Skip to main content
Top
Published in: European Spine Journal 12/2019

01-12-2019 | Implant Infection | Original Article

C-reactive protein misdiagnoses delayed postoperative spinal implant infections in patients with low-virulent microorganisms

Authors: Doruk Akgün, Justus Bürger, Matthias Pumberger, Michael Putzier

Published in: European Spine Journal | Issue 12/2019

Login to get access

Abstract

Purpose

C-reactive protein (CRP) has been shown to be a powerful parameter for detecting acute postoperative spinal implant infections (PSII) with a high sensitivity and specificity. However, little data are available on the performance of CRP in the diagnosis of delayed PSII. The aim of the current study was therefore to establish cutoff values for diagnosing delayed infection based on serum CRP.

Methods

All patients who underwent a revision surgery after instrumented spinal fusion from January 2013 through January 2016 were included. Demographic data, laboratory values, type of infection (including microbiological and pathological results), comorbidities and clinical manifestation were collected. The European Bone and Joint Infection Society criteria, proposed to diagnose periprosthetic joint infection, were used to diagnose PSII.

Results

A total of 257 patients were included. PSII was diagnosed in 61 patients, representing 24% of the study cohort. There was a significant difference in serum CRP levels between septic and aseptic cohorts (19.3 vs. 4.8 mg/l, p < 0.001). However, 26 patients (43%) from the PSII group had a normal (< 5 mg/l) serum CRP level prior to revision surgery. According to the ROC curve, a serum CRP threshold of 4.05 mg/l had a sensitivity of 64% and specificity of 68%. The most common isolated microorganism was Propionibacterium spp. followed by coagulase-negative staphylococci.

Conclusion

Serum CRP showed low sensitivity and specificity for diagnosis of delayed PSII, even after applying cutoffs optimized by using receiver operating curve analysis, because of the high incidence of low-virulent pathogens.

Graphical abstract

These slides can be retrieved under Electronic Supplementary Material.
Appendix
Available only for authorised users
Literature
1.
go back to reference Kowalski TJ, Berbari EF, Huddleston PM, Steckelberg JM, Mandrekar JN, Osmon DR (2007) The management and outcome of spinal implant infections: contemporary retrospective cohort study. Clin Infect Dis 44(7):913–920CrossRef Kowalski TJ, Berbari EF, Huddleston PM, Steckelberg JM, Mandrekar JN, Osmon DR (2007) The management and outcome of spinal implant infections: contemporary retrospective cohort study. Clin Infect Dis 44(7):913–920CrossRef
2.
go back to reference Piper KE, Fernandez-Sampedro M, Steckelberg KE et al (2010) C-reactive protein, erythrocyte sedimentation rate and orthopedic implant infection. PLoS ONE 5(2):e9358CrossRef Piper KE, Fernandez-Sampedro M, Steckelberg KE et al (2010) C-reactive protein, erythrocyte sedimentation rate and orthopedic implant infection. PLoS ONE 5(2):e9358CrossRef
3.
go back to reference Kang BU, Lee SH, Ahn Y, Choi WC, Choi YG (2010) Surgical site infection in spinal surgery: detection and management based on serial C-reactive protein measurements. J Neurosurg Spine 13(2):158–164CrossRef Kang BU, Lee SH, Ahn Y, Choi WC, Choi YG (2010) Surgical site infection in spinal surgery: detection and management based on serial C-reactive protein measurements. J Neurosurg Spine 13(2):158–164CrossRef
4.
go back to reference Mok JM, Pekmezci M, Piper SL et al (2008) Use of C-reactive protein after spinal surgery: comparison with erythrocyte sedimentation rate as predictor of early postoperative infectious complications. Spine 33(4):415–421CrossRef Mok JM, Pekmezci M, Piper SL et al (2008) Use of C-reactive protein after spinal surgery: comparison with erythrocyte sedimentation rate as predictor of early postoperative infectious complications. Spine 33(4):415–421CrossRef
5.
go back to reference Akgun D, Muller M, Perka C, Winkler T (2018) The serum level of C-reactive protein alone cannot be used for the diagnosis of prosthetic joint infections, especially in those caused by organisms of low virulence. Bone Joint J 100-B(11):1482–1486CrossRef Akgun D, Muller M, Perka C, Winkler T (2018) The serum level of C-reactive protein alone cannot be used for the diagnosis of prosthetic joint infections, especially in those caused by organisms of low virulence. Bone Joint J 100-B(11):1482–1486CrossRef
6.
go back to reference Hahn F, Zbinden R, Min K (2005) Late implant infections caused by Propionibacterium acnes in scoliosis surgery. Eur Spine J 14(8):783–788CrossRef Hahn F, Zbinden R, Min K (2005) Late implant infections caused by Propionibacterium acnes in scoliosis surgery. Eur Spine J 14(8):783–788CrossRef
7.
go back to reference Charlson ME, Pompei P, Ales KL, MacKenzie CR (1987) A new method of classifying prognostic comorbidity in longitudinal studies: development and validation. J Chronic Dis 40(5):373–383CrossRef Charlson ME, Pompei P, Ales KL, MacKenzie CR (1987) A new method of classifying prognostic comorbidity in longitudinal studies: development and validation. J Chronic Dis 40(5):373–383CrossRef
8.
go back to reference Bossuyt PM, Reitsma JB, Bruns DE et al (2003) Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative. Clin Chem Lab Med 41(1):68–73CrossRef Bossuyt PM, Reitsma JB, Bruns DE et al (2003) Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative. Clin Chem Lab Med 41(1):68–73CrossRef
9.
go back to reference von Elm E, Altman DG, Egger M et al (2007) The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Epidemiology 18(6):800–804CrossRef von Elm E, Altman DG, Egger M et al (2007) The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. Epidemiology 18(6):800–804CrossRef
10.
go back to reference Ochsner PEBO, Bodler PM, Broger I, Eich G, Hefti F, Maurer T, Nötzli H, Seiler S, Suva D, Trampuz A, Uckay I, Vogt M, Zimmerli W (2016) Infections of the musculoskeletal system: basic principles, prevention, diagnosis and treatment. Swiss Orthopaedics In-House Publisher, Grandvaux Ochsner PEBO, Bodler PM, Broger I, Eich G, Hefti F, Maurer T, Nötzli H, Seiler S, Suva D, Trampuz A, Uckay I, Vogt M, Zimmerli W (2016) Infections of the musculoskeletal system: basic principles, prevention, diagnosis and treatment. Swiss Orthopaedics In-House Publisher, Grandvaux
11.
go back to reference Krenn V, Morawietz L, Perino G et al (2014) Revised histopathological consensus classification of joint implant related pathology. Pathol Res Pract 210(12):779–786CrossRef Krenn V, Morawietz L, Perino G et al (2014) Revised histopathological consensus classification of joint implant related pathology. Pathol Res Pract 210(12):779–786CrossRef
12.
go back to reference Kim JI, Suh KT, Kim SJ, Lee JS (2010) Implant removal for the management of infection after instrumented spinal fusion. J Spinal Disord Tech 23(4):258–265CrossRef Kim JI, Suh KT, Kim SJ, Lee JS (2010) Implant removal for the management of infection after instrumented spinal fusion. J Spinal Disord Tech 23(4):258–265CrossRef
13.
go back to reference Chen SH, Lee CH, Huang KC, Hsieh PH, Tsai SY (2015) Postoperative wound infection after posterior spinal instrumentation: analysis of long-term treatment outcomes. Eur Spine J 24(3):561–570CrossRef Chen SH, Lee CH, Huang KC, Hsieh PH, Tsai SY (2015) Postoperative wound infection after posterior spinal instrumentation: analysis of long-term treatment outcomes. Eur Spine J 24(3):561–570CrossRef
14.
go back to reference Meredith DS, Kepler CK, Huang RC, Brause BD, Boachie-Adjei O (2012) Postoperative infections of the lumbar spine: presentation and management. Int Orthop 36(2):439–444CrossRef Meredith DS, Kepler CK, Huang RC, Brause BD, Boachie-Adjei O (2012) Postoperative infections of the lumbar spine: presentation and management. Int Orthop 36(2):439–444CrossRef
16.
go back to reference Tzeng A, Tzeng TH, Vasdev S et al (2015) Treating periprosthetic joint infections as biofilms: key diagnosis and management strategies. Diagn Microbiol Infect Dis 81(3):192–200CrossRef Tzeng A, Tzeng TH, Vasdev S et al (2015) Treating periprosthetic joint infections as biofilms: key diagnosis and management strategies. Diagn Microbiol Infect Dis 81(3):192–200CrossRef
17.
go back to reference Zimmerli W, Moser C (2012) Pathogenesis and treatment concepts of orthopaedic biofilm infections. FEMS Immunol Med Microbiol 65(2):158–168CrossRef Zimmerli W, Moser C (2012) Pathogenesis and treatment concepts of orthopaedic biofilm infections. FEMS Immunol Med Microbiol 65(2):158–168CrossRef
18.
go back to reference Bemer P, Corvec S, Tariel S et al (2008) Significance of Propionibacterium acnes-positive samples in spinal instrumentation. Spine 33(26):E971–E976CrossRef Bemer P, Corvec S, Tariel S et al (2008) Significance of Propionibacterium acnes-positive samples in spinal instrumentation. Spine 33(26):E971–E976CrossRef
19.
go back to reference Collins I, Wilson-MacDonald J, Chami G et al (2008) The diagnosis and management of infection following instrumented spinal fusion. Eur Spine J 17(3):445–450CrossRef Collins I, Wilson-MacDonald J, Chami G et al (2008) The diagnosis and management of infection following instrumented spinal fusion. Eur Spine J 17(3):445–450CrossRef
20.
go back to reference Lewkonia P, DiPaola C, Street J (2016) Incidence and risk of delayed surgical site infection following instrumented lumbar spine fusion. J Clin Neurosci 23:76–80CrossRef Lewkonia P, DiPaola C, Street J (2016) Incidence and risk of delayed surgical site infection following instrumented lumbar spine fusion. J Clin Neurosci 23:76–80CrossRef
21.
go back to reference Portillo ME, Salvado M, Alier A et al (2013) Prosthesis failure within 2 years of implantation is highly predictive of infection. Clin Orthop Relat Res 471(11):3672–3678CrossRef Portillo ME, Salvado M, Alier A et al (2013) Prosthesis failure within 2 years of implantation is highly predictive of infection. Clin Orthop Relat Res 471(11):3672–3678CrossRef
22.
go back to reference Ben-Galim P, Rand N, Giladi M et al (2006) Association between sciatica and microbial infection: true infection or culture contamination? Spine 31(21):2507–2509CrossRef Ben-Galim P, Rand N, Giladi M et al (2006) Association between sciatica and microbial infection: true infection or culture contamination? Spine 31(21):2507–2509CrossRef
Metadata
Title
C-reactive protein misdiagnoses delayed postoperative spinal implant infections in patients with low-virulent microorganisms
Authors
Doruk Akgün
Justus Bürger
Matthias Pumberger
Michael Putzier
Publication date
01-12-2019
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 12/2019
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-019-05889-3

Other articles of this Issue 12/2019

European Spine Journal 12/2019 Go to the issue