Skip to main content
Top
Published in: Dysphagia 6/2021

Open Access 01-12-2021 | Computed Tomography | Original Article

Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography

Authors: Yoko Inamoto, Eiichi Saitoh, Jeffrey B. Palmer

Published in: Dysphagia | Issue 6/2021

Login to get access

Abstract

Understanding bolus flow patterns in swallowing (rheology, the study of flow) is fundamental to assessment and treatment of dysphagia. These patterns are complex and poorly understood. A liquid swallow is typically biphasic, including air, so the actual bolus has both liquid and gas phases. We report a novel observation of annular two-phase flow (a ring of liquid around a core of air) as thin liquids passed through the upper esophageal sphincter (UES). Dynamic CT was performed on 27 healthy asymptomatic volunteers swallowing liquid barium in a semi-reclining position. Each subject swallowed 3, 10, and 20 ml of either thin (14 subjects) or thick liquid (13 subjects). Sagittal and axial images were analyzed. Flow patterns in the UES were assessed on cross-sectional images. Annular flow was seen in the majority of subjects with thin liquid but few with thick liquid swallows. The percentage of Annular flow during UES opening was 3 ml 58%, 10 ml 58%, 20 ml 56% in thin and 3 ml 0%, 10 ml 4%, 20 ml 1% in thick. Annular flow was usually observed from the second or third frames after onset of UES opening. The other pattern, Plug flow was seldom seen with thin but was typical with thick liquid swallows. Annular flow was the most common pattern for thin liquids (but not thick liquids) passing through the UES. Annular flow has been defined as a liquid continuum adjacent to the channel wall with a gas continuum (core) in the center of the channel. The two regions are demarcated by a gas–liquid interface. Annular flow is typical for two-phase gas–liquid flow in a vertical or inclined channel. It results from the interaction of viscosity with cohesive and adhesive forces in the two phases. We infer that the difference in flow pattern between thin liquid–air and thick liquid–air boluses resulted from the differing magnitudes of viscous forces.
Literature
1.
go back to reference Jacob P, Kahrilas PJ, Logemann JA, Shah V, Ha T. Upper esophageal sphincter opening and modulation during swallowing. Gastroenterology. 1989;97:1469–78.CrossRef Jacob P, Kahrilas PJ, Logemann JA, Shah V, Ha T. Upper esophageal sphincter opening and modulation during swallowing. Gastroenterology. 1989;97:1469–78.CrossRef
2.
go back to reference Cook IJ, Dodds WJ, Dantas RO, et al. Opening mechanisms of the human upper esophageal sphincter. Am J Physiol. 1989;257:G748–59.PubMed Cook IJ, Dodds WJ, Dantas RO, et al. Opening mechanisms of the human upper esophageal sphincter. Am J Physiol. 1989;257:G748–59.PubMed
3.
go back to reference Kahrilas PJ, Dodds WJ, Dent J, Logemann JA, Shaker R. Upper esophageal sphincter function during deglutition. Gastroenterology. 1988;95:52–62.CrossRef Kahrilas PJ, Dodds WJ, Dent J, Logemann JA, Shaker R. Upper esophageal sphincter function during deglutition. Gastroenterology. 1988;95:52–62.CrossRef
4.
go back to reference Ali G, Wallace KL, Luanda TM, Hunt DR, Decarle DJ, Cook IJ. Predictors of outcome of cricopharyngeal disruption for pharyngeal dysphagia. Dysphagia. 1997;12:133–9.CrossRef Ali G, Wallace KL, Luanda TM, Hunt DR, Decarle DJ, Cook IJ. Predictors of outcome of cricopharyngeal disruption for pharyngeal dysphagia. Dysphagia. 1997;12:133–9.CrossRef
5.
go back to reference Cock C, Jones CA, Hammer MJ, Omari TI, McCulloch TM. Modulation of upper esophageal sphincter (UES) relaxation and opening during volume swallowing. Dysphagia. 2017;32:216–24.CrossRef Cock C, Jones CA, Hammer MJ, Omari TI, McCulloch TM. Modulation of upper esophageal sphincter (UES) relaxation and opening during volume swallowing. Dysphagia. 2017;32:216–24.CrossRef
6.
go back to reference Pal A, Williams RB, Cook IJ, Brasseur JG. Intrabolus pressure gradient identifies pathological constriction in the upper esophageal sphincter during flow. Am J Physiol Gastrointest Liver Physiol. 2003;285:G1037–48.CrossRef Pal A, Williams RB, Cook IJ, Brasseur JG. Intrabolus pressure gradient identifies pathological constriction in the upper esophageal sphincter during flow. Am J Physiol Gastrointest Liver Physiol. 2003;285:G1037–48.CrossRef
7.
go back to reference Hewitt GF, Hall-Taylor NS. Regimes of flow. In: Annular two-phase flow. Oxford, New York, 1970:4–20.CrossRef Hewitt GF, Hall-Taylor NS. Regimes of flow. In: Annular two-phase flow. Oxford, New York, 1970:4–20.CrossRef
8.
go back to reference Inamoto Y, Saitoh E. Morphologic and kinematic analysis of swallowing using multislice CT. In Dysphagia Diagnosis and Treatment. Springer, 2017:333–349. Inamoto Y, Saitoh E. Morphologic and kinematic analysis of swallowing using multislice CT. In Dysphagia Diagnosis and Treatment. Springer, 2017:333–349.
9.
go back to reference Inamoto Y, Saitoh E, Ito Y, Kagaya H, et al. The Mendelsohn maneuver and its effects on swallowing: kinematic analysis in three-dimensions using dynamic area detector CT. Dysphagia. 2018;33:419–30.CrossRef Inamoto Y, Saitoh E, Ito Y, Kagaya H, et al. The Mendelsohn maneuver and its effects on swallowing: kinematic analysis in three-dimensions using dynamic area detector CT. Dysphagia. 2018;33:419–30.CrossRef
10.
go back to reference Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. RadioGraphics. 2004;24:1679–91.CrossRef Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. RadioGraphics. 2004;24:1679–91.CrossRef
12.
go back to reference Ito Y, Inamoto Y, Saitoh E, et al. The effect of bolus consistency on pharyngeal volume during swallowing: kinematic analysis in three dimensions using dynamic area detector CT. J Oral Rehabil. 2020;47:1287–96.CrossRef Ito Y, Inamoto Y, Saitoh E, et al. The effect of bolus consistency on pharyngeal volume during swallowing: kinematic analysis in three dimensions using dynamic area detector CT. J Oral Rehabil. 2020;47:1287–96.CrossRef
13.
go back to reference Iida T, Kagaya H, Inamoto Y, et al. Measurement of pharyngo-laryngeal volume during swallowing using 320-row area detector computed tomography. Dysphagia. 2017;32:749–58.CrossRef Iida T, Kagaya H, Inamoto Y, et al. Measurement of pharyngo-laryngeal volume during swallowing using 320-row area detector computed tomography. Dysphagia. 2017;32:749–58.CrossRef
14.
go back to reference Walczak CC, Jones CA, McCulloch TM. Pharyngeal pressure and timing during bolus transit. Dysphagia. 2007;32:104–14.CrossRef Walczak CC, Jones CA, McCulloch TM. Pharyngeal pressure and timing during bolus transit. Dysphagia. 2007;32:104–14.CrossRef
15.
go back to reference Mulheren R, Inamoto Y, Odonkor C, et al. The association of 3D volume and 2D area of post-swallow pharyngeal residue on CT imaging. Dysphagia. 2019;34:665–72.CrossRef Mulheren R, Inamoto Y, Odonkor C, et al. The association of 3D volume and 2D area of post-swallow pharyngeal residue on CT imaging. Dysphagia. 2019;34:665–72.CrossRef
16.
go back to reference Ho AK, Inamoto Y, Saitoh E et al. Extracting moving boundaries from dynamic, multislice CT images for fluid simulation. Comput Methods Biomech Biomed Eng Imaging. 2016:1–6. Ho AK, Inamoto Y, Saitoh E et al. Extracting moving boundaries from dynamic, multislice CT images for fluid simulation. Comput Methods Biomech Biomed Eng Imaging. 2016:1–6.
Metadata
Title
Annular Flow in the Upper Esophageal Sphincter Demonstrated with Dynamic 320-row Area Detector Computed Tomography
Authors
Yoko Inamoto
Eiichi Saitoh
Jeffrey B. Palmer
Publication date
01-12-2021
Publisher
Springer US
Published in
Dysphagia / Issue 6/2021
Print ISSN: 0179-051X
Electronic ISSN: 1432-0460
DOI
https://doi.org/10.1007/s00455-020-10241-9

Other articles of this Issue 6/2021

Dysphagia 6/2021 Go to the issue