Abstract

Background

Preeclampsia is characterized by increased extracellular fluid which manifests as generalized edema due to endothelial injury and subsequent capillary leak. Therefore, preeclampsia may lead to increased skin to subarachnoid distance (SSD) which may influence daily clinical practice in this particular gravid population.

Methods

Age- and height-matched gravidas with and without preeclampsia were enrolled prospectively at an allocation ratio of 1:4. Spinal anesthesia (SA) was performed in a sitting position by a mid-line approach at the L3–L4 interspace using a 25-gauge Quincke spinal needle. An internal pilot study was performed to determine the sample size. When the protocol violations were excluded, 146 gravidas were included in the study (25 preeclamptics and 121 normotensive controls) for final analysis.

Results

On average, SSD was 0.89 cm greater in preeclamptics compared to normotensive controls. Mean values of the SSD in preeclamptic and normotensive control group patients at the L3–L4 interspace were 6.187 ± 0.967 and 5.301 ± 0.834 cm, respectively. SSD was significantly correlated with body weight and body mass index (BMI). The regression formula for the estimation of SSD in preeclamptic gravidas with BMI during SA was SSD = 3.696 + 0.075×BMI. The regression formula for the estimation of SSD in the normotensive control group with BMI during SA was SSD = 3.144 + 0.067×BMI − 0.0001×BMI×BMI.

Conclusion

Knowing that the SSD is increased in preeclamptics compared to normotensive gravidas may be of value in terms of selecting needle, and providing safe and comfortable anesthesia.
Literature
1.
go back to reference Cunningham FG, Leveno KJ, Bloom SL, Spong CY, Dashe JS, Hoffman BL, Casey BM, Sheffield JS, editors. Hypertensive disorders. In: Williams obstetrics. McGraw-Hill Education; 2014. p. 2511–694. Cunningham FG, Leveno KJ, Bloom SL, Spong CY, Dashe JS, Hoffman BL, Casey BM, Sheffield JS, editors. Hypertensive disorders. In: Williams obstetrics. McGraw-Hill Education; 2014. p. 2511–694.
2.
go back to reference Bassiakou E, Valsamidis D, Loukeri A, Karathanos A. The distance from the skin to the epidural and subarachnoid spaces in parturients scheduled for caesarean section. Minerva Anestesiol. 2011; 77(2):154–159. pii: R02105827. Bassiakou E, Valsamidis D, Loukeri A, Karathanos A. The distance from the skin to the epidural and subarachnoid spaces in parturients scheduled for caesarean section. Minerva Anestesiol. 2011; 77(2):154–159. pii: R02105827.
3.
go back to reference Shiroyama K, Izumi H, Kubo T, Nakamura R. Distance from the skin to the epidural space at the first lumbar interspace in a Japanese obstetric population. Hiroshima J Med Sci. 2003;52(2):27–9.PubMed Shiroyama K, Izumi H, Kubo T, Nakamura R. Distance from the skin to the epidural space at the first lumbar interspace in a Japanese obstetric population. Hiroshima J Med Sci. 2003;52(2):27–9.PubMed
9.
10.
go back to reference Chen KP, Poon YY, Wong CH. The depth to the epidural space. Ma Zui Xue Za Zhi. 1989;27(4):353–6.PubMed Chen KP, Poon YY, Wong CH. The depth to the epidural space. Ma Zui Xue Za Zhi. 1989;27(4):353–6.PubMed
11.
go back to reference Hoffmann VL, Vercauteren MP, Buczkowski PW, Vanspringel GL. A new combined spinal-epidural apparatus: measurement of the distance to the epidural and subarachnoid spaces. Anaesthesia. 1997;52(4):350–5.PubMedCrossRef Hoffmann VL, Vercauteren MP, Buczkowski PW, Vanspringel GL. A new combined spinal-epidural apparatus: measurement of the distance to the epidural and subarachnoid spaces. Anaesthesia. 1997;52(4):350–5.PubMedCrossRef
12.
go back to reference Meiklejohn BH. Distance from skin to the lumbar epidural space in an obstetric population. Reg Anesth. 1990;15(3):134–6.PubMed Meiklejohn BH. Distance from skin to the lumbar epidural space in an obstetric population. Reg Anesth. 1990;15(3):134–6.PubMed
13.
go back to reference Preusser A, Nolte H. An attempt at a mathematical prediction of the depth of insertion of the needle in peridural anesthesia. Anaesthesiol Reanim. 1991;16(2):108–16.PubMed Preusser A, Nolte H. An attempt at a mathematical prediction of the depth of insertion of the needle in peridural anesthesia. Anaesthesiol Reanim. 1991;16(2):108–16.PubMed
17.
go back to reference Aya AG, Vialles N, Tanoubi I, Mangin R, Ferrer JM, Robert C, Ripart J, de La Coussaye JE. Spinal anesthesia-induced hypotension: a risk comparison between patients with severe preeclampsia and healthy women undergoing preterm cesarean delivery. Anesth Analg. 2005;101(3):869–75. doi:10.1213/01.ANE.0000175229.98493.2B.PubMedCrossRef Aya AG, Vialles N, Tanoubi I, Mangin R, Ferrer JM, Robert C, Ripart J, de La Coussaye JE. Spinal anesthesia-induced hypotension: a risk comparison between patients with severe preeclampsia and healthy women undergoing preterm cesarean delivery. Anesth Analg. 2005;101(3):869–75. doi:10.​1213/​01.​ANE.​0000175229.​98493.​2B.PubMedCrossRef
19.
go back to reference Zieleskiewicz L, Contargyris C, Brun C, Touret M, Vellin A, Antonini F, Muller L, Bretelle F, Martin C, Leone M. Lung ultrasound predicts interstitial syndrome and hemodynamic profile in parturients with severe preeclampsia. Anesthesiology. 2014;120(4):906–14. doi:10.1097/ALN.0000000000000102.PubMedCrossRef Zieleskiewicz L, Contargyris C, Brun C, Touret M, Vellin A, Antonini F, Muller L, Bretelle F, Martin C, Leone M. Lung ultrasound predicts interstitial syndrome and hemodynamic profile in parturients with severe preeclampsia. Anesthesiology. 2014;120(4):906–14. doi:10.​1097/​ALN.​0000000000000102​.PubMedCrossRef
21.
go back to reference Hawkins JL, Koonin LM, Palmer SK, Gibbs CP. Anesthesia-related deaths during obstetric delivery in the United States, 1979–1990. Anesthesiology. 1997;86(2):277–84.PubMedCrossRef Hawkins JL, Koonin LM, Palmer SK, Gibbs CP. Anesthesia-related deaths during obstetric delivery in the United States, 1979–1990. Anesthesiology. 1997;86(2):277–84.PubMedCrossRef
23.
go back to reference Ahn WS, Bahk JH, Lim YJ, Kim YC. The effect of introducer gauge, design and bevel direction on the deflection of spinal needles. Anaesthesia. 2002; 57(10):1007–1011. pii: 2657. Ahn WS, Bahk JH, Lim YJ, Kim YC. The effect of introducer gauge, design and bevel direction on the deflection of spinal needles. Anaesthesia. 2002; 57(10):1007–1011. pii: 2657.
24.
go back to reference Joshi GP, McCarroll SM. Evaluation of combined spinal-epidural anesthesia using two different techniques. Reg Anesth. 1994;19(3):169–74.PubMed Joshi GP, McCarroll SM. Evaluation of combined spinal-epidural anesthesia using two different techniques. Reg Anesth. 1994;19(3):169–74.PubMed
25.
go back to reference Lyons G, Macdonald R, Mikl B. Combined epidural/spinal anaesthesia for caesarean section. Through the needle or in separate spaces? Anaesthesia. 1992;47(3):199–201.PubMedCrossRef Lyons G, Macdonald R, Mikl B. Combined epidural/spinal anaesthesia for caesarean section. Through the needle or in separate spaces? Anaesthesia. 1992;47(3):199–201.PubMedCrossRef
27.
go back to reference Shenkman Z, Rathaus V, Jedeikin R, Konen O, Hoppenstein D, Snyder M, Freud E. The distance from the skin to the subarachnoid space can be predicted in premature and former-premature infants. Can J Anaesth. 2004;51(2):160–2. doi:10.1007/BF03018776.PubMedCrossRef Shenkman Z, Rathaus V, Jedeikin R, Konen O, Hoppenstein D, Snyder M, Freud E. The distance from the skin to the subarachnoid space can be predicted in premature and former-premature infants. Can J Anaesth. 2004;51(2):160–2. doi:10.​1007/​BF03018776.PubMedCrossRef
28.
go back to reference Grau T, Leipold RW, Horter J, Conradi R, Martin E, Motsch J. The lumbar epidural space in pregnancy: visualization by ultrasonography. Br J Anaesth. 2001;86(6):798–804.PubMedCrossRef Grau T, Leipold RW, Horter J, Conradi R, Martin E, Motsch J. The lumbar epidural space in pregnancy: visualization by ultrasonography. Br J Anaesth. 2001;86(6):798–804.PubMedCrossRef
Metadata
Title
The effect of preeclampsia on the skin to subarachnoid distance in spinal anesthesia
Authors
B. Basaran
A. Basaran
B. Kozanhan
S. Ozmen
M. Basaran
Publication date
01-06-2015
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 3/2015
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-014-1941-4

Other articles of this Issue 3/2015

Journal of Anesthesia 3/2015 Go to the issue