Skip to main content
Top
Published in: Surgical Endoscopy 3/2020

01-03-2020 | Ultrasound

A prospective, randomized, multicenter clinical trial comparing 25-gauge and 20-gauge biopsy needles for endoscopic ultrasound-guided sampling of solid pancreatic lesions

Authors: Eunae Cho, Chang-Hwan Park, Tae Hyeon Kim, Chang-Min Cho, Dong Wan Seo, Jaihwan Kim, Jun Ho Choi, Sung-Hoon Moon

Published in: Surgical Endoscopy | Issue 3/2020

Login to get access

Abstract

Background

Various core biopsy needles have previously been developed for endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB). However, the properties of needle gauge in the diagnostic outcomes of solid pancreatic lesions remain unknown. This trial compared the procurement rates of histologic cores from solid pancreatic lesions with EUS-FNB using 20- and 25-gauge (G) FNB needles.

Methods

In a prospective randomized multicenter clinical trial, patients with solid pancreatic lesions underwent EUS-FNB with either a 20-gauge or a 25-gauge FNB needle. The rates of histologic core procurement, overall diagnostic accuracy, and adverse events were compared between the two groups (20-gauge or 25-gauge FNB needle).

Results

In total, 88 patients (48 men, 40 women, mean age 65.7 years) were enrolled. No significant differences were found in the demographic characteristics between the two groups (20-gauge or 25-gauge FNB needle). The procurement rate of histologic cores in the 20-guage FNB needle group (41/45, 91.1%) was significantly higher than that in the 25-guage FNB needle group (32/43, 74.4%, P = 0.037). However, no significant differences were found in the overall diagnostic accuracy between 20-guage FNB needle (40/45, 88.9%) and 25-guage FNB needle (34/43, 79.1%, P = 0.208). No procedure-related adverse events were observed in either group.

Conclusions

Although both FNB needles provided high overall diagnostic accuracy, the reliability of the 20-guage FNB needle is better than the 25-guage FNB needle when retrieving samples for histological analysis.
Literature
1.
go back to reference Siegel RL, Miller KD, Jemal A (2018) Cancer statistics, 2018. CA: Cancer J Clin 68:7–30 Siegel RL, Miller KD, Jemal A (2018) Cancer statistics, 2018. CA: Cancer J Clin 68:7–30
3.
go back to reference Rahib L, Smith BD, Aizenberg R, Rosenzweig AB, Fleshman JM, Matrisian LM (2014) Projecting cancer incidence and deaths to 2030: the unexpected burden of thyroid, liver, and pancreas cancers in the United States. Can Res 74:2913–2921CrossRef Rahib L, Smith BD, Aizenberg R, Rosenzweig AB, Fleshman JM, Matrisian LM (2014) Projecting cancer incidence and deaths to 2030: the unexpected burden of thyroid, liver, and pancreas cancers in the United States. Can Res 74:2913–2921CrossRef
4.
go back to reference Ooi M, Phan A, Nguyen NQ (2017) Future role of endoscopic ultrasound in personalized management of pancreatic cancer. Endosc Ultrasound 6:300–307CrossRef Ooi M, Phan A, Nguyen NQ (2017) Future role of endoscopic ultrasound in personalized management of pancreatic cancer. Endosc Ultrasound 6:300–307CrossRef
5.
go back to reference Austin MC, Smith C, Pritchard CC, Tait JF (2016) DNA yield from tissue samples in surgical pathology and minimum tissue requirements for molecular testing. Arch Pathol Lab Med 140:130–133CrossRef Austin MC, Smith C, Pritchard CC, Tait JF (2016) DNA yield from tissue samples in surgical pathology and minimum tissue requirements for molecular testing. Arch Pathol Lab Med 140:130–133CrossRef
6.
go back to reference Ngamruengphong S, Li F, Zhou Y, Chak A, Cooper GS, Das A (2010) EUS and survival in patients with pancreatic cancer: a population-based study. Gastrointestinal Endosc 72:78–83CrossRef Ngamruengphong S, Li F, Zhou Y, Chak A, Cooper GS, Das A (2010) EUS and survival in patients with pancreatic cancer: a population-based study. Gastrointestinal Endosc 72:78–83CrossRef
7.
go back to reference Othman MO, Wallace MB (2012) The role of endoscopic ultrasonography in the diagnosis and management of pancreatic cancer. Gastroenterol Clin North Am 41:179–188CrossRef Othman MO, Wallace MB (2012) The role of endoscopic ultrasonography in the diagnosis and management of pancreatic cancer. Gastroenterol Clin North Am 41:179–188CrossRef
8.
go back to reference Li H, Li W, Zhou QY, Fan B (2018) Fine needle biopsy is superior to fine needle aspiration in endoscopic ultrasound guided sampling of pancreatic masses: a meta-analysis of randomized controlled trials. Medicine 97:e0207CrossRef Li H, Li W, Zhou QY, Fan B (2018) Fine needle biopsy is superior to fine needle aspiration in endoscopic ultrasound guided sampling of pancreatic masses: a meta-analysis of randomized controlled trials. Medicine 97:e0207CrossRef
9.
go back to reference Nakai Y, Isayama H, Chang KJ, Yamamoto N, Hamada T, Uchino R, Mizuno S, Miyabayashi K, Yamamoto K, Kawakubo K, Kogure H, Sasaki T, Hirano K, Tanaka M, Tada M, Fukayama M, Koike K (2014) Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses. Dig Dis Sci 59:1578–1585CrossRef Nakai Y, Isayama H, Chang KJ, Yamamoto N, Hamada T, Uchino R, Mizuno S, Miyabayashi K, Yamamoto K, Kawakubo K, Kogure H, Sasaki T, Hirano K, Tanaka M, Tada M, Fukayama M, Koike K (2014) Slow pull versus suction in endoscopic ultrasound-guided fine-needle aspiration of pancreatic solid masses. Dig Dis Sci 59:1578–1585CrossRef
10.
go back to reference Ramesh J, Bang JY, Hebert-Magee S, Trevino J, Eltoum I, Frost A, Hasan MK, Logue A, Hawes R, Varadarajulu S (2015) Randomized trial comparing the flexible 19G and 25G needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass lesions. Pancreas 44:128–133CrossRef Ramesh J, Bang JY, Hebert-Magee S, Trevino J, Eltoum I, Frost A, Hasan MK, Logue A, Hawes R, Varadarajulu S (2015) Randomized trial comparing the flexible 19G and 25G needles for endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass lesions. Pancreas 44:128–133CrossRef
11.
go back to reference Bang JY, Hebert-Magee S, Trevino J, Ramesh J, Varadarajulu S (2012) Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 76:321–327CrossRef Bang JY, Hebert-Magee S, Trevino J, Ramesh J, Varadarajulu S (2012) Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 76:321–327CrossRef
12.
go back to reference Dumonceau JM, Deprez PH, Jenssen C, Iglesias-Garcia J, Larghi A, Vanbiervliet G, Aithal GP, Arcidiacono PG, Bastos P, Carrara S, Czako L, Fernandez-Esparrach G, Fockens P, Gines A, Havre RF, Hassan C, Vilmann P, van Hooft JE, Polkowski M (2017) Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline—Updated January 2017. Endoscopy 49:695–714CrossRef Dumonceau JM, Deprez PH, Jenssen C, Iglesias-Garcia J, Larghi A, Vanbiervliet G, Aithal GP, Arcidiacono PG, Bastos P, Carrara S, Czako L, Fernandez-Esparrach G, Fockens P, Gines A, Havre RF, Hassan C, Vilmann P, van Hooft JE, Polkowski M (2017) Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline—Updated January 2017. Endoscopy 49:695–714CrossRef
13.
go back to reference Committee AT, Hwang JH, Aslanian HR, Thosani N, Goodman A, Manfredi M, Navaneethan U, Pannala R, Parsi MA, Smith ZL, Sullivan SA, Banerjee S, Maple JT (2017) Devices for use with EUS. VideoGIE: an official video journal of the American Society for Gastrointestinal Endoscopy 2:35–45CrossRef Committee AT, Hwang JH, Aslanian HR, Thosani N, Goodman A, Manfredi M, Navaneethan U, Pannala R, Parsi MA, Smith ZL, Sullivan SA, Banerjee S, Maple JT (2017) Devices for use with EUS. VideoGIE: an official video journal of the American Society for Gastrointestinal Endoscopy 2:35–45CrossRef
14.
go back to reference Iglesias-Garcia J, Poley JW, Larghi A, Giovannini M, Petrone MC, Abdulkader I, Monges G, Costamagna G, Arcidiacono P, Biermann K, Rindi G, Bories E, Dogloni C, Bruno M, Dominguez-Munoz JE (2011) Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc 73:1189–1196CrossRef Iglesias-Garcia J, Poley JW, Larghi A, Giovannini M, Petrone MC, Abdulkader I, Monges G, Costamagna G, Arcidiacono P, Biermann K, Rindi G, Bories E, Dogloni C, Bruno M, Dominguez-Munoz JE (2011) Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study. Gastrointest Endosc 73:1189–1196CrossRef
15.
go back to reference Park SW, Chung MJ, Lee SH, Lee HS, Lee HJ, Park JY, Park SW, Song SY, Kim H, Chung JB, Bang S (2016) Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses. PLoS ONE 11:e0154401CrossRef Park SW, Chung MJ, Lee SH, Lee HS, Lee HJ, Park JY, Park SW, Song SY, Kim H, Chung JB, Bang S (2016) Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses. PLoS ONE 11:e0154401CrossRef
16.
go back to reference Iwashita T, Nakai Y, Samarasena JB, Park DH, Zhang Z, Gu M, Lee JG, Chang KJ (2013) High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions. Gastrointest Endosc 77:909–915CrossRef Iwashita T, Nakai Y, Samarasena JB, Park DH, Zhang Z, Gu M, Lee JG, Chang KJ (2013) High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions. Gastrointest Endosc 77:909–915CrossRef
17.
go back to reference Larghi A, Iglesias-Garcia J, Poley JW, Monges G, Petrone MC, Rindi G, Abdulkader I, Arcidiacono PG, Costamagna G, Biermann K, Bories E, Doglioni C, Dominguez-Munoz JE, Hassan C, Bruno M, Giovannini M (2013) Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study. Surg Endosc 27:3733–3738CrossRef Larghi A, Iglesias-Garcia J, Poley JW, Monges G, Petrone MC, Rindi G, Abdulkader I, Arcidiacono PG, Costamagna G, Biermann K, Bories E, Doglioni C, Dominguez-Munoz JE, Hassan C, Bruno M, Giovannini M (2013) Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study. Surg Endosc 27:3733–3738CrossRef
18.
go back to reference Nishioka N, Ogura T, Kurisu Y, Imanishi M, Onda S, Takagi W, Sano T, Okuda A, Miyano A, Amano M, Higuchi K (2018) Prospective histological evaluation of a 20G core trap with a forward-cutting bevel needle for EUS-FNA of pancreatic lesions. Surg Endosc 32:4125–4131CrossRef Nishioka N, Ogura T, Kurisu Y, Imanishi M, Onda S, Takagi W, Sano T, Okuda A, Miyano A, Amano M, Higuchi K (2018) Prospective histological evaluation of a 20G core trap with a forward-cutting bevel needle for EUS-FNA of pancreatic lesions. Surg Endosc 32:4125–4131CrossRef
19.
go back to reference Antonini F, Delconte G, Fuccio L, De Nucci G, Fabbri C, Armellini E, Frazzoni L, Fornelli A, Magarotto A, Mandelli E, Occhipinti P, Masci E, Manes G, Macarri G (2018) EUS-guided tissue sampling with a 20-gauge core biopsy needle for the characterization of gastrointestinal subepithelial lesions: a multicenter study. Endosc Ultrasound 8:105CrossRef Antonini F, Delconte G, Fuccio L, De Nucci G, Fabbri C, Armellini E, Frazzoni L, Fornelli A, Magarotto A, Mandelli E, Occhipinti P, Masci E, Manes G, Macarri G (2018) EUS-guided tissue sampling with a 20-gauge core biopsy needle for the characterization of gastrointestinal subepithelial lesions: a multicenter study. Endosc Ultrasound 8:105CrossRef
20.
go back to reference Khan MA, Grimm IS, Ali B, Nollan R, Tombazzi C, Ismail MK, Baron TH (2017) A meta-analysis of endoscopic ultrasound-fine-needle aspiration compared to endoscopic ultrasound-fine-needle biopsy: diagnostic yield and the value of onsite cytopathological assessment. Endosc Int Open 5:E363–E375CrossRef Khan MA, Grimm IS, Ali B, Nollan R, Tombazzi C, Ismail MK, Baron TH (2017) A meta-analysis of endoscopic ultrasound-fine-needle aspiration compared to endoscopic ultrasound-fine-needle biopsy: diagnostic yield and the value of onsite cytopathological assessment. Endosc Int Open 5:E363–E375CrossRef
Metadata
Title
A prospective, randomized, multicenter clinical trial comparing 25-gauge and 20-gauge biopsy needles for endoscopic ultrasound-guided sampling of solid pancreatic lesions
Authors
Eunae Cho
Chang-Hwan Park
Tae Hyeon Kim
Chang-Min Cho
Dong Wan Seo
Jaihwan Kim
Jun Ho Choi
Sung-Hoon Moon
Publication date
01-03-2020
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 3/2020
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-019-06903-x

Other articles of this Issue 3/2020

Surgical Endoscopy 3/2020 Go to the issue