Skip to main content
Top
Published in: Surgical Endoscopy 4/2004

01-04-2004 | Original article

Prevention of adhesion formation to polypropylene mesh by collagen coating: A randomized controlled study in a rat model of ventral hernia repair

Authors: M. van’t Riet, J. W. A. Burger, F. Bonthuis, J. Jeekel, H. J. Bonjer

Published in: Surgical Endoscopy | Issue 4/2004

Login to get access

Abstract

Introduction

In laparoscopic incisional hernia repair with intraperitoneal mesh, concern exists about the development of adhesions between bowel and mesh, predisposing to intestinal obstruction and enterocutaneous fistulas. The aim of this study was to assess whether the addition of a collagen coating on the visceral side of a polypropylene mesh can prevent adhesion formation to the mesh.

Method

In 58 rats, a defect in the muscular abdominal wall was created, and a mesh was fixed intraperitoneally to cover the defect. Rats were divided in two groups; polypropylene mesh (control group) and polypropylene mesh with collagen coating (Parieten mesh). Seven and 30 days postoperatively, adhesions and amount and strength of mesh incorporation were assessed. Wound healing was studied by microscopy.

Results

With Parieten mesh, the mesh surface covered by adhesions was reduced after 30 days (42% vs 69%, p = 0.01), but infection rate was increased after both 7 (p = 0.001) and 30 days (p = 0.03), compared to the polypropylene group with no mesh infections. If animals with mesh infection were excluded in the analysis, the mesh surface covered by adhesions was reduced after 7 days (21% vs 76%, p = 0.02), as well as after 30 days (21 vs 69%, p < 0.001). Percentage of mesh incorporation was comparable in both groups. Mean tensile strength of mesh incorporation after 30 days was higher with Parieten mesh.

Conclusion

Although the coated Parieten mesh was more susceptible to mesh infection in the current model, a significant reduction of adhesion formation was still seen with the Parieten mesh after 30 days, with comparable mesh incorporation in the abdominal wall.
Literature
1.
go back to reference Alponat, A, Lakshminarasappa, SR, Yavuz, N, Goh, PM 1997Prevention of adhesions by Seprafilm, an absorbable adhesion barrier: an incisional hernia model in rats.Am Surg63818819PubMed Alponat, A, Lakshminarasappa, SR, Yavuz, N, Goh, PM 1997Prevention of adhesions by Seprafilm, an absorbable adhesion barrier: an incisional hernia model in rats.Am Surg63818819PubMed
2.
go back to reference Carbajo, MA, Marin Olmo, JC, Blanco, JI, Cuesta, C, Toledano, M, Martin, F, Vaquero, C 1999Laparoscopic treatment versus open surgery in the solution of major incisional and abdominal wall hernias with mesh.Surg Endosc13250252PubMed Carbajo, MA, Marin Olmo, JC, Blanco, JI, Cuesta, C, Toledano, M, Martin, F, Vaquero, C 1999Laparoscopic treatment versus open surgery in the solution of major incisional and abdominal wall hernias with mesh.Surg Endosc13250252PubMed
3.
go back to reference Maria, EJ, Moss, JM, Sugerman, HJ 2000Laparoscopic intraperitoneal polytetrafluoroethylene (PTFE) prosthetic patch repair of ventral hernia.Surg Endosc14326329PubMed Maria, EJ, Moss, JM, Sugerman, HJ 2000Laparoscopic intraperitoneal polytetrafluoroethylene (PTFE) prosthetic patch repair of ventral hernia.Surg Endosc14326329PubMed
4.
go back to reference Dinsmore, RC, Calton WC, Jr, Harvey, SB, Blaney, MW 2000Prevention of adhesions to polypropylene mesh in a traumatized bowel model.J Am Coll Surg191131136CrossRefPubMed Dinsmore, RC, Calton WC, Jr, Harvey, SB, Blaney, MW 2000Prevention of adhesions to polypropylene mesh in a traumatized bowel model.J Am Coll Surg191131136CrossRefPubMed
5.
go back to reference Ellis, H, Moran, BJ, Thompson, JN, Parker, MC, Wilson, MS, Menzies, D, et al. 1999Adhesion-related hospital readmissions after abdominal and pelvic surgery: a retrospective cohort study.Lancet35314761480PubMed Ellis, H, Moran, BJ, Thompson, JN, Parker, MC, Wilson, MS, Menzies, D,  et al. 1999Adhesion-related hospital readmissions after abdominal and pelvic surgery: a retrospective cohort study.Lancet35314761480PubMed
6.
go back to reference Franklin, ME, Dorman, JP, Glass, JL, Balli, JE, Gonzalez, JJ 1998Laparoscopic ventral and incisional hernia repair.Surg Laparosc Endosc4294299CrossRef Franklin, ME, Dorman, JP, Glass, JL, Balli, JE, Gonzalez, JJ 1998Laparoscopic ventral and incisional hernia repair.Surg Laparosc Endosc4294299CrossRef
7.
go back to reference Hesselink, VJ, Luijendijk, RW, Wilt, JHW, Heide, R, Jeekel, J 1993Incisional hernia recurrence; an evaluation of risk factors.Surg Gynaecol Obstet176228234 Hesselink, VJ, Luijendijk, RW, Wilt, JHW, Heide, R, Jeekel, J 1993Incisional hernia recurrence; an evaluation of risk factors.Surg Gynaecol Obstet176228234
8.
go back to reference Holzman, MD, Purut, CM, Reintgen, K, Eubanks, S, Pappas, TN 1997Laparoscopic ventral and incisional herniaplasty.Surg Endosc113235PubMed Holzman, MD, Purut, CM, Reintgen, K, Eubanks, S, Pappas, TN 1997Laparoscopic ventral and incisional herniaplasty.Surg Endosc113235PubMed
9.
go back to reference Hooker, GD, Taylor, BM, Driman, DK 1999Prevention of adhesion formation with use of sodium hyaluronate-based bioresorbable membrane in a rat model of ventral hernia repair with polypropylene mesh—a randomized controlled study.Surgery125211216CrossRefPubMed Hooker, GD, Taylor, BM, Driman, DK 1999Prevention of adhesion formation with use of sodium hyaluronate-based bioresorbable membrane in a rat model of ventral hernia repair with polypropylene mesh—a randomized controlled study.Surgery125211216CrossRefPubMed
10.
go back to reference Jenkins, SD, Klamer, TW, Parteka, JJ, Condon, RE 1983A comparison of prosthetic materials used to repair abdominal wall defects.Surgery94392398PubMed Jenkins, SD, Klamer, TW, Parteka, JJ, Condon, RE 1983A comparison of prosthetic materials used to repair abdominal wall defects.Surgery94392398PubMed
11.
go back to reference Kaufman, Z, Engelberg, M, Zager, M 1981Fecal fistula: a late complication of marlex mesh repair.Dis Col Rectum245354 Kaufman, Z, Engelberg, M, Zager, M 1981Fecal fistula: a late complication of marlex mesh repair.Dis Col Rectum245354
12.
go back to reference Klosterhafen, B, Junge, K, Hermanns, B, Klinge, U 2002Influence of implantation interval on the long-termbiocompatibility of surgical mesh.Br J Surg8910431048CrossRefPubMed Klosterhafen, B, Junge, K, Hermanns, B, Klinge, U 2002Influence of implantation interval on the long-termbiocompatibility of surgical mesh.Br J Surg8910431048CrossRefPubMed
13.
go back to reference Law, NH, Ellis, H 1988Adhesion formation and peritoneal healing on prosthetic materials.Clin Mater395101 Law, NH, Ellis, H 1988Adhesion formation and peritoneal healing on prosthetic materials.Clin Mater395101
14.
go back to reference Leber, GE, Garb, JL, Alexander, AL, Reed, WP 1998Long-term complications associated with prosthetic repair of incisional hernias.Arch Surg133378382PubMed Leber, GE, Garb, JL, Alexander, AL, Reed, WP 1998Long-term complications associated with prosthetic repair of incisional hernias.Arch Surg133378382PubMed
15.
go back to reference Liakakos, T, Karanikas, I, Panagitidis, H, Dendrinos, S 1994Use of Marlex mesh in the repair of recurrent incisional hernia.Br J Surg81248249PubMed Liakakos, T, Karanikas, I, Panagitidis, H, Dendrinos, S 1994Use of Marlex mesh in the repair of recurrent incisional hernia.Br J Surg81248249PubMed
16.
go back to reference Lichtenstein, IL, Shulman, AG, Amid, PK 1991Twenty questions about hernioplasty.Am Surg57730733PubMed Lichtenstein, IL, Shulman, AG, Amid, PK 1991Twenty questions about hernioplasty.Am Surg57730733PubMed
17.
go back to reference Luijendijk, RW, Lemmen, MH, Hop, WC, Wereldsma, JC 1997Incisional hernia recurrence following “vest over pants” or vertical Mayo repair of primary hernias of the midline.World J Surg216266PubMed Luijendijk, RW, Lemmen, MH, Hop, WC, Wereldsma, JC 1997Incisional hernia recurrence following “vest over pants” or vertical Mayo repair of primary hernias of the midline.World J Surg216266PubMed
18.
go back to reference Luijendijk, RW, Hop, WC, Tol, MP, Lange, DC, Braaksma, MM, IJzermans, JN, et al. 2000A comparison of suture repair with mesh repair for incisional hernia.N Engl J Med10392398CrossRef Luijendijk, RW, Hop, WC, Tol, MP, Lange, DC, Braaksma, MM, IJzermans, JN,  et al. 2000A comparison of suture repair with mesh repair for incisional hernia.N Engl J Med10392398CrossRef
19.
go back to reference Macmillan, JI, Freeman, JB 1984Healing of a gastrocutaneous fistula in the presence of marlex.Can J Surg27159160PubMed Macmillan, JI, Freeman, JB 1984Healing of a gastrocutaneous fistula in the presence of marlex.Can J Surg27159160PubMed
20.
go back to reference Morris-stiff, GJ, Hughes, LE 1998The outcomes of nonabsorbable mesh placed within the abdominal cavity: literature review and clinical experience.J Am Coll Surg186352567PubMed Morris-stiff, GJ, Hughes, LE 1998The outcomes of nonabsorbable mesh placed within the abdominal cavity: literature review and clinical experience.J Am Coll Surg186352567PubMed
21.
go back to reference Mutter, D, Jamali, FR, Moody, DL, Rodeheaver, GT, Therm, M, Marescaux, J 2000The concept of protected mesh to minimize adhesion formation in intraperitoneal abdominal wall reinforcement.Preclinical evaluation of a new composite mesh. Hernia4S39 Mutter, D, Jamali, FR, Moody, DL, Rodeheaver, GT, Therm, M, Marescaux, J 2000The concept of protected mesh to minimize adhesion formation in intraperitoneal abdominal wall reinforcement.Preclinical evaluation of a new composite mesh. Hernia4S39
22.
go back to reference Park, A, Birch, DW, Lovrics, P 1998Laparoscopic and open incisional hernia repair: a comparison study.Surgery124816821PubMed Park, A, Birch, DW, Lovrics, P 1998Laparoscopic and open incisional hernia repair: a comparison study.Surgery124816821PubMed
23.
go back to reference Paul, A, Korenkov, M, Peters, S, Kohler, L, Fischer, S, Troidl, H 1998Unacceptable results of the Mayo procedure for repair of abdominal incisional hernias.Eur J Surg164361367CrossRefPubMed Paul, A, Korenkov, M, Peters, S, Kohler, L, Fischer, S, Troidl, H 1998Unacceptable results of the Mayo procedure for repair of abdominal incisional hernias.Eur J Surg164361367CrossRefPubMed
24.
go back to reference Ramshaw, BJ, Esartia, P, Schwab, J, Mason, EM, Wilson, RA, Duncan, TD, et al. 1999Comparison of laparoscopic and open ventral herniorrhaphy.Am Surg65827832PubMed Ramshaw, BJ, Esartia, P, Schwab, J, Mason, EM, Wilson, RA, Duncan, TD,  et al. 1999Comparison of laparoscopic and open ventral herniorrhaphy.Am Surg65827832PubMed
25.
go back to reference Rios, A, Rodriguez, JM, Munitiz, V, Alcaraz, P, Perez Flores, D, Parrilla, P 2001Antibiotic prophylaxis in incisional hernia repair using a prosthesis.Hernia5148152PubMed Rios, A, Rodriguez, JM, Munitiz, V, Alcaraz, P, Perez Flores, D, Parrilla, P 2001Antibiotic prophylaxis in incisional hernia repair using a prosthesis.Hernia5148152PubMed
26.
go back to reference Schmitt, HJ,Jr, Grinnan, GLB 1967Use of marlex mesh in infected abdominal war wound.Am J Surg113825828PubMed Schmitt, HJ,Jr, Grinnan, GLB 1967Use of marlex mesh in infected abdominal war wound.Am J Surg113825828PubMed
27.
go back to reference Turkcapar, AG, Yerdel, MA, Aydinuraz, K, Bayar, S, Kuterdem, E 1998Repair of midline incisional hernias using polypropylene grafts.Surg Today285963CrossRefPubMed Turkcapar, AG, Yerdel, MA, Aydinuraz, K, Bayar, S, Kuterdem, E 1998Repair of midline incisional hernias using polypropylene grafts.Surg Today285963CrossRefPubMed
28.
go back to reference Riet, M, Vos Steenwijk, PJ, Bonthuis, F, Marquet, RL, Steyerberg, EW, Jeekel, J, Bonjer, HJ 2003Prevention of adhesion to prosthetic mesh: comparison of different barriers, using an incisional hernia model.Ann Surg237123128PubMed Riet, M, Vos Steenwijk, PJ, Bonthuis, F, Marquet, RL, Steyerberg, EW, Jeekel, J, Bonjer, HJ 2003Prevention of adhesion to prosthetic mesh: comparison of different barriers, using an incisional hernia model.Ann Surg237123128PubMed
29.
go back to reference Walker, PM, Langer, B 1976Marlex mesh for repair of abdominal wall defects.Can J Surg19211213PubMed Walker, PM, Langer, B 1976Marlex mesh for repair of abdominal wall defects.Can J Surg19211213PubMed
30.
go back to reference Zühlke, HV, Lorenz, EMP, Straub, EM, Savvas, V 1990Pathophysiologie und Klassifikation von Adhesionen.Langenbecks Arch Chir Suppl II Verh Dtrsch Ges Chir34510091016 Zühlke, HV, Lorenz, EMP, Straub, EM, Savvas, V 1990Pathophysiologie und Klassifikation von Adhesionen.Langenbecks Arch Chir Suppl II Verh Dtrsch Ges Chir34510091016
Metadata
Title
Prevention of adhesion formation to polypropylene mesh by collagen coating: A randomized controlled study in a rat model of ventral hernia repair
Authors
M. van’t Riet
J. W. A. Burger
F. Bonthuis
J. Jeekel
H. J. Bonjer
Publication date
01-04-2004
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 4/2004
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-003-9054-4

Other articles of this Issue 4/2004

Surgical Endoscopy 4/2004 Go to the issue