Background

Research in computer vision and mobile robotics has developed a family of popular algorithms known as Visual Simultaneous Localization And Mapping (Visual SLAM). These algorithms can provide 3D models of body cavities using the images obtained from standard monocular endoscopes. The 3D models can be used to estimate hernia defect measurements during laparoscopic ventral hernia repair (LVHR).

Methods

We conducted a descriptive and comparative prospective study to analyze results from 15 patients who underwent LVHR. Three methods of measurement were used in each patient: two classical methods (needle and tape) and a new visual SLAM measurement (VSM) method. The major and minor axes of the ellipse-shaped hernia defect were measured.

Results

Both axes could be measured using the VSM method in all patients except one (93 %). The tape method measured 63 % of the axes, but was difficult to perform because of patient comorbidities and because of limited range of motion of the laparoscopic tools. The needle method obtained 73 % of measurements, because of patient comorbidities. The tape method was the most accurate (accuracy up to 0.5 cm because of tape resolution). The needle method was relatively inaccurate, with a mean error of >3 cm. The VSM method was as accurate as the tape method. The mean time taken to perform measurements was 40 s for the VSM method (range 29–60 s), 169 s for the needle method (range 66–300 s), and 186 s for the tape method (range 110–322 s).

Conclusions

The needle method is relatively inaccurate and invasive. The tape method is accurate, but is not easy to perform and is relatively time consuming. The VSM method is noninvasive and fast and is as accurate as the tape method.
Appendix
Available only for authorised users
Literature
1.
go back to reference Mudge M, Hughes LE (1985) Incisional hernia: a 10 year prospective study of incidence and attitudes. Br J Surg 72:70–71PubMedCrossRef Mudge M, Hughes LE (1985) Incisional hernia: a 10 year prospective study of incidence and attitudes. Br J Surg 72:70–71PubMedCrossRef
2.
go back to reference Santora TA, Roslyn JJ (1993) Incisional hernia. Surg Clin N Am 73:557–570PubMed Santora TA, Roslyn JJ (1993) Incisional hernia. Surg Clin N Am 73:557–570PubMed
3.
go back to reference Banerjee A, Beck C, Narula VK, Linn J, Noria S, Zagol B, Mikami DJ (2012) Laparoscopic ventral hernia repair: does primary repair in addition to placement of mesh decrease recurrence? Surg Endosc 26:1264–1268. doi:10.1007/s00464-011-2024-3 PubMedCrossRef Banerjee A, Beck C, Narula VK, Linn J, Noria S, Zagol B, Mikami DJ (2012) Laparoscopic ventral hernia repair: does primary repair in addition to placement of mesh decrease recurrence? Surg Endosc 26:1264–1268. doi:10.​1007/​s00464-011-2024-3 PubMedCrossRef
4.
go back to reference LeBlanc KA, Booth WV (1993) Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 3:39–41PubMed LeBlanc KA, Booth WV (1993) Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 3:39–41PubMed
5.
go back to reference LeBlanc KA, Whitaker JM, Bellanger DE, Rhynes VK (2003) Laparoscopic incisional and ventral hernioplasty: lessons learned from 200 patients. Hernia 7:118–124PubMedCrossRef LeBlanc KA, Whitaker JM, Bellanger DE, Rhynes VK (2003) Laparoscopic incisional and ventral hernioplasty: lessons learned from 200 patients. Hernia 7:118–124PubMedCrossRef
6.
go back to reference LeBlanc KA (2007) Laparoscopic incisional hernia repair: are transfacial sutures necessary? A review of the literature. Surg Endosc 21:508–513PubMedCrossRef LeBlanc KA (2007) Laparoscopic incisional hernia repair: are transfacial sutures necessary? A review of the literature. Surg Endosc 21:508–513PubMedCrossRef
7.
go back to reference Morales-Conde S, Cadet H, Cano A, Bustos M, Martín J, Morales-Mendez S (2005) Laparoscopic ventral hernia repair without sutures double crown technique: our experience after 140 cases with a mean follow-up of 40 months. Int Surg 90(3 Suppl):S56–S62PubMed Morales-Conde S, Cadet H, Cano A, Bustos M, Martín J, Morales-Mendez S (2005) Laparoscopic ventral hernia repair without sutures double crown technique: our experience after 140 cases with a mean follow-up of 40 months. Int Surg 90(3 Suppl):S56–S62PubMed
8.
10.
13.
go back to reference Grasa OG, Civera J, Montiel JMM (2011) EKF monocular SLAM with relocalization for laparoscopic sequences. In: IEEE international conference on robotics and automation (ICRA11). doi:10.1109/ICRA.2011.5980059 Grasa OG, Civera J, Montiel JMM (2011) EKF monocular SLAM with relocalization for laparoscopic sequences. In: IEEE international conference on robotics and automation (ICRA11). doi:10.​1109/​ICRA.​2011.​5980059
14.
go back to reference Gil I, Marín J, Martínez JM, Bernal E, Casado S, García O, Quintana J (2011) Augmented Reality and 3D Measurement for Monocular Laparoscopic Abdominal Wall Hernia Repair. 46th Congress of the European Society for Surgical Research (ESSR11). Oral Sess Br J Surg 98:1–48. doi:10.1002/bjs.7577 Gil I, Marín J, Martínez JM, Bernal E, Casado S, García O, Quintana J (2011) Augmented Reality and 3D Measurement for Monocular Laparoscopic Abdominal Wall Hernia Repair. 46th Congress of the European Society for Surgical Research (ESSR11). Oral Sess Br J Surg 98:1–48. doi:10.​1002/​bjs.​7577
Metadata
Title
Computer vision distance measurement from endoscopic sequences: prospective evaluation in laparoscopic ventral hernia repair
Authors
Ernesto Bernal
Santiago Casado
Óscar G. Grasa
J. M. M. Montiel
Ismael Gil
Publication date
01-12-2014
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 12/2014
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-014-3632-5

Other articles of this Issue 12/2014

Surgical Endoscopy 12/2014 Go to the issue