Is a collagen scaffold for a tissue engineered nucleus replacement capable of restoring disc height and stability in an animal model?

Authors: Hans-Joachim Wilke, Frank Heuer, Cornelia Neidlinger-Wilke, Lutz Claes

Published in: European Spine Journal | Special Issue 3/2006

Login to get access

Abstract

The idea of a tissue engineered nucleus implant is to seed cells in a three-dimensional collagen matrix. This matrix may serve as a scaffold for a tissue engineered nucleus implant. The aim of this study was to investigate whether implantation of the collagen matrix into a spinal segment after nucleotomy is able to restore disc height and flexibility. The implant basically consists of condensed collagen type-I matrix. For clinical use, this matrix will be used for reinforcing and supporting the culturing of nucleus cells. In experiments, matrixes were concentrated with barium sulfate for X-ray purposes and cell seeding was disclaimed in order to evaluate the biomechanical performance of the collagen material. Six bovine lumbar functional spinal units, aging between 5 and 6 months, were used for the biomechanical in-vitro test. In each specimen, an oblique incision was performed, the nucleus was removed and replaced by a collagen-type-I matrix. Specimens were mounted in a custom-built spine tester, and subsequently exposed to pure moments of 7.5 Nm to move within the three anatomical planes. Each tested stage (intact, nucleotomy and implanted) was evaluated for range of motion, neutral zone and change in disc height. Removal of the nucleus significantly reduced disc height by 0.84 mm in respect to the intact stage and caused an instability in the segment. Through the implantation of the tissue engineered nucleus it was possible to restore this height and stability loss, and even to increase slightly the disc height of 0.07 mm compared with the intact stage. There was no statistical difference between the stability provided by the implant and intact stage. Results of movements in lateral bending and axial rotation showed the same trend compared to flexion/extension. However, implant extrusions have been observed in three of six cases during the flexibility assessment. The results of this study directly reflect the efficacy of vital nucleus replacement to restore disc height and to provide stability to intervertebral discs. However, from a biomechanical point of view, the challenge is to employ an appropriate annulus fibrosus sealing method, which is capable to keep the nucleus implant in place over a long-time period. Securing the nucleus implant inside the disc is one of the most important biomechanical prerequisites if such a tissue engineered implant shall have a chance for clinical application.
Literature
1.
go back to reference Alini M, Li W, Markovic P, Aebi M, Spiro RC, and Roughley PJ (2003) The potential and limitations of a cell-seeded collagen/hyaluronan scaffold to engineer an intervertebral disc-like matrix. Spine 28(5):446–454; discussion 453 Alini M, Li W, Markovic P, Aebi M, Spiro RC, and Roughley PJ (2003) The potential and limitations of a cell-seeded collagen/hyaluronan scaffold to engineer an intervertebral disc-like matrix. Spine 28(5):446–454; discussion 453
2.
go back to reference Allen MJ, Schoonmaker JE, Bauer TW, Williams PF, Higham PA, Yuan HA (2004) Preclinical evaluation of a poly (vinyl alcohol) hydrogel implant as a replacement for the nucleus pulposus. Spine 29(5):515–523PubMedCrossRef Allen MJ, Schoonmaker JE, Bauer TW, Williams PF, Higham PA, Yuan HA (2004) Preclinical evaluation of a poly (vinyl alcohol) hydrogel implant as a replacement for the nucleus pulposus. Spine 29(5):515–523PubMedCrossRef
3.
4.
go back to reference Brinckmann P, Grootenboer H (1991) Change of disc height, radial disc bulge, and intradiscal pressure from discectomy. An in vitro investigation on human lumbar discs. Spine 16(6):641–646PubMedCrossRef Brinckmann P, Grootenboer H (1991) Change of disc height, radial disc bulge, and intradiscal pressure from discectomy. An in vitro investigation on human lumbar discs. Spine 16(6):641–646PubMedCrossRef
5.
go back to reference Carl A, Ledet E, Yuan H, Sharan A (2004) New developments in nucleus pulposus replacement technology. Spine J 4(6 Suppl):325S–329SPubMedCrossRef Carl A, Ledet E, Yuan H, Sharan A (2004) New developments in nucleus pulposus replacement technology. Spine J 4(6 Suppl):325S–329SPubMedCrossRef
6.
go back to reference Di Martino A, Vaccaro AR, Lee JY, Denaro V, Lim MR (2005) Nucleus pulposus replacement: basic science and indications for clinical use. Spine 30(16 Suppl):S16–S22PubMedCrossRef Di Martino A, Vaccaro AR, Lee JY, Denaro V, Lim MR (2005) Nucleus pulposus replacement: basic science and indications for clinical use. Spine 30(16 Suppl):S16–S22PubMedCrossRef
7.
go back to reference Frei H, Oxland TR, Rathonyi GC, Nolte LP (2001) The effect of nucleotomy on lumbar spine mechanics in compression and shear loading. Spine 26(19):2080–2089PubMedCrossRef Frei H, Oxland TR, Rathonyi GC, Nolte LP (2001) The effect of nucleotomy on lumbar spine mechanics in compression and shear loading. Spine 26(19):2080–2089PubMedCrossRef
8.
go back to reference Ganey TM, Meisel HJ (2002) A potential role for cell-based therapeutics in the treatment of intervertebral disc herniation. Eur Spine J 11(Suppl 2):S206–S214PubMed Ganey TM, Meisel HJ (2002) A potential role for cell-based therapeutics in the treatment of intervertebral disc herniation. Eur Spine J 11(Suppl 2):S206–S214PubMed
9.
go back to reference Goel VK, Goyal S, Clark C, Nishiyama K, Nye T (1985) Kinematics of the whole lumbar spine. Effect of disectomy. Spine 10(6):543–554PubMedCrossRef Goel VK, Goyal S, Clark C, Nishiyama K, Nye T (1985) Kinematics of the whole lumbar spine. Effect of disectomy. Spine 10(6):543–554PubMedCrossRef
10.
go back to reference Husson JL, Korge A, Polard JL, Nydegger T, Kneubuhler S, Mayer HM (2003) A memory coiling spiral as nucleus pulposus prosthesis: concept, specifications, bench testing, and first clinical results. J Spinal Disord Tech 16(4):405–411PubMed Husson JL, Korge A, Polard JL, Nydegger T, Kneubuhler S, Mayer HM (2003) A memory coiling spiral as nucleus pulposus prosthesis: concept, specifications, bench testing, and first clinical results. J Spinal Disord Tech 16(4):405–411PubMed
11.
go back to reference Jonsson B, Stromqvist B (1995) Influence of age on symptoms and signs in lumbar disc herniation. Eur Spine J 4(4):202–205PubMedCrossRef Jonsson B, Stromqvist B (1995) Influence of age on symptoms and signs in lumbar disc herniation. Eur Spine J 4(4):202–205PubMedCrossRef
12.
go back to reference Klara PM, Ray CD (2002) Artificial nucleus replacement: clinical experience. Spine 27(12):1374–1377PubMedCrossRef Klara PM, Ray CD (2002) Artificial nucleus replacement: clinical experience. Spine 27(12):1374–1377PubMedCrossRef
13.
go back to reference Korge A, Nydegger T, Polard JL, Mayer HM, Husson JL (2002) A spiral implant as nucleus prosthesis in the lumbar spine. Eur Spine J 11(Suppl 2):S149–S153PubMed Korge A, Nydegger T, Polard JL, Mayer HM, Husson JL (2002) A spiral implant as nucleus prosthesis in the lumbar spine. Eur Spine J 11(Suppl 2):S149–S153PubMed
14.
go back to reference Meakin JR, Reid JE, Hukins DW (2001) Replacing the nucleus pulposus of the intervertebral disc. Clin Biomech (Bristol, Avon) 16(7):560–565CrossRef Meakin JR, Reid JE, Hukins DW (2001) Replacing the nucleus pulposus of the intervertebral disc. Clin Biomech (Bristol, Avon) 16(7):560–565CrossRef
15.
go back to reference Natarajan RN, Andersson GB, Patwardhan AG, Verma S (2002) Effect of annular incision type on the change in biomechanical properties in a herniated lumbar intervertebral disc. J Biomech Eng 124(2):229–236PubMedCrossRef Natarajan RN, Andersson GB, Patwardhan AG, Verma S (2002) Effect of annular incision type on the change in biomechanical properties in a herniated lumbar intervertebral disc. J Biomech Eng 124(2):229–236PubMedCrossRef
16.
go back to reference Neidlinger-Wilke C, Wurtz K, Liedert A, et al (2005) A three-dimensional collagen matrix as a suitable culture system for the comparison of cyclic strain and hydrostatic pressure effects on intervertebral disc cells. J Neurosurg Spine 2(4):457–465PubMedCrossRef Neidlinger-Wilke C, Wurtz K, Liedert A, et al (2005) A three-dimensional collagen matrix as a suitable culture system for the comparison of cyclic strain and hydrostatic pressure effects on intervertebral disc cells. J Neurosurg Spine 2(4):457–465PubMedCrossRef
17.
go back to reference Nishimura K, Mochida J (1998) Percutaneous reinsertion of the nucleus pulposus. An experimental study. Spine 23(14):1531–1538; discussion 1539 Nishimura K, Mochida J (1998) Percutaneous reinsertion of the nucleus pulposus. An experimental study. Spine 23(14):1531–1538; discussion 1539
18.
go back to reference Okuma M, Mochida J, Nishimura K, Sakabe K, Seiki K (2000) Reinsertion of stimulated nucleus pulposus cells retards intervertebral disc degeneration: an in vitro and in vivo experimental study. J Orthop Res 18(6):988–997PubMedCrossRef Okuma M, Mochida J, Nishimura K, Sakabe K, Seiki K (2000) Reinsertion of stimulated nucleus pulposus cells retards intervertebral disc degeneration: an in vitro and in vivo experimental study. J Orthop Res 18(6):988–997PubMedCrossRef
19.
go back to reference Ray CD (2002) The PDN prosthetic disc-nucleus device. Eur Spine J 11(Suppl 2):S137–S142PubMed Ray CD (2002) The PDN prosthetic disc-nucleus device. Eur Spine J 11(Suppl 2):S137–S142PubMed
20.
go back to reference Sato M, Asazuma T, Ishihara M, et al (2003) An experimental study of the regeneration of the intervertebral disc with an allograft of cultured annulus fibrosus cells using a tissue-engineering method. Spine 28(6):548–553PubMedCrossRef Sato M, Asazuma T, Ishihara M, et al (2003) An experimental study of the regeneration of the intervertebral disc with an allograft of cultured annulus fibrosus cells using a tissue-engineering method. Spine 28(6):548–553PubMedCrossRef
21.
go back to reference Schoenmayr R, Buch C, Lotz C (1999) Prosthetic disc nucleus implants: the Wiesbaden feasibility study. 2 years follow up in ten patients. Riv Neuroradiol 12(suppl 1):163–170 Schoenmayr R, Buch C, Lotz C (1999) Prosthetic disc nucleus implants: the Wiesbaden feasibility study. 2 years follow up in ten patients. Riv Neuroradiol 12(suppl 1):163–170
22.
go back to reference Steck E, Bertram H, Abel R, Chen B, Winter A, Richter W (2005) Induction of intervertebral disc-like cells from adult mesenchymal stem cells. Stem Cells 23(3):403–411PubMedCrossRef Steck E, Bertram H, Abel R, Chen B, Winter A, Richter W (2005) Induction of intervertebral disc-like cells from adult mesenchymal stem cells. Stem Cells 23(3):403–411PubMedCrossRef
23.
go back to reference Wilke HJ, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3(2):91–97PubMedCrossRef Wilke HJ, Claes L, Schmitt H, Wolf S (1994) A universal spine tester for in vitro experiments with muscle force simulation. Eur Spine J 3(2):91–97PubMedCrossRef
24.
go back to reference Wilke HJ, Kavanagh S, Neller S, Haid C, Claes LE (2001) Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy. J Neurosurg 95(2 Suppl):208–214PubMed Wilke HJ, Kavanagh S, Neller S, Haid C, Claes LE (2001) Effect of a prosthetic disc nucleus on the mobility and disc height of the L4–5 intervertebral disc postnucleotomy. J Neurosurg 95(2 Suppl):208–214PubMed
25.
go back to reference Wilke HJ, Krischak ST, Wenger KH, Claes LE (1997) Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data. Eur Spine J 6(2):129–137PubMedCrossRef Wilke HJ, Krischak ST, Wenger KH, Claes LE (1997) Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data. Eur Spine J 6(2):129–137PubMedCrossRef
Metadata
Title
Is a collagen scaffold for a tissue engineered nucleus replacement capable of restoring disc height and stability in an animal model?
Authors
Hans-Joachim Wilke
Frank Heuer
Cornelia Neidlinger-Wilke
Lutz Claes
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
European Spine Journal / Issue Special Issue 3/2006
Print ISSN: 0940-6719
Electronic ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-006-0177-x

Other articles of this Special Issue 3/2006

European Spine Journal 3/2006 Go to the issue