Skip to main content
Top
Published in: Journal of Anesthesia 3/2015

01-06-2015 | Short Communication

Cannulation needle-induced anterior wall tenting of internal jugular vein causing posterior wall penetration

Authors: Hitoshi Yoshida, Shinya Yaguchi, Hiroyuki Itaya, Kazuo Ito, Ryo Hatanaka, Kishiko Nakai, Kazuyoshi Hirota

Published in: Journal of Anesthesia | Issue 3/2015

Login to get access

Abstract

Unintentional posterior venous wall penetration during internal jugular vein (IJV) cannulation may cause critical arterial injuries in spite of ultrasound guidance. We aimed to evaluate whether small venous diameter and anterior venous wall tenting by a needle would be associated with posterior venous wall penetration, and to seek factors related to the venous wall tenting. We conducted a retrospective review in patients who underwent IJV cannulation. Using an ultrasound view obtained when puncturing, venous diameter, venous wall thickness, anterior venous wall tenting length, and needle angle were measured, and posterior venous wall penetration was determined. Eleven cannulations in 56 patients were assigned to posterior venous wall penetration. Small venous diameter (p = 0.004), and long anterior venous wall tenting (p = 0.007) were associated with posterior venous wall penetration. The longer anterior venous tenting would be expected with reducing needle angle (p = 0.004) or increasing anterior venous wall thickness (p = 0.006). In conclusion, small IJV and anterior venous wall tenting lead to posterior venous wall penetration. Anterior venous wall tenting is longer with reducing needle angle, or increasing the anterior venous wall thickness.
Literature
1.
go back to reference Troianos CA, Hartman GS, Glas KE, Skubas NJ, Eberhardt RT, Walker JD, Reeves ST. Special articles: guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. Anesth Analg. 2012;114:46–72.PubMedCrossRef Troianos CA, Hartman GS, Glas KE, Skubas NJ, Eberhardt RT, Walker JD, Reeves ST. Special articles: guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. Anesth Analg. 2012;114:46–72.PubMedCrossRef
2.
go back to reference Thompson C, Barrows T. Carotid arterial cannulation: removing the risk with ultrasound? Can J Anesth. 2009;56:471–2.PubMedCrossRef Thompson C, Barrows T. Carotid arterial cannulation: removing the risk with ultrasound? Can J Anesth. 2009;56:471–2.PubMedCrossRef
3.
go back to reference Blaivas M. Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access. J Ultrasound Med. 2009;28:1239–44.PubMed Blaivas M. Video analysis of accidental arterial cannulation with dynamic ultrasound guidance for central venous access. J Ultrasound Med. 2009;28:1239–44.PubMed
4.
go back to reference Umegaki N, Hirota K, Kitayama M, Yatsu Y, Ishihara H, Mtasuki A. A marked decrease in bispectral index with elevation of suppression ratio by cervical haematoma reducing cerebral perfusion pressure. J Clin Neurosci. 2003;10:694–6.PubMedCrossRef Umegaki N, Hirota K, Kitayama M, Yatsu Y, Ishihara H, Mtasuki A. A marked decrease in bispectral index with elevation of suppression ratio by cervical haematoma reducing cerebral perfusion pressure. J Clin Neurosci. 2003;10:694–6.PubMedCrossRef
5.
go back to reference Morita M, Sasano H, Azami T, Sasano N, Fujita Y, Ito S, Sugiura T, Sobue K. A novel skin-traction method is effective for real-time ultrasound-guided internal jugular vein catheterization in infants and neonates weighing less than 5 kilograms. Anesth Analg. 2009;109:754–9.PubMedCrossRef Morita M, Sasano H, Azami T, Sasano N, Fujita Y, Ito S, Sugiura T, Sobue K. A novel skin-traction method is effective for real-time ultrasound-guided internal jugular vein catheterization in infants and neonates weighing less than 5 kilograms. Anesth Analg. 2009;109:754–9.PubMedCrossRef
6.
go back to reference Theodore AC, Wilson KC. An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance. Crit Care Med. 2010;38:345–6 (author reply 6–7).PubMedCrossRef Theodore AC, Wilson KC. An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance. Crit Care Med. 2010;38:345–6 (author reply 6–7).PubMedCrossRef
7.
go back to reference Ortega R, Song M, Hansen CJ, Barash P. Videos in clinical medicine. Ultrasound-guided internal jugular vein cannulation. N Engl J Med. 2010;362:e57.PubMedCrossRef Ortega R, Song M, Hansen CJ, Barash P. Videos in clinical medicine. Ultrasound-guided internal jugular vein cannulation. N Engl J Med. 2010;362:e57.PubMedCrossRef
8.
go back to reference Marcus HE, Bonkat E, Dagtekin O, Schier R, Petzke F, Wippermann J, Bottiger BW, Teschendorf P. The impact of Trendelenburg position and positive end-expiratory pressure on the internal jugular cross-sectional area. Anesth Analg. 2010;111:432–6.PubMedCrossRef Marcus HE, Bonkat E, Dagtekin O, Schier R, Petzke F, Wippermann J, Bottiger BW, Teschendorf P. The impact of Trendelenburg position and positive end-expiratory pressure on the internal jugular cross-sectional area. Anesth Analg. 2010;111:432–6.PubMedCrossRef
9.
go back to reference Sasano H, Morita M, Azami T, Ito S, Sasano N, Kato R, Hirate H, Ito H, Takeuchi A, Sobue K. Skin-traction method prevents the collapse of the internal jugular vein caused by an ultrasound probe in real-time ultrasound-assisted guidance. J Anesth. 2009;23:41–5.PubMedCrossRef Sasano H, Morita M, Azami T, Ito S, Sasano N, Kato R, Hirate H, Ito H, Takeuchi A, Sobue K. Skin-traction method prevents the collapse of the internal jugular vein caused by an ultrasound probe in real-time ultrasound-assisted guidance. J Anesth. 2009;23:41–5.PubMedCrossRef
10.
go back to reference Yoshida H, Yaguchi S, Kudo T, Ono T, Hirota K. A new method for longitudinally increasing the internal jugular vein diameter during ultrasound-guided cannulation. Anesth Analg. 2012;115:738–9.PubMedCrossRef Yoshida H, Yaguchi S, Kudo T, Ono T, Hirota K. A new method for longitudinally increasing the internal jugular vein diameter during ultrasound-guided cannulation. Anesth Analg. 2012;115:738–9.PubMedCrossRef
11.
go back to reference Maruyama K, Nakajima Y, Hayashi Y, Ohnishi Y, Kuro M. A guide to preventing deep insertion of the cannulation needle during catheterization of the internal jugular vein. J Cardiothorac Vasc Anesth. 1997;11:192–4.PubMedCrossRef Maruyama K, Nakajima Y, Hayashi Y, Ohnishi Y, Kuro M. A guide to preventing deep insertion of the cannulation needle during catheterization of the internal jugular vein. J Cardiothorac Vasc Anesth. 1997;11:192–4.PubMedCrossRef
Metadata
Title
Cannulation needle-induced anterior wall tenting of internal jugular vein causing posterior wall penetration
Authors
Hitoshi Yoshida
Shinya Yaguchi
Hiroyuki Itaya
Kazuo Ito
Ryo Hatanaka
Kishiko Nakai
Kazuyoshi Hirota
Publication date
01-06-2015
Publisher
Springer Japan
Published in
Journal of Anesthesia / Issue 3/2015
Print ISSN: 0913-8668
Electronic ISSN: 1438-8359
DOI
https://doi.org/10.1007/s00540-014-1937-0

Other articles of this Issue 3/2015

Journal of Anesthesia 3/2015 Go to the issue