Skip to main content
Top
Published in: Surgical Endoscopy 1/2011

01-01-2011

Damage to the spermatic cord by the Lichtenstein and TAPP procedures in a pig model

Authors: Karsten Junge, Marcel Binnebösel, Caroline Kauffmann, Raphael Rosch, Christian Klink, Klaus von Trotha, Felix Schoth, Volker Schumpelick, Uwe Klinge

Published in: Surgical Endoscopy | Issue 1/2011

Login to get access

Abstract

Background

Mesh implantation is regarded as the standard treatment of inguinal hernias. Obstructive azoospermia induced by mesh implantation is a rare but serious complication. Whether different operative techniques or mesh materials used have an effect on the integrity of the testicle and spermatic cord remains unclear.

Materials

In 12 minipigs a bilateral inguinal hernia repair, either open or laparoscopic, was performed using a standard small-pore polypropylene (PP) or large-pore polyvinyliden fluoride (PVDF) mesh. Next to measurement of the testicular size, thermography of the groin and testicle as a parameter for perfusion was performed preoperatively and at a follow-up at 6 months. Obstructions of the vas deferens were estimated radiographically. Testicular function (Johnson score) and mesh integration (granuloma size, apoptotic cells) were analyzed histologically.

Results

Mean testicular size did not change significantly in follow-up compared to preoperative values. Technique and mesh material used failed to have a significant influence. Thermography of the groin following the Lichtenstein technique had significantly higher values at follow-up regardless of the mesh used. This could not been shown for laparoscopic treatment. Thermographic measurements at the testicle showed a significantly increased temperature in all groups compared to preoperative measurements. Only the Lichtenstein PP group showed significantly decreased values in testicular function. Quantity and quality of obstructions seen at vasography were most detectable in the Lichtenstein PP group. There was significantly decreased granuloma formation following PVDF mesh implantation compared to the PP mesh group regardless of the technique used.

Conclusions

Both the technique and the mesh material have an impact on integrity of spermatic cord and testicular function. According to the results of this study, the laparoscopic TAPP procedure using a large-pore PVDF mesh has the least effect compared to preoperative values.
Literature
1.
go back to reference Simons MP, Aufenacker T, Bay-Nielsen M, Bouillot JL, Campanelli G, Conze J, de Lange D, Fortelny R, Heikkinen T, Kingsnorth A, Kukleta J, Morales-Conde S, Nordin P, Schumpelick V, Smedberg S, Smietanski M, Weber G, Miserez M (2009) European Hernia Society guidelines on the treatment of inguinal hernia in adult patients. Hernia 13(4):343–403CrossRefPubMed Simons MP, Aufenacker T, Bay-Nielsen M, Bouillot JL, Campanelli G, Conze J, de Lange D, Fortelny R, Heikkinen T, Kingsnorth A, Kukleta J, Morales-Conde S, Nordin P, Schumpelick V, Smedberg S, Smietanski M, Weber G, Miserez M (2009) European Hernia Society guidelines on the treatment of inguinal hernia in adult patients. Hernia 13(4):343–403CrossRefPubMed
2.
go back to reference Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair. Biomaterials 19(24):2235–2246CrossRefPubMed Klosterhalfen B, Klinge U, Schumpelick V (1998) Functional and morphological evaluation of different polypropylene-mesh modifications for abdominal wall repair. Biomaterials 19(24):2235–2246CrossRefPubMed
3.
go back to reference Junge K, Klinge U, Rosch R, Klosterhalfen B, Schumpelick V (2002) Functional and morphologic properties of a modified mesh for inguinal hernia repair. World J Surg 26(12):1472–1480CrossRefPubMed Junge K, Klinge U, Rosch R, Klosterhalfen B, Schumpelick V (2002) Functional and morphologic properties of a modified mesh for inguinal hernia repair. World J Surg 26(12):1472–1480CrossRefPubMed
4.
go back to reference Klinge U, Klosterhalfen B, Ottinger AP, Junge K, Schumpelick V (2002) PVDF as a new polymer for the construction of surgical meshes. Biomaterials 23(16):3487–3493CrossRefPubMed Klinge U, Klosterhalfen B, Ottinger AP, Junge K, Schumpelick V (2002) PVDF as a new polymer for the construction of surgical meshes. Biomaterials 23(16):3487–3493CrossRefPubMed
5.
go back to reference Junge K, Klinge U, Prescher A, Giboni P, Niewiera M, Schumpelick V (2001) Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 5(3):113–118CrossRefPubMed Junge K, Klinge U, Prescher A, Giboni P, Niewiera M, Schumpelick V (2001) Elasticity of the anterior abdominal wall and impact for reparation of incisional hernias using mesh implants. Hernia 5(3):113–118CrossRefPubMed
6.
go back to reference Klinge U, Klosterhalfen B, Conze J, Limberg W, Obolenski B, Ottinger AP, Schumpelick V (1998) Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall. Eur J Surg 164(12):951–960CrossRefPubMed Klinge U, Klosterhalfen B, Conze J, Limberg W, Obolenski B, Ottinger AP, Schumpelick V (1998) Modified mesh for hernia repair that is adapted to the physiology of the abdominal wall. Eur J Surg 164(12):951–960CrossRefPubMed
7.
go back to reference Urban E, King MW, Guidoin R, Laroche G, Marois Y, Martin L, Cardou A, Douville Y (1994) Why make monofilament sutures out of polyvinylidene fluoride? ASAIO J 40(2):145–156PubMed Urban E, King MW, Guidoin R, Laroche G, Marois Y, Martin L, Cardou A, Douville Y (1994) Why make monofilament sutures out of polyvinylidene fluoride? ASAIO J 40(2):145–156PubMed
8.
go back to reference Bringman S, Wollert S, Osterberg J, Smedberg S, Granlund H, Heikkinen TJ (2006) Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia. Br J Surg 93(9):1056–1059CrossRefPubMed Bringman S, Wollert S, Osterberg J, Smedberg S, Granlund H, Heikkinen TJ (2006) Three-year results of a randomized clinical trial of lightweight or standard polypropylene mesh in Lichtenstein repair of primary inguinal hernia. Br J Surg 93(9):1056–1059CrossRefPubMed
9.
go back to reference O’Dwyer PJ, Kingsnorth AN, Molloy RG, Small PK, Lammers B, Horeyseck G (2005) Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92(2):166–170CrossRefPubMed O’Dwyer PJ, Kingsnorth AN, Molloy RG, Small PK, Lammers B, Horeyseck G (2005) Randomized clinical trial assessing impact of a lightweight or heavyweight mesh on chronic pain after inguinal hernia repair. Br J Surg 92(2):166–170CrossRefPubMed
10.
go back to reference Horstmann R, Hellwig M, Classen C, Rottgermann S, Palmes D (2006) Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes. World J Surg 30(9):1742–1749CrossRefPubMed Horstmann R, Hellwig M, Classen C, Rottgermann S, Palmes D (2006) Impact of polypropylene amount on functional outcome and quality of life after inguinal hernia repair by the TAPP procedure using pure, mixed, and titanium-coated meshes. World J Surg 30(9):1742–1749CrossRefPubMed
11.
go back to reference Nienhuijs S, Staal E, Strobbe L, Rosman C, Groenewoud H, Bleichrodt R (2007) Chronic pain after mesh repair of inguinal hernia: a systematic review. Am J Surg 194(3):394–400CrossRefPubMed Nienhuijs S, Staal E, Strobbe L, Rosman C, Groenewoud H, Bleichrodt R (2007) Chronic pain after mesh repair of inguinal hernia: a systematic review. Am J Surg 194(3):394–400CrossRefPubMed
12.
go back to reference de Weerd L, Mercer JB, Setsa LB (2006) Intraoperative dynamic infrared thermography and free-flap surgery. Ann Plast Surg 57(3):279–284CrossRefPubMed de Weerd L, Mercer JB, Setsa LB (2006) Intraoperative dynamic infrared thermography and free-flap surgery. Ann Plast Surg 57(3):279–284CrossRefPubMed
13.
go back to reference Johnson SG (1970) Testicular biopsy score count—a method for registration of spermatogenesis in human testes: normal values and results in 335 hypogonadal males. Hormones 1:2–25CrossRef Johnson SG (1970) Testicular biopsy score count—a method for registration of spermatogenesis in human testes: normal values and results in 335 hypogonadal males. Hormones 1:2–25CrossRef
14.
go back to reference Pollak R, Nyhus LM (1983) Complications of groin hernia repair. Surg Clin North Am 63(6):1363–1371PubMed Pollak R, Nyhus LM (1983) Complications of groin hernia repair. Surg Clin North Am 63(6):1363–1371PubMed
15.
go back to reference Yamaguchi K, Ishikawa T, Nakano Y, Kondo Y, Shiotani M, Fujisawa M (2008) Rapidly progressing, late-onset obstructive azoospermia linked to herniorrhaphy with mesh. Fertil Steril 90(5):2018.e5–2018.e7CrossRef Yamaguchi K, Ishikawa T, Nakano Y, Kondo Y, Shiotani M, Fujisawa M (2008) Rapidly progressing, late-onset obstructive azoospermia linked to herniorrhaphy with mesh. Fertil Steril 90(5):2018.e5–2018.e7CrossRef
16.
go back to reference Shin D, Lipshultz LI, Goldstein M, Barme GA, Fuchs EF, Nagler HM, McCallum SW, Niederberger CS, Schoor RA, Brugh VM 3rd, Honig SC (2005) Herniorrhaphy with polypropylene mesh causing inguinal vasal obstruction: a preventable cause of obstructive azoospermia. Ann Surg 241(4):553–558CrossRefPubMed Shin D, Lipshultz LI, Goldstein M, Barme GA, Fuchs EF, Nagler HM, McCallum SW, Niederberger CS, Schoor RA, Brugh VM 3rd, Honig SC (2005) Herniorrhaphy with polypropylene mesh causing inguinal vasal obstruction: a preventable cause of obstructive azoospermia. Ann Surg 241(4):553–558CrossRefPubMed
17.
go back to reference Uzzo RG, Lemack GE, Morrissey KP, Goldstein M (1999) The effects of mesh bioprosthesis on the spermatic cord structures: a preliminary report in a canine model. J Urol 161(4):1344–1349CrossRefPubMed Uzzo RG, Lemack GE, Morrissey KP, Goldstein M (1999) The effects of mesh bioprosthesis on the spermatic cord structures: a preliminary report in a canine model. J Urol 161(4):1344–1349CrossRefPubMed
18.
go back to reference Goldenberg A, Matone J, Marcondes W, Herbella FA, Farah JF (2005) Comparative study of inflammatory response and adhesions formation after fixation of different meshes for inguinal hernia repair in rabbits. Acta Cir Bras 20(5):347–352CrossRefPubMed Goldenberg A, Matone J, Marcondes W, Herbella FA, Farah JF (2005) Comparative study of inflammatory response and adhesions formation after fixation of different meshes for inguinal hernia repair in rabbits. Acta Cir Bras 20(5):347–352CrossRefPubMed
19.
go back to reference Akbulut G, Serteser M, Yucel A, Degirmenci B, Yilmaz S, Polat C, San O, Dilek ON (2003) Can laparoscopic hernia repair alter function and volume of testis? Randomized clinical trial. Surg Laparosc Endosc Percutan Tech 13(6):377–381CrossRefPubMed Akbulut G, Serteser M, Yucel A, Degirmenci B, Yilmaz S, Polat C, San O, Dilek ON (2003) Can laparoscopic hernia repair alter function and volume of testis? Randomized clinical trial. Surg Laparosc Endosc Percutan Tech 13(6):377–381CrossRefPubMed
20.
go back to reference Ersin S, Aydin U, Makay O, Icoz G, Tamsel S, Sozbilen M, Killi R (2006) Is testicular perfusion influenced during laparoscopic inguinal hernia surgery? Surg Endosc 20(4):685–689CrossRefPubMed Ersin S, Aydin U, Makay O, Icoz G, Tamsel S, Sozbilen M, Killi R (2006) Is testicular perfusion influenced during laparoscopic inguinal hernia surgery? Surg Endosc 20(4):685–689CrossRefPubMed
21.
go back to reference Peiper C, Junge K, Klinge U, Strehlau E, Krones C, Ottinger A, Schumpelick V (2005) The influence of inguinal mesh repair on the spermatic cord: a pilot study in the rabbit. J Invest Surg 18(5):273–278CrossRefPubMed Peiper C, Junge K, Klinge U, Strehlau E, Krones C, Ottinger A, Schumpelick V (2005) The influence of inguinal mesh repair on the spermatic cord: a pilot study in the rabbit. J Invest Surg 18(5):273–278CrossRefPubMed
22.
go back to reference Junge K, Binnebosel M, Rosch R, Ottinger A, Stumpf M, Muhlenbruch G, Schumpelick V, Klinge U (2008) Influence of mesh materials on the integrity of the vas deferens following Lichtenstein hernioplasty: an experimental model. Hernia 12(6):621–626CrossRefPubMed Junge K, Binnebosel M, Rosch R, Ottinger A, Stumpf M, Muhlenbruch G, Schumpelick V, Klinge U (2008) Influence of mesh materials on the integrity of the vas deferens following Lichtenstein hernioplasty: an experimental model. Hernia 12(6):621–626CrossRefPubMed
23.
go back to reference Berndsen FH, Bjursten LM, Simanaitis M, Montgomery A (2004) Does mesh implantation affect the spermatic cord structures after inguinal hernia surgery? An experimental study in rats. Eur Surg Res 36(5):318–322CrossRefPubMed Berndsen FH, Bjursten LM, Simanaitis M, Montgomery A (2004) Does mesh implantation affect the spermatic cord structures after inguinal hernia surgery? An experimental study in rats. Eur Surg Res 36(5):318–322CrossRefPubMed
Metadata
Title
Damage to the spermatic cord by the Lichtenstein and TAPP procedures in a pig model
Authors
Karsten Junge
Marcel Binnebösel
Caroline Kauffmann
Raphael Rosch
Christian Klink
Klaus von Trotha
Felix Schoth
Volker Schumpelick
Uwe Klinge
Publication date
01-01-2011
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 1/2011
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-010-1148-1

Other articles of this Issue 1/2011

Surgical Endoscopy 1/2011 Go to the issue