Skip to main content
Top
Published in: European Spine Journal 11/2017

01-11-2017 | Original Article

Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws

Authors: Virginie Cordemans, Ludovic Kaminski, Xavier Banse, Bernard G. Francq, Christine Detrembleur, Olivier Cartiaux

Published in: European Spine Journal | Issue 11/2017

Login to get access

Abstract

Purpose

The goals of this study were to assess the accuracy of pedicle screw insertion using an intraoperative cone beam computed tomography (CBCT) system, and to analyze the factors potentially influencing this accuracy.

Methods

Six hundred and ninety-five pedicle screws were inserted in 118 patients between October 2013 and March 2016. Screw insertion was performed using 2D-fluoroscopy or CBCT-based navigation. Accuracy was assessed in terms of breach and reposition. All the intraoperative CBCT scans, done after screw insertion, were reviewed to assess the accuracy of screw placement using two established classification systems: Gertzbein and Heary. Generalized linear mixed models were used to model the odds (95% CI) for a screw to lead to a breach according to the independent variables.

Results

The breach rate was 11.7% using the Gertzbein classification and 15.4% using the Heary classification. Seventeen screws (2.4%) were repositioned intraoperatively. The only factor affecting statistically the odds to have a breach was the indication of surgery. The patients with non-degenerative disease had a significantly higher risk of breach than those with degenerative disease.

Conclusion

Use of intraoperative CBCT as 2D-fluoroscopy or coupled with a navigation system for pedicle screw insertion is accurate in terms of breach occurrence and reposition. However, these rates depend on the classification or grading system used. Use of a navigation system does not decrease the risk of breach significantly. And the risk of breach is higher in non-degenerative conditions (trauma, scoliosis, infection, and malignancy disease) than in degenerative diseases.
Literature
1.
go back to reference Boucher HH (1959) A method of spinal fusion. J Bone Jt Surg 41B(2):248–259 Boucher HH (1959) A method of spinal fusion. J Bone Jt Surg 41B(2):248–259
3.
go back to reference Donohue ML, Moquin RR, Singla A, Calancie B (2014) Is in vivo manual palpation for the thoracic pedicle screw instrumentation reliable? J Neurosurg Spine 20:492–496CrossRefPubMed Donohue ML, Moquin RR, Singla A, Calancie B (2014) Is in vivo manual palpation for the thoracic pedicle screw instrumentation reliable? J Neurosurg Spine 20:492–496CrossRefPubMed
4.
go back to reference Jutte PC, Castelein RM (2002) Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11(6):594–598CrossRefPubMed Jutte PC, Castelein RM (2002) Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. Eur Spine J 11(6):594–598CrossRefPubMed
6.
go back to reference Tian NF, Huang QS, Zhou P et al (2011) Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 20(6):846–859CrossRefPubMed Tian NF, Huang QS, Zhou P et al (2011) Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies. Eur Spine J 20(6):846–859CrossRefPubMed
7.
go back to reference Lonjon N, Chan-Seng E, Costalat V, Bonnafoux B, Vassal M, Boetto J (2015) Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis. Eur Spine J. doi:10.1007/s00586-015-3758-8 Lonjon N, Chan-Seng E, Costalat V, Bonnafoux B, Vassal M, Boetto J (2015) Robot-assisted spine surgery: feasibility study through a prospective case-matched analysis. Eur Spine J. doi:10.​1007/​s00586-015-3758-8
8.
go back to reference Lamartina C, Cecchinato R, Fekete Z, Lipari A, Fiechter M, Berjano P (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J 24(Suppl 7):S937–S941CrossRef Lamartina C, Cecchinato R, Fekete Z, Lipari A, Fiechter M, Berjano P (2015) Pedicle screw placement accuracy in thoracic and lumbar spinal surgery with a patient-matched targeting guide: a cadaveric study. Eur Spine J 24(Suppl 7):S937–S941CrossRef
9.
go back to reference Richter PH, Yarboro S, Kraus M, Gebhard F (2015) One year orthopaedic trauma experience using an advanced interdisciplinary hybrid operating room. Injury 46(Suppl 4):S129–S134CrossRefPubMed Richter PH, Yarboro S, Kraus M, Gebhard F (2015) One year orthopaedic trauma experience using an advanced interdisciplinary hybrid operating room. Injury 46(Suppl 4):S129–S134CrossRefPubMed
10.
go back to reference Raftopoulos C, Waterkeyn F, Fomekong E, Duprez T (2012) Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy. Adv Tech Stand Neurosurg 38:75–93CrossRefPubMed Raftopoulos C, Waterkeyn F, Fomekong E, Duprez T (2012) Percutaneous pedicle screw implantation for refractory low back pain: from manual 2D to fully robotic intraoperative 2D/3D fluoroscopy. Adv Tech Stand Neurosurg 38:75–93CrossRefPubMed
11.
go back to reference Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15(1):11–14CrossRef Gertzbein SD, Robbins SE (1990) Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976) 15(1):11–14CrossRef
12.
go back to reference Heary RF, Bono CM, Black M (2004) Thoracic pedicle screws: postoperative computerized tomography scanning assessment. J Neurosurg 100(4 Suppl Spine):325–331PubMed Heary RF, Bono CM, Black M (2004) Thoracic pedicle screws: postoperative computerized tomography scanning assessment. J Neurosurg 100(4 Suppl Spine):325–331PubMed
13.
go back to reference Amato V, Giannachi L, Irace C, Corona C (2010) Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients. J Neurosurg Spine 12(3):306–313CrossRefPubMed Amato V, Giannachi L, Irace C, Corona C (2010) Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients. J Neurosurg Spine 12(3):306–313CrossRefPubMed
14.
go back to reference Motiei-Langroudi R, Sadeghian H (2015) Assessment of pedicle screw placement accuracy in thoracolumbosacral spine using freehand technique aided by lateral fluoroscopy: results of postoperative computed tomography in 114 patients. Spine J 15(4):700–704CrossRefPubMed Motiei-Langroudi R, Sadeghian H (2015) Assessment of pedicle screw placement accuracy in thoracolumbosacral spine using freehand technique aided by lateral fluoroscopy: results of postoperative computed tomography in 114 patients. Spine J 15(4):700–704CrossRefPubMed
15.
go back to reference Kotani Y, Abumi K, Ito M, Takahata M, Sudo H, Ohshima S, Minami A (2007) Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine (Phila Pa 1976) 32(14):1543–1550CrossRef Kotani Y, Abumi K, Ito M, Takahata M, Sudo H, Ohshima S, Minami A (2007) Accuracy analysis of pedicle screw placement in posterior scoliosis surgery: comparison between conventional fluoroscopic and computer-assisted technique. Spine (Phila Pa 1976) 32(14):1543–1550CrossRef
16.
go back to reference Ling JM, Dinesh SK, Pang BC et al (2013) Routine spinal navigation for thoracolumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy. J Clin Neurosci 21(3):493–498CrossRefPubMed Ling JM, Dinesh SK, Pang BC et al (2013) Routine spinal navigation for thoracolumbar pedicle screw insertion using the O-arm three-dimensional imaging system improves placement accuracy. J Clin Neurosci 21(3):493–498CrossRefPubMed
17.
go back to reference Scheufler KM, Franke J, Eckardt A, Dohmen H (2011) Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine. Neurosurgery 69(6):1307–1316CrossRefPubMed Scheufler KM, Franke J, Eckardt A, Dohmen H (2011) Accuracy of image-guided pedicle screw placement using intraoperative computed tomography-based navigation with automated referencing. Part II: thoracolumbar spine. Neurosurgery 69(6):1307–1316CrossRefPubMed
18.
go back to reference Kantelhardt SR, Martinez R, Baerwinkel S, Burger R, Giese A, Rohde V (2011) Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement. Eur Spine J 20(6):860–868CrossRefPubMedPubMedCentral Kantelhardt SR, Martinez R, Baerwinkel S, Burger R, Giese A, Rohde V (2011) Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement. Eur Spine J 20(6):860–868CrossRefPubMedPubMedCentral
19.
20.
go back to reference Parker S, McGirt M, Farber S et al (2011) Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68(1):170–178CrossRefPubMed Parker S, McGirt M, Farber S et al (2011) Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68(1):170–178CrossRefPubMed
21.
go back to reference Santos ER, Ledonio CG, Castro CA, Truong WH, Sembrano JN (2012) The accuracy of intraoperative O-arm images for the assessment of pedicle screw position. Spine (Phila Pa 1976) 37(2):E119–E125CrossRef Santos ER, Ledonio CG, Castro CA, Truong WH, Sembrano JN (2012) The accuracy of intraoperative O-arm images for the assessment of pedicle screw position. Spine (Phila Pa 1976) 37(2):E119–E125CrossRef
22.
go back to reference Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr (2011) In vivo accuracy of thoracic pedicle screws. Spine (Phila Pa 1976) 26(21):2340–2346CrossRef Belmont PJ Jr, Klemme WR, Dhawan A, Polly DW Jr (2011) In vivo accuracy of thoracic pedicle screws. Spine (Phila Pa 1976) 26(21):2340–2346CrossRef
23.
go back to reference Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32(3):E111–E120CrossRefPubMed Kosmopoulos V, Schizas C (2007) Pedicle screw placement accuracy: a meta-analysis. Spine 32(3):E111–E120CrossRefPubMed
24.
go back to reference Gelalis ID, Paschos NK, Pakos EE, Politis AN et al (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255CrossRefPubMed Gelalis ID, Paschos NK, Pakos EE, Politis AN et al (2012) Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur Spine J 21:247–255CrossRefPubMed
25.
go back to reference Kaminski L, Cordemans V, Cartiaux O, Van Cauter M (2017) Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study. Eur Spine J. doi:10.1007/s00586-017-4968-z Kaminski L, Cordemans V, Cartiaux O, Van Cauter M (2017) Radiation exposure to the patients in thoracic and lumbar spine fusion using a new intraoperative cone-beam computed tomography imaging technique: a preliminary study. Eur Spine J. doi:10.​1007/​s00586-017-4968-z
26.
go back to reference Cordemans V, Kaminski L, Banse X, Cartiaux O (2017) Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection. Eur Spine J. doi:10.1007/s00586-017-5139-y Cordemans V, Kaminski L, Banse X, Cartiaux O (2017) Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection. Eur Spine J. doi:10.​1007/​s00586-017-5139-y
28.
go back to reference Kleck C, Cullilmore I, La Fleur M, Lindley E, Rentschler M, Burger E, Cain C, Patel V (2016) A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy. Eur Spine J 25(6):1764–1774. doi:10.1007/s00586-015-4235-0 CrossRefPubMed Kleck C, Cullilmore I, La Fleur M, Lindley E, Rentschler M, Burger E, Cain C, Patel V (2016) A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy. Eur Spine J 25(6):1764–1774. doi:10.​1007/​s00586-015-4235-0 CrossRefPubMed
29.
go back to reference van Dijk JD, van den Ende RP, Stramigioli S, Köchling M, Höss N (2015) Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery. Spine 40(17):E986–E991CrossRefPubMed van Dijk JD, van den Ende RP, Stramigioli S, Köchling M, Höss N (2015) Clinical pedicle screw accuracy and deviation from planning in robot-guided spine surgery. Spine 40(17):E986–E991CrossRefPubMed
Metadata
Title
Pedicle screw insertion accuracy in terms of breach and reposition using a new intraoperative cone beam computed tomography imaging technique and evaluation of the factors associated with these parameters of accuracy: a series of 695 screws
Authors
Virginie Cordemans
Ludovic Kaminski
Xavier Banse
Bernard G. Francq
Christine Detrembleur
Olivier Cartiaux
Publication date
01-11-2017
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 11/2017
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-017-5195-3

Other articles of this Issue 11/2017

European Spine Journal 11/2017 Go to the issue