Skip to main content
Top
Published in: Surgical Endoscopy 6/2015

01-06-2015

Effects of experience and reference tools on laparoscopic length measurements

Authors: Hope T. Jackson, Sara L. Zettervall, Ezra N. Teitelbaum, Matt Holzner, Jason Weissler, Richard L. Amdur, Khashayar Vaziri

Published in: Surgical Endoscopy | Issue 6/2015

Login to get access

Abstract

Introduction

The accuracy of surgeons, and surgeons-in-training performing laparoscopic intestinal measurements is unknown. We evaluated the accuracy and precision of laparoscopic length measurements using a box-trainer model with and without the aid of a measuring tool.

Methods

Surgical attendings, residents, and medical students were studied. A 500 cm length of rope was placed within a laparoscopic box trainer. Subjects completed two length measurements (LM). Participants measured 150 cm of rope for LM #1 and repeated the task using a 10-cm suture as a reference for LM #2. Measurement accuracy was tested by comparing mean LM between training level groups using an independent t test. Measurement precision was tested by comparing the mean deviation of LM from 150 cm.

Results

40 attendings, 40 residents, and 50 medical students were studied. In LM #1, there were no differences in mean length accuracy measured between training level groups. Residents significantly underestimated the true 150 cm length (p < 0.05). When LM #1 and LM #2 were compared, attending accuracy did not change but precision increased significantly (p < 0.01). Resident precision also significantly increased with the measuring tool (p < 0.001) and trended toward improved accuracy (p = 0.08). Student accuracy did not change, but a similar significant increase in precision was observed with the measurement tool (p = 0.001). Attendings performed both measurements faster than residents and students (p < 0.05). Residents performed faster than the students for both measurements (p < 0.05). Time for task completion significantly increased in medical students with the use of the measurement tool (p = 0.026).

Conclusions

These data suggest that use of a measurement tool in laparoscopic length measurement will yield better precision with no effect on operative time or procedural flow in more experienced operators. Standardization of methods of use and optimal training techniques remains to be determined.
Literature
1.
go back to reference Inabnet WB, Quinn T, Gagner M, Urban M, Pomp A (2005) Laparoscopic Roux-en-Y gastric bypass in patients with BMI < 50: a prospective randomized trial comparing short and long limb lengths. Obes Surg 15(1):51–57CrossRefPubMed Inabnet WB, Quinn T, Gagner M, Urban M, Pomp A (2005) Laparoscopic Roux-en-Y gastric bypass in patients with BMI < 50: a prospective randomized trial comparing short and long limb lengths. Obes Surg 15(1):51–57CrossRefPubMed
2.
go back to reference Swartz DE, Mobley E, Felix EL (2009) Bile reflux after Roux-en-Y gastric bypass: an unrecognized cause of postoperative pain. Surg Obes Dis 5(1):27–30CrossRef Swartz DE, Mobley E, Felix EL (2009) Bile reflux after Roux-en-Y gastric bypass: an unrecognized cause of postoperative pain. Surg Obes Dis 5(1):27–30CrossRef
3.
go back to reference Teitelbaum EN, Vaziri K, Zettervall S, Amdur RL, Orkin BA (2013) Intraoperative small bowel length measurements and analysis of demographic predictors of increased length. Clin Anat 26(7):827–832PubMed Teitelbaum EN, Vaziri K, Zettervall S, Amdur RL, Orkin BA (2013) Intraoperative small bowel length measurements and analysis of demographic predictors of increased length. Clin Anat 26(7):827–832PubMed
4.
go back to reference Bittner JG, Hathaway CA, Brown JA (2008) Three-dimensional visualisation and articulating instrumentation: impact on simulated laparoscopic tasks. J Minim Access Surg 4:31–38CrossRefPubMed Bittner JG, Hathaway CA, Brown JA (2008) Three-dimensional visualisation and articulating instrumentation: impact on simulated laparoscopic tasks. J Minim Access Surg 4:31–38CrossRefPubMed
5.
go back to reference Swanstrom LL, Soper NJ (2013) Mastery of endoscopic and laparoscopic surgery, 4th edn. Lippincott Wiliams & Wilkins, Philadelphia Swanstrom LL, Soper NJ (2013) Mastery of endoscopic and laparoscopic surgery, 4th edn. Lippincott Wiliams & Wilkins, Philadelphia
6.
go back to reference Schauer PR, Schirmer BD, Brethauer SA (2007) Minimally invasive bariatric surgery. Springer, New YorkCrossRef Schauer PR, Schirmer BD, Brethauer SA (2007) Minimally invasive bariatric surgery. Springer, New YorkCrossRef
7.
go back to reference Stefanidis D, Kuwada TS, Gersin KS (2011) The importance of the length of the limbs for gastric bypass patients—an evidence-based review. Obes Surg 21(1):119–124CrossRefPubMed Stefanidis D, Kuwada TS, Gersin KS (2011) The importance of the length of the limbs for gastric bypass patients—an evidence-based review. Obes Surg 21(1):119–124CrossRefPubMed
8.
go back to reference Isreb S, Hildreth AJ, Mahawar K, Small P (2009) Laparoscopic instruments marking improve length measuring precision. World J Laparosc Surg 2:57–60CrossRef Isreb S, Hildreth AJ, Mahawar K, Small P (2009) Laparoscopic instruments marking improve length measuring precision. World J Laparosc Surg 2:57–60CrossRef
9.
go back to reference McCluney AL, Vassiliou MC, Kaneva PA, Cao J, Stanbridge DD, Feldman LS, Fried GM (2005) FLS FLS simulator performance predicts intraoperative laparoscopic skills. Surg Endosc 19:1572–1578CrossRef McCluney AL, Vassiliou MC, Kaneva PA, Cao J, Stanbridge DD, Feldman LS, Fried GM (2005) FLS FLS simulator performance predicts intraoperative laparoscopic skills. Surg Endosc 19:1572–1578CrossRef
10.
go back to reference Sroka G, Feldman LS, Vassiliou MC, Kaneva PA, Fayez R, Fried GM (2010) Fundamentals of laparoscopic surgery simulator training to proficiency improves laparoscopic performance in the operating room-a randomized controlled trial. Am J Surg 199(1):115–120CrossRefPubMed Sroka G, Feldman LS, Vassiliou MC, Kaneva PA, Fayez R, Fried GM (2010) Fundamentals of laparoscopic surgery simulator training to proficiency improves laparoscopic performance in the operating room-a randomized controlled trial. Am J Surg 199(1):115–120CrossRefPubMed
11.
go back to reference Van Sickle KR, Ritter EM, Smith CD (2006) The pretrained novice: using simulation-based training to improve learning in the operating room. Surg Innov 13(3):198–204CrossRefPubMed Van Sickle KR, Ritter EM, Smith CD (2006) The pretrained novice: using simulation-based training to improve learning in the operating room. Surg Innov 13(3):198–204CrossRefPubMed
12.
go back to reference Korndorffer JR Jr, Dunne JB, Sierra R, Stefanidis D, Touchard CL, Scott DJ (2005) Simulator training for laparoscopic suturing using performance goals translates to the operating room. J Am Coll Surg 201(1):23–29CrossRefPubMed Korndorffer JR Jr, Dunne JB, Sierra R, Stefanidis D, Touchard CL, Scott DJ (2005) Simulator training for laparoscopic suturing using performance goals translates to the operating room. J Am Coll Surg 201(1):23–29CrossRefPubMed
13.
go back to reference Sturm LP, Windsor JA, Cosman PH, Cregan P, Hewett PJ, Maddern GJ (2008) A systematic review of skills transfer after surgical simulation training. Ann surg 248(2):166–179CrossRefPubMed Sturm LP, Windsor JA, Cosman PH, Cregan P, Hewett PJ, Maddern GJ (2008) A systematic review of skills transfer after surgical simulation training. Ann surg 248(2):166–179CrossRefPubMed
Metadata
Title
Effects of experience and reference tools on laparoscopic length measurements
Authors
Hope T. Jackson
Sara L. Zettervall
Ezra N. Teitelbaum
Matt Holzner
Jason Weissler
Richard L. Amdur
Khashayar Vaziri
Publication date
01-06-2015
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 6/2015
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-014-3802-5

Other articles of this Issue 6/2015

Surgical Endoscopy 6/2015 Go to the issue