Abstract

With the progressive elimination of mercury column devices for blood pressure (BP) measurement in children and adolescents, valid alternatives are needed. Oscillometric devices provide a replacement without mercury, are fully automated, and have excellent reliability among evaluators. Here, the goal was to test the accuracy of automatic blood pressure monitor devices compared to the mercury sphygmomanometer for BP measurement in children and adolescents. Electronic databases are EMBASE, MEDLINE (PubMed), SCOPUS, and Web of Science. We selected 8974 potentially eligible articles and two authors independently. We separately reviewed 370 full papers. Potentially eligible articles were selected according to the following criteria: (a) articles published in Portuguese, English, and Spanish; (b) screening of titles; (c) screening of abstracts; and (d) retrieval and screening of the full article to determine whether it met the inclusion criteria. We included 45 articles for analysis, 28 of which were selected for meta-analysis. The systolic BP measured by automatic blood pressure monitors presents 1.17 mmHg on average (95% CI 0.85; 1.48); for diastolic BP, it produced −0.08 mmHg (95% CI −0.69; 0.54) compared with a mercury sphygmomanometer. There is high heterogeneity between studies (> 90%) in the meta-analysis, partly explained by the device model, study environment, and observer training. Only articles that reported BP measurement by both methods were included.
Conclusion: Automatic blood pressure monitors have strong measurement validity when compared with the mercury column. Thus, these can be safely used in blood pressure measurements of children and adolescents in clinical and epidemiological studies.
What is Known:
•The “gold standard” for indirect BP measurement is the mercury sphygmomanometer.
•The accuracy of the automatic device is critical to any blood pressure measurement method.
What is New:
•Oscillometric or automatic devices can be a suitable alternative to auscultation for initial screening, consistent with current pediatric guidelines.
•The automatic devices compared to the mercury column have a good validity of measurements, which can be used in blood pressure measurements of children and adolescents in clinical and epidemiological settings, provided that international protocols are followed.
Appendix
Available only for authorised users
Literature
1.
go back to reference Lessa I (2004) Chronic non-communicable diseases in Brazil: a challenge for the complex task of surveillance. Ciênc Saúde Colet 9(4):931–943CrossRef Lessa I (2004) Chronic non-communicable diseases in Brazil: a challenge for the complex task of surveillance. Ciênc Saúde Colet 9(4):931–943CrossRef
3.
go back to reference De Moraes ACF, Lacerda MB, Moreno LA, Horta BL, Carvalho HB (2014) Prevalence of high blood pressure in 122, 053 adolescents: a systematic review and meta-regression. Medicine (United States) 93(27) De Moraes ACF, Lacerda MB, Moreno LA, Horta BL, Carvalho HB (2014) Prevalence of high blood pressure in 122, 053 adolescents: a systematic review and meta-regression. Medicine (United States) 93(27)
4.
go back to reference Falkner B (2010) Hypertension in children and adolescents: epidemiology and natural history. Pediatr Nephrol 25:1219–1224CrossRef Falkner B (2010) Hypertension in children and adolescents: epidemiology and natural history. Pediatr Nephrol 25:1219–1224CrossRef
5.
go back to reference Chen X, Wang Y (2008) Tracking blood pressure from childhood to adulthood: a systematic review and meta-regression analysis. Circulation 117:3171–3180CrossRef Chen X, Wang Y (2008) Tracking blood pressure from childhood to adulthood: a systematic review and meta-regression analysis. Circulation 117:3171–3180CrossRef
6.
go back to reference Bao W, Threefoot SA, Srinivasan SR, Berenson GS (1995) Essential hypertension predicted by tracking of elevated blood pressure from childhood to adulthood: the Bogalusa Heart Study. Am J Hypertens 8:657–665CrossRef Bao W, Threefoot SA, Srinivasan SR, Berenson GS (1995) Essential hypertension predicted by tracking of elevated blood pressure from childhood to adulthood: the Bogalusa Heart Study. Am J Hypertens 8:657–665CrossRef
7.
go back to reference National High Blood Pressure Education Program Working Group on High Blood Pressure in Children, Adolescents (2004) The fourth report on the diagnosis, evaluation, and treatment of high blood pressure in children and adolescents. Pediatrics 114:555–576 National High Blood Pressure Education Program Working Group on High Blood Pressure in Children, Adolescents (2004) The fourth report on the diagnosis, evaluation, and treatment of high blood pressure in children and adolescents. Pediatrics 114:555–576
8.
go back to reference Lurbe E, Cifkova R, Cruickshank JK, Dillon MJ, Ferreira I, Invitti C et al (2009) Management of high blood pressure in children and adolescents: recommendations of the European Society of Hypertension. J Hypertens 27:1719–1742CrossRef Lurbe E, Cifkova R, Cruickshank JK, Dillon MJ, Ferreira I, Invitti C et al (2009) Management of high blood pressure in children and adolescents: recommendations of the European Society of Hypertension. J Hypertens 27:1719–1742CrossRef
9.
go back to reference Jones DW, Appel LJ, Sheps SG, Roccella EJ, Lenfant C (2003) Measuring blood pressure accurately: new and persistent challenges. JAMA 289:1027–1030CrossRef Jones DW, Appel LJ, Sheps SG, Roccella EJ, Lenfant C (2003) Measuring blood pressure accurately: new and persistent challenges. JAMA 289:1027–1030CrossRef
10.
go back to reference Hla KM, Vokaty KA, Feussner JR (1986) Observer error in systolic blood pressure measurement in the elderly. A case for automatic recorders? Arch Intern Med 146:2373–2376CrossRef Hla KM, Vokaty KA, Feussner JR (1986) Observer error in systolic blood pressure measurement in the elderly. A case for automatic recorders? Arch Intern Med 146:2373–2376CrossRef
11.
go back to reference Daskalopoulou SS, Rabi DM, Zarnke KB, Dasgupta K, Nerenberg K, Cloutier L et al (2015) The 2015 Canadian Hypertension Education Program recommendations for blood pressure measurement, diagnosis, assessment of risk, prevention, and treatment of hypertension. Can J Cardiol 31:549–568CrossRef Daskalopoulou SS, Rabi DM, Zarnke KB, Dasgupta K, Nerenberg K, Cloutier L et al (2015) The 2015 Canadian Hypertension Education Program recommendations for blood pressure measurement, diagnosis, assessment of risk, prevention, and treatment of hypertension. Can J Cardiol 31:549–568CrossRef
12.
go back to reference Araújo-Moura K, De Moraes ACF, Forkert ECO, Berg G, Cucato GG, Forjaz CLM, Moliterno P, Gaitan-Charry D, Delgado CA, González-Gil EM, Moreno LA, Carvalho HB, Torres-Leal FL (2018) Is the measurement of blood pressure by automatic monitor in the South American pediatric population accurate? SAYCARE Study Obesity (Silver Spring) 26(Suppl 1):S41–S46. https://doi.org/10.1002/oby.22119 (PMID: 29464919)CrossRef Araújo-Moura K, De Moraes ACF, Forkert ECO, Berg G, Cucato GG, Forjaz CLM, Moliterno P, Gaitan-Charry D, Delgado CA, González-Gil EM, Moreno LA, Carvalho HB, Torres-Leal FL (2018) Is the measurement of blood pressure by automatic monitor in the South American pediatric population accurate? SAYCARE Study Obesity (Silver Spring) 26(Suppl 1):S41–S46. https://​doi.​org/​10.​1002/​oby.​22119 (PMID: 29464919)CrossRef
13.
go back to reference Stergiou GS, Boubouchairopoulou N, Kollias A (2017) Accuracy of automated blood pressure measurement in children: evidence, issues, and perspectives. Hypertension 69:1000–1006CrossRef Stergiou GS, Boubouchairopoulou N, Kollias A (2017) Accuracy of automated blood pressure measurement in children: evidence, issues, and perspectives. Hypertension 69:1000–1006CrossRef
14.
go back to reference Balestrieri E, Rapuano S (2010) Instruments and methods for calibration of oscillometric blood pressure measurement devices. IEEE Trans Instrum Meas 59:2391–2404CrossRef Balestrieri E, Rapuano S (2010) Instruments and methods for calibration of oscillometric blood pressure measurement devices. IEEE Trans Instrum Meas 59:2391–2404CrossRef
15.
go back to reference Guyatt GH, Oxman AD, Vist G, Kunz R, Brozek J, Alonso-Coello P et al (2011) GRADE guidelines: 4. Rating the quality of evidence--study limitations (risk of bias). J Clin Epidemiol 64:407–15 Guyatt GH, Oxman AD, Vist G, Kunz R, Brozek J, Alonso-Coello P et al (2011) GRADE guidelines: 4. Rating the quality of evidence--study limitations (risk of bias). J Clin Epidemiol 64:407–15
19.
22.
go back to reference Butani L, Morgenstern BZ (2003) Are pitfalls of oscillometric blood pressure measurements preventable in children? Pediatr Nephrol 18:313–318CrossRef Butani L, Morgenstern BZ (2003) Are pitfalls of oscillometric blood pressure measurements preventable in children? Pediatr Nephrol 18:313–318CrossRef
23.
go back to reference O’Brien E, Mee F, Atkins N et al (1996) Evaluation of three devices for eel-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Neissei DS- 175. Blood Press Monit 1:55–61PubMed O’Brien E, Mee F, Atkins N et al (1996) Evaluation of three devices for eel-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Neissei DS- 175. Blood Press Monit 1:55–61PubMed
24.
go back to reference O’Brien E, Petrie J, Littler WA et al (1990) The British Hypertension Society Protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 8(7):607–619CrossRef O’Brien E, Petrie J, Littler WA et al (1990) The British Hypertension Society Protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 8(7):607–619CrossRef
25.
go back to reference Lurbe E, Agabiti-Rosei E, Cruickshank JK, Dominiczak A, Erdine S et al (2016) European Society of Hypertension guidelines for the management of high blood pressure in children and adolescents. J Hypertens 34(10):1887-1920 Lurbe E, Agabiti-Rosei E, Cruickshank JK, Dominiczak A, Erdine S et al (2016) European Society of Hypertension guidelines for the management of high blood pressure in children and adolescents. J Hypertens 34(10):1887-1920
26.
go back to reference Flynn JT, Kaelber DC, Baker-Smith CM et al (2017) Subcommittee on Screening and Management of High Blood Pressure in Children. Clinical Practice Guideline for Screening and Management of High Blood Pressure in Children and Adolescents. Pediatrics 140(3):e20171904 Flynn JT, Kaelber DC, Baker-Smith CM et al (2017) Subcommittee on Screening and Management of High Blood Pressure in Children. Clinical Practice Guideline for Screening and Management of High Blood Pressure in Children and Adolescents. Pediatrics 140(3):e20171904
27.
go back to reference Kaufmann MA, Pargger H, Drop LJ (1996) Oscillometric blood pressure measurements by different devices are not interchangeable. Anesth Analg 82:377–381PubMed Kaufmann MA, Pargger H, Drop LJ (1996) Oscillometric blood pressure measurements by different devices are not interchangeable. Anesth Analg 82:377–381PubMed
28.
go back to reference O’Brien E, Atkins N (1997) Accuracy of the Dinamap portable monitor, model 8100: a review of the evidence for accuracy. Blood Press Monit 2:31–33PubMed O’Brien E, Atkins N (1997) Accuracy of the Dinamap portable monitor, model 8100: a review of the evidence for accuracy. Blood Press Monit 2:31–33PubMed
29.
go back to reference O’Brien E, O’Malley K (1990) Evaluation of blood pressure measuring devices with special reference to ambulatory systems. J Hypertens Suppl 8:S133–S139PubMed O’Brien E, O’Malley K (1990) Evaluation of blood pressure measuring devices with special reference to ambulatory systems. J Hypertens Suppl 8:S133–S139PubMed
30.
go back to reference Lurbe E (2013) Ambulatory blood pressure in children: confidence and wisdom. J Hypertens 31:2125–2127CrossRef Lurbe E (2013) Ambulatory blood pressure in children: confidence and wisdom. J Hypertens 31:2125–2127CrossRef
31.
go back to reference Carvalho HB, Moreno LA, Silva AM et al (2018) Design and objectives of the South American Youth/Child Cardiovascular and Environmental (SAYCARE) study. Obesity (Silver Spring) 26(suppl 1):S14–S22 Carvalho HB, Moreno LA, Silva AM et al (2018) Design and objectives of the South American Youth/Child Cardiovascular and Environmental (SAYCARE) study. Obesity (Silver Spring) 26(suppl 1):S14–S22
33.
go back to reference Neuhauser HK, Thamm M, Ellert U, Hense HW, Rosario AS (2011) Blood pressure percentiles by age and height from nonoverweight children and adolescents in Germany. Pediatrics 127:e978-988CrossRef Neuhauser HK, Thamm M, Ellert U, Hense HW, Rosario AS (2011) Blood pressure percentiles by age and height from nonoverweight children and adolescents in Germany. Pediatrics 127:e978-988CrossRef
34.
go back to reference Matsuoka S, Awazu M (2004) Masked hypertension in children and young adults. Pediatr Nephrol 19:651–654CrossRef Matsuoka S, Awazu M (2004) Masked hypertension in children and young adults. Pediatr Nephrol 19:651–654CrossRef
35.
go back to reference Smith GR (2000) Devices for blood pressure measurement. Prof Nurse 15(337–340):13 Smith GR (2000) Devices for blood pressure measurement. Prof Nurse 15(337–340):13
36.
go back to reference Park MK, Menard SM (1989) Normative oscillometric blood pressure values in the first 5 years in an office setting. Am J Dis Child 143:860–864PubMed Park MK, Menard SM (1989) Normative oscillometric blood pressure values in the first 5 years in an office setting. Am J Dis Child 143:860–864PubMed
37.
go back to reference Freedman DS, Foltz JL, Berenson GS (2014) Differences between the fourth and fifth Korotkoff phases among children and adolescents. Am J Hypertens 27:1495–1502CrossRef Freedman DS, Foltz JL, Berenson GS (2014) Differences between the fourth and fifth Korotkoff phases among children and adolescents. Am J Hypertens 27:1495–1502CrossRef
38.
go back to reference Egger M, Smith GD, Schneider M, Minder C (1997) Bias in meta-analysis detected by a simple, graphical test. BMJ 315:629–634CrossRef Egger M, Smith GD, Schneider M, Minder C (1997) Bias in meta-analysis detected by a simple, graphical test. BMJ 315:629–634CrossRef
39.
go back to reference Borenstein M, Hedges LV, Higgins JPT, Rothstein HR (2009) Introduction to meta-analysis: John Wiley & Sons; Chapter 20, Meta-regression; p. 187–203 Borenstein M, Hedges LV, Higgins JPT, Rothstein HR (2009) Introduction to meta-analysis: John Wiley & Sons; Chapter 20, Meta-regression; p. 187–203
40.
go back to reference Pereira GM, Galvão FT (2014) Heterogeneity and publication bias in systematic reviews. Epidemiol Serv Saúd:775–778 Pereira GM, Galvão FT (2014) Heterogeneity and publication bias in systematic reviews. Epidemiol Serv Saúd:775–778
41.
go back to reference Moyer VA (2013) U.S. Preventive Services Task Force. Screening for primary hypertension in children and adolescents: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med 159:613–619 Moyer VA (2013) U.S. Preventive Services Task Force. Screening for primary hypertension in children and adolescents: U.S. Preventive Services Task Force recommendation statement. Ann Intern Med 159:613–619
42.
go back to reference Krist AH, Davidson KW et al (2020) US Preventive Services Task Force. Screening for high blood pressure in children and adolescents: US Preventive Services Task Force recommendation statement. JAMA 10;324(18):1878–1883 Krist AH, Davidson KW et al (2020) US Preventive Services Task Force. Screening for high blood pressure in children and adolescents: US Preventive Services Task Force recommendation statement. JAMA 10;324(18):1878–1883
43.
go back to reference Lewis MN, Shatat IF, Phillips SM (2017) Screening for hypertension in children and adolescents: methodology and current practice recommendations. Front Pediatr 15(5):51 Lewis MN, Shatat IF, Phillips SM (2017) Screening for hypertension in children and adolescents: methodology and current practice recommendations. Front Pediatr 15(5):51
44.
go back to reference Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN et al (2005) Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Circulation 111:697–716CrossRef Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN et al (2005) Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Circulation 111:697–716CrossRef
Metadata
Title
Blood pressure measurement in pediatric population: comparison between automated oscillometric devices and mercury sphygmomanometers—a systematic review and meta-analysis
Authors
Keisyanne Araujo-Moura
Letícia Gabrielle Souza
Gabriele Luz Mello
Augusto César Ferreira De Moraes
Publication date
01-01-2022
Publisher
Springer Berlin Heidelberg
Published in
European Journal of Pediatrics / Issue 1/2022
Print ISSN: 0340-6199
Electronic ISSN: 1432-1076
DOI
https://doi.org/10.1007/s00431-021-04171-3

Other articles of this Issue 1/2022

European Journal of Pediatrics 1/2022 Go to the issue