Skip to main content
Top
Published in: Surgical Endoscopy 8/2006

01-08-2006

Skill performance in open videoscopic surgery

Authors: A. Mohamed, A. Rafiq, L. Panait, V. Lavrentyev, C. R. Doarn, R. C. Merrell

Published in: Surgical Endoscopy | Issue 8/2006

Login to get access

Abstract

Introduction

Application of minimally invasive surgery represents the future of modern surgical care. Previous studies by our group provided a novel way for viewing open surgery using a rigid endoscope attached to charged coupled device (CCD) camera in proximity to the surgical field using a robotic arm (AESOP) and a stabilizing fulcrum (Alpha port).

Materials and methods

This study is a follow-up to investigate the technical feasibility, advantages, and disadvantages of relying only on video images displayed on standard monitors in performing open surgical procedures instead of direct binocular eye vision. This study used two surgeons as participants with training in basic surgical skill and previous experience in performing an intestinal anastomosis in an ordinary fashion. The standard task consisted of anastomosing porcine intestine in two layers with digital viewing of the operative field. A total of 40 anastomoses (20 by each surgeon) were compared with 10 control performances using direct vision of the field.

Results

All the resulting anastomoses were accurate, well coapted, and fully patent with no leakage. Time for task performance was approximately twice as long (p < 0.05) with videoscopic vision as with direct vision.

Discussion

These findings suggest it is technically feasible to conduct open surgeries with visualization of the open surgical field limited to video display on standard monitors.
Literature
1.
go back to reference Ballantyne GH (2002) Robotic surgery, telerobotic surgery, telepresence, and telemonitoring: review of early clinical results. Surg Endosc 16: 1389–1402PubMedCrossRef Ballantyne GH (2002) Robotic surgery, telerobotic surgery, telepresence, and telemonitoring: review of early clinical results. Surg Endosc 16: 1389–1402PubMedCrossRef
2.
go back to reference Broderick TG, Russell KM, Doarn CR, Merrell RC (2000) A novel telemedicine method for viewing the open surgical field. J Laparoendosc Surg Adv Surg Techn 12: 293–298CrossRef Broderick TG, Russell KM, Doarn CR, Merrell RC (2000) A novel telemedicine method for viewing the open surgical field. J Laparoendosc Surg Adv Surg Techn 12: 293–298CrossRef
3.
go back to reference Hanna BG, Cresswell A, Cuschieri A (2002) Shadow depth cues and endoscopic task performance. Arch Surg 137: 1166–1169PubMedCrossRef Hanna BG, Cresswell A, Cuschieri A (2002) Shadow depth cues and endoscopic task performance. Arch Surg 137: 1166–1169PubMedCrossRef
4.
go back to reference Hanna BG, Cuschieri A (1999) Influence of optical axis to target view angle on endoscopic task performance. Surg Endosc 13: 371–375PubMedCrossRef Hanna BG, Cuschieri A (1999) Influence of optical axis to target view angle on endoscopic task performance. Surg Endosc 13: 371–375PubMedCrossRef
5.
go back to reference Hanna BG, Cuschieri A (2000) Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing. World J Surg 24: 444–449PubMedCrossRef Hanna BG, Cuschieri A (2000) Influence of two-dimensional and three-dimensional imaging on endoscopic bowel suturing. World J Surg 24: 444–449PubMedCrossRef
6.
go back to reference Hanna BG, Cuschieri A (2001) Image display technology and image processing. World J Surg 25: 1419–1127PubMedCrossRef Hanna BG, Cuschieri A (2001) Image display technology and image processing. World J Surg 25: 1419–1127PubMedCrossRef
7.
go back to reference Kondraske GV, Hamilton EC, Scott DJ, Fischer CA, Tesfay ST, Taneja R, Brown RJ, Jones DB (2002) Surgeon workload and motion efficiency with robot and human laparoscopic camera control. Surg Endosc 16: 1523–1527PubMedCrossRef Kondraske GV, Hamilton EC, Scott DJ, Fischer CA, Tesfay ST, Taneja R, Brown RJ, Jones DB (2002) Surgeon workload and motion efficiency with robot and human laparoscopic camera control. Surg Endosc 16: 1523–1527PubMedCrossRef
8.
go back to reference Panait L, Rafiq A, Mohamed A, Doarn C, Merrell RC (2003) Surgical skill facilitation in videoscopic open surgery. J Laparoendosc Adv Surg Techn A 13: 387–395CrossRef Panait L, Rafiq A, Mohamed A, Doarn C, Merrell RC (2003) Surgical skill facilitation in videoscopic open surgery. J Laparoendosc Adv Surg Techn A 13: 387–395CrossRef
9.
go back to reference Rosser JC, Bell RL, Harnett B, Rodas E, Murayama M, Merrell RC (1999) Use of mobile low-bandwidth telemedical technologies for extreme telemedicine applications. J Am Coll Surg 189: 397–404PubMedCrossRef Rosser JC, Bell RL, Harnett B, Rodas E, Murayama M, Merrell RC (1999) Use of mobile low-bandwidth telemedical technologies for extreme telemedicine applications. J Am Coll Surg 189: 397–404PubMedCrossRef
10.
go back to reference Russell KM, Broderick TJ, De Maria EJ, Kothari SN, Merrell RC (2001) Laparoscopic telescope with Alpha Port and AESOP to view open surgical procedures. J Laparoendosc Surg Adv Surg Techn 11: 213–217CrossRef Russell KM, Broderick TJ, De Maria EJ, Kothari SN, Merrell RC (2001) Laparoscopic telescope with Alpha Port and AESOP to view open surgical procedures. J Laparoendosc Surg Adv Surg Techn 11: 213–217CrossRef
11.
Metadata
Title
Skill performance in open videoscopic surgery
Authors
A. Mohamed
A. Rafiq
L. Panait
V. Lavrentyev
C. R. Doarn
R. C. Merrell
Publication date
01-08-2006
Publisher
Springer-Verlag
Published in
Surgical Endoscopy / Issue 8/2006
Print ISSN: 0930-2794
Electronic ISSN: 1432-2218
DOI
https://doi.org/10.1007/s00464-005-0696-2

Other articles of this Issue 8/2006

Surgical Endoscopy 8/2006 Go to the issue

OriginalPaper

Endo-Lap OR