Skip to main content
Top
Published in: European Spine Journal 5/2015

01-05-2015 | Review

Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review

Authors: Ahmed A. Aoude, Maryse Fortin, Rainer Figueiredo, Peter Jarzem, Jean Ouellet, Michael H. Weber

Published in: European Spine Journal | Issue 5/2015

Login to get access

Abstract

Study design

Systematic review.

Objectives

The aims of this systematic review were: (1) to determine the most commonly used methods for assessing pedicle screw placement accuracy, and (2) assess the difference in pedicle screw placement accuracy between navigation and free-hand techniques according to the classification method.

Background data

Pedicle screw fixation and spine surgery have almost become synonymous. However, there is currently no gold standard method to assess pedicle screw placement accuracy. We reviewed the literature to determine current techniques used by spine surgeons for the assessment of pedicle screw accuracy.

Methods

We systematically reviewed the medical literature (OVID Medline, Embase, PubMed) to identify all articles published between 2010 and 2013 that have assessed pedicle screw placement accuracy in humans. Two independent reviewers with a third independent mediator performed study screening, selection and data extraction using a blinded and objective protocol.

Results

A total of 68 relevant articles were included in this systematic review, for a total of 3442 patients, 60 cadavers and 43,305 pedicle screws. The most widely used method (37 articles) was based on 2 mm breach increments measured on computer tomography images. The second most widely used method consisted of an “in” or “out” classification system (16 articles). The remaining 15 articles used variable classification systems. Our result suggests that an average of 91.4 % of pedicle screws placed with free-hand or fluoroscopy technique where within the safe zone (<2 mm breach) in comparison to an average of 97.3 % of pedicle screws using navigation (p < 0.001) for the 2 mm increment method. Similarly, the in or out classification also showed statistically significant difference between free-hand and navigated techniques (p < 0.001).

Conclusion

The grading system based on 2 mm increments seems to be the most widely accepted method for determining pedicle screw placement accuracy. All grading systems were based on imaging alone without taking into account the direction of the breach or patient’s symptoms.
Literature
1.
go back to reference Obernauer J, Kavakebi P, Quirbach S, Thome C (2014) Pedicle-Based Non-fusion Stabilization Devices: a Critical Review and Appraisal of Current Evidence. Adv Tech Stand Neurosurg 41:131–142. doi:10.1007/978-3-319-01830-0_6 PubMed Obernauer J, Kavakebi P, Quirbach S, Thome C (2014) Pedicle-Based Non-fusion Stabilization Devices: a Critical Review and Appraisal of Current Evidence. Adv Tech Stand Neurosurg 41:131–142. doi:10.​1007/​978-3-319-01830-0_​6 PubMed
2.
go back to reference Boos N, Webb JK (1997) Pedicle screw fixation in spinal disorders: a European view. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc 6:2–18CrossRef Boos N, Webb JK (1997) Pedicle screw fixation in spinal disorders: a European view. Eur Spine J Off Publ Eur Spine Soc Eur Spinal Deform Soc Eur Sect Cerv Spine Res Soc 6:2–18CrossRef
3.
go back to reference Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 213:7–17 Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 213:7–17
4.
go back to reference Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159PubMed Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159PubMed
5.
go back to reference Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 189:125–141 Magerl FP (1984) Stabilization of the lower thoracic and lumbar spine with external skeletal fixation. Clin Orthop Relat Res 189:125–141
6.
go back to reference Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32CrossRefPubMed Krag MH, Weaver DL, Beynnon BD, Haugh LD (1988) Morphometry of the thoracic and lumbar spine related to transpedicular screw placement for surgical spinal fixation. Spine 13:27–32CrossRefPubMed
7.
go back to reference Yahiro MA (1994) Review of the “Historical Cohort Study of Pedicle Screw Fixation in Thoracic, Lumbar, and Sacral Spinal Fusions” report. Spine 19:2297s–2299sCrossRefPubMed Yahiro MA (1994) Review of the “Historical Cohort Study of Pedicle Screw Fixation in Thoracic, Lumbar, and Sacral Spinal Fusions” report. Spine 19:2297s–2299sCrossRefPubMed
8.
go back to reference Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231–2238 (discussion 2238–2239)CrossRefPubMed Esses SI, Sachs BL, Dreyzin V (1993) Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members. Spine 18:2231–2238 (discussion 2238–2239)CrossRefPubMed
9.
go back to reference Soultanis KC, Sakellariou VI, Starantzis KA, Papagelopoulos PJ (2013) Late diagnosis of perforation of the aorta by a pedicle screw. Acta Orthop Belg 79:361–367PubMed Soultanis KC, Sakellariou VI, Starantzis KA, Papagelopoulos PJ (2013) Late diagnosis of perforation of the aorta by a pedicle screw. Acta Orthop Belg 79:361–367PubMed
11.
14.
go back to reference Costa F, Cardia A, Ortolina A, Fabio G, Zerbi A, Fornari M (2011) Spinal navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system radiological and clinical study in 100 consecutive patients. Spine 36:2094–2098. doi:10.1097/BRS.0b013e318201129d CrossRefPubMed Costa F, Cardia A, Ortolina A, Fabio G, Zerbi A, Fornari M (2011) Spinal navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system radiological and clinical study in 100 consecutive patients. Spine 36:2094–2098. doi:10.​1097/​BRS.​0b013e318201129d​ CrossRefPubMed
15.
go back to reference Cui G, Wang Y, Kao TH, Zhang Y, Liu Z, Liu B, Li J, Zhang X, Zhu S, Lu N, Mao K, Wang Z, Zhang X, Yuan X, Dong T, Xiao S (2012) Application of intraoperative computed tomography with or without navigation system in surgical correction of spinal deformity a preliminary result of 59 consecutive human cases. Spine 37:891–900. doi:10.1097/BRS.0b013e31823aff81 CrossRefPubMed Cui G, Wang Y, Kao TH, Zhang Y, Liu Z, Liu B, Li J, Zhang X, Zhu S, Lu N, Mao K, Wang Z, Zhang X, Yuan X, Dong T, Xiao S (2012) Application of intraoperative computed tomography with or without navigation system in surgical correction of spinal deformity a preliminary result of 59 consecutive human cases. Spine 37:891–900. doi:10.​1097/​BRS.​0b013e31823aff81​ CrossRefPubMed
16.
go back to reference Devito DP, Kaplan L, Dietl R, Pfeiffer M, Horne D, Silberstein B, Hardenbrook M, Kiriyanthan G, Barzilay Y, Bruskin A, Sackerer D, Alexandrovsky V, Stüer C, Burger R, Maeurer J, Donald GD, Schoenmayr R, Friedlander A, Knoller N, Schmieder K, Pechlivanis I, Kim IS, Meyer B, Shoham M (2010) Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot retrospective study. Spine 35:2109–2115. doi:10.1097/BRS.0b013e3181d323ab CrossRefPubMed Devito DP, Kaplan L, Dietl R, Pfeiffer M, Horne D, Silberstein B, Hardenbrook M, Kiriyanthan G, Barzilay Y, Bruskin A, Sackerer D, Alexandrovsky V, Stüer C, Burger R, Maeurer J, Donald GD, Schoenmayr R, Friedlander A, Knoller N, Schmieder K, Pechlivanis I, Kim IS, Meyer B, Shoham M (2010) Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot retrospective study. Spine 35:2109–2115. doi:10.​1097/​BRS.​0b013e3181d323ab​ CrossRefPubMed
18.
go back to reference Fan Chiang CY, Tsai TT, Chen LH, Lai PL, Fu TS, Niu CC, Chen WJ (2012) Computed tomography-based navigation-assisted pedicle screw insertion for thoracic and lumbar spine fractures. Chang Gung Med J 35:332–338PubMed Fan Chiang CY, Tsai TT, Chen LH, Lai PL, Fu TS, Niu CC, Chen WJ (2012) Computed tomography-based navigation-assisted pedicle screw insertion for thoracic and lumbar spine fractures. Chang Gung Med J 35:332–338PubMed
19.
20.
21.
24.
go back to reference Ringel F, Stüer C, Reinke A, Preuss A, Behr M, Auer F, Stoffel M, Meyer B (2012) Accuracy of robot-assisted placement of lumbar and sacral pedicle screws a prospective randomized comparison to conventional freehand screw implantation. Spine 37:E496–E501. doi:10.1097/BRS.0b013e31824b7767 CrossRefPubMed Ringel F, Stüer C, Reinke A, Preuss A, Behr M, Auer F, Stoffel M, Meyer B (2012) Accuracy of robot-assisted placement of lumbar and sacral pedicle screws a prospective randomized comparison to conventional freehand screw implantation. Spine 37:E496–E501. doi:10.​1097/​BRS.​0b013e31824b7767​ CrossRefPubMed
26.
go back to reference Schizas C, Thein E, Kwiatkowski B, Kulik G (2012) Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy. Acta Orthop Belg 78:240–245PubMed Schizas C, Thein E, Kwiatkowski B, Kulik G (2012) Pedicle screw insertion: robotic assistance versus conventional C-arm fluoroscopy. Acta Orthop Belg 78:240–245PubMed
27.
go back to reference Shin BJ, Njoku IU, Tsiouris AJ, Härtl R (2013) Navigated guide tube for the placement of mini-open pedicle screws using stereotactic 3D navigation without the use of K-wires technical note. J Neurosurg Spine 18:178–183. doi:10.3171/2012.10.spine12569 CrossRefPubMed Shin BJ, Njoku IU, Tsiouris AJ, Härtl R (2013) Navigated guide tube for the placement of mini-open pedicle screws using stereotactic 3D navigation without the use of K-wires technical note. J Neurosurg Spine 18:178–183. doi:10.​3171/​2012.​10.​spine12569 CrossRefPubMed
30.
31.
go back to reference Amato V, Giannachi L, Irace C, Corona C (2010) Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients. J Neurosur Spine 12:306–313. doi:10.3171/2009.9.spine09261 CrossRef Amato V, Giannachi L, Irace C, Corona C (2010) Accuracy of pedicle screw placement in the lumbosacral spine using conventional technique: computed tomography postoperative assessment in 102 consecutive patients. J Neurosur Spine 12:306–313. doi:10.​3171/​2009.​9.​spine09261 CrossRef
32.
go back to reference Bai YS, Niu YF, Chen ZQ, Zhu XD, Gabriel LK, Wong HK, Li M (2013) Comparison of the pedicle screws placement between electronic conductivity device and normal pedicle finder in posterior surgery of scoliosis. J Spinal Disord Tech 26:316–320. doi:10.1097/BSD.0b013e318247f21d CrossRefPubMed Bai YS, Niu YF, Chen ZQ, Zhu XD, Gabriel LK, Wong HK, Li M (2013) Comparison of the pedicle screws placement between electronic conductivity device and normal pedicle finder in posterior surgery of scoliosis. J Spinal Disord Tech 26:316–320. doi:10.​1097/​BSD.​0b013e318247f21d​ CrossRefPubMed
33.
35.
go back to reference Oertel MF, Hobart J, Stein M, Schreiber V, Scharbrodt W (2011) Clinical and methodological precision of spinal navigation assisted by 3D intraoperative O-arm radiographic imaging Technical note. J Neurosurg Spine 14:532–536. doi:10.3171/2010.10.spine091032 CrossRefPubMed Oertel MF, Hobart J, Stein M, Schreiber V, Scharbrodt W (2011) Clinical and methodological precision of spinal navigation assisted by 3D intraoperative O-arm radiographic imaging Technical note. J Neurosurg Spine 14:532–536. doi:10.​3171/​2010.​10.​spine091032 CrossRefPubMed
39.
go back to reference Parker SL, McGirt MJ, Farber SH, Amin AG, Rick AM, Suk I, Bydon A, Sciubba DM, Wolinsky JP, Gokaslan ZL, Witham TF (2011) Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68:170–178. doi:10.1227/NEU.0b013e3181fdfaf4 CrossRefPubMed Parker SL, McGirt MJ, Farber SH, Amin AG, Rick AM, Suk I, Bydon A, Sciubba DM, Wolinsky JP, Gokaslan ZL, Witham TF (2011) Accuracy of free-hand pedicle screws in the thoracic and lumbar spine: analysis of 6816 consecutive screws. Neurosurgery 68:170–178. doi:10.​1227/​NEU.​0b013e3181fdfaf4​ CrossRefPubMed
40.
go back to reference Liang H, Zhang C, Yan M, Zhou J (2005) Data Correction for Gantry-tilted Local CT. Conf Proc Annu Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Annu Conf 2:1798–1801. doi:10.1109/iembs.2005.1616797 Liang H, Zhang C, Yan M, Zhou J (2005) Data Correction for Gantry-tilted Local CT. Conf Proc Annu Int Conf IEEE Eng Med Biol Soc IEEE Eng Med Biol Soc Annu Conf 2:1798–1801. doi:10.​1109/​iembs.​2005.​1616797
41.
go back to reference Alhabib H, Nataraj A, Khashab M, Mahood J, Kortbeek F, Fox R (2011) Pedicle screw insertion in the thoracolumbar spine: comparison of 4 guidance techniques in the intact cadaveric spine. J Neurosurg Spine 14:664–669. doi:10.3171/2010.11.spine10177 PubMed Alhabib H, Nataraj A, Khashab M, Mahood J, Kortbeek F, Fox R (2011) Pedicle screw insertion in the thoracolumbar spine: comparison of 4 guidance techniques in the intact cadaveric spine. J Neurosurg Spine 14:664–669. doi:10.​3171/​2010.​11.​spine10177 PubMed
42.
go back to reference Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778 (discussion 778–779)PubMed Youkilis AS, Quint DJ, McGillicuddy JE, Papadopoulos SM (2001) Stereotactic navigation for placement of pedicle screws in the thoracic spine. Neurosurgery 48:771–778 (discussion 778–779)PubMed
43.
go back to reference Han W, Gao ZL, Wang JC, Li YP, Peng X, Rui J, Jun W (2010) Pedicle screw placement in the thoracic spine: a comparison study of computer-assisted navigation and conventional techniques. Orthopedics 33(8):201–205. doi:10.3928/01477447-20100625-14 Han W, Gao ZL, Wang JC, Li YP, Peng X, Rui J, Jun W (2010) Pedicle screw placement in the thoracic spine: a comparison study of computer-assisted navigation and conventional techniques. Orthopedics 33(8):201–205. doi:10.​3928/​01477447-20100625-14
45.
go back to reference Iampreechakul P, Chongchokdee C, Tirakotai W (2011) The accuracy of computer-assisted pedicle screw placement in degenerative lumbrosacral spine using single-time, paired point registration alone technique combined with the surgeon’s experience. J Med Assoc Thai (Chotmaihet thangphaet) 94:337–345 Iampreechakul P, Chongchokdee C, Tirakotai W (2011) The accuracy of computer-assisted pedicle screw placement in degenerative lumbrosacral spine using single-time, paired point registration alone technique combined with the surgeon’s experience. J Med Assoc Thai (Chotmaihet thangphaet) 94:337–345
47.
go back to reference Lieberman IHH, Mitchell A, Wang Jeffrey C, Guyer Richard D (2012) Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system. J Spinal Disord Tech 25:241–248. doi:10.1097/BSD.0b013e318218a5ef CrossRefPubMed Lieberman IHH, Mitchell A, Wang Jeffrey C, Guyer Richard D (2012) Assessment of pedicle screw placement accuracy, procedure time, and radiation exposure using a miniature robotic guidance system. J Spinal Disord Tech 25:241–248. doi:10.​1097/​BSD.​0b013e318218a5ef​ CrossRefPubMed
48.
go back to reference Lotfinia I, Sayahmelli S, Gavami M (2010) Postoperative computed tomography assessment of pedicle screw placement accuracy. Turk Neurosurg 20:500–507PubMed Lotfinia I, Sayahmelli S, Gavami M (2010) Postoperative computed tomography assessment of pedicle screw placement accuracy. Turk Neurosurg 20:500–507PubMed
49.
go back to reference Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg 133:893–899. doi:10.1007/s00402-013-1755-0 CrossRefPubMed Merc M, Drstvensek I, Vogrin M, Brajlih T, Recnik G (2013) A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine. Arch Orthop Trauma Surg 133:893–899. doi:10.​1007/​s00402-013-1755-0 CrossRefPubMed
50.
go back to reference Raley DA, Mobbs RJ (2012) Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine accuracy and complication rates. Spine 37:1092–1100. doi:10.1097/BRS.0b013e31823c80d8 CrossRefPubMed Raley DA, Mobbs RJ (2012) Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine accuracy and complication rates. Spine 37:1092–1100. doi:10.​1097/​BRS.​0b013e31823c80d8​ CrossRefPubMed
51.
go back to reference Rampersaud YR, Pik JH, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30:E183–E190 (00007632-200504010-00026 [pii])CrossRefPubMed Rampersaud YR, Pik JH, Salonen D, Farooq S (2005) Clinical accuracy of fluoroscopic computer-assisted pedicle screw fixation: a CT analysis. Spine 30:E183–E190 (00007632-200504010-00026 [pii])CrossRefPubMed
53.
go back to reference Sugimoto Y, Ito Y, Tomioka M, Shimokawa T, Shiozaki Y, Mazaki T, Tanaka M (2010) Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion. Acta Medica Okayama 64:209–212PubMed Sugimoto Y, Ito Y, Tomioka M, Shimokawa T, Shiozaki Y, Mazaki T, Tanaka M (2010) Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion. Acta Medica Okayama 64:209–212PubMed
55.
go back to reference Watanabe K, Matsumoto M, Tsuji T, Ishii K, Takaishi H, Nakamura M, Toyama Y, Chiba K (2010) Ball tip technique for thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis Technical note. J Neurosurg Spine 13:246–252. doi:10.3171/2010.3.spine09497 CrossRefPubMed Watanabe K, Matsumoto M, Tsuji T, Ishii K, Takaishi H, Nakamura M, Toyama Y, Chiba K (2010) Ball tip technique for thoracic pedicle screw placement in patients with adolescent idiopathic scoliosis Technical note. J Neurosurg Spine 13:246–252. doi:10.​3171/​2010.​3.​spine09497 CrossRefPubMed
57.
go back to reference Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine 29:767–773 (00007632-200404010-00011 [pii])CrossRefPubMed Learch TJ, Massie JB, Pathria MN, Ahlgren BA, Garfin SR (2004) Assessment of pedicle screw placement utilizing conventional radiography and computed tomography: a proposed systematic approach to improve accuracy of interpretation. Spine 29:767–773 (00007632-200404010-00011 [pii])CrossRefPubMed
58.
go back to reference Wu H, Gao ZL, Wang JC, Li YP, Xia P, Jiang R (2010) Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques. Chin J Traumatol (Zhonghua chuang shang za zhi/Chinese Medical Association) 13:201–205 Wu H, Gao ZL, Wang JC, Li YP, Xia P, Jiang R (2010) Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques. Chin J Traumatol (Zhonghua chuang shang za zhi/Chinese Medical Association) 13:201–205
59.
60.
69.
go back to reference Tohtz SW, Rogalla P, Taupitz M, Perka C, Winkler T, Putzier M (2010) Inter- and intraobserver variability in the postoperative evaluation of transpedicular stabilization: computed tomography versus magnetic resonance imaging. Spine J 10:285–290. doi:10.1016/j.spinee.2009.12.020 CrossRefPubMed Tohtz SW, Rogalla P, Taupitz M, Perka C, Winkler T, Putzier M (2010) Inter- and intraobserver variability in the postoperative evaluation of transpedicular stabilization: computed tomography versus magnetic resonance imaging. Spine J 10:285–290. doi:10.​1016/​j.​spinee.​2009.​12.​020 CrossRefPubMed
70.
go back to reference Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation navigation. Spine 37:E1580–E1587. doi:10.1097/BRS.0b013e318271b1fa CrossRefPubMed Van de Kelft E, Costa F, Van der Planken D, Schils F (2012) A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation navigation. Spine 37:E1580–E1587. doi:10.​1097/​BRS.​0b013e318271b1fa​ CrossRefPubMed
74.
go back to reference Ammirati M, Salma A (2013) Placement of thoracolumbar pedicle screws using O-arm-based navigation: technical note on controlling the operational accuracy of the navigation system. Neurosurg Rev 36:157–162. doi:10.1007/s10143-012-0421-2 CrossRefPubMed Ammirati M, Salma A (2013) Placement of thoracolumbar pedicle screws using O-arm-based navigation: technical note on controlling the operational accuracy of the navigation system. Neurosurg Rev 36:157–162. doi:10.​1007/​s10143-012-0421-2 CrossRefPubMed
76.
77.
80.
go back to reference Xu R, Ebraheim NA, Shepherd ME, Yeasting RA (1999) Thoracic pedicle screw placement guided by computed tomographic measurements. J Spinal Disord 12:222–226PubMed Xu R, Ebraheim NA, Shepherd ME, Yeasting RA (1999) Thoracic pedicle screw placement guided by computed tomographic measurements. J Spinal Disord 12:222–226PubMed
81.
82.
go back to reference Ughwanogho E, Patel NM, Baldwin KD, Sampson NR, Flynn JM (2012) Computed tomography-guided navigation of thoracic pedicle screws for adolescent idiopathic scoliosis results in more accurate placement and less screw removal. Spine 37:E473–E478. doi:10.1097/BRS.0b013e318238bbd9 CrossRefPubMed Ughwanogho E, Patel NM, Baldwin KD, Sampson NR, Flynn JM (2012) Computed tomography-guided navigation of thoracic pedicle screws for adolescent idiopathic scoliosis results in more accurate placement and less screw removal. Spine 37:E473–E478. doi:10.​1097/​BRS.​0b013e318238bbd9​ CrossRefPubMed
83.
go back to reference von Jako R, Finn MA, Yonemura KS, Araghi A, Khoo LT, Carrino JA, Perez-Cruet M (2011) Minimally invasive percutaneous transpedicular screw fixation: increased accuracy and reduced radiation exposure by means of a novel electromagnetic navigation system. Acta Neurochir 153:589–596. doi:10.1007/s00701-010-0882-4 CrossRef von Jako R, Finn MA, Yonemura KS, Araghi A, Khoo LT, Carrino JA, Perez-Cruet M (2011) Minimally invasive percutaneous transpedicular screw fixation: increased accuracy and reduced radiation exposure by means of a novel electromagnetic navigation system. Acta Neurochir 153:589–596. doi:10.​1007/​s00701-010-0882-4 CrossRef
84.
go back to reference Yson SC, Sembrano JN, Sanders PC, Santos ER, Ledonio CG, Polly DW Jr (2013) Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation. Spine 38:E251–E258. doi:10.1097/BRS.0b013e31827ecbf1 CrossRefPubMed Yson SC, Sembrano JN, Sanders PC, Santos ER, Ledonio CG, Polly DW Jr (2013) Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation. Spine 38:E251–E258. doi:10.​1097/​BRS.​0b013e31827ecbf1​ CrossRefPubMed
Metadata
Title
Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review
Authors
Ahmed A. Aoude
Maryse Fortin
Rainer Figueiredo
Peter Jarzem
Jean Ouellet
Michael H. Weber
Publication date
01-05-2015
Publisher
Springer Berlin Heidelberg
Published in
European Spine Journal / Issue 5/2015
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-015-3853-x

Other articles of this Issue 5/2015

European Spine Journal 5/2015 Go to the issue