Skip to main content
Top
Published in: Surgical Endoscopy 10/2016

01-10-2016

The usefulness of 3-dimensional endoscope systems in endoscopic surgery

Authors: Hiroyuki Egi, Minoru Hattori, Takahisa Suzuki, Hiroyuki Sawada, Yuichi Kurita, Hideki Ohdan

Published in: Surgical Endoscopy | Issue 10/2016

Login to get access

Abstract

Background

The image quality and performance of 3-dimensional video image systems has improved along with improvements in technology. However, objective evaluation on the usefulness of 3-dimensional video image systems is insufficient. Therefore, we decided to investigate the usefulness of 3-dimensional video image systems using the objective endoscopic surgery technology evaluating apparatus that we have developed, the Hiroshima University Endoscopic Surgical Assessment Device (HUESAD).

Methods

The participants were 28 student volunteers enrolled in Hiroshima University (17 men and 11 women, age: median 22.5, range 20–25), with no one having experienced endoscopic surgery training. Testing was carried out by dividing the subjects into two groups to initially carry out HUESAD with 2-dimensional video imaging (N = 14) and with 3-dimensional video imaging (N = 14). Questionnaires were carried out along with the investigation regarding both 2-dimensional and 3-dimensional video imaging. The task was carried out for approximately 15 min regarding both 2-dimensional and 3-dimensional video imaging. Lastly, the Mental Rotation Test, which is a standard space perception ability test, was used to evaluate the space perception ability.

Results

No difference was observed in the nauseous and uncomfortable feeling of practitioners between the two groups. Regarding smoothness, no difference was observed between 2-dimensional and 3-dimensional video imaging (p = 0.8665). Deviation (space perception ability) and approaching time (accuracy) were significantly lower with 3-dimensional video imaging compared to 2-dimensional video imaging. Moreover, the approaching time (accuracy) significantly improved in 3-dimensional video imaging compared to 2-dimensional video imaging in the group with low space perception ability (p = 0.0085).

Conclusion

Objective evaluation using HUESAD and subjective evaluation by questionnaire revealed that endoscopic surgery techniques significantly improved in 3-dimensional video imaging compared to 2-dimensional video imaging. Moreover, it is believed that this effect is more effective in people with low space perception ability and beginner students.
Literature
1.
go back to reference Hanna GB, Shimi SM, Cuschieri A (1998) Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy. Lancet 351:248–251CrossRefPubMed Hanna GB, Shimi SM, Cuschieri A (1998) Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy. Lancet 351:248–251CrossRefPubMed
2.
go back to reference Chan AC, Chung SC, Yim AP, Lau JY, Ng EK, Li AK (1997) Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery. Surg Endosc 11:438–440CrossRefPubMed Chan AC, Chung SC, Yim AP, Lau JY, Ng EK, Li AK (1997) Comparison of two-dimensional vs three-dimensional camera systems in laparoscopic surgery. Surg Endosc 11:438–440CrossRefPubMed
3.
go back to reference Herron DM, Lantis JC 2nd, Maykel J, Basu C, Schwaitzberg SD (1999) The 3-D monitor and head-mounted display. A quantitative evaluation of advanced laparoscopic viewing technologies. Surg Endosc 13(751–755):1999 Herron DM, Lantis JC 2nd, Maykel J, Basu C, Schwaitzberg SD (1999) The 3-D monitor and head-mounted display. A quantitative evaluation of advanced laparoscopic viewing technologies. Surg Endosc 13(751–755):1999
4.
go back to reference Hanna GB, Cuschieri A (2000) Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing. World J Surg 24: 444–448, discussion 448–449 Hanna GB, Cuschieri A (2000) Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing. World J Surg 24: 444–448, discussion 448–449
5.
go back to reference Wilhelm D, Reiser S, Kohn N, Witte M, Leiner U, Mühlbach L, Ruschin D, Reiner W, Feussner H (2014) Comparative evaluation of HD 2D/3D laparoscopic monitors and benchmarking to a theoretically ideal 3D pseudodisplay: even well-experienced laparoscopists perform better with 3D. Surg Endosc 28:2387–2397CrossRefPubMed Wilhelm D, Reiser S, Kohn N, Witte M, Leiner U, Mühlbach L, Ruschin D, Reiner W, Feussner H (2014) Comparative evaluation of HD 2D/3D laparoscopic monitors and benchmarking to a theoretically ideal 3D pseudodisplay: even well-experienced laparoscopists perform better with 3D. Surg Endosc 28:2387–2397CrossRefPubMed
6.
go back to reference Feng C, Rozenblit JW, Hamilton AJ (2010) A computerized assessment to compare the impact of standard, stereoscopic, and high-definition laparoscopic monitor displays on surgical technique. Surg Endosc 24:2743–2748CrossRefPubMed Feng C, Rozenblit JW, Hamilton AJ (2010) A computerized assessment to compare the impact of standard, stereoscopic, and high-definition laparoscopic monitor displays on surgical technique. Surg Endosc 24:2743–2748CrossRefPubMed
7.
go back to reference Cicione A, Autorino R, Breda A, De Sio M, Damiano R, Fusco F, Greco F, Carvalho-Dias E, Mota P, Nogueira C, Pinho P, Mirone V, Correia-Pinto J, Rassweiler J, Lima E (2013) Three-dimensional vs standard laparoscopy: comparative assessment using a validated program for laparoscopic urologic skills. Urology 82:1444–1450CrossRefPubMed Cicione A, Autorino R, Breda A, De Sio M, Damiano R, Fusco F, Greco F, Carvalho-Dias E, Mota P, Nogueira C, Pinho P, Mirone V, Correia-Pinto J, Rassweiler J, Lima E (2013) Three-dimensional vs standard laparoscopy: comparative assessment using a validated program for laparoscopic urologic skills. Urology 82:1444–1450CrossRefPubMed
8.
go back to reference Egi H, Hattori M, Suzuki T, Sawada H, Ohdan H (2015) The significance of spatial cognitive ability in robot-assited surgery. Surg Endosc 29:1130–1136CrossRefPubMed Egi H, Hattori M, Suzuki T, Sawada H, Ohdan H (2015) The significance of spatial cognitive ability in robot-assited surgery. Surg Endosc 29:1130–1136CrossRefPubMed
9.
go back to reference Yurko YY, Scerbo MW, Prabhu AS, Acker CE, Stefanidis D (2010) Higher mental workload is associated with poorer laparoscopic performance as measured by the NASA-TLX tool, simulation in healthcare. J Soc Simul Healthc 5:267–271CrossRef Yurko YY, Scerbo MW, Prabhu AS, Acker CE, Stefanidis D (2010) Higher mental workload is associated with poorer laparoscopic performance as measured by the NASA-TLX tool, simulation in healthcare. J Soc Simul Healthc 5:267–271CrossRef
10.
11.
go back to reference Egi H, Okajima M, Kawahara T, Yoshimitsu M, Sumitani D, Tokunaga M, Takeda H, Itamoto T, Ohdan H (2010) Scientific assessment of endoscopic surgical skills. Minim Invasive Ther Allied Technol 19:30–34CrossRefPubMed Egi H, Okajima M, Kawahara T, Yoshimitsu M, Sumitani D, Tokunaga M, Takeda H, Itamoto T, Ohdan H (2010) Scientific assessment of endoscopic surgical skills. Minim Invasive Ther Allied Technol 19:30–34CrossRefPubMed
12.
go back to reference Egi H, Okajima M, Yoshimitsu M, Ikeda S, Miyata Y, Masugami H, Kawahara T, Kurita Y, Kaneko M, Asahara T (2008) Objective assessment of endoscopic surgical skills by analyzing direction-dependent dexterity using the hiroshima university endoscopic surgical assessment device (HUESAD). Surg Today 38:705–710CrossRefPubMed Egi H, Okajima M, Yoshimitsu M, Ikeda S, Miyata Y, Masugami H, Kawahara T, Kurita Y, Kaneko M, Asahara T (2008) Objective assessment of endoscopic surgical skills by analyzing direction-dependent dexterity using the hiroshima university endoscopic surgical assessment device (HUESAD). Surg Today 38:705–710CrossRefPubMed
13.
go back to reference Tokunaga M, Egi H, Hattori M, Yoshimitsu M, Sumitani D, Kawahara T, Okajima M, Ohdan H (2012) Approaching time is important for assessment of endoscopic surgical skills. Minim Invasive Ther Allied Technol 21:142–149CrossRefPubMed Tokunaga M, Egi H, Hattori M, Yoshimitsu M, Sumitani D, Kawahara T, Okajima M, Ohdan H (2012) Approaching time is important for assessment of endoscopic surgical skills. Minim Invasive Ther Allied Technol 21:142–149CrossRefPubMed
14.
go back to reference Egi H, Tokunaga M, Hattori M, Ohdan H (2013) Evaluating the correlation between the HUESAD and OSATS scores: concurrent validity study. Minim Invasive Ther Allied Technol 22:144–149CrossRefPubMed Egi H, Tokunaga M, Hattori M, Ohdan H (2013) Evaluating the correlation between the HUESAD and OSATS scores: concurrent validity study. Minim Invasive Ther Allied Technol 22:144–149CrossRefPubMed
15.
go back to reference Votanopoulos K, Brunicardi FC, Thornby J, Bellows CF (2008) Impact of three-dimensional vision in laparoscopic training. World J Surg 32:110–118CrossRefPubMed Votanopoulos K, Brunicardi FC, Thornby J, Bellows CF (2008) Impact of three-dimensional vision in laparoscopic training. World J Surg 32:110–118CrossRefPubMed
16.
go back to reference Bilgen K, Ustun M, Karakahya M, Işik S, Sengül S, Cetinkünar S, Küçükpinar TH (2013) Comparison of 3D imaging and 2D imaging for performance time of laparoscopic cholecystectomy. Surg Laparosc Endosc Percutan Techn 23:180–183CrossRef Bilgen K, Ustun M, Karakahya M, Işik S, Sengül S, Cetinkünar S, Küçükpinar TH (2013) Comparison of 3D imaging and 2D imaging for performance time of laparoscopic cholecystectomy. Surg Laparosc Endosc Percutan Techn 23:180–183CrossRef
Metadata
Title
The usefulness of 3-dimensional endoscope systems in endoscopic surgery
Authors
Hiroyuki Egi
Minoru Hattori
Takahisa Suzuki
Hiroyuki Sawada
Yuichi Kurita
Hideki Ohdan
Publication date
01-10-2016
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 10/2016
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-016-4793-1

Other articles of this Issue 10/2016

Surgical Endoscopy 10/2016 Go to the issue