Skip to main content
Top
Published in: Surgical Endoscopy 9/2014

01-09-2014 | Review

Intraoperative assessment of colorectal anastomotic integrity: a systematic review

Authors: Subramanian Nachiappan, Alan Askari, Andrew Currie, Robin H. Kennedy, Omar Faiz

Published in: Surgical Endoscopy | Issue 9/2014

Login to get access

Abstract

Background

Surgeons have attempted to minimize postoperative anastomotic complications by employing intraoperative tests and manoeuvres to assess colorectal anastomotic integrity. These have evolved over time with improvement in operative technology and techniques. This systematic review aims to examine the impact of such intraoperative assessments.

Methods

A systematic review of studies assessing intraoperative anastomotic assessments and their impact on postoperative anastomotic complications was performed. Intraoperative measures undertaken as a result of intraoperative assessments and postoperative anastomotic complications were analysed.

Results

37 Studies were identified. 13 studies evaluated basic mechanical patency tests, ten studies evaluated endoscopic visualisation techniques and 14 studies evaluated microperfusion techniques. Postoperative anastomotic complications were significantly lower in patients tested with basic mechanical patency tests compared to those untested (non-RCT: 4.1 vs. 8.1 %, p = 0.03, RCTs: 5.8 vs. 16.0 %, p = 0.024). There were no differences in postoperative anastomotic complications between tested and non-tested cohorts in non-randomised cohort studies evaluating endoscopic visualisation techniques. However, intraoperative measures taken after abnormal intraoperative tests may have reduced the number of postoperative complications. Perfusion analysis techniques are not in routine widespread clinical practice as yet, but newer techniques such as fluorescent dyes and imaging under near infrared light show technical feasibility.

Conclusions

Intraoperative colorectal anastomotic assessment has evolved together with advancement of technology in the surgical setting. Moderate benefit in terms of lower postoperative anastomotic complications has been shown with basic mechanical patency testing and more recently with intraoperative endoscopic visualisation of colorectal anastomoses. The next advance and possible introduction into routine practice may include the use of microperfusion techniques. The latest in this group of techniques, which utilise autofluorescent dyes such as Indocyanine green, hold great potential. Well-planned controlled studies or ideally, randomised controlled trials need to be conducted to further assess the benefit of these latest techniques.
Literature
1.
go back to reference Den Dulk M, Marijnen CAM, Collette L, Putter H, Påhlman L, Folkesson J, Bosset J-F, Rödel C, Bujko K, van de Velde CJH (2009) Multicentre analysis of oncological and survival outcomes following anastomotic leakage after rectal cancer surgery. Br J Surg 96:1066–1075. doi:10.1002/bjs.6694 CrossRef Den Dulk M, Marijnen CAM, Collette L, Putter H, Påhlman L, Folkesson J, Bosset J-F, Rödel C, Bujko K, van de Velde CJH (2009) Multicentre analysis of oncological and survival outcomes following anastomotic leakage after rectal cancer surgery. Br J Surg 96:1066–1075. doi:10.​1002/​bjs.​6694 CrossRef
2.
go back to reference Mirnezami A, Mirnezami R, Chandrakumaran K, Sasapu K, Sagar P, Finan P (2011) Increased local recurrence and reduced survival from colorectal cancer following anastomotic leak: systematic review and meta-analysis. Ann Surg 253:890–899. doi:10.1097/SLA.0b013e3182128929 PubMedCrossRef Mirnezami A, Mirnezami R, Chandrakumaran K, Sasapu K, Sagar P, Finan P (2011) Increased local recurrence and reduced survival from colorectal cancer following anastomotic leak: systematic review and meta-analysis. Ann Surg 253:890–899. doi:10.​1097/​SLA.​0b013e3182128929​ PubMedCrossRef
3.
go back to reference Park JS, Choi G-S, Kim SH, Kim HR, Kim NK, Lee KY, Kang SB, Kim JY, Lee KY, Kim BC, Bae BN, Son GM, Lee S, Kang H (2013) Multicenter analysis of risk factors for anastomotic leakage after laparoscopic rectal cancer excision: the Korean laparoscopic colorectal surgery study group. Ann Surg 257(4):665–671. doi:10.1097/SLA.0b013e31827b8ed9 PubMedCrossRef Park JS, Choi G-S, Kim SH, Kim HR, Kim NK, Lee KY, Kang SB, Kim JY, Lee KY, Kim BC, Bae BN, Son GM, Lee S, Kang H (2013) Multicenter analysis of risk factors for anastomotic leakage after laparoscopic rectal cancer excision: the Korean laparoscopic colorectal surgery study group. Ann Surg 257(4):665–671. doi:10.​1097/​SLA.​0b013e31827b8ed9​ PubMedCrossRef
6.
go back to reference Buchs NC, Gervaz P, Secic M, Bucher P, Mugnier-Konrad B, Morel P (2008) Incidence, consequences, and risk factors for anastomotic dehiscence after colorectal surgery: a prospective monocentric study. Int J Colorectal Dis 23:265–270. doi:10.1007/s00384-007-0399-3 PubMedCrossRef Buchs NC, Gervaz P, Secic M, Bucher P, Mugnier-Konrad B, Morel P (2008) Incidence, consequences, and risk factors for anastomotic dehiscence after colorectal surgery: a prospective monocentric study. Int J Colorectal Dis 23:265–270. doi:10.​1007/​s00384-007-0399-3 PubMedCrossRef
7.
go back to reference Law WI, Chu KW, Ho JW, Chan CW (2000) Risk factors for anastomotic leakage after low anterior resection with total mesorectal excision. Am J Surg 179:92–96PubMedCrossRef Law WI, Chu KW, Ho JW, Chan CW (2000) Risk factors for anastomotic leakage after low anterior resection with total mesorectal excision. Am J Surg 179:92–96PubMedCrossRef
8.
go back to reference Moran BJ (2010) Predicting the risk and diminishing the consequences of anastomotic leakage after anterior resection for rectal cancer. Acta Chir Iugosl 57:47–50PubMedCrossRef Moran BJ (2010) Predicting the risk and diminishing the consequences of anastomotic leakage after anterior resection for rectal cancer. Acta Chir Iugosl 57:47–50PubMedCrossRef
11.
14.
go back to reference Lazorthes F, Chiotassol P (1986) Stapled colorectal anastomoses: peroperative integrity of the anastomosis and risk of postoperative leakage. Int J Colorectal Dis 1:96–98PubMedCrossRef Lazorthes F, Chiotassol P (1986) Stapled colorectal anastomoses: peroperative integrity of the anastomosis and risk of postoperative leakage. Int J Colorectal Dis 1:96–98PubMedCrossRef
15.
go back to reference Davies AH, Bartolo DC, Richards AE, Johnson CD, Mortensen MCC (1988) Intra-operative air testing: an audit on rectal anastomosis. Ann R Coll Surg Engl 70:345–347PubMedCentralPubMed Davies AH, Bartolo DC, Richards AE, Johnson CD, Mortensen MCC (1988) Intra-operative air testing: an audit on rectal anastomosis. Ann R Coll Surg Engl 70:345–347PubMedCentralPubMed
16.
go back to reference Griffith CD, Hardcastle JD (1990) Intraoperative testing of anastomotic integrity after stapled anterior resection for cancer. J R Coll Surg Edinb 35:106–108PubMed Griffith CD, Hardcastle JD (1990) Intraoperative testing of anastomotic integrity after stapled anterior resection for cancer. J R Coll Surg Edinb 35:106–108PubMed
17.
go back to reference Pritchard GA, Krouma FF, Stamatakis JD (1990) Short note Intraoperative testing of colorectal anastomosis can be misleading. 77:101105 Pritchard GA, Krouma FF, Stamatakis JD (1990) Short note Intraoperative testing of colorectal anastomosis can be misleading. 77:101105
18.
go back to reference Dixon AR, Holmes JT (1991) Colorectal anastomotic integrity after anterior resection: is there a role for intraoperative testing? J R Coll Surg Edinb 36:35–36PubMed Dixon AR, Holmes JT (1991) Colorectal anastomotic integrity after anterior resection: is there a role for intraoperative testing? J R Coll Surg Edinb 36:35–36PubMed
19.
go back to reference Yalin R, Aktan AO, Yeğen C, Döşlüoğlu H, Okboy N (1993) Importance of testing stapled rectal anastomoses with air. Eur J Surg 159:49–51PubMed Yalin R, Aktan AO, Yeğen C, Döşlüoğlu H, Okboy N (1993) Importance of testing stapled rectal anastomoses with air. Eur J Surg 159:49–51PubMed
20.
go back to reference Gilbert JM, Trapnell JE (1988) Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training. Ann R Coll Surg Engl 70:158–160PubMedCentralPubMed Gilbert JM, Trapnell JE (1988) Intraoperative testing of the integrity of left-sided colorectal anastomoses: a technique of value to the surgeon in training. Ann R Coll Surg Engl 70:158–160PubMedCentralPubMed
21.
go back to reference Wheeler JM, Gilbert JM (1999) Controlled intraoperative water testing of left-sided colorectal anastomoses: are ileostomies avoidable? Ann R Coll Surg Engl 81:105–108PubMedCentralPubMed Wheeler JM, Gilbert JM (1999) Controlled intraoperative water testing of left-sided colorectal anastomoses: are ileostomies avoidable? Ann R Coll Surg Engl 81:105–108PubMedCentralPubMed
23.
go back to reference Chen C-W, Chen M-J, Yeh Y-S, Tsai H-L, Chang Y-T, Wang J-Y (2012) Intraoperative anastomotic dye test significantly decreases incidence of anastomotic leaks in patients undergoing resection for rectal cancer. Tech Coloproctol 17(5):579–583. doi:10.1007/s10151-012-0910-x PubMedCrossRef Chen C-W, Chen M-J, Yeh Y-S, Tsai H-L, Chang Y-T, Wang J-Y (2012) Intraoperative anastomotic dye test significantly decreases incidence of anastomotic leaks in patients undergoing resection for rectal cancer. Tech Coloproctol 17(5):579–583. doi:10.​1007/​s10151-012-0910-x PubMedCrossRef
25.
go back to reference Beard JD, Nicholson ML, Sayers RD, Lloyd D, Everson NW (1990) Intraoperative air testing of colorectal anastomoses: a prospective, randomized trial. Br J Surg 77:1095–1097PubMedCrossRef Beard JD, Nicholson ML, Sayers RD, Lloyd D, Everson NW (1990) Intraoperative air testing of colorectal anastomoses: a prospective, randomized trial. Br J Surg 77:1095–1097PubMedCrossRef
28.
go back to reference Li VKM, Wexner SD, Pulido N, Wang H, Jin HY, Weiss EG, Nogeuras JJ, Sands DR (2009) Use of routine intraoperative endoscopy in elective laparoscopic colorectal surgery: can it further avoid anastomotic failure? Surg Endosc 23:2459–2465. doi:10.1007/s00464-009-0416-4 PubMedCrossRef Li VKM, Wexner SD, Pulido N, Wang H, Jin HY, Weiss EG, Nogeuras JJ, Sands DR (2009) Use of routine intraoperative endoscopy in elective laparoscopic colorectal surgery: can it further avoid anastomotic failure? Surg Endosc 23:2459–2465. doi:10.​1007/​s00464-009-0416-4 PubMedCrossRef
29.
go back to reference Brugiotti Carlo, Valerio Corazza AP (2012) The efficacy of intraoperative endoscopic control of the colorectal stapled anastomosis after anterior resection of the rectum for rectal cancer. Colorectal Dis 14:1–76 Brugiotti Carlo, Valerio Corazza AP (2012) The efficacy of intraoperative endoscopic control of the colorectal stapled anastomosis after anterior resection of the rectum for rectal cancer. Colorectal Dis 14:1–76
30.
go back to reference Velchuru V, Bibi S, Kamal T, Zawadzki M, Threepuraneni G, Park J, Marecik S, Abcarian H, Prasad L (2013) Redoing of anastomosis following positive intra-operative leak test identified by flexible sigmoidoscopy following colo-rectal anastomosis. Dis Colon Rectum 56:e2–e249. doi:10.1097/DCR.0b013e31828d97c9 Velchuru V, Bibi S, Kamal T, Zawadzki M, Threepuraneni G, Park J, Marecik S, Abcarian H, Prasad L (2013) Redoing of anastomosis following positive intra-operative leak test identified by flexible sigmoidoscopy following colo-rectal anastomosis. Dis Colon Rectum 56:e2–e249. doi:10.​1097/​DCR.​0b013e31828d97c9​
31.
go back to reference Ghole S, Nguyen A, Jafari M, Mills S, Carmichael J, Stamos M, Pigazzi A (2013) Going beyond the air leak test-our initial experience with a new grading system utilizing flexible endoscopy for the intraoperative evaluation of rectal anastomoses. Dis Colon Rectum 56:e249. doi:10.1097/DCR.0b013e31828d97c9 Ghole S, Nguyen A, Jafari M, Mills S, Carmichael J, Stamos M, Pigazzi A (2013) Going beyond the air leak test-our initial experience with a new grading system utilizing flexible endoscopy for the intraoperative evaluation of rectal anastomoses. Dis Colon Rectum 56:e249. doi:10.​1097/​DCR.​0b013e31828d97c9​
32.
go back to reference Sakanoue Y, Nakao K, Shoji Y, Yanagi H, Kusunoki M, Utsunomiya J (1993) Intraoperative colonoscopy. Surg Endosc 7:84–87PubMedCrossRef Sakanoue Y, Nakao K, Shoji Y, Yanagi H, Kusunoki M, Utsunomiya J (1993) Intraoperative colonoscopy. Surg Endosc 7:84–87PubMedCrossRef
34.
go back to reference Lanthaler M, Biebl M, Mittermair R, Ofner D, Nehoda H (2008) Intraoperative colonoscopy for anastomosis assessment in laparoscopically assisted left-sided colon resection: is it worthwhile? J Laparoendosc Adv Surg Tech Part A 18:27–31. doi:10.1089/lap.2007.0058 CrossRef Lanthaler M, Biebl M, Mittermair R, Ofner D, Nehoda H (2008) Intraoperative colonoscopy for anastomosis assessment in laparoscopically assisted left-sided colon resection: is it worthwhile? J Laparoendosc Adv Surg Tech Part A 18:27–31. doi:10.​1089/​lap.​2007.​0058 CrossRef
35.
go back to reference Lieto E, Orditura M, Castellano P, Pinto M, Zamboli A, De Vita F, Pignatelli C, Galizia G (2011) Endoscopic intraoperative anastomotic testing may avoid early gastrointestinal anastomotic complications: a prospective study. J Gastroint Surg 15:145–152. doi:10.1007/s11605-010-1371-z CrossRef Lieto E, Orditura M, Castellano P, Pinto M, Zamboli A, De Vita F, Pignatelli C, Galizia G (2011) Endoscopic intraoperative anastomotic testing may avoid early gastrointestinal anastomotic complications: a prospective study. J Gastroint Surg 15:145–152. doi:10.​1007/​s11605-010-1371-z CrossRef
37.
go back to reference Ambrosetti P, Robert J, Mathey P, Rohner A (1994) Left-sided colon and colorectal anastomoses: doppler ultrasound as an aid to assess bowel vascularization. A prospective evaluation of 200 consecutive elective cases. Int J Colorectal Dis 9:211–214PubMedCrossRef Ambrosetti P, Robert J, Mathey P, Rohner A (1994) Left-sided colon and colorectal anastomoses: doppler ultrasound as an aid to assess bowel vascularization. A prospective evaluation of 200 consecutive elective cases. Int J Colorectal Dis 9:211–214PubMedCrossRef
38.
go back to reference Hallböök O, Johansson K, Sjödahl R (1996) Laser Doppler blood flow measurement in rectal resection for carcinoma–comparison between the straight and colonic J pouch reconstruction. Br J Surg 83:389–392PubMedCrossRef Hallböök O, Johansson K, Sjödahl R (1996) Laser Doppler blood flow measurement in rectal resection for carcinoma–comparison between the straight and colonic J pouch reconstruction. Br J Surg 83:389–392PubMedCrossRef
39.
go back to reference Vignali A, Gianotti L, Braga M, Radaelli G, Malvezzi L, Di Carlo V (2000) Altered microperfusion at the rectal stump is predictive for rectal anastomotic leak. Dis Colon Rectum 43:76–82PubMedCrossRef Vignali A, Gianotti L, Braga M, Radaelli G, Malvezzi L, Di Carlo V (2000) Altered microperfusion at the rectal stump is predictive for rectal anastomotic leak. Dis Colon Rectum 43:76–82PubMedCrossRef
40.
go back to reference Seike K, Koda K, Saito N, Oda K, Kosugi C, Shimizu K, Miyazaki M (2007) Laser Doppler assessment of the influence of division at the root of the inferior mesenteric artery on anastomotic blood flow in rectosigmoid cancer surgery. Int J Colorectal Dis 22:689–697. doi:10.1007/s00384-006-0221-7 PubMedCrossRef Seike K, Koda K, Saito N, Oda K, Kosugi C, Shimizu K, Miyazaki M (2007) Laser Doppler assessment of the influence of division at the root of the inferior mesenteric artery on anastomotic blood flow in rectosigmoid cancer surgery. Int J Colorectal Dis 22:689–697. doi:10.​1007/​s00384-006-0221-7 PubMedCrossRef
41.
go back to reference Boyle NH, Manifold D, Jordan MH, Mason RC (2000) Intraoperative assessment of colonic perfusion using scanning laser Doppler flowmetry during colonic resection. J Am Coll Surg 191:504–510PubMedCrossRef Boyle NH, Manifold D, Jordan MH, Mason RC (2000) Intraoperative assessment of colonic perfusion using scanning laser Doppler flowmetry during colonic resection. J Am Coll Surg 191:504–510PubMedCrossRef
42.
go back to reference Sheridan WG, Lowndes RH, Young HL (1987) Tissue oxygen tension as a predictor of colonic anastomotic healing. Dis Colon Rectum 30:867–871PubMedCrossRef Sheridan WG, Lowndes RH, Young HL (1987) Tissue oxygen tension as a predictor of colonic anastomotic healing. Dis Colon Rectum 30:867–871PubMedCrossRef
43.
go back to reference Hall NR, Finan PJ, Stephenson BM, Lowndes RH, Young HL (1995) High tie of the inferior mesenteric artery in distal colorectal resections–a safe vascular procedure. Int J Colorectal Dis 10:29–32PubMedCrossRef Hall NR, Finan PJ, Stephenson BM, Lowndes RH, Young HL (1995) High tie of the inferior mesenteric artery in distal colorectal resections–a safe vascular procedure. Int J Colorectal Dis 10:29–32PubMedCrossRef
44.
45.
go back to reference Hirano Y, Omura K, Tatsuzawa Y, Shimizu J, Kawaura Y, Watanabe G (2006) Tissue oxygen saturation during colorectal surgery measured by near-infrared spectroscopy: pilot study to predict anastomotic complications. World J Surg 30:457–461. doi:10.1007/s00268-005-0271-y PubMedCrossRef Hirano Y, Omura K, Tatsuzawa Y, Shimizu J, Kawaura Y, Watanabe G (2006) Tissue oxygen saturation during colorectal surgery measured by near-infrared spectroscopy: pilot study to predict anastomotic complications. World J Surg 30:457–461. doi:10.​1007/​s00268-005-0271-y PubMedCrossRef
46.
go back to reference Parmeggiani F, De Angelis N, Carra MC, Bizzarri B, Fornaroli F, Gnocchi A, Madia C, Nervi G, Valle RD, DeAngelis GL (2012) Intraoperative colonoscopy control for colorectal-anastomotic leakage: a new solution for an old problem a pilot study. Gastrointest Endosc 75:AB178. doi:10.1016/j.gie.2012.04.162 CrossRef Parmeggiani F, De Angelis N, Carra MC, Bizzarri B, Fornaroli F, Gnocchi A, Madia C, Nervi G, Valle RD, DeAngelis GL (2012) Intraoperative colonoscopy control for colorectal-anastomotic leakage: a new solution for an old problem a pilot study. Gastrointest Endosc 75:AB178. doi:10.​1016/​j.​gie.​2012.​04.​162 CrossRef
47.
go back to reference Kudszus S, Roesel C, Schachtrupp A, Höer JJ (2010) Intraoperative laser fluorescence angiography in colorectal surgery: a noninvasive analysis to reduce the rate of anastomotic leakage. Langenbecks Archiv Surg 395:1025–1030. doi:10.1007/s00423-010-0699-x CrossRef Kudszus S, Roesel C, Schachtrupp A, Höer JJ (2010) Intraoperative laser fluorescence angiography in colorectal surgery: a noninvasive analysis to reduce the rate of anastomotic leakage. Langenbecks Archiv Surg 395:1025–1030. doi:10.​1007/​s00423-010-0699-x CrossRef
48.
go back to reference Jafari MD, Lee KH, Halabi WJ, Mills SD, Carmichael JC, Stamos MJ, Pigazzi A (2013) The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surg Endosc 27(8):3003–3008. doi:10.1007/s00464-013-2832-8 PubMedCrossRef Jafari MD, Lee KH, Halabi WJ, Mills SD, Carmichael JC, Stamos MJ, Pigazzi A (2013) The use of indocyanine green fluorescence to assess anastomotic perfusion during robotic assisted laparoscopic rectal surgery. Surg Endosc 27(8):3003–3008. doi:10.​1007/​s00464-013-2832-8 PubMedCrossRef
51.
go back to reference Smith LE (1981) Anastomosis with EEA stapler after anterior colonic resection. Dis Colon Rectum 24:236–242PubMedCrossRef Smith LE (1981) Anastomosis with EEA stapler after anterior colonic resection. Dis Colon Rectum 24:236–242PubMedCrossRef
52.
go back to reference Björck M, Hedberg B (1994) Early detection of major complications after abdominal aortic surgery: predictive value of sigmoid colon and gastric intramucosal pH monitoring. Br J Surg 81:25–30PubMedCrossRef Björck M, Hedberg B (1994) Early detection of major complications after abdominal aortic surgery: predictive value of sigmoid colon and gastric intramucosal pH monitoring. Br J Surg 81:25–30PubMedCrossRef
53.
go back to reference Vahl AC, Ozkaynak-Yilmaz EN, Nauta SH, Scheffer GJ, Felt-Bersma RJ, Brom HL, Rauwerda JA (1997) Endoluminal pulse oximetry combined with tonometry to monitor the perfusion of the sigmoid during and after resection of abdominal aortic aneurysm. Cardiovasc Surg 5:65–70PubMedCrossRef Vahl AC, Ozkaynak-Yilmaz EN, Nauta SH, Scheffer GJ, Felt-Bersma RJ, Brom HL, Rauwerda JA (1997) Endoluminal pulse oximetry combined with tonometry to monitor the perfusion of the sigmoid during and after resection of abdominal aortic aneurysm. Cardiovasc Surg 5:65–70PubMedCrossRef
56.
go back to reference Dworkin MJ, Allen-Mersh TG (1996) Effect of inferior mesenteric artery ligation on blood flow in the marginal artery-dependent sigmoid colon. J Am Coll Surg 183:357–360PubMed Dworkin MJ, Allen-Mersh TG (1996) Effect of inferior mesenteric artery ligation on blood flow in the marginal artery-dependent sigmoid colon. J Am Coll Surg 183:357–360PubMed
57.
go back to reference Novell JR, Lewis AA (1990) Peroperative observation of marginal artery bleeding: a predictor of anastomotic leakage. Br J Surg 77:137–138PubMedCrossRef Novell JR, Lewis AA (1990) Peroperative observation of marginal artery bleeding: a predictor of anastomotic leakage. Br J Surg 77:137–138PubMedCrossRef
58.
go back to reference Senagore A, Milsom JW, Walshaw RK, Dunstan R, Mazier WP, Chaudry IH (1990) Intramural pH: a quantitative measurement for predicting colorectal anastomotic healing. Dis Colon Rectum 33:175–179PubMedCrossRef Senagore A, Milsom JW, Walshaw RK, Dunstan R, Mazier WP, Chaudry IH (1990) Intramural pH: a quantitative measurement for predicting colorectal anastomotic healing. Dis Colon Rectum 33:175–179PubMedCrossRef
59.
go back to reference Donati A, Cornacchini O, Loggi S, Caporelli S, Conti G, Falcetta S, Alò F, Pagliariccio G, Bruni E, Preiser J-C, Pelaia P (2004) A comparison among portal lactate, intramucosal sigmoid Ph, and delta CO2 (PaCO2 - regional Pco2) as indices of complications in patients undergoing abdominal aortic aneurysm surgery. Anesth Analg 99:1024–1031. doi:10.1213/01.ANE.0000132543.65095.2C PubMedCrossRef Donati A, Cornacchini O, Loggi S, Caporelli S, Conti G, Falcetta S, Alò F, Pagliariccio G, Bruni E, Preiser J-C, Pelaia P (2004) A comparison among portal lactate, intramucosal sigmoid Ph, and delta CO2 (PaCO2 - regional Pco2) as indices of complications in patients undergoing abdominal aortic aneurysm surgery. Anesth Analg 99:1024–1031. doi:10.​1213/​01.​ANE.​0000132543.​65095.​2C PubMedCrossRef
60.
go back to reference Kvietys PR, Shepherd AP, Granger DN (1985) Laser-Doppler, H2 clearance, and microsphere estimates of mucosal blood flow. Am J Physiol 249:G221–G227PubMed Kvietys PR, Shepherd AP, Granger DN (1985) Laser-Doppler, H2 clearance, and microsphere estimates of mucosal blood flow. Am J Physiol 249:G221–G227PubMed
62.
go back to reference Wells GA Shea B, O’connell D, Peterson J, Welch V, Losos M (2000) The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. In: 3rd Symposium on Systematic Reviews: Beyond the Basics, pp 3–5 Wells GA Shea B, O’connell D, Peterson J, Welch V, Losos M (2000) The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. In: 3rd Symposium on Systematic Reviews: Beyond the Basics, pp 3–5
63.
go back to reference Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJMH (1996) Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17:1–12PubMedCrossRef Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJMH (1996) Assessing the quality of reports of randomized clinical trials: is blinding necessary? Control Clin Trials 17:1–12PubMedCrossRef
Metadata
Title
Intraoperative assessment of colorectal anastomotic integrity: a systematic review
Authors
Subramanian Nachiappan
Alan Askari
Andrew Currie
Robin H. Kennedy
Omar Faiz
Publication date
01-09-2014
Publisher
Springer US
Published in
Surgical Endoscopy / Issue 9/2014
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-014-3520-z

Other articles of this Issue 9/2014

Surgical Endoscopy 9/2014 Go to the issue