sperling JW, Rowland CM (1998) Neer hemiarthroplasty and Neer total shoulder arthroplasty in patients 50 years old or less. Long-term results. J Bone Joint Surg Am 80:464–473PubMed
6.
go back to reference Torchia ME, Cofield RH, Settergren CR (1997) Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Should Elbow Surg 6:495–505CrossRef Torchia ME, Cofield RH, Settergren CR (1997) Total shoulder arthroplasty with the Neer prosthesis: long-term results. J Should Elbow Surg 6:495–505CrossRef
7.
go back to reference Lazarus MD, Jensen KL, Southworth C, Matsen FA (2002) The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am 84:1174–1182PubMed Lazarus MD, Jensen KL, Southworth C, Matsen FA (2002) The radiographic evaluation of keeled and pegged glenoid component insertion. J Bone Joint Surg Am 84:1174–1182PubMed
8.
go back to reference Norris TR, Iannotti JP (2002) Functional outcome after shoulder arthroplasty for primary osteoarthritis. A multicenter study. J Should Elbow Surg 11:130–135CrossRef Norris TR, Iannotti JP (2002) Functional outcome after shoulder arthroplasty for primary osteoarthritis. A multicenter study. J Should Elbow Surg 11:130–135CrossRef
9.
go back to reference Walch G, Edwards TB, Boulahia A et al (2002) The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: results of a multicenter study. J Bone Joint Surg Am 84:2186–2191PubMed Walch G, Edwards TB, Boulahia A et al (2002) The influence of glenohumeral prosthetic mismatch on glenoid radiolucent lines: results of a multicenter study. J Bone Joint Surg Am 84:2186–2191PubMed
10.
go back to reference Godenèche A, Boileau P, Favard L, Le Huec JC, Lévigne C, Nové-Josserand L, Walch G, Edwards B (2002) Prosthetic replacement in the treatment of osteoarthritis of the shoulder: early results of 268 cases. J Should Elbow Surg 11:11–18CrossRef Godenèche A, Boileau P, Favard L, Le Huec JC, Lévigne C, Nové-Josserand L, Walch G, Edwards B (2002) Prosthetic replacement in the treatment of osteoarthritis of the shoulder: early results of 268 cases. J Should Elbow Surg 11:11–18CrossRef
11.
go back to reference Buckingham BP, Parson M, Campbell B, Titelman RM, Smith KL, Matsen FA (2005) Patient functional self-assessment in late glenoid component failure at 3–11 years after total shoulder arthroplasty. J Should Elbow Surg 14:368–374CrossRef Buckingham BP, Parson M, Campbell B, Titelman RM, Smith KL, Matsen FA (2005) Patient functional self-assessment in late glenoid component failure at 3–11 years after total shoulder arthroplasty. J Should Elbow Surg 14:368–374CrossRef
12.
go back to reference Hasan SS, Leith JM, Campbell B, Kapil R, Smith KL, Matsen FA (2002) Characteristics of unsatisfactory shoulder arthroplasties. J Should Elbow Surg 11:431–441CrossRef Hasan SS, Leith JM, Campbell B, Kapil R, Smith KL, Matsen FA (2002) Characteristics of unsatisfactory shoulder arthroplasties. J Should Elbow Surg 11:431–441CrossRef
13.
go back to reference Kelleher IM, Cofield RH, Becker DA, Beabout JW (1992) Fluoroscopically positioned radiographs of total shoulder arthroplasty. J Should Elbow Surg 1:306–311CrossRef Kelleher IM, Cofield RH, Becker DA, Beabout JW (1992) Fluoroscopically positioned radiographs of total shoulder arthroplasty. J Should Elbow Surg 1:306–311CrossRef
14.
go back to reference Havig MT, Kumar A, Carpenter W, Seiler JG (1997) Assessment of radiolucent lines about the glenoid. J Bone Joint Surg 79A(3):428–432 Havig MT, Kumar A, Carpenter W, Seiler JG (1997) Assessment of radiolucent lines about the glenoid. J Bone Joint Surg 79A(3):428–432
15.
go back to reference Sneppen O, Fruensgaard S, Johannsen HV, Olsen BS, Sojbjerg JO, Andersen NH (1996) Total shoulder replacement in rheumatoid arthritis: proximal migration and loosening. J Should Elbow Surg 5:47–52CrossRef Sneppen O, Fruensgaard S, Johannsen HV, Olsen BS, Sojbjerg JO, Andersen NH (1996) Total shoulder replacement in rheumatoid arthritis: proximal migration and loosening. J Should Elbow Surg 5:47–52CrossRef
16.
go back to reference Neer CS (1990) Glenohumeral arthroplasty. In: Neer R (ed) Shoulder reconstruction. Saunders, Philadelphia, pp 220–260 Neer CS (1990) Glenohumeral arthroplasty. In: Neer R (ed) Shoulder reconstruction. Saunders, Philadelphia, pp 220–260
17.
go back to reference Rodosky MW, Weinstein DM, Pollock RG, Flatow EL, Bigliani LU, Neer CS (1995) On the rarity of glenoid component failure. J Should Elbow Surg 4(1):S13CrossRef Rodosky MW, Weinstein DM, Pollock RG, Flatow EL, Bigliani LU, Neer CS (1995) On the rarity of glenoid component failure. J Should Elbow Surg 4(1):S13CrossRef
18.
go back to reference Cofield RH (1984) Total shoulder arthroplasty with the Neer prosthesis. J Bone Joint Surg 66:899–906PubMed Cofield RH (1984) Total shoulder arthroplasty with the Neer prosthesis. J Bone Joint Surg 66:899–906PubMed
19.
go back to reference Neer CS, Morrison DS (1988) Glenoid bone grafting in total shoulder arthroplasty. J Bone Joint Surg 70A:1154–1162 Neer CS, Morrison DS (1988) Glenoid bone grafting in total shoulder arthroplasty. J Bone Joint Surg 70A:1154–1162
20.
go back to reference Tammachote N, Sperling JW, Vathana T, Cofield RH, Harmsen WS, Schleck CD (2009) Long-term results of cemented metal-backed glenoid components for osteoarthritis of the shoulder. J Bone Joint Surg Am 91:160–166PubMedCrossRef Tammachote N, Sperling JW, Vathana T, Cofield RH, Harmsen WS, Schleck CD (2009) Long-term results of cemented metal-backed glenoid components for osteoarthritis of the shoulder. J Bone Joint Surg Am 91:160–166PubMedCrossRef
21.
go back to reference Barrett WP, Thornhill TS, Thomas WH, Gebhart EM, Sledge CB (1989) Nonconstrained total shoulder arthroplasty in patients with polyarticular rheumatoid arthritis. J Arthroplast 1:91–96CrossRef Barrett WP, Thornhill TS, Thomas WH, Gebhart EM, Sledge CB (1989) Nonconstrained total shoulder arthroplasty in patients with polyarticular rheumatoid arthritis. J Arthroplast 1:91–96CrossRef
22.
go back to reference Brenner BC, Ferlic DC, Clayton ML, Dennis DA (1989) Survivorship of unconstrained total shoulder arthroplasty. J Bone Joint Surg Am 71:1289–1296PubMed Brenner BC, Ferlic DC, Clayton ML, Dennis DA (1989) Survivorship of unconstrained total shoulder arthroplasty. J Bone Joint Surg Am 71:1289–1296PubMed
23.
go back to reference Pearl MA (2005) Proximal humeral anatomy in shoulder arthroplasty: implications for prosthetic design and surgical technique. J Should Elbow Surg 14:99S–104SCrossRef Pearl MA (2005) Proximal humeral anatomy in shoulder arthroplasty: implications for prosthetic design and surgical technique. J Should Elbow Surg 14:99S–104SCrossRef
24.
go back to reference Iannotti JP, Gabriel JP, Schneck SL, Evans BG, Misra S (1992) The normal glohumeral relationships. J Bone Joint Surg 4:491–500 Iannotti JP, Gabriel JP, Schneck SL, Evans BG, Misra S (1992) The normal glohumeral relationships. J Bone Joint Surg 4:491–500
25.
go back to reference Rockwood CA Jr, Wirth MA (2002) Observation on retrieved hylamer glenoids in shoulder arthroplasty: problems associated with sterilization by gamma irradiation in air. J Should Elbow Surg 11:191–197CrossRef Rockwood CA Jr, Wirth MA (2002) Observation on retrieved hylamer glenoids in shoulder arthroplasty: problems associated with sterilization by gamma irradiation in air. J Should Elbow Surg 11:191–197CrossRef
26.
go back to reference Clayton ML, Ferlic DC, Jeffers PD (1982) Prosthetic arthroplasties of the shoulder. Clin Orthop 164:184PubMed Clayton ML, Ferlic DC, Jeffers PD (1982) Prosthetic arthroplasties of the shoulder. Clin Orthop 164:184PubMed
27.
go back to reference Zuckerman JD, Cofield RH (1986) Proximal humeral prosthetic replacement in glenohumeral arthritis (abstract). Presented at the meeting of the American shoulder and elbow surgery. New Orleans Zuckerman JD, Cofield RH (1986) Proximal humeral prosthetic replacement in glenohumeral arthritis (abstract). Presented at the meeting of the American shoulder and elbow surgery. New Orleans
28.
go back to reference Garstman GM, Roddey TS, Hammerman SM (2000) Shoulder arthroplasty with or without resurfacing of the glenoid in patients who have osteoarthritis. J Bone Joint Surg 1:26–34 Garstman GM, Roddey TS, Hammerman SM (2000) Shoulder arthroplasty with or without resurfacing of the glenoid in patients who have osteoarthritis. J Bone Joint Surg 1:26–34
29.
go back to reference Burkhead WZ, Hulton CSJ (1995) Biologic resurfacing of the glenoid with hemiarthoplasty of the shoulder. J Should Elbow Surg 4:263–270CrossRef Burkhead WZ, Hulton CSJ (1995) Biologic resurfacing of the glenoid with hemiarthoplasty of the shoulder. J Should Elbow Surg 4:263–270CrossRef
30.
go back to reference Rydholm U, Sjögren J (1993) Surface replacement of the humeral head in the rheumatoid shoulder. J Should Elbow Surg 2:286–295CrossRef Rydholm U, Sjögren J (1993) Surface replacement of the humeral head in the rheumatoid shoulder. J Should Elbow Surg 2:286–295CrossRef
31.
go back to reference Matsen FA, Bicknell RT, Lippitt SB (2007) Shoulder arthroplasty: the socket perspective. J Should Elbow Surg 16:241S–247SCrossRef Matsen FA, Bicknell RT, Lippitt SB (2007) Shoulder arthroplasty: the socket perspective. J Should Elbow Surg 16:241S–247SCrossRef
32.
go back to reference Williams GR, Abboud JA (2005) Total shoulder arthroplasty: glenoid component design. J Should Elbow Surg 14:122S–128SCrossRef Williams GR, Abboud JA (2005) Total shoulder arthroplasty: glenoid component design. J Should Elbow Surg 14:122S–128SCrossRef
33.
go back to reference Anglin C, Wyss UP, Nyffeler RW, Gerber C (2001) Loosening performance of cemented glenoid prosthesis design pairs. Clin Biomech 63:144–150CrossRef Anglin C, Wyss UP, Nyffeler RW, Gerber C (2001) Loosening performance of cemented glenoid prosthesis design pairs. Clin Biomech 63:144–150CrossRef
34.
go back to reference Roper BA, Paterson JMH, Day WH (1990) The roper-day total shoulder replacement. J Bone Joint Surg 72b:694–697 Roper BA, Paterson JMH, Day WH (1990) The roper-day total shoulder replacement. J Bone Joint Surg 72b:694–697
35.
go back to reference Wirth MA, Korvick DL, Basamania CJ et al (2001) Radiologic, mechanical and histological evaluation of 2 glenoid prosthesis designs in a canine model. J Should Elbow Surg 10:140–148CrossRef Wirth MA, Korvick DL, Basamania CJ et al (2001) Radiologic, mechanical and histological evaluation of 2 glenoid prosthesis designs in a canine model. J Should Elbow Surg 10:140–148CrossRef
36.
go back to reference Amstutz HC, Sew Hoy A, Clark IC (1981) Anatomic total shoulder arthroplasty. Clin Orthop 155:7PubMed Amstutz HC, Sew Hoy A, Clark IC (1981) Anatomic total shoulder arthroplasty. Clin Orthop 155:7PubMed
37.
go back to reference Murphy LA, Prendergast PJ, Resch H (2001) Structural analysis of an offset-keel design glenoid component compared with a center-keel design. J Should Elbow Surg 10:568–579CrossRef Murphy LA, Prendergast PJ, Resch H (2001) Structural analysis of an offset-keel design glenoid component compared with a center-keel design. J Should Elbow Surg 10:568–579CrossRef
38.
go back to reference Hsu HC, Wu JJ, Chen-Lo TH, Yang WH (1993) The influence of abductor lever arm changes after shoulder arthroplasty. J Should Elbow Surg 2:134–140CrossRef Hsu HC, Wu JJ, Chen-Lo TH, Yang WH (1993) The influence of abductor lever arm changes after shoulder arthroplasty. J Should Elbow Surg 2:134–140CrossRef
39.
go back to reference Iannotti JP, Spencer EE, Winter U, Deffenbaugh D, Williams G (2005) Prosthetic positioning in total shoulder arthroplasty. J Should Elbow Surg 97:111S–121SCrossRef Iannotti JP, Spencer EE, Winter U, Deffenbaugh D, Williams G (2005) Prosthetic positioning in total shoulder arthroplasty. J Should Elbow Surg 97:111S–121SCrossRef
40.
go back to reference Roberts SN, Foley APJ, Swallow HM, Wallace A, Coughlan DP (1991) The geometry of the humeral head and the design of prostheses. J Bone Joint Surg 73B:647–650 Roberts SN, Foley APJ, Swallow HM, Wallace A, Coughlan DP (1991) The geometry of the humeral head and the design of prostheses. J Bone Joint Surg 73B:647–650
41.
go back to reference Williams GR, Wong KL, Pepe MD, Tan V, Silverberg D, Ramsey ML, Karduna A, Iannotti JP (2001) The effect of articular malposition after total shoulder arthroplasty on glenohumeral translations, range of motion and subacromial impingement. J Should Elbow Surg 10:399–409CrossRef Williams GR, Wong KL, Pepe MD, Tan V, Silverberg D, Ramsey ML, Karduna A, Iannotti JP (2001) The effect of articular malposition after total shoulder arthroplasty on glenohumeral translations, range of motion and subacromial impingement. J Should Elbow Surg 10:399–409CrossRef
42.
go back to reference Hernigou P, Duparc F, Filali C (1995) Rétroversion humérale et prothèse d’épaule. Rev Chir Orthop 81:419–427PubMed Hernigou P, Duparc F, Filali C (1995) Rétroversion humérale et prothèse d’épaule. Rev Chir Orthop 81:419–427PubMed
43.
go back to reference Fukuda K, Chen CM, Cofield RH, Chao EYS (1988) Biomechanical analysis of stability and fixation strength of total shoulder prostheses. Orthopedics 1:141–149 Fukuda K, Chen CM, Cofield RH, Chao EYS (1988) Biomechanical analysis of stability and fixation strength of total shoulder prostheses. Orthopedics 1:141–149
44.
go back to reference Poppen NK, Walker PS (1978) Forces at the glenohumeral joint in abduction. Clin Orthop 135:165–170PubMed Poppen NK, Walker PS (1978) Forces at the glenohumeral joint in abduction. Clin Orthop 135:165–170PubMed
45.
go back to reference Francklin JL, Barrett WP, Jackins SE, Matsen FA (1988) Glenoid loosening in total shoulder arthroplasty-an association with rotator cuff deficiency. J Arthroplast 3:39–46CrossRef Francklin JL, Barrett WP, Jackins SE, Matsen FA (1988) Glenoid loosening in total shoulder arthroplasty-an association with rotator cuff deficiency. J Arthroplast 3:39–46CrossRef
46.
go back to reference Inman VT, Saunders JB, Abbot LC (1944) Observations on the function of the shoulder joint. J Bone Joint Surg 1(26):1 Inman VT, Saunders JB, Abbot LC (1944) Observations on the function of the shoulder joint. J Bone Joint Surg 1(26):1
47.
go back to reference Collins D, Tencer A, Sidles J, Matsen F (1992) Edge displacement and deformation of glenoid components in response to eccentric loading. The effect of preparation of the glenoid bone. J Bone Joint Surg 74A:501–507 Collins D, Tencer A, Sidles J, Matsen F (1992) Edge displacement and deformation of glenoid components in response to eccentric loading. The effect of preparation of the glenoid bone. J Bone Joint Surg 74A:501–507
48.
go back to reference Friedman RJ (1992) Glenohumeral translation after total shoulder arthroplasty. J Should Elbow Surg 1:312–316CrossRef Friedman RJ (1992) Glenohumeral translation after total shoulder arthroplasty. J Should Elbow Surg 1:312–316CrossRef
49.
go back to reference Neer CS, Watson KC, Stanton FJ (1982) Recent experience in total shoulder replacement. J Bone Joint Surg 3:319–336 Neer CS, Watson KC, Stanton FJ (1982) Recent experience in total shoulder replacement. J Bone Joint Surg 3:319–336
50.
go back to reference Harryman DT, Sidles JA, Harris SL, Lippitt SB, Matsen FA (1995) The effect of articular conformity and the size of the humeral head component on laxity and motion after glenohumeral arthroplasty. J Bone Joint Surg 77A(4):555–563 Harryman DT, Sidles JA, Harris SL, Lippitt SB, Matsen FA (1995) The effect of articular conformity and the size of the humeral head component on laxity and motion after glenohumeral arthroplasty. J Bone Joint Surg 77A(4):555–563
51.
go back to reference Couteau B, Mansat P, Estivalèzes E, Darmana R, Mansat M, Egan J (2001) Finite element analysis of the mechanical behaviour of a scapula implanted with a glenoid prosthesis. Clin Biomech 16:566–575CrossRef Couteau B, Mansat P, Estivalèzes E, Darmana R, Mansat M, Egan J (2001) Finite element analysis of the mechanical behaviour of a scapula implanted with a glenoid prosthesis. Clin Biomech 16:566–575CrossRef
52.
go back to reference Severt R, Thomas BJ, Tsenter MJ, Amstutz HC (1993) The influence of conformity and constraint on translational forces and frictional torque in total shoulder arthroplasty. Clin Orthop 292:151–158PubMed Severt R, Thomas BJ, Tsenter MJ, Amstutz HC (1993) The influence of conformity and constraint on translational forces and frictional torque in total shoulder arthroplasty. Clin Orthop 292:151–158PubMed
53.
go back to reference Terrier A, Büchler P, Farron A (2005) Bone-cement interface of the glenoid component: stress analysis for varying cement thickness. Clin Biomech 20:710–717CrossRef Terrier A, Büchler P, Farron A (2005) Bone-cement interface of the glenoid component: stress analysis for varying cement thickness. Clin Biomech 20:710–717CrossRef
54.
go back to reference Orr TE, Cater DR, Shurman DJ (1988) Stress analyses of glenoid component designs. Clin Orthop 232:217–224PubMed Orr TE, Cater DR, Shurman DJ (1988) Stress analyses of glenoid component designs. Clin Orthop 232:217–224PubMed
55.
go back to reference Cofield RH (1994) Uncemented total shoulder arthroplasty: a review. Clin Orthop 307:86–93PubMed Cofield RH (1994) Uncemented total shoulder arthroplasty: a review. Clin Orthop 307:86–93PubMed
56.
go back to reference Cofield RH, Daly P (1992) Total shoulder arthroplasty with a tissue ingrowth glenoid component. J Should Elbow Surg 1:77–85CrossRef Cofield RH, Daly P (1992) Total shoulder arthroplasty with a tissue ingrowth glenoid component. J Should Elbow Surg 1:77–85CrossRef
57.
go back to reference Cheung EV, Sperling JW, Cofield RH (2007) Polyethylene insert exchange for wear after total shoulder arthroplasty. J Should Elbow Surg 16:574–578CrossRef Cheung EV, Sperling JW, Cofield RH (2007) Polyethylene insert exchange for wear after total shoulder arthroplasty. J Should Elbow Surg 16:574–578CrossRef
58.
go back to reference Taunton MJ, McIntosh AL, Sperling JW, Cofield RH (2008) Total shoulder arthroplasty with a metal-backed bone-ingrowth glenoid component. J Bone Joint Surg Am 90:2180–2188PubMedCrossRef Taunton MJ, McIntosh AL, Sperling JW, Cofield RH (2008) Total shoulder arthroplasty with a metal-backed bone-ingrowth glenoid component. J Bone Joint Surg Am 90:2180–2188PubMedCrossRef
59.
go back to reference Wallace AL, Walsh WR, Sonnabend DH (1999) Dissociation of the glenoid component in cementless total shoulder arthroplasty. J Should Elbow Surg 8:81–84CrossRef Wallace AL, Walsh WR, Sonnabend DH (1999) Dissociation of the glenoid component in cementless total shoulder arthroplasty. J Should Elbow Surg 8:81–84CrossRef
60.
go back to reference Wallace AL, Phillips RL, Mac Dougal GA, Walsh WR, Sonnabend DH (1999) Resurfacing of the glenoid in total shoulder arthroplasty. A comparison, at a mean of 5 years, of prostheses inserted with and without cement. J Bone Joint Surg Am 81:510–518PubMed Wallace AL, Phillips RL, Mac Dougal GA, Walsh WR, Sonnabend DH (1999) Resurfacing of the glenoid in total shoulder arthroplasty. A comparison, at a mean of 5 years, of prostheses inserted with and without cement. J Bone Joint Surg Am 81:510–518PubMed
61.
go back to reference Thomazeau H, Abdallah A, Gedouin JE, Lambotte JC, Langlais F (2004) Prothèse de Cofield scellée. Etude d’une cohorte de 15 cas à 10 ans de recul moyen. Ann Orthop Ouest 36:710–714 Thomazeau H, Abdallah A, Gedouin JE, Lambotte JC, Langlais F (2004) Prothèse de Cofield scellée. Etude d’une cohorte de 15 cas à 10 ans de recul moyen. Ann Orthop Ouest 36:710–714
62.
go back to reference Walch G, Boulahia A, Boileau P, Kempf JF et al (1998) Primary glenohumeral osteoarthritis: clinical and radiographic classification. Acta Orthop Belg 64(Suppl 2):46–52PubMed Walch G, Boulahia A, Boileau P, Kempf JF et al (1998) Primary glenohumeral osteoarthritis: clinical and radiographic classification. Acta Orthop Belg 64(Suppl 2):46–52PubMed
63.
go back to reference McNab I, English TE (1976) Development of a glenohumeral arthroplasty for a severely destroyed shoulder joint. J Bone Joint Surg 58B:137 McNab I, English TE (1976) Development of a glenohumeral arthroplasty for a severely destroyed shoulder joint. J Bone Joint Surg 58B:137
64.
go back to reference Faludi DD, Weiland AJ (1983) Cementless total shoulder arthroplasty: preliminary experience with 13 cases. Orthopaedics 4:431–437 Faludi DD, Weiland AJ (1983) Cementless total shoulder arthroplasty: preliminary experience with 13 cases. Orthopaedics 4:431–437
65.
go back to reference McElwain JP, English E (1987) The early results of porous coated total shoulder arthroplasty. Clin Orthop 218:217–224PubMed McElwain JP, English E (1987) The early results of porous coated total shoulder arthroplasty. Clin Orthop 218:217–224PubMed
66.
go back to reference Martin SD, Zurakowski D, Thornhill T (2005) Uncemented glenoid component in total shoulder arthroplasty. J Bone Joint Surg 87:1284–1292PubMedCrossRef Martin SD, Zurakowski D, Thornhill T (2005) Uncemented glenoid component in total shoulder arthroplasty. J Bone Joint Surg 87:1284–1292PubMedCrossRef
67.
go back to reference Burkhead WZ (1995) Cementless shoulder arthroplasty. In: Friedman RJ (ed) Arthroplasty of the shoulder. Thieme medical, New York, pp 281–309 Burkhead WZ (1995) Cementless shoulder arthroplasty. In: Friedman RJ (ed) Arthroplasty of the shoulder. Thieme medical, New York, pp 281–309
68.
go back to reference Boileau P, Avidor C, Krishnan SG et al (2002) Cemented polyethylene versus uncemented metal-back glenoid component in total shoulder arthroplasty: a prospective, double blind, randomized study. J Should Elbow Surg 11:351–359CrossRef Boileau P, Avidor C, Krishnan SG et al (2002) Cemented polyethylene versus uncemented metal-back glenoid component in total shoulder arthroplasty: a prospective, double blind, randomized study. J Should Elbow Surg 11:351–359CrossRef
69.
go back to reference Wirth MA, Agrawal CM, Mabrey JD et al (1999) Isolation and characterization of polyethylene wear debris associated with osteolysis following total shoulder arthroplasty. J Bone Joint Surg Am 81:29–37PubMed Wirth MA, Agrawal CM, Mabrey JD et al (1999) Isolation and characterization of polyethylene wear debris associated with osteolysis following total shoulder arthroplasty. J Bone Joint Surg Am 81:29–37PubMed
70.
go back to reference Wirth MA, Basamania C, Rockwood CA (1994) Fixation of glenoid component: keel versus pegs. Oper Tech Orthop 4:218–225CrossRef Wirth MA, Basamania C, Rockwood CA (1994) Fixation of glenoid component: keel versus pegs. Oper Tech Orthop 4:218–225CrossRef
71.
go back to reference Mathur K, Fourie B, Clement N, Stirrat AN (2005) The metal backed glenoid component in total shoulder arthroplasty-minimum 5 years follow-up. J Bone Joint Surg 87B(Suppl 2):160–161 Mathur K, Fourie B, Clement N, Stirrat AN (2005) The metal backed glenoid component in total shoulder arthroplasty-minimum 5 years follow-up. J Bone Joint Surg 87B(Suppl 2):160–161
72.
go back to reference Friedman RJ, Laberge M, Dooley RL et al (1992) Finite element modelling of the glenoid component. Effect of design parameters on stress distribution. J Should Elbow Surg 1:261–270CrossRef Friedman RJ, Laberge M, Dooley RL et al (1992) Finite element modelling of the glenoid component. Effect of design parameters on stress distribution. J Should Elbow Surg 1:261–270CrossRef
73.
go back to reference Stone KD, Grabowski JJ, Cofield RH, Morrey BF, An KN (1999) Stress analysis of glenoid components in total shoulder arthroplasty. J Should Elbow Surg 8:15–18CrossRef Stone KD, Grabowski JJ, Cofield RH, Morrey BF, An KN (1999) Stress analysis of glenoid components in total shoulder arthroplasty. J Should Elbow Surg 8:15–18CrossRef
74.
go back to reference Copeland S (1990) Cementless total shoulder replacement. In: Post M, Morrey BF, Hawkins RJ (eds) Surgery of the shoulder. Mosby, St. Louis, pp 289–297 Copeland S (1990) Cementless total shoulder replacement. In: Post M, Morrey BF, Hawkins RJ (eds) Surgery of the shoulder. Mosby, St. Louis, pp 289–297
75.
go back to reference Feldman AY, Bunker TD (1999) Rotational dissociation of glenoid components in a total shoulder arthroplasty. J Should Elbow Surg 8:279–280CrossRef Feldman AY, Bunker TD (1999) Rotational dissociation of glenoid components in a total shoulder arthroplasty. J Should Elbow Surg 8:279–280CrossRef
76.
go back to reference Levy O, Copeland SA (2001) Rotational dissociation of glenoid components in a total shoulder prosthesis: an indication that saggital torque forces may be important in glenoid component design (letter). J Should Elbow Surg 10:197CrossRef Levy O, Copeland SA (2001) Rotational dissociation of glenoid components in a total shoulder prosthesis: an indication that saggital torque forces may be important in glenoid component design (letter). J Should Elbow Surg 10:197CrossRef
77.
go back to reference Swieszkowski W, Bednarz P, Prendergast PJ (2003) Contact stresses in the glenoid component in total shoulder arthroplasty. Proc Inst Mech Eng 217:49–57 Swieszkowski W, Bednarz P, Prendergast PJ (2003) Contact stresses in the glenoid component in total shoulder arthroplasty. Proc Inst Mech Eng 217:49–57
78.
go back to reference Hopkins AR, Hansen UN, Amis AA, Knight L, Taylor M, Levy O, Copeland SA (2007) Wear in the prosthetic shoulder: association with design parameters. J Biomech Eng 129(2):223–230PubMedCrossRef Hopkins AR, Hansen UN, Amis AA, Knight L, Taylor M, Levy O, Copeland SA (2007) Wear in the prosthetic shoulder: association with design parameters. J Biomech Eng 129(2):223–230PubMedCrossRef
79.
go back to reference Gupta S, van Dre Helm FC, Van Keulen F (2004) The possibilities of uncemented glenoid component. Clin Biomech 19:292–302CrossRef Gupta S, van Dre Helm FC, Van Keulen F (2004) The possibilities of uncemented glenoid component. Clin Biomech 19:292–302CrossRef
80.
go back to reference Karduna AR, Williams GR, Williams JL, Iannotti JP (1997) Glenohumeral joint translations before and after total shoulder arthroplasty. A study in cadavera. J Bone Joint Surg Am 79:1166–1174PubMed Karduna AR, Williams GR, Williams JL, Iannotti JP (1997) Glenohumeral joint translations before and after total shoulder arthroplasty. A study in cadavera. J Bone Joint Surg Am 79:1166–1174PubMed
81.
go back to reference Katz D, O’Toole G, Cogswell L, Valenti P, Sauzières P (2007) A history of the reverse shoulder prosthesis. Int J Should Surg 1:108–113CrossRef Katz D, O’Toole G, Cogswell L, Valenti P, Sauzières P (2007) A history of the reverse shoulder prosthesis. Int J Should Surg 1:108–113CrossRef
82.
go back to reference Steinmann SP, Cofield RH (2000) Bone grafting for glenoid deficiency in total shoulder replacement. J Should Elbow Surg 9:361–367CrossRef Steinmann SP, Cofield RH (2000) Bone grafting for glenoid deficiency in total shoulder replacement. J Should Elbow Surg 9:361–367CrossRef
83.
go back to reference Katz D, Valenti P, El Hadi A (2004) 14 cas de luxations invétérées de l’épaule traitées par arthroplastie. Réflexions pronostiques et thérapeutiques. Rev Chir Orthop 7(Suppl 6):2S–14S Katz D, Valenti P, El Hadi A (2004) 14 cas de luxations invétérées de l’épaule traitées par arthroplastie. Réflexions pronostiques et thérapeutiques. Rev Chir Orthop 7(Suppl 6):2S–14S
Metadata
Title
The case for the metal-backed glenoid design in total anatomical shoulder arthroplasty
Authors
Denis C. Katz
P. Sauzières
P. Valenti
J. Kany
Publication date
01-01-2012
Publisher
Springer-Verlag
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 1/2012
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-011-0796-8

Other articles of this Issue 1/2012

European Journal of Orthopaedic Surgery & Traumatology 1/2012 Go to the issue